Tfs144.doc version 3.1 VI TELEFILTER 16.11.2001 Filter Specification TFS 144 1/5 Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc:*) 23 °C 0 dBm input: output: 1,30 kΩ|| -12,9 pF 1,21 kΩ|| -12,1 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 144 is the minimum of the pass band attenuation amin. It is defined as the insertion loss ae. The centre frequence fc is the arithmetic mean value of the upper and lower frequencies at the 1,5 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 144 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (Reference level) Nominal frequency fN Centre frequency fc ae 1,5 dB Passband 12,5 tolerance / limit dB max. 144,15 2,6 dB 144,15 MHz MHz MHz MHz min. 2,2 max. min. min. 1,5 40,0 35,0 Relative attenuation arel 1,1 MHz fN ... fN ± 2,0 MHz ... fN ± 10,0 MHz fN ± 10,0 MHz ... fN ± 100 MHz fN ± 1,0 43 60 dB dB dB VSWR: 13 dB Operating temperature range Temperature coefficient of frequency ( Tcf ) **) Frequency inversion temperature To -0,036 ppm/ K² 25 °C Input power level: 15,0 dB dB dB 0 °C ... + 70 °C max. 10,0 dBm *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆fc(Hz) = Tcf(ppm/K²) x (To - TA) ² x fTo (MHz) fTo is reference frequence fc at frequency inversion temperature (To) Generated: Checked/Approved: VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Tfs144.doc version 3.1 VI TELEFILTER 16.11.2001 Filter Specification TFS 144 2/5 Construction and pin connection (All dimensions in mm) 13.3 Max TFS 144 1 2 3 4 5 6 7 8 9 10 11 12 6.5 Max N44 Datecode Ground Ground Ground Ground Output Output RF Return Ground Ground Ground Ground Input Input RF Return Date code: L M N ...... L1 L2 11 Input 50 Ohm Year+week 1999 2000 2001 5 Output SAW C1 C2 50 Ohm 6 12 1,2,3,4,7 8,9,10 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Tfs144.doc version 3.1 VI TELEFILTER 16.11.2001 Filter Specification TFS 144 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min each. / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer Tape (all dimensions in mm) W : 24 ± 0,3 Po : 4 ± 0,1 Do E : : 1,5 + 0,1 1,75 ± 0,1 F : 11,5 ± 0,1 G (min) : P2 : P1 : D1(min) : 0,60 2 ± 0,1 12 ± 0,1 1,5 Ao : 7,1 ± 0,2 Bo : 13,9 ± 0,2 CT : 21,5 ± 0,1 1700 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Do Po P2 E Ao F D1 CT W Bo G P1 COVER TAPE W2 Reel (all dimensions in mm): A : W1 : W2 (max) : 330 24,40 +2,0 30,4 N (min) : 60 C : 13 + 0,5/-0.2 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the left side of the tape. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Tfs144.doc version 3.1 VI TELEFILTER 16.11.2001 Filter Specification TFS 144 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information Tfs144.doc version 3.1 VI TELEFILTER Filter Specification 16.11.2001 TFS 144 5/5 History Version Reason of Changes Name Date Steiner 13.07.2000 Steiner 27.04.2001 filter specification 3.0 - terminating impedance and typical values for final samples added Steiner 07.11.2001 3.1 Steiner 16.11.2001 Development specification 1.0 - generation of specification preliminary filter specification 2.0 - passband ripple relaxed to 1,5dB - VSWR limit exchanged with a typical value - terminating impedance slightly corrected on final samples VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information