Filename: tfs 115d.doc Version 1.1 VI TELEFILTER 03.02.2006 Filter specification TFS 115D 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 20 0 °C dBm 313 Ω || -24 pF 268 Ω || -29 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 115D is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 115,2 MHz without any tolerance. The given values for both the relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (reference level) ae Nominal frequency fN Pass band ripple p-p Relative attenuation arel fN ± ± ± 4,2 7,5 12,5 dB ... fN ± MHz ... fN MHz ... fN MHz ... fN ± ± ± 1,92 7,5 12,5 25 MHz MHz MHz MHz Absolute Group delay in PB p-p Group delay ripple in PB p-p fN ± dB MHz 1,92 MHz dB max. 1 dB 2,5 dB max. 3 dB dB dB dB min. min. min. 25 35 38 dB dB dB µs max. ns max. 150 max. 10 35 48 60 0,75 100 OTR 0,85 µs ns dBm -10 °C..... +85 °C -40 °C..... +85 °C Storage temperature range Temperature coefficient of frequency 10 0,3 Input power level ** Operating temperature range max. 115,2 PB Passband fN fN fN 6 tolerance / limit TCf *** -22 ppm/K - *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) Maximum value for 10 years operation. ***) ∆fc(Hz) = TCf(ppm/K) x (T - To) x fTo (MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 115d.doc Version 1.1 VI TELEFILTER 03.02.2006 Filter specification TFS 115D 2/5 0 1.77 -1 1.65 -20 -2 1.53 -30 -3 1.41 -40 -4 1.29 -5 1.17 -6 1.05 -70 -7 0.93 -80 -8 0.81 -90 -9 0.69 -50 -60 -100 70.2 79.2 88.2 97.2 106.2 115.2 124.2 frequency in MHz 133.2 142.2 151.2 -10 112.2 160.2 112.8 113.4 114 114.6 115.2 115.8 frequency in MHz 116.4 117 117.6 delay in µs 0 -10 magnitude in dB magnitude in dB Filter characteristic 0.57 118.2 Construction and pin connection (All dimensions in mm) S 115D ● U05 Date code 1 2 3 4 5 6 7 8 9 10 Ground Ground Ground Output Output RF Return Ground Ground Ground Input Input RF Return Date code: U V W ... Year + week 2006 2007 2008 50 Ohm Test circuit L1 9 10 4 SAW L2 5 C2 C1 1, 2, 3, 6, 7, 8 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 115d.doc Version 1.1 VI TELEFILTER 03.02.2006 Filter specification TFS 115D 3/5 Stability characteristics 1. High Temperature (IEC 60068 -3-1) 1,000 hours at +85C 2. Low Temperature (IEC 60068 -3-1) 1,000 hours at – 40C 3. Humidity (IEC 60068 -2-78) 1,000 hours at 85% /85C 4. Thermal Shock ( IEC60068-2-14 ) -55 °C to 125°C / 30 min. each / 10 cycles 5. Vibration (IEC 60068 -2-6) 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans 6. Shock (IEC 60068 -2-27) 500g, 1 ms, half sine wave, 3 shocks each plane 7. Reflow Profile ( defined at specification ) 260°C +/- 5°C for 10 seconds, 2 cycles 8. Solerability 235°C +/- 5°C for 15 seconds, 1 cycle 9. Pullability, Distortion according to MIL-STD 883 method 2004.5 Condition D This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction P1 Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 7,50 ± 0,1 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,50 ± 0,1 Bo : 7,50 ± 0,1 Ct : 13,5 ± 0,1 t Po PIN Marker P2 W G Ct Bo F G E Do Ko Date Code Typ D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 115d.doc Version 1.1 VI TELEFILTER 03.02.2006 Filter specification TFS 115D 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 115d.doc VI TELEFILTER Version 1.1 Filter specification 03.02.2006 TFS 115D 5/5 History : Version Reason of Changes Name Date 1.0 Generate development specification Chilla 21.06.2005 1.1 Generate filter specification terminating impedances added typical values added filter characteristics added test circuit added ROHS compliance added Chilla 03.02.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.