MPM-15 Series Compact, 15W PC Mount Single, Dual & Triple Out AC/DC Power Supplies Electrical Specifications Key Features: Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input • 15W Output Power Parameter • Universal 85-264 VAC Input Input Voltage Range • EN 60950 Compliant Input Frequency • Single, Dual & Triple Outputs Input Current • Meets EN55022 B Inrush Current • >200 kHour MTBF • Compact PC Mount Case EMI Safety Ground Leakage Current Conditions Min. Typ. Max. 85 264 120 370 47 63 See Model Selection Guide 115 VAC 10.0 230 VAC 20.0 Meets CISPR Pub. 22/FCC Class B 115 VAC 0.1 230 VAC 0.3 Units VAC VDC Hz A Pk mA Output Parameter Output Voltage Output Current Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz) RoHS Compliant Hold-Up Time Temperature Coefficient Short Circuit Protection Overload Protection Conditions Min. Typ. See Model Selection Guide See Model Selection Guide ±2.0 ±0.5 See Model Selection Guide 50 115 VAC 20 230 VAC 80 ±0.02 Continuous (Autorecovery) Typ. 110% of Output Power Max. Units % mV Pk - Pk mSec %/°C General Parameter Isolation Voltage EMI/RFI EMC Compliance MicroPower Direct Switching Frequency 292 Page Street Suite D Stoughton, MA 02072 USA Environmental T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Input to Output Input to Ground Output to Ground Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Conditions Min. 3,000 1,500 500 Typ. Max. VAC EN 55022 Level B IEC/EN 61000-4-2 Level 3 IEC/EN61000-4-3 IEC/EN 61000-4-4 Level 3 2 kV IEC/EN 61000-4-5 Level 3 1kV/2 kV 150 kHz Max. +70 +90 -25 +105 Free Air Convection (See Derating Curve) RH, Non-condensing 85 Ambient Case Units Min. -20 Typ. +25 Units °C °C °C % Physical Case Size Case Material Weight 2.44 x 1.77 x 0.88 Inches (62.0 x 45.0 x 22.5 mm) Non-Conductive Black Plastic (UL94-V0) 5.11 Oz (145g) Reliability Specifications Parameter MTBF Safety Standards Safety Approvals (Pending) Conditions Min. Typ. MIL HDBK 217F, 25°C, Gnd Benign 200 IEN 60950, IEC 60950 IEN 60950, IEC 60950 Max. Units kHours Model Selection Guide Model Number MPM-15S-03 MPM-15S-05 MPM-15S-12 MPM-15S-15 MPM-15S-24 MPM-15S-48 MPM-15D-05 MPM-15D-12 MPM-15D-15 MPM-15T-0505 MPM-15T-0512 MPM-15T-0515 MPM-15T-0524 Input Current (A) Voltage 115 VAC 230 VAC 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 (VDC) 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 3.3 5.0 12.0 15.0 24.0 48.0 +5.0 +12.0 +15.0 5.0 5.0 5.0 5.0 Output 2 (Vout 2) Output 3 (Vout 3) Output 1 (Vout 1) Current (A) Current (A) Current (A) Efficiency Over Volt. Over Volt. Voltage Voltage (%, Typ) Load Protection (VDC) Load Protection (VDC) Load Typ. Typ. Typ. (VDC) (VDC) Reg. Reg. Reg. 3.000 ±1.0% 6.5 80 2.800 ±1.0% 6.5 80 1.250 ±1.0% 20.0 80 1.000 ±1.0% 20.0 80 0.625 ±1.0% 30.0 80 0.320 ±1.0% 30.0 80 +1.50 ±2.0% 6.5 -5.0 -1.50 ±2.0% 6.5 80 +0.65 ±2.0% 20.0 -12.0 -0.65 ±2.0% 20.0 80 +0.50 ±2.0% 20.0 -15.0 -0.50 ±2.0% 20.0 80 2.60 ±3.0% 6.5 +5.0 +0.20 ±5.0% -5.0 -0.20 ±5.0% 80 2.00 ±3.0% 6.5 +12.0 +0.20 ±5.0% -12.0 -0.20 ±5.0% 80 1.80 ±3.0% 6.5 +15.0 +0.20 ±5.0% -15.0 -0.20 ±5.0% 80 2.00 ±3.0% 6.5 +24.0 +0.10 ±5.0% -24.0 -0.10 ±5.0% 80 Notes: 1. Load regulation is measured for an output change of 10% to 90% at nominal input line. For multiple output models, the loads are balanced. 2. The MPM-15 series is specified for operation over the wide operating temperature range of -20°C to +55°C without derating. For operation over +55°C, derate the power linearly by 3.75%/°C from +55°C to +70°C. 3. It is recommended that a fuse be used on the input of a power supply for protection. For the MPM-15 series, a 2A/250 VAC slow blow should be used. Typical Connection Mechanical Dimensions Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Pin Connections Pin 1 2 3 4 5 6 7 8 Single Dual Typical Component Values Triple Vout C1, C3, C5 C2, C4, C6 Fuse TVS 3.3 330 ~ 1,000 µF/16V P6KE6.8A 5.0 330 ~ 1,000 µF/16V P6KE6.8A 2A/ 12.0 220 µF/25V P6KE16A 0.1 µF/50V 250 VAC Ceramic 15.0 220 µF/25V P6KE20A Slow Blow 24.0 120 µF/35V P6KE33A 48.0 68 µF/63V P6KE62A Notes: 1. C1, C3 and C5 are high frequency, low resistance electrolytic capacitors. Refer to the suppliers specifications for capacitance/current ratings. 2. Voltage derating on all capacitors should be 80% or higher. 3. C2, C4 and C6 eliminate high frequency noise. 4. The TVS is recommended to protect load circuitry in the event of a module failure. No Pin AC-Ground AC-Ground AC-Neutral AC-Neutral AC-Neutral AC-Line AC-Line AC-Line -Vo 1 -Vo 2 -Vo 1 No Pin No Pin +Vo 1 No Pin Common -Vo 2 No Pin No Pin Common +Vo 1 +Vo 1 +Vo 2 MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]