SMMS702B − JANUARY 1998 − REVISED APRIL 1998 D Organization: D D D D D D D D D JEDEC 168-Pin Dual-In-Line Memory − TM2TR64EPH . . . 2 097 152 x 64 Bits − TM4TR64EPH . . . 4 194 304 x 64 Bits − TM2TR72EPH . . . 2 097 152 x 72 Bits − TM4TR72EPH . . . 4 194 304 x 72 Bits Single 3.3-V Power Supply (±10% Tolerance) Designed for 100-MHz 4-Clock Systems TM2TR64EPH — Uses Eight 16M-Bit Synchronous Dynamic RAMs (SDRAMs) (2M × 8-Bit) in Plastic Thin Small-Outline Packages (TSOPs) TM4TR64EPH — Uses Sixteen 16M-Bit SDRAMs (2M × 8-Bit) in Plastic TSOPs TM2TR72EPH — Uses Nine 16M-Bit SDRAMs (2M × 8-Bit) in Plastic TSOPs TM4TR72EPH — Uses Eighteen 16M-Bit SDRAMs (2M × 8-Bit) in Plastic TSOPs Byte-Read/Write Capability Performance Ranges: SYNCHRONOUS CLOCK CYCLE TIME tCK3 tCK2 (CL = 3)† (CL = 2) ACCESS TIME CLOCK TO OUTPUT tAC3 tAC2 (CL = 3) (CL = 2) D D D D D D D D D Module (DIMM) Without Buffer for Use With Socket High-Speed, Low-Noise, Low-Voltage TTL (LVTTL) Interface Read Latencies 2 and 3 Supported Support Burst-Interleave and Burst-Interrupt Operations Burst Length Programmable to 1, 2, 4, and 8 Two Banks for On-Chip Interleaving (Gapless Access) Ambient Temperature Range 0°C to 70°C Gold-Plated Contacts Pipeline Architecture Serial Presence Detect (SPD) Using EEPROM REFRESH INTERVAL ’xTRxxEPH-8 8 ns 10 ns 6 ns 6 ns 64 ms ’xTRxxEPH-8A 8 ns 15 ns 6 ns 7.5 ns 64 ms † CL = CAS latency description The TM2TR64EPH is a 16M-byte, 168-pin DIMM. The DIMM is composed of eight TMS626812BDGE 2097 152 x 8-bit SDRAMs, each in a 400-mil, 44-pin plastic TSOP mounted on a substrate with decoupling capacitors. See the TMS626812B data sheet (literature number SMOS693). The TM4TR64EPH is a 32M-byte, 168-pin DIMM. The DIMM is composed of sixteen TMS626812BDGE 2 097 152 x 8-bit SDRAMs, each in a 400-mil, 44-pin plastic TSOP mounted on a substrate with decoupling capacitors. The TM2TR72EPH is an 16M-byte, 168-pin DIMM. The DIMM is composed of nine TMS626812BDGE 2 097 152 x 8-bit SDRAMs, each in a 400-mil, 44-pin plastic TSOP mounted on a substrate with decoupling capacitors. The TM4TR72EPH is a 32M-byte, 168-pin DIMM. The DIMM is composed of eighteen TMS626812BDGE 2 097 152 x 8-bit SDRAMs, each in a 400-mil, 44-pin plastic TSOP mounted on a substrate with decoupling capacitors. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Copyright 1998, Texas Instruments Incorporated !" #!$% &"' &! #" #" (" " ") !" && *+' &! #", &" ""%+ %!&" ", %% #""' POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 1 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 operation The TM2TR64EPH operates as eight TMS626812BDGE devices that are connected as shown in the TM2TR64EPH functional block diagram. The TM4TR64EPH operates as sixteen TMS626812BDGE devices connected as shown in the TM4TR64EPH functional block diagram. The TM2TR72EPH operates as nine TMS626812BDGE devices that are connected as shown in the TM2TR72EPH functional block diagram. The TM4TR72EPH operates as eighteen TMS626812BDGE devices connected as shown in the TM4TR72EPH functional block diagram. 