ARTESYN NFS350

NFS350 SERIES
Triple and quad output
•
•
•
•
•
•
•
•
[ 2 YEAR WARRANTY ]
SPECIFICATION
Autoranging input
Overvoltage protection on main output
Short circuit protection with auto restart
Power fail detect
VDE, UL, CSA and BABT approved
Floating, fully adjustable fourth output
12VDC fan connection
Conducted noise to EN55022-A, FCC level B
The NFS350 Series of triple and quad output 350 Watt open frame switchers is
designed for use with larger digital systems. High power density allows a very
compact system design. The advanced topology yields very well regulated outputs
that eliminate the need for inefficient dissipative regulators. The unique floating fourth
output allows a user configurable output voltage, adjustable from 4.5V to 30V, either
positive or negative, at up to 4A. These supplies are approved to UL, CSA, VDE and
BABT and their built-in line filter reduces conducted noise below FCC level B and VDE
0871 level A. NFS350 Series power supplies are suitable for a wide range of general
industrial applications, including process automation, robotics, networking, lighting
systems and telecoms. They are particularly suited for shelf power in miniature rack
systems or subracks.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
Voltage adjustability
+5V output
Auxiliaries
Line regulation
LL to HL, FL
Main output
Total regulation
See Note 4
Overshoot/undershoot
At turn-on
Transient response
+5.1V
(35A to 50A step)
ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS
±5.0%
±3.0%
±0.1% max.
±1.0%
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, level A
EN55022
EN61000-4-2, level
EN61000-4-2, level
EN61000-4-5, level
EN61000-4-4, level
EN61000-4-3, level
EN61000-4-6, level
3
4
3
3
3
3
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
criteria
criteria
criteria
criteria
criteria
criteria
1
1
1
1
1
1
0%
GENERAL SPECIFICATIONS
Temperature coefficient All outputs
Overvoltage protection
+5V output, note 7
Output power limit
150mV max. dev.
500µs recovery
Foldback
See Note 7
Remote sense
Main output
Fan output current
Note C
Efficiency
230VAC, FL
Isolation voltage
Input/output
Input/chassis
Autoranging
Input frequency range
110/230VAC
Safety ground
leakage current
110VAC, 60Hz
230VAC, 50Hz
70% typical
6.25V ±0.5V
Continuous
automatic recovery
Compensate
up to 200mV
12V/0.75A
Approvals and
standards
Variable
Safety
VDE0805, EN60950, IEC950
IEC1010, UL1950, BABT
CSA C22.2 No. 950
Weight
MTBF
90 to 132VAC
180 to 264VAC
3000VAC
1500VAC
Switching frequency
1.9kg (67.07oz)
MIL-HDBK-217E
66,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating, see curve
0°C to +70°C
Non-operating
–40°C to +85°C
0°C to 50°C,
350W
30CFM forced air
50°C to 70°C,
Derate 8.75W/°C
30CFM forced air
Thermal switch
+85°C typical
trip temperature, Note 7
Peak power (60s)
450W
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
47Hz to 63Hz
Input surge current
20ms
5ms
±0.02%/°C
INPUT SPECIFICATIONS
PAGE 1
230VAC, after power failure
230VAC, after PFD flag
550W, min.
Short circuit protection
Input voltage range
Hold-up time
40A
0.6mA, max.
1.6mA, max.
5% to 95% RH
10,000 feet max.
40,000 feet max.
Vibration, 5Hz to 500Hz Three orthogonal axes
random vibration,
10 min. test for each axis
2.4G rms
AC/DC POWER SUPPLIES
|
350W AC
350 Watt
AC/DC universal input switch mode power supplies
OUTPUT CURRENTS
OUTPUT
VOLTAGE
MIN
PEAK
+5.1V
5.0A
70A
50.0A
50mV
±1%
+12.0V
0.3A
20.0A
12.0A
120mV
±1%
–12.0V
0.3A
7.0A
5.0A
120mV
±1%
+5.1V (V1)
5.0A
70A
50.0A
50mV
±1%
+12.0V (V2)
0.3A
20.0A
12.0A
120mV
±1%
–12.0V (V3)
0.3A
7.0A
5.0A
120mV
±1%
0A
–
4.0A
100mV
±1%
+5.1V (V1)
5.0A
70A
50.0A
50mV
±1%
+12.0V (V2)
0.3A
20.0A
12.0A
120mV
±1%
–12.0V (V3)
0.3A
7.0A
5.0A
120mV
±1%
0A
–
4.0A
100mV
±1%
(5)
4.5-16.5 (V4)
15V-30V (V4)
(6)
(1)
RIPPLE
FAN
NFS350-7608P
NFS350-7625P
NFS350-7626P
Term 1
AC Ground
AC Ground
AC Ground
Term 2
AC Neutral
AC Neutral
AC Neutral
Term 3
AC Live
AC Live
AC Live
Term 1
+12V, –12V Ret.
+12V, –12V Ret.
+12V, –12V Ret.
Term 2
–12V
–12V
–12V
Term 3
+12V, –12V Ret.
+12V, –12V Ret.
+12V, –12V Ret.
