Filename: tfs 642.doc Version 1.5 VI TELEFILTER 19.07.2006 Filter specification TFS 642 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 0 °C dBm 50 50 Ω Ω Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 642 MHz without any tolerance or limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. Value tolerance / limit Insertion loss within PB ae 2,0 Nominal frequency fN - 642 MHz Passband PB - 24 MHz fN ± max. 3,0 dB aabs Absolute attenuation fN + dB MHz ... fN ± 149 MHz 50 dB min. 33,5 dB 149 MHz ... fN + 300 MHz 49 dB min. 45 dB 1 MHz … 200 MHz 58 dB min. 50 dB MHz … fN - 149 MHz 62 dB min. 55 dB 10 ns max. 80 200 Group delay ripple within PB p-p IIP3 * Input power level Operating temperature range OTR Storage temperature range Temperature coefficient of frequency µs - min. 36 dBm - max. 10 dBm - - 10 °C ... + 75 °C TCf ** 0,2 -76 - 40 °C ... + 85 °C ppm/K - *) fin1= fC - 14 MHz; fin2= fC – 14,4 MHz; Pin=0 dBm; fmeasurement1 = fC - 13,6 MHz; fmeasurement2 = fC - 14,8 MHz. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. **) ∆ f(Hz) =TCf(ppm/K) x(T-T0) x fTo (MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 642.doc Version 1.5 VI TELEFILTER 19.07.2006 Filter specification TFS 642 2/5 0 0.5 -10 -1 0.45 -20 -2 0.4 -30 -3 0.35 -40 -4 0.3 -5 0.25 -50 -60 -6 0.2 -70 -7 0.15 -80 -8 0.1 -90 -9 0.05 -100 142 242 342 442 542 642 742 frequency in MHz 842 942 1042 -10 1142 620 625 630 635 640 645 frequency in MHz 650 655 660 665 delay in µs 0 magnitude in dB magnitude in dB Filter characteristic 0 Construction and pin connection (All dimensions in mm) 7 642 ● U29 1 SQ 3,81 +0,2/-0,1 5 1 2 3 4 5 6 7 8 Ground Input Ground Ground Ground Output Ground Ground Date code: U V W ... Year + week 2006 2007 2008 3 7 5 0,1 12 0% 0,6 % d 3 1,78 2,54 1 1,2 Max. Date code 1,78 50 Ω Test circuit L1 2 6 L2 SAW 1, 3, 4, 5, 7, 8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 642.doc Version 1.5 VI TELEFILTER 19.07.2006 Filter specification TFS 642 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 4,30 ± 0,1 Bo : 4,30 ± 0,1 Ct : 9,5 ± 0,1 P1 Date Code Do P2 W G Ct Bo F G E t Po Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 642.doc Version 1.5 VI TELEFILTER 19.07.2006 Filter specification TFS 642 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 642.doc VI TELEFILTER Version 1.5 Filter specification 19.07.2006 TFS 642 5/5 History Version Reason of Changes Name Date 1.0 Generation of development specification Springfeldt 14.04.2004 1.1 adjust attenuation and loss to new customer requirements Noack 26.11.2004 1.2 adjust attenuation and loss to new customer requirements Martens 29.11.2004 1.3 Change of absolute attenuation Strehl 20.01.2005 1.4 Change stability characteristics add typical values and filter characteristic generation of filter specification Strehl 04.05.2005 1.5 Add IIP3 and stability characteristics Strehl 19.07.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.