VECTRON TFS115C

Filename: tfs 115c.doc
Version 1.6
VI TELEFILTER
03.02.2006
Filter specification
TFS 115C
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
20
0
°C
dBm
297 Ω || -28 pF
235 Ω || -35 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 115C is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1 dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 115,2 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss
(reference level)
ae
7,4
Nominal frequency
fN
-
PB
-
Pass band ripple
p-p
0,5
dB
Relative attenuation
arel
0,7
Passband
fN
fN
fN
±
±
25
10
... fN
±
MHz ... fN
MHz ... fN
±
±
1,92
10
5
MHz
MHz
MHz
Absolute Group delay in PB
p-p
Group delay ripple in PB
p-p
OTR
Storage temperature range
Temperature coefficient of frequency
0,76
65
TCf ***
max.
10
115,2
fN
MHz
MHz
max.
1
dB
dB
max.
3
dB
dB
dB
min.
min.
38
32
dB
dB
µs
max.
ns
max.
150
max.
10
±
0,85
-
-10 °C..... +85 °C
-
-40 °C..... +85 °C
-27
dB
1,92
-
Input power level **
Operating temperature range
52
45
dB
tolerance / limit
ppm/K
µs
ns
dBm
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) Maximum value for 10 years operation.
***) ∆fc(Hz) = TCf(ppm/K) x (T - To) x fTo (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 115c.doc
Version 1.6
VI TELEFILTER
03.02.2006
Filter specification
TFS 115C
2/5
0
1.81
-1
1.69
-20
-2
1.57
-30
-3
1.45
-40
-4
1.33
-5
1.21
-6
1.09
-70
-7
0.97
-80
-8
0.85
-90
-9
0.73
-50
-60
-100
70.2
79.2
88.2
97.2
106.2
115.2
124.2
frequency in MHz
133.2
142.2
151.2
-10
112.2
160.2
112.8
113.4
114
114.6
115.2
115.8
frequency in MHz
116.4
117
117.6
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
0.61
118.2
Construction and pin connection
(All dimensions in mm)
S 115C
●
U05
Date code
1
2
3
4
5
6
7
8
9
10
Ground
Ground
Ground
Output
Output RF Return
Ground
Ground
Ground
Input
Input RF Return
Date code:
U
V
W
...
Year + week
2006
2007
2008
50 Ohm Test circuit
L1
C1
4
9
10
SAW
5
L2
C2
1, 2, 3, 6, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 115c.doc
Version 1.6
VI TELEFILTER
03.02.2006
Filter specification
TFS 115C
3/5
Stability characteristics
1.
High Temperature (IEC 60068 -3-1)
1,000 hours at +85C
2.
Low Temperature (IEC 60068 -3-1)
1,000 hours at – 40C
3.
Humidity (IEC 60068 -2-78)
1,000 hours at 85% /85C
4.
Thermal Shock ( IEC60068-2-14 )
-55 °C to 125°C / 30 min. each / 10 cycles
5.
Vibration (IEC 60068 -2-6)
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans
6.
Shock (IEC 60068 -2-27)
500g, 1 ms, half sine wave, 3 shocks each plane
7.
Reflow Profile ( defined at specification )
260°C +/- 5°C for 10 seconds, 2 cycles
8.
Solerability
235°C +/- 5°C for 15 seconds, 1 cycle
9.
Pullability, Distortion
according to MIL-STD 883 method 2004.5 Condition D
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,50 ± 0,1
Bo
: 7,50 ± 0,1
Ct
: 13,5 ± 0,1
t
Po
PIN Marker
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Date Code
Typ
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 115c.doc
Version 1.6
VI TELEFILTER
03.02.2006
Filter specification
TFS 115C
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 115c.doc
VI TELEFILTER
Version 1.6
Filter specification
03.02.2006
TFS 115C
5/5
History :
Version
Reason of Changes
Name
Date
1.0
Generate development specification
Chilla
2.11.2004
1.1
changed insertion loss
changed relative attenuation
Chilla
9.11.2004
1.2
reduced insertion loss to 10dB
Chilla
29.11.2004
1.3
added absolute group delay in PB
changed package
Chilla
14.12.2004
1.4
changed stability characteristics
changed date code
changed packing
changed air reflow temperature conditions
Chilla
05.01.2005
1.5
customer reliability requirement added
Steiner
15.02.2005
1.6
generate filter specification
terminating impedances added
typical values added
filter characteristics added
test circuit added
ROHS compliance added
Chilla
03.02.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.