MEANWELL LCM-40DA

Features :
¢º
F
SPECIFICATION
MODEL
LCM-40DA
SELECTABLE CURRENT Note.3 350mA
2 ~ 100V
RATED POWER
42W
5%
¡Ó
RIPPLE CURRENT
OUTPUT
500mA
2 ~ 80V
110
M
600mA
700mA
900mA
1050mA
2 ~ 57V
2 ~ 45V
2 ~ 40V
RIPPLE & NOISE (max.) Note.2 700mVp-p
Note.6 1000ms, 80ms / 230VAC at rated power
SETUP, RISE TIME
16ms/230VAC at rated power
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4 180 ~ 295VAC
254 ~ 417VDC
47 ~ 63Hz
FREQUENCY RANGE
¡Ù
¡Ù
POWER FACTOR (Typ.)
PF 0.98/230VAC, PF 0.97/277VAC at rated power (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION Total harmonic distortion will be lower than 20% when output loading is 75% or higher
EFFICIENCY (Typ.)
Note.7 91%
0.21A/230VAC
0.17A/277VAC
COLD START 35A/230VAC
eli
AC CURRENT (Typ.)
INRUSH CURRENT(Tye.)
LEAKAGE CURRENT
<0.5mA / 240VAC
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
110 ~ 130V
Protection type : Shutdown o/p voltage, re-power on to recover
OVER VOLTAGE
OVER TEMPERATURE
90
¢J ¡Ó10¢J (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
¡Ó
TEMP. COMPENSATION
12V @ 50mA for driving fan; Tolerance 5%
By external NTC(not provide with the power supply), please see "Temperature compensation operation"
AUXILIARY POWER
FUNCTION
65V
¡Ó5.0%
CURRENT ACCURACY
PROTECTION
SELV
2 ~ 67V
NO LOAD OUTPUT VOLTAGE (max.) 110V
INPUT
M
mi
DC VOLTAGE RANGE
DIMMING
Please see "Dimming Operation"
SYNCHRONIZATION
Please see "Synchronization Operation"
WORKING TEMP.
-30 ~ +60
¢J (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
¢J
¡Ó0.03%/¢J (0 ~ 50¢J)
Pr
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-40 ~ +80 , 10 ~ 95% RH
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750, ENEC EN61347-1, EN61347-2-13,EN62384 independent approved
DALI STANDARDS
IEC62386-01, 102, 207
SAFETY & WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
EMC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C( 35% rated power) ; EN61000-3-3
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
series
Output current level selectable by DIP S.W.
180~295VAC input only
Built-in active PFC function
Protections: Short circuit / Over voltage / Over temperature
Cooling by free air convection
Fully isolated plastic case
Class
power unit, no FG
Built-in DALI interface and push dimming function
Built-in 12V/50mA auxiliary output
IP20 design
Temperature compensation function by external NTC
No load power consumption <1.2W@AC always on (Note 8)
Power supplies synchronization function up to 10 units
Suitable for LED lighting applications
3 years warranty
na
¡¡E¡½
E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡
E
LCM-40DA
ry
40W Multiple-Stage Output Current LED Power Supply
¢J
¡Ù
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547 light industry level (surge 2KV), criteria A
K hrs min. MIL-HDBK-217F (25 )
123.5*81.5*23mm (L*W*H)
0.24Kg
¢J
¢J
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf parallel capacitor.
3. Please see "DIP switch table".
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Efficiency is measured at 500mA/80V output set by DIP switch.
8. No load power consumption<1.2W is measured at 180~277VAC.
File Name:LCM-40DA-SPEC 2012-09-11
ry
LCM-40DA
40W Multiple-Stage Output Current LED Power Supply
Mechanical Specification
Case No.
123.5
6.75
6.75
110
£r4.
2
6.75
AC/L
AC/N
2-
PUSH
DA+
DA-
TB3/TB4
1
SYN.
2
3
4
5
6
68
81.5
Unit:mm
na
6.75
series
CN101
CN100
+
Vo
-
ON
1 2 3 4 5 6
39.3
65.5
7.8
7.8
2- M3
4
mi
Terminal Pin No. Assignment(TB3/TB4) :
23
Pin No.
1
2
3
Assignment
+12Vaux.
-12Vaux.
+NTC
Assignment
-NTC
DIM+
DIM-
Pin No.
4
5
6
SYN. Connector(CN101/CN100):JST B2B-XH or equivalent
Pin No.
1,3
2,4
eli
Block Diagram
EMI FILTER
&
RECTIFIERS
I/P
POWER
SWITCHING
PFC
CIRCUIT
O.L.P.
PFC
CONTROL
O.T.P.
Pr
+V
-V
DIM+
DIM-
MCU
DETECTION
CIRCUIT
80
70
LOAD (%)
LOAD (%)
RECTIFIERS
&
FILTER
90
20
40
+12Vaux
100
40
30
RECTIFIERS
Static Characteristics
60
15
JST SXH-001T-P0.6
or equivalent
O.V.P.
80
0
Terminal
JST XHP
or equivalent
O.L.P.
