RECOM RP10

Features
●
●
●
●
●
●
●
4:1 Wide Input Voltage Range
10 Watts Output Power
1.6kVDC Isolation
Fixed Operating Frequency
Six-Sided Continuous Shield
Standard 50.8 x25.4x10.2mm Package
Efficiency to 84%
POWERLINE
DC/DC-Converter
RP10S_DEW
Series
10 Watt
2” x 1” Package
Single & Dual
Output
Selection Guide 24V and 48V Input Types
Part Number
Input
Range
VDC
Output
Voltage
VDC
Output
Current
mA
Input (4)
Current
mA
Efficiency(5) Capacitive(6)
Load max.
%
µF
RP10-2405SEW
9-36
5
2000
548
80
4700
RP10-2412SEW
9-36
12
830
532
82
690
RP10-2415SEW
9-36
15
670
551
80
470
RP10-4805SEW
18-75
5
2000
274
80
4700
RP10-4812SEW
18-75
12
830
259
84
690
RP10-4815SEW
18-75
15
670
262
84
470
RP10-2405DEW
9-36
±5
±1000
548
80
±680
RP10-2412DEW
9-36
±12
±416
547
80
±330
RP10-2415DEW
9-36
±15
±333
548
80
±110
RP10-4805DEW
18-75
±5
±1000
271
81
±680
RP10-4812DEW
18-75
±12
±416
281
78
±330
RP10-4815DEW
18-75
±15
±333
270
81
±110
* add suffix /M
M2 for higher efficiencies and extended temperature range.
* add /PP for CTRL function with Positive Logic (1=ON, 0=OFF)
N for CTRL function with Negative Logic (0=ON, 1=OFF)
* add /N
224
July-2006
www.recom-international.com
RP10-S_DEW
Series
POWERLINE
DC/DC-Converter
Derating-Graph (Ambient Temperature)
RP10-2405SEW With Heat Sink
RP10-2405SEW
125
125
100
100
75
Natural Convection
Output Power (%)
Output Power (%)
75
50
25
0
-25
-10 0
50 60 70 80 90 100
Ambient Temperature Range (°C)
-10 0
50 60 70 80 90 100
Ambient Temperature Range (°C) 75
100
100
75
75
50
Natural Convection
25
0
-25
-10 0
50 60 70 80 90 100
Ambient Temperature Range (°C) 74
RP10-2405SEW/M2
50 60 70
Ambient Temperature Range (°C)
Output Power (%)
80 90 100
-10 0
50 60 70
80 90 100
78
RP10-2405SEW/M2 With Heat Sink
50
Natural Convection
25
0
-40 -25 -10 0
50 60 70 80 90 100
Ambient Temperature Range (°C) 75
RP10-2405DEW/M2
125
100
RP10-2405DEW/M2 With Heat Sink
100
75
Natural Convection
Output Power (%)
50
0
-25
75
Natural Convection
0
-40 -25 -10 0
75
Natural Convection
25
100
25
125
50
125
75
50
RP10-2405DEW With Heat Sink
Ambient Temperature Range (°C)
100
Output Power (%)
0
-25
125
125
Output Power (%)
25
125
Output Power (%)
Output Power (%)
RP10-2405DEW
Natural Convection
50
25
0
-40 -25 -10 0
50 60 70 80 90 100
Ambient Temperature Range (°C) 74
50
Natural Convection
25
0
-40 -25 -10 0
50 60 70
Ambient Temperature Range (°C)
80 90 100
78
Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a
part-number not shown here please contact our technical customer service at [email protected]
www.recom-international.com
July-2006
225
RP10-S_DEW
Series
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
24V nominal input
48V nominal input
Input Filter
Input Surge Voltage (100 ms max.)
9-36VDC
18-75VDC
Pi Type
24V Input
48V Input
50VDC
100VDC
Input Reflected Ripple (nominal Vin and full load)
30mAp-p
Start Up Time (nominal Vin and constant resistor load)
20ms typ.
Remote ON/OFF (Optional. See Note 7)
(Positive logic)
(Negative logic)
Remote OFF input current
DC-DC ON
Open or 3.5V < Vr < 12V
DC-DC OFF
Short or 0V < Vr < 1.2V
DC-DC ON
Short or 0V < Vr < 1.2V
DC-DC OFF
Open or 3.5V < Vr < 12V
Nominal input
Output Power
10W max.
Output Voltage Accuracy (full Load and nominal Vin)
±2%
Minimum Load (see Note 1)
10% of full load
Line Regulation (low line, high line at full load)
Load Regulation (25% to 100% full load)
±1%
Single
Dual
Cross Regulation (asymmetrical load 25%/100% full load)
Ripple and Noise (20MHz bandwith)
±1%
±2%
±5%
Single
50mVp-p
Dual
75mVp-p
Temperature Coefficient
±0.02%/°C max.
Transient Response (25% load step change)
Over Voltage Protection
Zener diode clamp
20mA
500µs
5V output
12V output
15V output
Over Load Protection (% of full load at nominal Vin)
6.2V
15V
18V
150% typ
Short Circuit Protection
Hiccup, automatic recovery
Efficiency
see „Selection Guide“ table
Isolation Voltage
1600VDC min.
Isolation Resistance
1 GΩ min.
Isolation Capacitance
300pF max.
Operating Frequency
300kHz typ.
Operating Temperature Range
Standard
-25°C to +85°C(with derating)
(Reference Derating Curve) (see Note 9)
M2
-40°C to +85°C(with derating)
Maximum Case Temperature
+100°C
Storage Temperature Range
-55°C to +105°C
Thermal Impedance
Natural convection
12°C/Watt
(see Note 8)
Natural convection with Heat Sink
10°C/Watt
Thermal Shock
MIL-STD-810D
continued on next page
226
July-2006
www.recom-international.com
RP10-S_DEW
Series
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25°C unless otherwise noted)
Vibration
10-55Hz, 2G, 30 Min. along X, Y and Z
Relative Humidity
5% to 95% RH
Case Material
Nickel plated copper
Base Material
Non-conductive black plastic
Potting Material
Conducted Emissions (see Note 10)
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Epoxy (UL94-V0)
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Weight
Level A
Level A
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
27g
Dimensions
50.8 x 25.4 x 10.2mm
1976 x 103 hours
MTBF (see Note 2)
Notes :
1. The RP10 (W) series required a minimum 10% loading on the output to maintain specified regulation.
Operation under no-load condition will not damage these devices, however they may not meet all listedspecification.
2. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment).
3. Simulated source impedance of 12µH. 12µH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input.
Positive logic ON/OFF is marked with suffix-P (eg. RP10-2405SEW/P)
Negative logic ON/OFF is marked with suffix-N (eg. RP10-2405SEW/N).
If no suffix is specified, the control pin will be omitted.
8. Heat sink is optional and P/N: 7G-0020A.
9. M2 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard version.
10. See application notes for EMI-filtering.
www.recom-international.com
July-2006
227
RP10-S_DEW
Series
POWERLINE
DC/DC-Converter
Package Style and Pinning (mm)
3rd angle
projection
50.80
25.40
10.20
dia.
1.0
5.6
2.50
5.10
20.30
15.20
Pin Connections
3
1
2
6
Bottom View
10.20
4
10.20
5
12.70
Pin #
Single
1
+Vin
2
-Vin
3
+Vout
4
No Pin
5
-Vout
6*
CTRL*
* Optional. See Note 7
Dual
+Vin
-Vin
+Vout
Com
-Vout
CTRL*
Pin Pitch Tolerance ±0.35 mm
228
July-2006