2 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 DUAL-IN-LINE MEMORY MODULE ( TOP VIEW ) TM2TR64EPH TM4TR64EPH ( SIDE VIEW ) ( SIDE VIEW ) PIN NOMENCLATURE A[0:10] A[0:8] A11/BA0 CAS CB[0:7] CKE[0:1] CK[0:3] DQ[0:63] DQMB[0:7] 1 10 NC RAS S[0:3] SA[0:2] 11 SCL SDA VDD VSS WE WP Row-Address Inputs Column-Address Inputs Bank-Select Zero Column-Address Strobe Check Bit In/Check Bit Out Clock Enable System Clock Data-In / Data-Out Data-In/Data-Out Mask Enable No Connect Row-Address Strobe Chip-Select Serial Presence Detect (SPD) Device Address Input SPD Clock SPD Address / Data 3.3-V Supply Ground Write Enable SPD Write-Protect 40 41 84 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 3 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 Pin Assignments PIN NO. NAME NO. 1 43 2 VSS DQ0 3 DQ1 4 NO. 85 44 VSS NC 45 S2 DQ2 46 5 DQ3 6 7 VDD DQ4 8 DQ5 9 PIN NAME NO. PIN NAME 127 86 VSS DQ32 87 DQ33 129 S3 DQMB2 88 DQ34 130 DQMB6 47 DQMB3 89 DQ35 131 DQMB7 48 NC 90 132 NC 49 91 133 50 VDD NC VDD DQ36 92 DQ37 134 VDD NC DQ6 51 NC 93 DQ38 135 NC 10 DQ7 52 CB2 94 DQ39 136 CB6 11 DQ8 53 CB3 95 DQ40 137 CB7 12 VSS DQ9 54 97 VSS DQ41 138 55 VSS DQ16 96 13 139 VSS DQ48 14 DQ10 56 DQ17 98 DQ42 140 DQ49 15 DQ11 57 DQ18 99 DQ43 141 DQ50 16 DQ12 58 DQ19 100 DQ44 142 DQ51 17 DQ13 59 101 DQ45 143 18 60 102 144 61 NC 103 VDD DQ46 VDD DQ52 19 VDD DQ14 VDD DQ20 145 NC 20 DQ15 62 NC 104 DQ47 146 NC 21 CB0 63 CKE1 105 CB4 147 NC 22 CB1 64 106 CB5 148 23 VSS NC 65 VSS DQ21 107 149 66 DQ22 108 VSS NC VSS DQ53 150 DQ54 25 NC 67 DQ23 109 NC 151 DQ55 26 68 111 VDD CAS 152 69 VSS DQ24 110 27 VDD WE 153 VSS DQ56 28 DQMB0 70 DQ25 112 DQMB4 154 DQ57 29 DQMB1 71 DQ26 113 DQMB5 155 DQ58 30 S0 72 DQ27 114 S1 156 DQ59 31 NC 73 115 RAS 157 32 74 116 VDD DQ60 75 DQ29 117 VSS A1 158 33 VSS A0 VDD DQ28 159 DQ61 34 A2 76 DQ30 118 A3 160 DQ62 35 A4 77 DQ31 119 A5 161 DQ63 36 A6 78 A7 162 A8 79 VSS CK2 120 37 121 A9 163 VSS CK3 38 A10 80 NC 122 A11/BA0 164 NC 39 NC 81 WP 123 NC 165 SA0 40 82 SDA 124 SA1 83 SCL 125 VDD CK1 166 41 VDD VDD 167 SA2 42 CK0 84 VDD 126 NC 168 VDD 24 4 PIN NAME POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 128 VSS CKE0 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 dual-in-line memory module and components The dual-in-line memory module and components include: D PC substrate: 1,27 ± 0,1 mm (0.05 inch) nominal thickness; 0.005 inch/inch maximum warpage D Bypass capacitors: Multilayer ceramic D Contact area: Nickel plate and gold plate over copper TM2TR64EPH functional block diagram S0 RC CS CK: U0, U4 CS CK0† RC CK: U1, U5 U0 DQMB0 DQM R DQ[0:7] 8 U4 DQMB4 DQ[32:39] 8 CK: U2, U6 CK2† DQM R DQ[0:7] RC RC CK: U3, U7 DQ[0:7] RC CK1 CS C CS RC CK3 U1 DQMB1 DQM R DQ[8:15] 8 U5 DQMB5 R DQ[0:7] C DQM DQ[40:47] 8 DQ[0:7] R = 10 Ω