100
-15
Mating Housing
PFC fosc : 60KHz
PWM fosc : 80KHz
PWM
CONTROL
Derating Curve
-30
Assignment
+
-
50
¢J
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
180
190
200
210
220
230 240
250
260
270
280
295
INPUT VOLTAGE (V) 60Hz
File Name:LCM-40DA-SPEC 2012-09-11
ry
40W Multiple-Stage Output Current LED Power Supply
DIP Switch Table
LCM-40DA
series
DIP S.W.
1
2
3
4
5
6
350mA
----
----
----
----
----
----
500mA
ON
----
----
----
----
----
600mA(Factory Setting) ON
ON
----
----
----
----
700mA
ON
ON
ON
----
----
ON
900mA
ON
ON
ON
ON
----
ON
1050mA
ON
ON
ON
ON
ON
ON
Io
mi
Power Factor Characteristic
na
LCM-40DA is a multiple-stage output current supply, selection of output current through DIP switch as table below.
Constant Current Mode
0.99
0.96
0.93
0.9
350
0.87
0.84
500
0.81
600
0.78
PF
PF
Constant Current Mode
700
0.75
900
0.72
1050
0.66
0.63
eli
0.69
10% 20% 30%
40% 50% 60%
70% 80% 90% 100%
0.99
0.96
0.93
0.9
0.87
0.84
0.81
0.78
0.75
0.72
0.69
0.66
0.63
0.6
0.57
0.54
0.51
0.48
0.45
10% 20% 30%
(40W)
LOAD
(230Vac Input)
350
500
600
700
900
1050
40% 50% 60%
70% 80% 90% 100%
(40W)
LOAD
(277Vac Input)
EFFICIENCY vs LOAD
LCM-40DA series possess superior working efficiency that up to 91% can be reached in field applications.
95.0%
95.0%
90.0%
Pr
90.0%
85.0%
80.0%
350
75.0%
500
70.0%
600
65.0%
700
60.0%
900
55.0%
1050
50.0%
45.0%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
(230Vac Input)
EFFICIENCY (%)
EFFICIENCY (%)
85.0%
80.0%
350
75.0%
500
70.0%
600
65.0%
700
60.0%
900
55.0%
1050
50.0%
45.0%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
(277Vac Input)
File Name:LCM-40DA-SPEC 2012-09-11
ry
40W Multiple-Stage Output Current LED Power Supply
DIMMING OPERATION
Ignore
To avoid reaction on AC spike
<0.05 sec.
Short push
Push to turn ON-OFF
0.1~1 sec.
Long push
Dimming up or down
1.5~10 sec.
Reset push
Setting light to 100%
>11 sec.
series
na
¡° PUSH dim(primary side)
LCM-40DA
LCM-40DA
DADA+
PUSH
AC/N
AC/L
mi
¡EMaximum number of drivers up to 10 pcs.
¡ Maximum length of the cable, from push button to last driver is 15 meter.
E
¡ Factory setting at 100%.
E
¡ When the light is lower than 10% it will always dim up, or when the light output is higher than 90% it will always dim down.
E
Push Button
AC/N
AC/L
Warning: The pushbutton can only be connected in between the PUSH terminal of LCM-40DA and AC/L (brown or black color). It would cause short circuit if
it is connected to AC/N.
¡° DALI interface(primary side)
¡EDALI protocol including 16 groups and 64 addresses.
¡ First step is fixed at 1% light output.
E
SYNCHRONIZATION OPERATION
LCM-40DA
(Master)
SYN.
- -
+
+
+
+
SYN.
- -
LCM-40DA
(Slave 1)
SYN.
- -
Pr
LCM-40DA
(Slave 2)
+
+
eli
¡E10 drivers(max.) synchronization (1 master + 9 slaves)
¡ Maximum length of the cable from first driver to last driver is 15 meter.
E
File Name:LCM-40DA-SPEC 2012-09-11
ry
40W Multiple-Stage Output Current LED Power Supply
TEMPERATURE COMPENSATION OPERATION
NTC derating curve
series
na
105
LCM-40DA
100
£[
£
[
470KO
470K
£[
220KO
220K
95
Output Io (%)
330KO
330K
90
85
80
75
65
55
60
65
70
mi
70
75
80
85
90
95
Sensed Temperature(degree)
LCM-40DA have the built-in temperature compensation function (T ¡÷, Io¡ö). By connecting a temperature sensor (NTC resistor) between the NTC +/terminal of LCM-40DA and the detecting point on the lighting system or the surrounding environment, output current of LCM-40DA could be
correspondingly changed to ensure the long life of LED.
1.LCM-40DA can still be operated well when the NTC resistor is not connected and the value of output current will be the current level that you set
through the DIP switch.
2.
220K
330K
470K
Output Current
¢J, 100% of the rated current (corresponds to the setting current level)
¢ , output current begin to reduce, details please refer to the curve.
J
< 70¢J, 100% of the rated current (corresponds to the setting current level)
> 70¢J, output current begin to reduce, details please refer to the curve.
< 80¢J, 100% of the rated current (corresponds to the setting current level)
> 80¢J, output current begin to reduce, details please refer to the curve.
< 60
> 60
eli
NTC resistance
Pr
Notes: 1. MW does not offer the NTC resistor and all the data above are measured by using THINKING TTC03 series.
2. If other brands of NTC resistor is applied,please check the temperature curve first.
3. Synchronization function of the power supply will be invalid when the "temperature compensation" function is in use.
File Name:LCM-40DA-SPEC 2012-09-11