Term 4
+12V
+12V
+12V
Term 5
+12V
+12V
+12V
Stud 1
+5.1V (V1)
+5.1V (V1)
+5.1V (V1)
Stud 2
+5.1V Return
+5.1V Return
+5.1V Return
Term 1
V4 Return
V4 Return
Term 2
+Aux Output (V4)
+Aux Output (V4)
TB2
TB3
J1
Pin 2
+5.1V Sense
+5.1V Ret. Sense +5.1V Ret. sense
MODEL NUMBER
(4)
NFS350-7608P
NFS350-7625P
NFS350-7626P
1
TB1
+5.1V Sense
TOTAL
REGULATION
Notes
PIN CONNECTIONS
Pin 1
(3)
(2)
+5.1V Sense
+5.1V Ret. Sense
Pin 3
PFD
PFD
PFD
Pin 4
PFD Return
PFD Return
PFD Return
Pin 5
Fan +12V Ret.
Fan +12V Ret.
Fan +12V Ret.
Pin 6
Fan +12V
Fan +12V
Fan +12V
Peak output current lasting less than 60 seconds with duty cycle less than
3%. During peak loading, outputs may go outside of total regulation limits.
Total peak power may not exceed 450W.
2 Forced air, 30 CFM at 1 atmosphere or 350LFM.
3 Figure is peak-to-peak. Output noise measurements are made across a
50MHz bandwidth using a 12” twisted pair terminated with a 47µF
capacitor.
4 Total regulation is defined as the static output regulation at 25°C, including
initial tolerance, line voltage within stated limits, load currents within stated
limits, and output voltages adjusted to their factory settings.
5 Floating output can be adjusted from 4.5V to 16.5V and referenced as
either positive or negative.
6 Floating output can be adjusted from 15V to 30V and referenced as either
positive or negative.
7 Output shorts will cause all outputs to fold back, protecting the supply
from damage. An overvoltage or overtemperature condition will trip the
output crowbar, shorting the outputs and also cause foldback.
When the fault condition is cleared, the supply will automatically recover.
This supply can be configured to latch off in the event of any output short.
Disconnecting line power for 15 seconds will reset the latch. See
mechanical note B.
8 Derating curve is application specific for ambient temperatures > 50°C, for
optimum reliability no part of the heatsink should exceed 90oC and no
semiconductor case temperature should exceed 100oC.
9 Caution: Allow a minimum of 1 second after disconnecting the power
when making thermal measurements.
10 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Power fail detect signal
50ms≤T1≤200ms
T2 will vary with line and load
T3≥5ms
Pout: 350W
PFD output is an open
collector which will sink
≤40mA in the low state
AC INPUT
4.75V
4.75V
5V OUTPUT
HIGH
3.5V MIN
PFD SIGNAL
LOW
0-4 MAX
T3
T1
T2
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1050
Licence No. 3613
UL1950 Reg. File No. E136005
CSA C22.2 No. 950 File No. LR41062C/LR50913/LR101320
Certificate No. PS/603177
http://www.artesyn.com
PAGE 2
AC/DC POWER SUPPLIES
|
350W AC
350 Watt
AC/DC universal input switch mode power supplies
TB1 Connector
Mechanical notes
Kulka P/N 4597A-03 or equivalent.
A Minimum clearance distance to any external grounded metal plate or
chassis is 2mm.
B Removing R15 causes the power supply to latch off in the event of output
short, over-voltage or over-temperature. Removing the line power for 15
seconds will reset the latch.
C Fan current must be subtracted from the available +12V current.
D +5V output adjustment pot.
E +12V output adjustment pot is located on the main PCB, and can be
accessed through this hole. Use a Philips head plastic adjustment tool.
F –12V output adjustment pot is located on the main PCB, and can be
accessed through this hole. Use a Philips head plastic adjustment tool.
G Auxiliary fourth output adjustment pot.
H A standard cover and fan assembly can be added during manufacturing.
Details are on page 65. To order, add suffix ‘CF’ to the model number. e.g.
NFS350-7608PCF.
TB2 Connector
Kulka P/N 4597A-05 or equivalent, 1/4-20 studs, 1/2 inch max. penetration.
TB3 Connector
Use #6 fork terminal connector or equivalent.
J1 Connector
Molex 22-05-3061. Mating connector is Molex 22-01-2067 or equivalent with
Molex 08-50-0114 or equivalent crimp terminal, see Note C.
.250
(6.4)
2.50
(63.5)
6-32 SCREW
THREAD
(4 PL)
TB1
1
1.800
(45.7)
TS1
F1
5A, 250VAC
J1
BUS 1
BUS 2
C8
.77
(19.6)
D
F2
5A
125VAC
5.00
(127)
T1
CONTROL
BOARD
C7
OUTPUT # 4
PCB
F
TB2
PIN 1
9.000
(228.6)
.75
(–)
6-32 SCREW
THREAD
(4 PL)
(19.1 ) TYP.
(+)
THERMAL
SENSOR
TB3
G
TB2
2.5
(63.5)
J1
1.800
(45.7)
.250
(6.4)
10.50
(267)
PIN 1
DERATING CURVE
Output Power (Watts)
350W
FORCED AIR COOLING
(30CFM)
175W
32W MINIMUM LOAD REQUIRED TO MAINTAIN
REGULATION
0W
0°C 10°C
PAGE 3
20°C
30°C
40°C
PIN 1
+ 5.1V
+ 5.1V RET
ALL DIMENSIONS IN INCHES (mm)
32W
PIN 6
50°C
60°C
70°C
1
2
1
B
8-32 SCREW
THREAD
(4 PL)
MAX SCREW PENETRATION
FROM BOTTOM OF CHASSIS
.250"
3.300
(83.8)
TB3
E
A
DS_NFS350_19980401.PDF
http://www.artesyn.com
PAGE 4