VECTRON TFS1150A

Filename: tfs1150A.doc
Version 1.4
VI TELEFILTER
06.01.2004
Development specification
TFS1150 A
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
0
°C
dBm
100
100
Characteristics
Remark:
The Reference level for the relative attenuation a rel of the TFS1150A is the minimum attenuation in the pass band. The minimum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1150 MHz without tolerance or limit. The values of relative attenuation arel are
guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production
tolerance scheme.
Data
typ. value
Insertion loss
ae
-
Nominal frequency
fN
-
fN
fN
-
5
8
MHz ... fN
MHz ... fN
+
+
5
8
Absolute attenuation
0
1100
1120
1170
1180
1190
MHz
MHz
MHz
MHz
MHz
MHz
...
...
...
...
...
...
1100
1120
1130
1180
1190
1900
Group delay
**)
dB
1150
MHz
5
MHz
arel
MHz
MHz
aabs
-
max.
max.
1
3
dB
dB
MHz
MHz
MHz
MHz (0...+ 80°C)
MHz
MHz
-
min.
min.
min.
min.
min.
min.
50
35
15
15
35
50
dB
dB
dB
dB
dB
dB
at fN
OTR
Storage temperature range
Temperature coefficient of frequency
2,7
fN ±
Group delay ripple within PB
Operating temperature range
max.
-
Passband
Relative attenuation
tolerance / limit
TCf **
-
100
ns
-
35
ns
-
- 40 °C ... + 85 °C
-
- 40 °C ... + 85 °C
T.B.D
ppm/K
-
fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D-14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs1150A.doc
Version 1.4
VI TELEFILTER
06.01.2004
Development specification
TFS1150 A
2/5
Construction and pin configuration
(All dimensions in mm)
5
6
4
Date code: Year+week
B50A
S02
1
2
1
0,6
6
3
3
date code
S
T
U
2004
2005
2006
...
Pin
Pin
Pin
Pin
Pin
Pin
1
2
3
4
5
6
Input
Input
Ground
Output
Output
Ground
4
0,6
Tele Filter GmbH
Potsdamer Straße 18
D-14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs1150A.doc
Version 1.4
VI TELEFILTER
Development specification
06.01.2004
TFS1150 A
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
T.B.D
Tele Filter GmbH
Potsdamer Straße 18
D-14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs1150A.doc
Version 1.4
VI TELEFILTER
06.01.2004
Development specification
TFS1150 A
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
pre-heating periods main-heating periods
150 °C - 170 °C
over 200 °C
60 sec. - 90 sec.
20 sec. - 25 sec.
Name:
Temperature:
Time:
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / s ec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Tele Filter GmbH
Potsdamer Straße 18
D-14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs1150A.doc
VI TELEFILTER
Version 1.4
Development specification
06.01.2004
TFS1150 A
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Konietzko
19.09.2003
1.1
- Package drawing corrected.
- Marking changed.
Wall
24.09.2003
1.2
- Change of fN 8 MHz specification, change of temperature range
(1170 MHz – 1180 MHz )
Roizengaft
16.12.2003
1.3
- Change of package
Roizengaft
06.01.2004
1.4
- Change of passband from
Roizengaft
06.01.2004
8 to
5 MHz
Tele Filter GmbH
Potsdamer Straße 18
D-14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.