VECTRON TFS642

Filename: tfs 642.doc
Version 1.5
VI TELEFILTER
19.07.2006
Filter specification
TFS 642
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
0
°C
dBm
50
50
Ω
Ω
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 642 MHz without any tolerance or limit.
The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
typ. Value
tolerance / limit
Insertion loss within PB
ae
2,0
Nominal frequency
fN
-
642
MHz
Passband
PB
-
24
MHz
fN ±
max.
3,0
dB
aabs
Absolute attenuation
fN +
dB
MHz ...
fN ±
149
MHz
50
dB
min.
33,5
dB
149
MHz ...
fN +
300
MHz
49
dB
min.
45
dB
1
MHz …
200
MHz
58
dB
min.
50
dB
MHz … fN -
149
MHz
62
dB
min.
55
dB
10
ns
max.
80
200
Group delay ripple within PB
p-p
IIP3
*
Input power level
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
µs
-
min.
36
dBm
-
max.
10
dBm
-
- 10 °C ... + 75 °C
TCf **
0,2
-76
- 40 °C ... + 85 °C
ppm/K
-
*) fin1= fC - 14 MHz; fin2= fC – 14,4 MHz; Pin=0 dBm; fmeasurement1 = fC - 13,6 MHz; fmeasurement2 = fC - 14,8 MHz. The centre frequency fc is the arithmetic mean
value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae.
**) ∆ f(Hz) =TCf(ppm/K) x(T-T0) x fTo (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 642.doc
Version 1.5
VI TELEFILTER
19.07.2006
Filter specification
TFS 642
2/5
0
0.5
-10
-1
0.45
-20
-2
0.4
-30
-3
0.35
-40
-4
0.3
-5
0.25
-50
-60
-6
0.2
-70
-7
0.15
-80
-8
0.1
-90
-9
0.05
-100
142
242
342
442
542
642
742
frequency in MHz
842
942
1042
-10
1142
620
625
630
635
640
645
frequency in MHz
650
655
660
665
delay in µs
0
magnitude in dB
magnitude in dB
Filter characteristic
0
Construction and pin connection
(All dimensions in mm)
7
642
● U29
1
SQ 3,81 +0,2/-0,1
5
1
2
3
4
5
6
7
8
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
Date code:
U
V
W
...
Year + week
2006
2007
2008
3
7
5
0,1
12
0%
0,6
%
d
3
1,78
2,54
1
1,2 Max.
Date code
1,78
50 Ω Test circuit
L1
2
6
L2
SAW
1, 3, 4, 5, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 642.doc
Version 1.5
VI TELEFILTER
19.07.2006
Filter specification
TFS 642
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 4,30 ± 0,1
Bo
: 4,30 ± 0,1
Ct
: 9,5 ± 0,1
P1
Date Code
Do
P2
W
G
Ct
Bo
F
G
E
t
Po
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 642.doc
Version 1.5
VI TELEFILTER
19.07.2006
Filter specification
TFS 642
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 642.doc
VI TELEFILTER
Version 1.5
Filter specification
19.07.2006
TFS 642
5/5
History
Version
Reason of Changes
Name
Date
1.0
Generation of development specification
Springfeldt
14.04.2004
1.1
adjust attenuation and loss to new customer requirements
Noack
26.11.2004
1.2
adjust attenuation and loss to new customer requirements
Martens
29.11.2004
1.3
Change of absolute attenuation
Strehl
20.01.2005
1.4
Change stability characteristics
add typical values and filter characteristic
generation of filter specification
Strehl
04.05.2005
1.5
Add IIP3 and stability characteristics
Strehl
19.07.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.