IXYS MMO75

MLO 75
MMO 75
AC Controller Modules
VRSM
VRRM
VDSM
VDRM
V
V
1200 1200
1600 1600
IRMS = 86 A
VRRM = 1200-1600 V
MLO
Type
MMO
MLO 75-12io1
MLO 75-16io1
IRMS
ITRMS
ITAVM
TK = 85°C, 50 - 400 Hz (for single controller)
TVJ = TVJM
TK = 85°C; (180° sine)
ITSM
TVJ = 45°C;
VR = 0
PGM
K1
MMO 75-12io1
MMO 75-16io1
Test Conditions
(dv/dt)cr
G1
G2
Symbol
(di/dt)cr
K2
G1 K1
G1 K1
K2
I2t
MMO 75
K2 G2
Maximum Ratings
86
62
39
A
A
A
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
1150
1230
A
A
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
1000
1100
A
A
TVJ = 45°C
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
6600
6280
A2s
A2s
TVJ = TVJM
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
5000
5020
A2s
A2s
TVJ = TVJM
repetitive, IT = 150 A
f =50 Hz, tP =200 ms
VD = 2/3 VDRM
IG = 0.45 A
non repetitive, IT = ITAVM
diG/dt = 0.45 A/ms
100
A/ms
500
A/ms
1000
V/ms
Features
Thyristor controller for AC (circuit
W1C acc. to IEC) for mains frequency
Direct copper bonded Al2O3 -ceramic
base plate
Isolation voltage 3600 V~
Planar passivated chips
UL registered, E 72873
Long wire leads suitable for PC board
soldering
●
●
●
●
●
●
Applications
Switching and control of single and
three phase AC
Softstart AC motor controller
Solid state switches
Light and temperature control
●
TVJ = TVJM;
VDR = 2/3 VDRM
RGK = ¥; method 1 (linear voltage rise)
TVJ = TVJM
IT = ITAVM
K1 = Cathode 1, G1 = Gate 1
K2 = Cathode 2, G2 = Gate 2
(MLO 36 has no G2 lead)
●
tp = 30 ms
tp = 300 ms
PGAVM
10
5
0.5
W
W
W
VRGM
10
V
TVJ
TVJM
Tstg
-40...+125
125
-40...+125
°C
°C
°C
3000
3600
V~
V~
●
●
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power
cycling
High power density
●
●
VISOL
50/60 Hz, RMS
IISOL £ 1 mA
t = 1 min
t=1s
Md
Mounting torque
(M3)
(UNF 4-32)
Weight
typ.
0.7 ± 0.1
6 ± 0.9
15
●
●
Nm
lb.in.
g
Data according to IEC 60747 and to a single thyristor/diode unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions.
© 2000 IXYS All rights reserved
1-3
MLO 75
MMO 75
Symbol
Test Conditions
Characteristic Values
IR, ID
TVJ = TVJM; VR = VRRM; VD = VDRM
£
5
VT
IT
£
1.4
V
VT0
rT
For power-loss calculations only
0.85
5.0
V
mW
VGT
VD = 6 V;
1.5
1.6
150
200
V
V
mA
mA
= 100 A; TVJ = 25°C
£
£
£
£
TVJ = 25°C
TVJ = -40°C
TVJ = 25°C
TVJ = -40°C
IGT
VD = 6 V;
IGM
tp = 50 ms, f = 60 Hz, IT = ITAVM
VGD
IGD
TVJ = TVJM;
IL
6
mA
0.25
5
V
mA
TVJ = 25°C; tP = 10 ms, VD = 6 V
IG = 0.45 A; diG/dt = 0.45 A/ms
£
300
mA
IH
TVJ = 25°C; VD = 6 V; RGK = ¥
£
100
mA
tgd
TVJ = 25°C; VD = 1/2 VDRM
IG = 0.45 A; diG/dt = 0.45 A/ms
£
2
ms
TVJ = TVJM; IT = 50 A, tP = 200 ms; -di/dt = 10 A/ms
VR = 100 V; dv/dt = 15 V/ms; VD = 2/3 VDRM
typ.
tq
RthJC
RthJK
dS
dA
a
per
per
per
per
1: IGT, TVJ = 125°C
2: IGT, TVJ = 25°C
3: IGT, TVJ = -40°C
V
VG
2
5
Creeping distance on surface
Creepage distance in air
Max. allowable acceleration
150
6
1
4
4: PGAV = 0.5 W
5: PGM = 5 W
6: PGM = 10 W
IGD, TVJ = 125°C
0.1
1
10
100
1000
IG
ms
0.55
0.275
0.75
0.375
K/W
K/W
K/W
K/W
4.5
4.5
50
mm
mm
m/s2
mA
Fig. 1 Gate trigger characteristics
1000
thyristor/diode; DC current
module
thyristor/diode; DC current
module
TVJ = 25°C
µs
tgd
100
typ.
Limit
10
1
10
Dimensions in mm (1 mm = 0.0394")
MLO 75
3
1
A
£
£
VD = 2/3 VDRM
10
100
mA 1000
IG
MMO 75
Fig. 2 Gate trigger delay time
300
TVJ = 125°C
A
TK = 85°C
250
IRMS
200
150
100
50
0
0.01
MMO 75
MLO 75
0.1
s
1
10
t
Fig. 3 Rated RMS current versus time
(360° conduction)
© 2000 IXYS All rights reserved
2-3
MLO 75
MMO 75
1000
110
W
100
90
Ptot
50 Hz
80 % VRRM
A
800
RthKA K/W
80
ITSM
0.3
0.9
1.2
1.5
3
6
70
60
50
600
TVJ = 45°C
400
40
TVJ = 125°C
30
Circuit W1
1 x MMO 75
1 x MLO 75
20
10
200
0
0
0
20
40
60
80
A 0
25
50
75
IRMS
1
125 °C 150
100
TA
10
ms 1000
100
t
Fig. 5 Surge overload current
ITSM, IFSM: Crest value, t: duration
Fig. 4 Load current capability for single phase AC controller
10000
330
W
300
VR = 0V
270
Ptot
240
A2s
TVJ = 45°C
RthKA K/W
I2t
0.1
0.3
0.4
0.5
1
2
210
180
150
TVJ = 125°C
300
120
200
90
Circuit W3
3 x MMO 75
3 x MLO 75
60
30
1000
0
0
20
40
60
80
A 0
25
50
IRMS
75
100
TA
t
Fig. 6 Load current capability for three phase AC controller: 3xMMO 75/MLO 75
Fig. 7 I2t versus time (1-10 ms)
1.0
K/W
0.8
ZthJK
ms 10
1
125 °C 150
70
Constants for
ZthJK calculation:
Rthi / (K/W) ti / (s)
0.6
0.019
0.034
0.498
0.2
0.004
0.02
0.16
0.68
ITAVM
60
DC
180° sin
120°
60°
30°
50
40
RthJK for various
conduction
angles d:
0.4
RthJK / (K/W)
d:
0.751
0.792
0.813
0.841
0.86
DC
180°
120°
60°
30°
0.2
0.0
0.001
A
30°
60°
120°
180°
DC
30
20
10
0
0.01
0.1
1
10
s
t
Fig. 8 Transient thermal impedance junction to heatsink
(per thyristor or diode)
© 2000 IXYS All rights reserved
100
0
25
50
75
100
125 °C
TK
Fig. 9 Maximum on-state current
versus heatsink temperature
3-3