Measurement condition
Ambient temperature TA:
Input power level:
Terminating impedances :
23 °C
0 dBm.
100 // -4,0 pF
100 // -4,0 pF
Characteristics
Remark:
Reference level for the relative attenuation a rel of the TFS 454 is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation a min is defined as the insertion loss a e. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the 3dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 454,00 MHz without tolerance. The given values for the relative
attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency f c is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc
Data
typ. value
ae= amin
Insertion loss
(reference level)
Nominal frequency
fN
Centre frequency
fC
BW
Bandwidth
-
MHz
max.
4,5
454
454
9,5
MHz
MHz
MHz
MHz
min.
dB
min.
4,0
MHz
arel
Relative attenuation
fN
3,5
-
tolerance / limit
42,8
MHz
Operating temperature range
60
OTR
Temperature coefficient of frequency
TCf **
-32
dB
- 10 °C ... + 50°C
-
- 40 °C ... + 85°C
-
Storage temperature range
55
ppm/K
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
** fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 454.doc
Version 1.2
VI TELEFILTER
16.04.2004
Filter specification
TFS 454
2/5
Filter characteristic
B
d
ni
e
d
ut
i
n
g
a
m
0
0
-5
-10
-10
-20
-15
-30
-20
B
d
ni
e
d
ut
i
n
g
a
m
-25
-30
-40
-50
-60
-35
-70
-40
-80
-45
-90
-50
-100
430
435
440
445
450
455
460
frequency in MHz
465
470
475
250
300
350
400
450
500
frequency in MHz
550
600
650
700
Construction and pin connection
(All dimensions in mm)
M a x. 3, 5
3, 0 ± 0,5
1
2, 54 ± 0, 2
0 ,45 ± 0, 2 D ia .
1
2
3
4
Input
Ground
Ground
Output
Date code:
S
T
U
...
Year + week
2004
2005
2006
3x 2,5 4 = 7, 62 ± 0,2
S 454
S 15
M ax . 4, 8
M a x. 11 ,4
Date code
50 Ohm Test circuit
1
L2
4
C2
2,3
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 454.doc
VI TELEFILTER
Version 1.2
Filter specification
16.04.2004
TFS 454
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 454.doc
Version 1.2
VI TELEFILTER
16.04.2004
Filter specification
TFS 454
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods main-heating periods
150 °C - 170 °C
over 200 °C
60 sec. - 90 sec.
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 454.doc
VI TELEFILTER
Version 1.2
Filter specification
16.04.2004
TFS 454
5/5
History
Version
Reason of Changes
Name
Date
1.0
generated specification according to customer requierment
S. Sabah
23.06.2000
1.1
correct of terminating impedances
Dr. Sabah
31.07.2003
1.2
add filter characteristic
change centre - and nominal frequency
Noack
07.04.2004
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.