ARTESYN NAN55

NAN55 SERIES
Single, dual and triple output
•
•
•
•
•
•
•
The NAN55 series is a 55W universal input AC/DC power supply on a 5 x 3 inch
card with a maximum component height of 1.2 inches for use in 1U
applications. The NAN55 series is available in four standard models, in the
traditional 40W standard footprint, but with increased load capability on the
main 5V output. This ensures suitability for logic and processor applications that
have larger load requirements than existing 40W designs due to increased
functionality. The NAN55 provides 45W of output power with free air convection
cooling which can be boosted to 55W with 5CFM of air. Standard features
include overvoltage and short circuit protection. The series, with full international
safety approval and the CE mark, meets conducted emissions EN55022 level B.
The NAN55 series is designed for use in low power data networking and
computer applications such as hubs, routers, POS terminals, internet servers
and cable modems.
[ 2 YEAR WARRANTY ]
SPECIFICATION
5.0 x 3.0 x 1.2 inch package (1U applications)
Industry standard package
Overvoltage and short circuit protection
45W with free air convection
55 Watts with 5CFM
EN55022, EN55011 conducted emissions level B
UL, VDE and CSA safety approvals
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Output Power
Natural convection
5CFM forced air
45W max.
55W max.
Rise time
At turn-on
1.0s max.
Total regulation
See Note 5
See table
Overshoot/undershoot
At turn-on, min. load
Transient response
Single: +5V
(7.5 to 10A step)
Multi: +5V
(3.5 to 6.6A step)
Multi: +12V
(0.75 to 1.5A step)
Triple: -12V
(0.10 to 0.20A step)
5%
5.0% max. dev.;
1ms recovery
Temperature coefficient
Overvoltage protection
Single output
Dual and triple output
Short circuit protection
Hold-up time
120VAC, 60Hz
Efficiency
120VAC
Isolation voltage
Input/output
Input/chassis
Switching frequency
5.6 to 6.9V
5.5 to 7.0V
Approvals and
standards (See Note 9)
1A
(See Note 5)
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
Level B
Level A
criteria 1
criteria 1
criteria 1
criteria 1
criteria 2
criteria 1
GENERAL SPECIFICATIONS
±0.02%/°C
Yes, with auto-restart
Minimum output current Models: 7605 and 7628
Models: 7629 and 7608
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
70% min. @ 45W
3000VAC
1500VAC
25kHz min.
EN60950, VDE0805, UL1950
CSA C22.2 No. 950
Weight
MTBF (See Note 2)
12ms @ 55W
200g (7.06oz)
MIL-HDBK-217F
150,000 Hours
ENVIRONMENTAL SPECIFICATIONS
INPUT SPECIFICATIONS
Input voltage range
Universal input
Input frequency range
120VAC, cold start
230VAC, cold start
Safety ground
leakage current
132VAC, 60Hz
240VAC, 50Hz
Input current
120VAC
230VAC
PAGE 1
Operating ambient
0°C to +50°C
Non-operating
-40°C to +85°C
0°C to 50°C ambient,
45W
convection cooled
50°C to 70°C,
Derate linearly
ambient conv. cooled
to 50%
load at 70°C
Peak (0°C to 50°C) max. 60s
55W
Relative humidity
Non-condensing
1.4A rms max.
0.8A rms max.
Altitude
Operating
Non operating
250VAC H 3A
Vibration
Three orthogonal
2.4G rms approx.
axes, random
5Hz to 500Hz
vibration, 10 minute
test for each axis
Shock
MIL-STD-810E
47Hz to 440Hz
Input surge current
Input fuse
Thermal performance
(See Notes 7, 8)
90 to 264VAC
100 to 370VDC
20A
40A
0.2mA
0.4mA
5% to 95% RH
10,000 feet max.
30,000 feet max.