RC = 10 Ω C = 10 pF S2 DQMB2 DQM R 8 Two 0.1 µF per SDRAM device CS U2 DQ[16:23] U[0:7] VDD CS DQMB6 U[0:7] DQM R DQ[0:7] VSS U6 DQ[48:55] 8 DQ[0:7] SPD EEPROM CS CS U3 DQMB3 DQ[24:31] RAS CAS WE CKE0 A[0:11] DQM R 8 U7 DQMB7 47 kΩ DQM R DQ[0:7] DQ[56:63] RAS: SDRAM U[0:7] CAS: SDRAM U[0:7] WE: SDRAM U[0:7] CKE: SDRAM U[0:7] A[0:11]: SDRAM U[0:7] 8 SDA SCL WP A0 A1 A2 SA0 SA1 SA2 DQ[0:7] LEGEND: CS = SPD = Chip select Serial Presence Detect † Additional 3.3 pF capacity is used to balance loads among clocks. POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 5 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 TM4TR64EPH functional block diagram S1 VDD S0 CS CS CS U[0:7], UB[0:7] Two 0.1 µF per SDRAM device CS VSS U0 DQMB0 DQM R DQ[0:7] 8 R DQ[8:15] 8 DQM U4 DQMB4 R DQ[0:7] DQ[0:7] CS CS U1 DQMB1 UB0 8 DQ[32:39] UB1 DQM DQM DQ[0:7] DQ[0:7] DQM DQM DQ[0:7] DQ[0:7] CS CS U5 DQMB5 R 8 DQ[40:47] U[0:7], UB[0:7] UB4 UB5 DQM DQM DQ[0:7] DQ[0:7] VDD 10 kΩ CKE1 CKE: UB[0:7] CKE0 CKE: U[0:7] RAS RAS: U[0:7], UB[0:7] CAS CAS: U[0:7], UB[0:7] WE WE: U[0:7], UB[0:7] A[0:11] A[0:11]: U[0:7], UB[0:7] R = 10 Ω RC = 10 Ω S3 RC S2 CK0† CS U2 DQMB2 R DQ[16:23] 8 CS CS UB2 DQM DQM DQ[0:7] DQ[0:7] CS CS U6 DQMB6 R 8 DQ[48:55] CK: U1, U5 CS UB6 DQM DQM DQ[0:7] DQ[0:7] CS CS CK: U0, U4 RC RC CK1† CK: UB0, UB4 RC CK: UB1, UB5 RC CK2† CK: U2, U6 RC CK: U3, U7 RC CK3† CK: UB2, UB6 RC CK: UB3, UB7 U3 DQMB3 DQM R DQ[24:31] LEGEND: CS = SPD = 8 DQ[0:7] U7 UB3 DQM DQ[0:7] DQMB7 R 8 DQ[56:63] UB7 DQM DQM DQ[0:7] DQ[0:7] Chip select Serial Presence Detect SCL WP 47 kΩ † Additional 3.3 pF capacity is used to balance loads among clocks. 6 SPD EEPROM POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 SDA A0 A1 A2 SA0 SA1 SA2 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 TM2TR72EPH functional block diagram S0 RB CS DQMB0 U0 DQM R DQ[0:7] 8 U0, U4 CS DQMB4 DQ[32:39] 8 CS U1, U5, U8 U4 DQM R DQ[0:7] RB CK0 RC U2, U6 DQ[0:7] RC CK2† U3, U7 RC CS CK1 DQMB1 U1 DQM R DQ[8:15] 8 DQMB5 R DQ[0:7] U5 DQM DQ[40:47] 8 C DQ[0:7] RC CK3 CS DQMB1 U8 DQM R CB[0:7] 8 DQ[0:7] S2 VDD CS DQMB2 DQ[16:23] 8 U2 DQMB6 DQ[0:7] DQ[48:55] 8 8 U3 DQMB7 DQ[0:7] DQ[56:63] RAS: SDRAM U[0:8] CAS CAS: SDRAM U[0:8] WE WE: SDRAM U[0:8] A[0:11] U[0:8] CKE: SDRAM U[0:8] A[0:11]: SDRAM U[0:8] U7 DQM R RAS CKE0 VSS DQ[0:7] CS DQM R U6 DQM R CS DQMB3 U[0:8] Two 0.1 µF per SDRAM device CS DQM R DQ[24:31] C R = 10 Ω RB = 5 Ω RC = 10 Ω C = 10 pF 8 DQ[0:7] SPD EEPROM SCL WP 47 kΩ LEGEND: CS = Chip Select SPD = Serial Presence Detect SDA A0 A1 A2 SA0 SA1 SA2 † Additional 3.3 pF capacity is used to balance loads among clocks. POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 7 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 TM4TR72EPH functional block diagram S1 VDD S0 CS CS CS U[0:8], UB[0:8] Two 0.1 µF per SDRAM device CS VSS U0 DQMB0 DQM R DQ[0:7] 8 DQ[0:7] U1 R DQ[8:15] 8 U4 DQMB4 DQM R CS DQMB1 UB0 DQ[0:7] DQ[32:39] 