1. Measurement condition :
Ambient temperature TA:
Input power level:
Terminating impedances in fc * ) :
for input:
for output:
External coil:
23
0
°C.
dBm.
2,9 kOhm
2,9 kOhm
820 nH
-3,8 pF
-3,8 pF
2. Characteristics :
Remark: Reference level for the relative attenuation arel of the TFS70Y is the minimum of the pass band attenuation amin. The minimum of the
pass band attenuation amin is defined as the insertion loss a e. The reference frequency fc is the arithmetic mean value of the upper and lower
frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the
reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating
temperature range is not included in the production tolerance scheme.
Data
typ. value
Insertion Loss
(Reference Level)
ae
3,7
fc
dB
70,002 MHz
Variation / Limitation
max
6,0
70,0 ±
Centre frequency
(at ambient temperature TA)
Relative Attenuation
fN - 35
kHz ... fN + 35
fN ± 35
kHz ... fN ± 47
arel
kHz
kHz
fN
fN
fN
fN
kHz
kHz
kHz
MHz
2,5
10
45
43
Tcf 2nd order **)
- 0,043 ppm/K
-
25
-
±
±
±
±
60
90
450
500
kHz
kHz
kHz
kHz
... fN ± 90
... fN ± 450
... fN ± 500
... fN ± 10
Temperature Coefficient
Turn over temperature
0,5 dB
2
dB
T0
°C
-
Operating Temperature Range
Storage Temperature Range
dB
dB
dB
dB
-
dB
0,015 MHz
max.
max.
1
3
dB
dB
min.
min.
min.
min.
1
3
35
40
dB
dB
dB
dB
- 5 °C ... + 70 °C
- 30 °C ... + 90 °C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
**) fc(Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz)
generated:
checked / approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs70y.doc
Version 3.0
VI TELEFILTER
06.06.2003
Filter Specification
TFS 70 Y
2/5
3. Construction and Pin Configuration
(All Dimensions in mm)
13,31 ±0,20
10
1
6
Date Code
1
2
3
4
5
6
7
8
9
10
5
1,0±0,2
Input RF-Return
Ground
Ground
Ground
Output
External Coil
Ground
Ground
Ground
Input
Datecode
Year+week
N
P
R
...
2001
2002
2003
1,91±0,2
7,62±0,2
4. 50
Matching Network
L1
10
C1
L2
5
SAW
C2
6
1, 2, 3, 4, 7, 8, 9
L3
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs70y.doc
Version 3.0
VI TELEFILTER
06.06.2003
Filter Specification
TFS 70 Y
3/5
5. Stability characteristics :
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
6. Packing
Tape & Reel:
DIN IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
1700
min 300 mm
min 500 mm
min 300
mm
EMBOSSED CARRIER TAPE
Tape (all dimensions in mm)
Do
W
Po
Do
E
F
G (min)
P2
P1
D1(min)
Ao
Bo
CT
:
:
:
:
:
:
:
:
:
:
:
:
24
4
1,5
1,75
11,5
0,6
2
12
1,5
7,1
13,9
21,5
Po
P
2
+ 0,3/ -0,1
± 0,1
+ 0,1
± 0,1
± 0,1
E
A
F
D
± 0,1
± 0,1
o
CT
B
± 0,1
± 0,
± 0,1
1
W
o
G
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
:
W2 (max) :
330
24,4 +2
30,4
N (min)
:
60
C
:
13 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs70y.doc
Version 3.0
VI TELEFILTER
06.06.2003
Filter Specification
TFS 70 Y
4/5
7. Air reflow temperature conditions
st
1 and 2
nd
air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C – 170 °C
60 sec. – 90 sec.
main-heating periods
over 200 °C
20 sec. – 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. Time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
Temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
Temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs70y.doc
Version 3.0
VI TELEFILTER
Filter Specification
06.06.2003
TFS 70 Y
5/5
8. History
Version
Reason of Changes
Name
Date
1.0
-
Generate development specification
Steiner
30.07.2002
1.1
-
Change package to 15*6,5 mm.
Add second package option (11*5 mm)
Change pass band width.
Correct typo for stop band definition.
Remove group delay limits.
Introduce centre frequency limits.
Change remark for characteristic.
Dr. Wall
20.12.2002
2.0
-
Change from development specification to preliminary specification.
Remove package version 1.
Change 1 dB bandwidth from ± 40 kHz to ± 35 kHz minimum.
Change 3 dB bandwidth from ± 60 kHz to ± 47 kHz minimum.
Change insertion loss from 10 dB to 6 dB maximum.
Add typical values.
Add termination impedances.
Add packing information.
Dr. Wall
13.05.2003
3.0
-
Change from preliminary specification to filter specification.
Change from 11*5 to 13*6,5 mm package.
Change pinning.
Change packing information.
Change termination impedances.
Add typical values.
Dr. Wall
06.06.2003
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.