Tfs1842.doc version 1.5 VI TELEFILTER 30.10.2003 Preliminary Specification TFS 1842 1/5 Measurement condition 23 C 13 dBm Ambient temperature: Input power level: Terminating impedances for input: for output: 50 Ohm 50 Ohm Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss. The nominal frequency fN is fixed at 1842,5 MHz without any tolerance or limit. The values of absolute attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss PB - Nominal frequency within fN - Centre frequency fC 1842,5 tolerance/limit max. MHz Pass band PB - fN PB - max. Absolute attenuation aabs MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz ... ... ... ... ... ... ... ... ... ... ... ... ... VSWR 370 1300 1705 1785 1980 2530 2680 3400 3975 4200 4920 5200 6000 within MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz - dB MHz - Pass-band ripple within 10 370 1300 1705 1920 1980 2530 2680 3400 3975 4200 4920 5200 3,9 1842,5 min. min. min. min. min. min. min. min. min. min. min. min. min. 37,5 1,9 40 37 30 10 10 23 31 28 24 23 10 7 5 MHz dB dB dB dB dB dB dB dB dB dB dB dB dB dB PB input 2,3 : 1 output 2,5 : 1 Operating temperature range - - 20 °C ... + 80 °C Storage temperature range - - 40 °C ... + 85 °C Temperature coefficient of frequency Input power level TCf t.b.d. - max. 15 dBm generated: checked / approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs1842.doc version 1.5 VI TELEFILTER 30.10.2003 Preliminary Specification TFS 1842 2/5 Construction and pin configuration (All dimensions in mm) 5 6 4 L42 R39 Date code: Year+week date code 2 1 0,1 1 0,6 6 3 3 N P R Pin Pin Pin Pin Pin Pin 2001 2002 2003 ... 1 2 3 4 5 6 Ground Input Ground Ground Output Ground 4 0,6 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs1842.doc version 1.5 VI TELEFILTER 30.10.2003 Preliminary Specification TFS 1842 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4 Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 9000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Tape (all dimensions in mm) W Po Do E F G (min) P2 P1 D1(min) : : : : : : : : : 8 4 1,5 1,75 3,5 ± 0,75 2 4 1,5 ± 0,3 ± 0,1 + 0,1 ± 0,1 0,05 Ao Bo CT : : : 3,25 3,25 5,5 ± 0,1 ± 0,1 ± 0,2 Do Po P2 E Ao F D1 CT W Bo ± 0,05 ± 0,1 G P1 COVER TAPE W2 Reel (all dimensions in mm): A W1 : 330 : 8,4 + 2,0 W2 (m ax) : 14,4 N (m in) : C : 50 13 A +0,5/ -0,2 C N W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs1842.doc version 1.5 VI TELEFILTER 30.10.2003 Preliminary Specification TFS 1842 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods peak temperature over 200 °C 255 °C ± 5 °C 20 sec. - 25 sec. Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / s ec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs1842.doc version 1.5 VI TELEFILTER Preliminary Specification 30.10.2003 TFS 1842 5/5 History Version Reason of Change Name Date 1.0 generation of “Development specification” according to customer requirements Steiner 24.07.2003 1.1 generate preliminary specification. change rejections 4200.0 ... 4920.0 MHz : from 15 dB to 10 dB 4920.0 ... 5200.0 MHz : from 10 dB to 7 dB Konietzko 16.09.2003 1.2 package corrected Pfeiffer 24.09.2003 1.3 change pass band change relative attenuation to absolute attenuation Roizengaft 14.10.2003 1.4 typical values for VSWR added Steiner 22.10.2003 1.5 definition of packing Roizengaft 30.10.2003 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.