8 CS DQM DQM DQ[0:7] DQ[0:7] CS UB1 DQM DQM DQ[0:7] DQ[0:7] U5 DQMB5 R DQ[40:47] 8 U[0:8], UB[0:8] UB4 R = 10 Ω RC = 10 Ω RB = 5 Ω CS RB UB5 DQM DQM DQ[0:7] DQ[0:7] CK: U0, U4 RB CK0 CK: U1, U5, U8 RB CK: UB0, UB4 RB CK1 CS CK: UB1, UB5, UB8 CS RC U8 DQMB1 UB8 DQM R CB[0:7] 8 CK2† DQM DQ[0:7] CK: U2, U6 RC CK: U3, U7 RC DQ[0:7] CK3† CK: UB2, UB6 RC CK: UB3, UB7 S3 VDD S2 CS U2 DQMB2 R DQ[16:23] 8 CS CS UB2 DQM DQM DQ[0:7] DQ[0:7] U6 DQMB6 R CS DQ[48:55] 8 UB6 DQM DQM DQ[0:7] DQ[0:7] CS CS 10 kΩ CS CKE1 CKE: UB[0:8] CKE0 CKE: U[0:8] RAS RAS: U[0:8], UB[0:8] CAS CAS: U[0:8], UB[0:8] WE WE: U[0:8], UB[0:8] CS A[0:11] U3 DQMB3 DQM R DQ[24:31] LEGEND: CS = SPD = 8 DQ[0:7] U7 UB3 DQMB7 DQM R DQ[0:7] DQ[56:63] 8 DQM DQM DQ[0:7] DQ[0:7] 47 kΩ † Additional 3.3 pF capacity is used to balance loads among clocks. 8 POST OFFICE BOX 1443 SPD EEPROM SCL WP Chip select Serial Presence Detect • HOUSTON, TEXAS 77251−1443 A[0:11]: U[0:8], UB[0:8] UB7 SDA A0 A1 A2 SA0 SA1 SA2 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 absolute maximum ratings over operating ambient temperature range (unless otherwise noted)† Supply voltage range, VDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 4.6 V Voltage range on any pin (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . − 0.5 V to 4.6 V Short-circuit output current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA Power dissipation: TM2TR64EPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 W TM4TR64EPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 W TM2TR72EPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 W TM4TR72EPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 W Operating ambient temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . − 55°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: All voltage values are with respect to VSS. recommended operating conditions‡ VDD VSS Supply voltage VIH VIH-SPD High-level input voltage MIN NOM MAX UNIT 3 3.3 3.6 V Supply voltage 0 2 High-level input voltage for the SPD device 0.7*VDD −0.3 VIL Low-level input voltage TA Operating ambient temperature ‡ The overshoot and undershoot voltage duration is less than or equal to 3 ns with no input clamp diode. V VDD + 0.3 VDD + 0.5 0 V V 0.8 V 70 °C capacitance over recommended ranges of supply voltage and ambient temperature, f = 1 MHz (see Note 2)§ TMxTRxxEPH PARAMETER MIN MAX UNIT Ci(CK) Input capacitance, CK input 2.5 4 pF Ci(AC) Input capacitance, address and control inputs: A0 −A11, RAS, CAS, WE 2.5 5 pF Ci(CKE) Input capacitance, CKE input 5 pF Co Output capacitance 4 6.5 pF Ci(DQMBx) Input capacitance, DQMBx input 2.5 5 pF Ci(Sx) Input capacitance, Sx input 2.5 5 pF Ci/o(SDA) Input/output capacitance, SDA input 9 pF 7 pF Ci(SPD) Input capacitance, SA0, SA1, SA2, SCL inputs § Specifications in this table represent a single SDRAM device. NOTE 2: VDD = 3.3 V ± 0.3 V. Bias on pins under test is 0 V. POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 9 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 electrical characteristics over recommended ranges of supply voltage and operating ambient temperature (unless otherwise noted) (see Note 3)† ’xTRxxEPH-8 PARAMETER VOH VOL High-level output voltage Low-level output voltage TEST CONDITIONS IOH = − 4 mA IOL = 4 mA "10 µA "10 "10 µA 95 95 100 100 CKE ≤ VIL MAX, tCK = 15 ns (see Note 6) 1 1 CKE and CK ≤ VIL MAX, tCK = ∞ (see Note 7) 1 1 CKE ≥ VIH MIN, tCK = 15 ns (see Note 6) 30 30 CKE ≥ VIH MIN, CK ≤ VIL MAX, tCK = ∞ (see Note 7) 2 2 CKE ≤ VIL MAX, tCK = 15 ns (see Notes 3 and 6) 3 3 CKE and CK ≤ VIL MAX, tCK = ∞ (see Notes 3 and 7) 3 3 CKE ≥ VIH MIN, tCK = 15 ns (see Notes 3 and 6) 40 40 CKE ≥ VIH MIN, CK ≤ VIL MAX, tCK = ∞ (see Notes 3 and 7) 10 10 Page burst, IOH/IOL = 0 mA CAS latency = 2 All banks activated, nCCD = one cycle CAS latency = 3 (see Notes 8 and 9) 140 140 150 150 CAS latency = 2 90 90 CAS latency = 3 95 95 0.4 0.4 0 V ≤ VO ≤ VDD, Output disabled Operating current Burst length = 1, CAS latency = 2 tRC ≥ tRC MIN IOH/IOL = 0 mA, one bank activated CAS latency = 3 (see Notes 3, 4, and 5) ICC2NS ICC3P ICC3PS ICC3N ICC3NS ICC4 ICC5 Active standby current in power-down mode Active standby current in non-power-down mode Burst current Auto-refresh current tRC ≤ tRC MIN (see Note 7) ICC6 Self-refresh current CKE ≤ VIL MAX † Specifications in this table represent a single SDRAM device. NOTES: 3. Only one bank is activated. 4. tRC = MIN 5. Control, DQ, and address inputs change state only twice during tRC. 6. Control, DQ, and address inputs change state only once every 30 ns. 7. Control, DQ, and address inputs do not change state (stable). 8. Control, DQ, and address inputs change state only once every cycle. 9. Continuous burst access, nCCD = 1 cycle. 10 V "10 Output current (leakage) Precharge standby current in non-power-down mode 2.4 UNIT V IO ICC2N MAX 0.4 Input current (leakage) Precharge standby current in power-down mode MIN 0.4 II ICC2P ICC2PS ’xTRxxEPH-8A MAX 2.4 0 V ≤ VI ≤ VDD + 0.3 V, All other pins = 0 V to VDD ICC1 MIN POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 mA mA mA mA mA mA mA mA SMMS702B − JANUARY 1998 − REVISED APRIL 1998 ac timing requirements† ‡§ ’xTRxxEPH-8 MIN ’xTRxxEPH-8A MAX MIN MAX UNIT tCK2 tCK3 Cycle time, CLK, CAS latency = 2 10 15 ns Cycle time, CLK, CAS latency = 3 8 8 ns tCH tCL Pulse duration, CLK high 3 3 ns Pulse duration, CLK low 3 tAC2 tAC3 Access time, CLK high to data out, CAS latency = 2 (see Note 10) 6 7.5 ns Access time, CLK high to data out, CAS latency = 3 (see Note 10) 6 6 ns tOH tOHN Hold time, CLK high to data out with 50-pF load 3 3 ns Hold time, CLK high to data out with 0-pF load 2 2 ns tLZ tHZ Delay time, CLK high to DQ in low-impedance state (see Note 11) 1 tIS tIH Setup time, address, control, and data input 2 2 ns Hold time, address, control, and data