VECTRON TFS243

Filename: tfs 243.doc
Version 1.3
VI TELEFILTER
15.12.2006
Filter specification
TFS 243
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
External Coil:
23
0
°C
dBm
310 Ω || -3,4 pF
310 Ω || -3,4 pF
100 nH
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 243 is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 243 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss
(reference level)
ae
Nominal frequency
fN
-
Centre frequency
fC
243,0
fN
±
100
kHz
±
±
±
+
+
400
600
800
1,6
1,6
15
kHz
kHz
kHz
MHz
MHz
MHz
dB
max.
5,0
243,0
MHz
dB
MHz
-
arel
Relative attenuation
fN
fN
fN
fN
fN
fN
3,2
tolerance / limit
…
…
…
…
…
…
fN
fN
fN
fN
fN
fN
±
±
±
+
+
600
800
1,6
25
15
25
kHz
kHz
kHz
MHz
MHz
MHz
max.
3
dB
30
40
50
57
48
55
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
25
36
45
50
45
50
dB
dB
dB
dB
dB
dB
1
µs
max.
Group delay ripple
fN
±
70
kHz
Operating temperature range
OTR
+ 25
Frequency inversion temperature
TCf **
-0,036
µs
- 25 °C ... + 85°C
-
Storage temperature range
Temperature coefficient of frequency
-
1,5
- 30 °C ... + 85°C
°C
ppm/K
2
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fTo(MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 243.doc
Version 1.3
VI TELEFILTER
15.12.2006
Filter specification
TFS 243
2/5
0
-0.5
-20
-1
-30
-1.5
-40
-50
-60
-4
-90
-4.5
242.6
242.8
243
243.2
frequency in MHz
243.4
243.6
243.8
-5
244
4.5
4
3.5
-3
-80
242.4
5
-2
-3.5
242.2
5.5
-2.5
-70
-100
242
6
3
group delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
2.5
2
1.5
1
242.8 242.85 242.9 242.95 243 243.05 243.1 243.15 243.2 243.25
frequency in MHz
Construction and pin connection
(All dimensions in mm)
Pin connection balanced
1
Output
2
Output
3
External Coil
4
Ground
5
Ground
6
Input
7
Input
8
Ground
9
Ground
10
Ground
7,3 Max.
9,3 Max.
1,6 Max.
TFS 243
● U50
Date code
Pin connection unbalanced
1
Output
2
Output RF Return
3
External Coil
4
Ground
5
Ground
6
Input
7
Input RF Return
8
Ground
9
Ground
10
Ground
5,08
2,54
Date code:
U
V
W
...
0,8
R0
,2
Year + week
2006
2007
2008
0,1
1
50 Ω Test circuit balanced
6
1
C1
L1
C2
C3
SAW
7
3
2
L2
C4
L3
4, 5, 8, 9, 10
50 Ω Test circuit unbalanced
6
L1
C1
1
L2
SAW
3
C2
2, 4, 5, 7, 8, 9, 10
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 243.doc
Version 1.3
VI TELEFILTER
15.12.2006
Filter specification
TFS 243
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
2000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,10
F
: 7,50 ± 0,10
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
: 1,50 +0,1/-0
Ao
: 7,60 ± 0,10
Bo
: 9,60 ± 0,10
Ct
: 13,5
t
P1
Date Code
P2
W
G
Ct
Bo
F
G
E
Do
Po
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4
W2(max) : 22,4
N(min)
: 50
C
: 13,0
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 243.doc
Version 1.3
VI TELEFILTER
15.12.2006
Filter specification
TFS 243
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 243.doc
VI TELEFILTER
Version 1.3
Filter specification
15.12.2006
TFS 243
5/5
History
Version
Reason of Changes
Name
Date
1.2
- Add history and filter charactreistics
- Change construction and stability characteristics
Strehl
25.01.2006
1.3
- Change construction
Strehl
15.12.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.