Features ● ● ● ● ● ● ● 4:1 Wide Input Voltage Range 10 Watts Output Power 1.6kVDC Isolation Fixed Operating Frequency Six-Sided Continuous Shield Standard 50.8 x25.4x10.2mm Package Efficiency to 84% POWERLINE DC/DC-Converter RP10S_DEW Series 10 Watt 2” x 1” Package Single & Dual Output Selection Guide 24V and 48V Input Types Part Number Input Range VDC Output Voltage VDC Output Current mA Input (4) Current mA Efficiency(5) Capacitive(6) Load max. % µF RP10-2405SEW 9-36 5 2000 548 80 4700 RP10-2412SEW 9-36 12 830 532 82 690 RP10-2415SEW 9-36 15 670 551 80 470 RP10-4805SEW 18-75 5 2000 274 80 4700 RP10-4812SEW 18-75 12 830 259 84 690 RP10-4815SEW 18-75 15 670 262 84 470 RP10-2405DEW 9-36 ±5 ±1000 548 80 ±680 RP10-2412DEW 9-36 ±12 ±416 547 80 ±330 RP10-2415DEW 9-36 ±15 ±333 548 80 ±110 RP10-4805DEW 18-75 ±5 ±1000 271 81 ±680 RP10-4812DEW 18-75 ±12 ±416 281 78 ±330 RP10-4815DEW 18-75 ±15 ±333 270 81 ±110 * add suffix /M M2 for higher efficiencies and extended temperature range. * add /PP for CTRL function with Positive Logic (1=ON, 0=OFF) N for CTRL function with Negative Logic (0=ON, 1=OFF) * add /N 224 July-2006 www.recom-international.com RP10-S_DEW Series POWERLINE DC/DC-Converter Derating-Graph (Ambient Temperature) RP10-2405SEW With Heat Sink RP10-2405SEW 125 125 100 100 75 Natural Convection Output Power (%) Output Power (%) 75 50 25 0 -25 -10 0 50 60 70 80 90 100 Ambient Temperature Range (°C) -10 0 50 60 70 80 90 100 Ambient Temperature Range (°C) 75 100 100 75 75 50 Natural Convection 25 0 -25 -10 0 50 60 70 80 90 100 Ambient Temperature Range (°C) 74 RP10-2405SEW/M2 50 60 70 Ambient Temperature Range (°C) Output Power (%) 80 90 100 -10 0 50 60 70 80 90 100 78 RP10-2405SEW/M2 With Heat Sink 50 Natural Convection 25 0 -40 -25 -10 0 50 60 70 80 90 100 Ambient Temperature Range (°C) 75 RP10-2405DEW/M2 125 100 RP10-2405DEW/M2 With Heat Sink 100 75 Natural Convection Output Power (%) 50 0 -25 75 Natural Convection 0 -40 -25 -10 0 75 Natural Convection 25 100 25 125 50 125 75 50 RP10-2405DEW With Heat Sink Ambient Temperature Range (°C) 100 Output Power (%) 0 -25 125 125 Output Power (%) 25 125 Output Power (%) Output Power (%) RP10-2405DEW Natural Convection 50 25 0 -40 -25 -10 0 50 60 70 80 90 100 Ambient Temperature Range (°C) 74 50 Natural Convection 25 0 -40 -25 -10 0 50 60 70 Ambient Temperature Range (°C) 80 90 100 78 Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical customer service at [email protected] www.recom-international.com July-2006 225 RP10-S_DEW Series POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25°C unless otherwise noted) Input Voltage Range 24V nominal input 48V nominal input Input Filter Input Surge Voltage (100 ms max.) 9-36VDC 18-75VDC Pi Type 24V Input 48V Input 50VDC 100VDC Input Reflected Ripple (nominal Vin and full load) 30mAp-p Start Up Time (nominal Vin and constant resistor load) 20ms typ. Remote ON/OFF (Optional. See Note 7) (Positive logic) (Negative logic) Remote OFF input current DC-DC ON Open or 3.5V < Vr < 12V DC-DC OFF Short or 0V < Vr < 1.2V DC-DC ON Short or 0V < Vr < 1.2V DC-DC OFF Open or 3.5V < Vr < 12V Nominal input Output Power 10W max. Output Voltage Accuracy (full Load and nominal Vin) ±2% Minimum Load (see Note 1) 10% of full load Line Regulation (low line, high line at full load) Load Regulation (25% to 100% full load) ±1% Single Dual Cross Regulation (asymmetrical load 25%/100% full load) Ripple and Noise (20MHz bandwith) ±1% ±2% ±5% Single 50mVp-p Dual 75mVp-p Temperature Coefficient ±0.02%/°C max. Transient Response (25% load step change) Over Voltage Protection Zener diode clamp 20mA 500µs 5V output 12V output 15V output Over Load Protection (% of full load at nominal Vin) 6.2V 15V 18V 150% typ Short Circuit Protection Hiccup, automatic recovery Efficiency see „Selection Guide“ table Isolation Voltage 1600VDC min. Isolation Resistance 1 GΩ min. Isolation Capacitance 300pF max. Operating Frequency 300kHz typ. Operating Temperature Range Standard -25°C to +85°C(with derating) (Reference Derating Curve) (see Note 9) M2 -40°C to +85°C(with derating) Maximum Case Temperature +100°C Storage Temperature Range -55°C to +105°C Thermal Impedance Natural convection 12°C/Watt (see Note 8) Natural convection with Heat Sink 10°C/Watt Thermal Shock MIL-STD-810D continued on next page 226 July-2006 www.recom-international.com RP10-S_DEW Series POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25°C unless otherwise noted) Vibration 10-55Hz, 2G, 30 Min. along X, Y and Z Relative Humidity 5% to 95% RH Case Material Nickel plated copper Base Material Non-conductive black plastic Potting Material Conducted Emissions (see Note 10) Radiated Emissions ESD Radiated Immunity Fast Transient Surge Conducted Immunity Epoxy (UL94-V0) EN55022 EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Weight Level A Level A Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 27g Dimensions 50.8 x 25.4 x 10.2mm 1976 x 103 hours MTBF (see Note 2) Notes : 1. The RP10 (W) series required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listedspecification. 2. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment). 3. Simulated source impedance of 12µH. 12µH inductor in series with +Vin. 4. Maximum value at nominal input voltage and full load of standard type. 5. Typical value at nominal input voltage and full load. 6. Test by minimum Vin and constant resistor load. 7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input. Positive logic ON/OFF is marked with suffix-P (eg. RP10-2405SEW/P) Negative logic ON/OFF is marked with suffix-N (eg. RP10-2405SEW/N). If no suffix is specified, the control pin will be omitted. 8. Heat sink is optional and P/N: 7G-0020A. 9. M2 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard version. 10. See application notes for EMI-filtering. www.recom-international.com July-2006 227 RP10-S_DEW Series POWERLINE DC/DC-Converter Package Style and Pinning (mm) 3rd angle projection 50.80 25.40 10.20 dia. 1.0 5.6 2.50 5.10 20.30 15.20 Pin Connections 3 1 2 6 Bottom View 10.20 4 10.20 5 12.70 Pin # Single 1 +Vin 2 -Vin 3 +Vout 4 No Pin 5 -Vout 6* CTRL* * Optional. See Note 7 Dual +Vin -Vin +Vout Com -Vout CTRL* Pin Pitch Tolerance ±0.35 mm 228 July-2006 www.recom-international.com