516.4 Part IV
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
|
45-55W AC/DC
45 to 55 Watt
AC/DC universal input switch mode power supplies
OUTPUT CURRENT
OUTPUT
VOLTAGE
(5)
MIN
MAX
(1)
FAN
RIPPLE
(3)
TOTAL
(4)
REGULATION
+ 5.2V (IA)
0A
6.5A
7.2A
50mV
±2.0%
+12.1V (IB)
0A
1.2A
1.5A
120mV
±5.0%
–12V (IC)
0A
0.1A
0.2A
120mV
±5.0%
+ 5.2V (IA)
1.0A
7.0A
8.0A
50mV
±2.0%
+12V (IB)
0A
0.35A
0.5A
120mV
±5.0%
–12V (IC)
0A
0.35A
0.5A
120mV
±5.0%
+5.2V (IA)
0A
6.5A
7.2A
50mV
±2.0%
+12.1V (IB)
0A
1.1A
1.1A
120mV
±5.0%
+5V
1.0A
9.0A
11.0A
50mV
±3.0%
MODEL NUMBER
(5)
(10)
NAN55-7608
NAN55-7628
NAN55-7629
NAN55-7605
Notes
Mechanical notes
1
2
A A non-metallic stand-off is required in one hole as specified in the
mechanical drawing to meet safety requirements.
B Maximum component height is 1.2 inches (30.48mm).
C A standard L-bracket and cover is available for mounting, which contains
all screws, connectors and necessary mounting hardware. Details are on
page 72. Order part number ‘NAL40 COVER KIT’.
INPUT
PIN CONNECTIONS
J1
Pin 1
AC Line
Pin 2
No Connection
Pin 3
AC Neutral
P1
Pin 1
Safety Ground
J2
P1
P2
P3
P4
P5
P6
OUTPUT PIN CONNECTIONS
SINGLE
DUAL
TRIPLE
+Vout
V(B)
V(B)
+Vout
V(A)
V(A)
+Vout
V(A)
V(A)
Return
Return
Return
Return
Return
Return
Return
Return
V(C)
0.08R (2.03) OBROUND SLOT TYP.
C4
CR2
T1
3.00
(76.2)
J2
Q1
F1
L
1
P1
0.23
(5.84)
0.20
(5.08)
2.60
(66.04)
1
CR3
J1
N
T1
F3A 250VAC
Natural convection cooling (45W maximum).
A 5 Watt minimum load is recommended to achieve design MTBF. See
derating curve.
3 Forced air, 5CFM at 1 atmosphere, 55W maximum for all models.
4 Figure is peak-to-peak. Output noise measurements are made across a
50MHz bandwidth using a 12 inch twisted pair, terminated with a 47µF
capacitor.
5 For NAN55-7608 and NAN55-7629, to maintain stated regulation on +5.2V,
+12.1V then:
0.25 ≤ IA / IB ≤ 25. Also to maintain stated regulation on -12V of
NAN55-7608 then:
I(A) ≥ 0.5A
For NAN55-7628, to maintain stated regulation on the ±12V then:
I(A) ≥ 1.0A
6 Output voltages are not adjustable.
7 For optimum reliability, no part of the heatsink should exceed 120°C, and
no semiconductor case temperature should exceed 135°C.
8 Caution: allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
9 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
10 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool
at http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
2.54
(64.52)
4.54
(115.32)
4.60
(116.84)
0.23
(5.84)
0.20
(5.08)
5.00
(127.00)
ALL DIMENSIONS IN INCHES (mm)
DERATING CURVE
Output Power (Watts)
55W
5 CFM FORCED AIR COOLING
45W
AC (J1) connector
Molex 26-60-4030 or equivalent. Recommend Molex 09-50-3031 mating
connector with appropriate crimp terminals.
DC (J2) connector
Molex 26-60-4060 or equivalent. Recommend Molex 09-50-3061 mating
connector with appropriate crimp terminals.
NATURAL
CONVECTION
COOLING
5W
International Safety Standard Approvals
22.5W
5W MIN. LOAD IS REQUIRED TO ACHIEVE
DESIGN MTBF
0°C 10°C
EN60950/EN41003 File No. 10401-3336-1100/A1C Licence No. 98705
27.5W
20°C
30°C
40°C
50°C
60°C
70°C
Available Output Power V's Ambient Temperature
UL1950 File No. E136005
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
http://www.artesyn.com
PAGE 2
ds_nan55_20050825.PDF
CSA C22.2 No. 950 File No. LR41062C