VECTRON TFS1842

Tfs1842.doc
version 1.5
VI TELEFILTER
30.10.2003
Preliminary Specification
TFS 1842
1/5
Measurement condition
23 C
13 dBm
Ambient temperature:
Input power level:
Terminating impedances
for input:
for output:
50 Ohm
50 Ohm
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss. The nominal frequency fN is fixed at 1842,5 MHz without any tolerance or limit.
The values of absolute attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss
PB
-
Nominal frequency
within
fN
-
Centre frequency
fC
1842,5
tolerance/limit
max.
MHz
Pass band
PB
-
fN
PB
-
max.
Absolute attenuation
aabs
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
...
...
...
...
...
...
...
...
...
...
...
...
...
VSWR
370
1300
1705
1785
1980
2530
2680
3400
3975
4200
4920
5200
6000
within
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
-
dB
MHz
-
Pass-band ripple within
10
370
1300
1705
1920
1980
2530
2680
3400
3975
4200
4920
5200
3,9
1842,5
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
min.
37,5
1,9
40
37
30
10
10
23
31
28
24
23
10
7
5
MHz
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
PB
input
2,3 : 1
output
2,5 : 1
Operating temperature range
-
- 20 °C ... + 80 °C
Storage temperature range
-
- 40 °C ... + 85 °C
Temperature coefficient of frequency
Input power level
TCf
t.b.d.
-
max.
15
dBm
generated:
checked / approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs1842.doc
version 1.5
VI TELEFILTER
30.10.2003
Preliminary Specification
TFS 1842
2/5
Construction and pin configuration
(All dimensions in mm)
5
6
4
L42
R39
Date code: Year+week
date code
2
1
0,1
1
0,6
6
3
3
N
P
R
Pin
Pin
Pin
Pin
Pin
Pin
2001
2002
2003
...
1
2
3
4
5
6
Ground
Input
Ground
Ground
Output
Ground
4
0,6
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs1842.doc
version 1.5
VI TELEFILTER
30.10.2003
Preliminary Specification
TFS 1842
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page
4
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
9000
min 300 mm
min 500 mm
min 300 mm
EMBOSSED CARRIER TAPE
Tape (all dimensions in mm)
W
Po
Do
E
F
G (min)
P2
P1
D1(min)
:
:
:
:
:
:
:
:
:
8
4
1,5
1,75
3,5 ±
0,75
2
4
1,5
± 0,3
± 0,1
+ 0,1
± 0,1
0,05
Ao
Bo
CT
:
:
:
3,25
3,25
5,5
± 0,1
± 0,1
± 0,2
Do
Po
P2
E
Ao
F
D1
CT
W
Bo
± 0,05
± 0,1
G
P1
COVER TAPE
W2
Reel (all dimensions in mm):
A
W1
:
330
:
8,4 + 2,0
W2 (m ax) :
14,4
N (m in)
:
C
:
50
13
A
+0,5/ -0,2
C
N
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs1842.doc
version 1.5
VI TELEFILTER
30.10.2003
Preliminary Specification
TFS 1842
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
peak temperature
over 200 °C
255 °C ± 5 °C
20 sec. - 25 sec.
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / s ec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs1842.doc
version 1.5
VI TELEFILTER
Preliminary Specification
30.10.2003
TFS 1842
5/5
History
Version
Reason of Change
Name
Date
1.0
generation of “Development specification” according to customer requirements
Steiner
24.07.2003
1.1
generate preliminary specification.
change rejections 4200.0 ... 4920.0 MHz : from 15 dB to 10 dB
4920.0 ... 5200.0 MHz : from 10 dB to 7 dB
Konietzko
16.09.2003
1.2
package corrected
Pfeiffer
24.09.2003
1.3
change pass band
change relative attenuation to absolute attenuation
Roizengaft
14.10.2003
1.4
typical values for VSWR added
Steiner
22.10.2003
1.5
definition of packing
Roizengaft
30.10.2003
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.