Electrical Specifications
Key Features:
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• 15W Output Power
Parameter
• Universal 85-264 VAC Input
Input Voltage Range
• EN 60950 Compliant
Input Frequency
• Single, Dual & Triple Outputs Input Current
• Meets EN55022 B
Inrush Current
• >200 kHour MTBF
• Compact PC Mount Case
EMI
Safety Ground Leakage Current
Conditions
Min.
Typ.
Max.
85
264
120
370
47
63
See Model Selection Guide
115 VAC
10.0
230 VAC
20.0
Meets CISPR Pub. 22/FCC Class B
115 VAC
0.1
230 VAC
0.3
Units
VAC
VDC
Hz
A Pk
mA
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
RoHS Compliant
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Overload Protection
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
±2.0
±0.5
See Model Selection Guide
50
115 VAC
20
230 VAC
80
±0.02
Continuous (Autorecovery)
Typ. 110% of Output Power
Max.
Units
%
mV Pk - Pk
mSec
%/°C
General
Parameter
Isolation Voltage
EMI/RFI
EMC Compliance
MicroPower Direct
Switching Frequency
292 Page Street
Suite D
Stoughton, MA 02072
USA
Environmental
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Input to Output
Input to Ground
Output to Ground
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Conditions
Min.
3,000
1,500
500
Typ.
Max.
VAC
EN 55022 Level B
IEC/EN 61000-4-2 Level 3
IEC/EN61000-4-3
IEC/EN 61000-4-4 Level 3 2 kV
IEC/EN 61000-4-5 Level 3 1kV/2 kV
150
kHz
Max.
+70
+90
-25
+105
Free Air Convection (See Derating Curve)
RH, Non-condensing
85
Ambient
Case
Units
Min.
-20
Typ.
+25
Units
°C
°C
°C
%
Physical
Case Size
Case Material
Weight
2.44 x 1.77 x 0.88 Inches (62.0 x 45.0 x 22.5 mm)
Non-Conductive Black Plastic (UL94-V0)
5.11 Oz (145g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals (Pending)
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
200
IEN 60950, IEC 60950
IEN 60950, IEC 60950
Max.
Units
kHours
Model Selection Guide
Model
Number
MPM-15S-03
MPM-15S-05
MPM-15S-12
MPM-15S-15
MPM-15S-24
MPM-15S-48
MPM-15D-05
MPM-15D-12
MPM-15D-15
MPM-15T-0505
MPM-15T-0512
MPM-15T-0515
MPM-15T-0524
Input
Current (A)
Voltage
115 VAC 230 VAC
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
(VDC)
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
3.3
5.0
12.0
15.0
24.0
48.0
+5.0
+12.0
+15.0
5.0
5.0
5.0
5.0
Output 2 (Vout 2)
Output 3 (Vout 3)
Output 1 (Vout 1)
Current (A)
Current (A)
Current (A) Efficiency
Over Volt.
Over Volt.
Voltage
Voltage
(%, Typ)
Load Protection (VDC)
Load Protection (VDC)
Load
Typ.
Typ.
Typ.
(VDC)
(VDC)
Reg.
Reg.
Reg.
3.000 ±1.0%
6.5
80
2.800 ±1.0%
6.5
80
1.250 ±1.0%
20.0
80
1.000 ±1.0%
20.0
80
0.625 ±1.0%
30.0
80
0.320 ±1.0%
30.0
80
+1.50 ±2.0%
6.5
-5.0 -1.50 ±2.0%
6.5
80
+0.65 ±2.0%
20.0
-12.0 -0.65 ±2.0%
20.0
80
+0.50 ±2.0%
20.0
-15.0 -0.50 ±2.0%
20.0
80
2.60 ±3.0%
6.5
+5.0 +0.20 ±5.0%
-5.0 -0.20 ±5.0%
80
2.00 ±3.0%
6.5
+12.0 +0.20 ±5.0%
-12.0 -0.20 ±5.0%
80
1.80 ±3.0%
6.5
+15.0 +0.20 ±5.0%
-15.0 -0.20 ±5.0%
80
2.00 ±3.0%
6.5
+24.0 +0.10 ±5.0%
-24.0 -0.10 ±5.0%
80
Notes:
1. Load regulation is measured for an output change of 10% to 90% at nominal input
line. For multiple output models, the loads are balanced.
2. The MPM-15 series is specified for operation over the wide operating temperature
range of -20°C to +55°C without derating. For operation over +55°C, derate the
power linearly by 3.75%/°C from +55°C to +70°C.
3. It is recommended that a fuse be used on the input of a power supply for protection.
For the MPM-15 series, a 2A/250 VAC slow blow should be used.
Typical Connection
Mechanical Dimensions
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Pin Connections
Pin
1
2
3
4
5
6
7
8
Single
Dual
Typical Component Values
Triple
Vout
C1, C3, C5
C2, C4, C6
Fuse
TVS
3.3
330 ~ 1,000 µF/16V
P6KE6.8A
5.0
330 ~ 1,000 µF/16V
P6KE6.8A
2A/
12.0
220 µF/25V
P6KE16A
0.1 µF/50V
250 VAC
Ceramic
15.0
220 µF/25V
P6KE20A
Slow Blow
24.0
120 µF/35V
P6KE33A
48.0
68 µF/63V
P6KE62A
Notes:
1. C1, C3 and C5 are high frequency, low resistance electrolytic capacitors.
Refer to the suppliers specifications for capacitance/current ratings.
2. Voltage derating on all capacitors should be
80% or higher.
3. C2, C4 and C6 eliminate high frequency noise.
4. The TVS is recommended to protect load
circuitry in the event of a module failure.
No Pin
AC-Ground AC-Ground
AC-Neutral AC-Neutral AC-Neutral
AC-Line
AC-Line
AC-Line
-Vo 1
-Vo 2
-Vo 1
No Pin
No Pin
+Vo 1
No Pin
Common
-Vo 2
No Pin
No Pin
Common
+Vo 1
+Vo 1
+Vo 2
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]