Filename: tfs 150u.doc Version 1.5 VI TELEFILTER 17.11.2006 Filter specification TFS 150U 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 70 Ω || -16,6 pF 35 Ω || -14,7 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS150U is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper ( f3dB+ ) and lower (f3dB-) frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The bandwidth shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value ae Insertion loss (reference level) fC Centre frequency at ambient temperature PB Passband in OTR p-p Pass band ripple f3dB+ f3dBf3dB+ f3dBf3dB+ f3dBf3dB+ f3dBf3dB+ f3dBf3dB+ f3dB- + + + + + + - MHz - 23 dB 150,0±0,1 MHz ( BW 3dB -0,30 ) MHz 17,5 17,5 in OTR Relative attenuation + 150,0 max. dB max. 1,2 dB BW dB dB f3dB- dB 0,6 Bandwidth 3 3 22 tolerance / limit 0,15 MHz 0,40 0,60 0,60 1,00 1,00 5,00 5,00 25,00 25,00 35,00 35,00 100,00 MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz … f3dB+ - … … … … … … … … … … … … + + + + + + - f3dB+ f3dBf3dB+ f3dBf3dB+ f3dBf3dB+ f3dBf3dB+ f3dBf3dB+ f3dB- 0,60 0,40 1,00 0,60 5,00 1,00 25,00 5,00 35,00 25,00 100,00 35,00 MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz mean value in PB Group delay Group delay ripple within PB arel 0,15 MHz p-p Deviation from linear phase within PB 1,0 24 24 38 38 52 52 58 56 64 56 64 58 2,3 70 p-p MHz MHz 17,5 ± 0,05 MHz 17,5 ± 0,16 MHz dB max. dB dB dB dB dB dB dB dB dB dB dB dB min. min. min. min. min. min. min. min. min. min. min. min. µs max. ns max. 12° 1,2 20 20 32 32 42 42 49 49 47 47 52 52 3,0 150 46 dB Crosstalk attenuation compared to main signal 65 dB - 6 dB - Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf ** µs ns - - - 25 °C ... + 80°C - - 40 °C ... + 85°C -94 dB dB dB dB dB dB dB dB dB dB dB dB - Triple transit attenuation compared to main signal Input/Output return loss within PB dB ppm/K - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 150u.doc Version 1.5 VI TELEFILTER 17.11.2006 Filter specification TFS 150U 2/5 Filter characteristic 0 0 3.4 -7 -1 3.28 -14 -2 3.16 -3 3.04 -4 2.92 -5 2.8 -6 2.68 -7 2.56 -8 2.44 -9 2.32 -21 -35 -42 delay in µs magnitude in dB magnitude in dB -28 -49 -56 -63 -70 50 70 90 110 130 150 170 frequency in MHz 190 210 230 -10 141 250 142.8 144.6 146.4 148.2 150 151.8 frequency in MHz 153.6 155.4 157.2 2.2 159 Construction and pin connection (All dimensions in mm) TFS 150U ● U46 13 Max. 22,5 Max. 1 2 7 8 9 14 Input Ground Output RF Return Output Ground Input RF Return Date code: U V W ... Year + week 2006 2007 2008 Date code 7 1 6 Max. 4,5 Min. 7,62+/-0,2 5 Max. 1Dia.0,45+/-0,05 10,16+/-0,2 14 15,24+/-0,2 8 50 Ohm Test circuit 1 L1 14 8 SAW L2 L2 7 C2 2, 9 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 150u.doc Version 1.5 VI TELEFILTER Filter specification 17.11.2006 TFS 150U 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 150u.doc Version 1.5 VI TELEFILTER 17.11.2006 Filter specification TFS 150U 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 150u.doc VI TELEFILTER Version 1.5 Filter specification 17.11.2006 TFS 150U 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 23.08.2005 1.1 - Temperature coefficient corrected Steiner 05.09.2005 1.2 - Change reference for bandwidth and arel from 1,5dB to 3dB Strehl 09.09.2005 1.3 - Change insertion loss - Change relative attenuation - Change reference for bandwidth and arel from 3dB to 1,5dB - Add frequency inversion temperature - Change temperature coefficient - Change stability characteristics Alawneh 28.04.2006 1.4 - Change insertion loss - Change relative attenuation - Change reference for bandwidth and arel from 1,5dB to 3dB - Delate frequency inversion temperature - Change temperature coefficient Strehl 18.07.2006 1.5 - add of terminating impedances, typical value, filter characteristics and matching configuration - ‘remarks’ corrected Pfeiffer 17.11.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.