Filename: tfs 243.doc Version 1.3 VI TELEFILTER 15.12.2006 Filter specification TFS 243 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: External Coil: 23 0 °C dBm 310 Ω || -3,4 pF 310 Ω || -3,4 pF 100 nH Characteristics Remark: The reference level for the relative attenuation arel of the TFS 243 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 243 MHz without any tolerance. The given values for both the relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (reference level) ae Nominal frequency fN - Centre frequency fC 243,0 fN ± 100 kHz ± ± ± + + 400 600 800 1,6 1,6 15 kHz kHz kHz MHz MHz MHz dB max. 5,0 243,0 MHz dB MHz - arel Relative attenuation fN fN fN fN fN fN 3,2 tolerance / limit … … … … … … fN fN fN fN fN fN ± ± ± + + 600 800 1,6 25 15 25 kHz kHz kHz MHz MHz MHz max. 3 dB 30 40 50 57 48 55 dB dB dB dB dB dB min. min. min. min. min. min. 25 36 45 50 45 50 dB dB dB dB dB dB 1 µs max. Group delay ripple fN ± 70 kHz Operating temperature range OTR + 25 Frequency inversion temperature TCf ** -0,036 µs - 25 °C ... + 85°C - Storage temperature range Temperature coefficient of frequency - 1,5 - 30 °C ... + 85°C °C ppm/K 2 *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fTo(MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 243.doc Version 1.3 VI TELEFILTER 15.12.2006 Filter specification TFS 243 2/5 0 -0.5 -20 -1 -30 -1.5 -40 -50 -60 -4 -90 -4.5 242.6 242.8 243 243.2 frequency in MHz 243.4 243.6 243.8 -5 244 4.5 4 3.5 -3 -80 242.4 5 -2 -3.5 242.2 5.5 -2.5 -70 -100 242 6 3 group delay in µs 0 -10 magnitude in dB magnitude in dB Filter characteristic 2.5 2 1.5 1 242.8 242.85 242.9 242.95 243 243.05 243.1 243.15 243.2 243.25 frequency in MHz Construction and pin connection (All dimensions in mm) Pin connection balanced 1 Output 2 Output 3 External Coil 4 Ground 5 Ground 6 Input 7 Input 8 Ground 9 Ground 10 Ground 7,3 Max. 9,3 Max. 1,6 Max. TFS 243 ● U50 Date code Pin connection unbalanced 1 Output 2 Output RF Return 3 External Coil 4 Ground 5 Ground 6 Input 7 Input RF Return 8 Ground 9 Ground 10 Ground 5,08 2,54 Date code: U V W ... 0,8 R0 ,2 Year + week 2006 2007 2008 0,1 1 50 Ω Test circuit balanced 6 1 C1 L1 C2 C3 SAW 7 3 2 L2 C4 L3 4, 5, 8, 9, 10 50 Ω Test circuit unbalanced 6 L1 C1 1 L2 SAW 3 C2 2, 4, 5, 7, 8, 9, 10 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 243.doc Version 1.3 VI TELEFILTER 15.12.2006 Filter specification TFS 243 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 2000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,10 F : 7,50 ± 0,10 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 +0,1/-0 Ao : 7,60 ± 0,10 Bo : 9,60 ± 0,10 Ct : 13,5 t P1 Date Code P2 W G Ct Bo F G E Do Po Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 W2(max) : 22,4 N(min) : 50 C : 13,0 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 243.doc Version 1.3 VI TELEFILTER 15.12.2006 Filter specification TFS 243 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 243.doc VI TELEFILTER Version 1.3 Filter specification 15.12.2006 TFS 243 5/5 History Version Reason of Changes Name Date 1.2 - Add history and filter charactreistics - Change construction and stability characteristics Strehl 25.01.2006 1.3 - Change construction Strehl 15.12.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.