input 1 1 ns tCESP tRAS Power-down/self-refresh exit time 8 8 Delay time, ACTV command to DEAC or DCAB command 48 tRC Delay time, ACTV, REFR, or SLFR exit to ACTV, MRS, REFR, or SLFR command 68 68 ns tRCD Delay time, ACTV command to READ, READ-P, WRT, or WRT-P command (see Note 13) 20 20 ns tRP tRRD Delay time, DEAC or DCAB command to ACTV, MRS, REFR, or SLFR command 20 20 ns Delay time, ACTV command in one bank to ACTV command in the other bank 16 16 ns tRSA tAPR Delay time, MRS command to ACTV, MRS, REFR, or SLFR command 16 16 ns tAPW Final data in of WRT-P operation to ACTV, MRS, SLFR, or REFR command tT tREF Transition time (see Note 14) nCCD nCDD Delay time, READ or WRT command to an interrupting command 1 Delay time, CS low or high to input enabled or disabled 0 0 0 0 cycle nCLE nCWL Delay time, CKE high or low to CLK enabled or disabled 1 1 1 1 cycle Delay time, final data in of WRT operation to READ, READ-P, WRT, WRT-P 1 nDID nDOD Delay time, ENBL or MASK command to enabled or masked data in 0 0 0 0 cycle Delay time, ENBL or MASK command to enabled or masked data out 2 2 2 2 cycle Delay time, CLK high to DQ in high-impedance state (see Note 12) 3 1 8 Final data out of READ-P operation to ACTV, MRS, SLFR, or REFR command 1 Refresh interval ns 100 000 ns 8 48 ns ns 100 000 ns tRP − (CL −1) * tCK ns tRP + 1 tCK ns 5 1 64 5 64 1 ns ms cycle 1 cycle nHZP2 Delay time, DEAC or DCAB command to DQ in high-impedance state, CAS latency = 2 2 2 cycle nHZP3 Delay time, DEAC or DCAB command to DQ in high-impedance state, CAS latency = 3 3 3 cycle nWCD Delay time, WRT command to first data in 0 cycle 0 0 0 nWR Delay time, final data in of WRT operation to DEAC or DCAB command 1 1 cycle † See Parameter Measurement Information for load circuits in the TMS626812B data sheet (literature number SMOS693). ‡ All references are made to the rising transition of CLK, unless otherwise noted. § Specifications in this table represent a single SDRAM device. NOTES: 10. tAC is referenced from the rising transition of CLK that precedes the data-out cycle. For example, the first data-out tAC is referenced from the rising transition of CLK0 that is CAS latency minus one cycle after the READ command. Access time is measured at output reference level 1.4 V. 11. tLZ is measured from the rising transition of CLK that is CAS latency minus one cycle after the READ command. 12. tHZ MAX defines the time at which the outputs are no longer driven and is not referenced to output voltage levels. 13. For read or write operations with automatic deactivate, tRCD must be set to satisfy minimum tRAS. 14. Transition time, tT, is measured between VIH and VIL. POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 11 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 serial presence detect The serial presence detect (SPD) is contained in a 256-byte serial EEPROM located on the module. The SPD nonvolatile EEPROM contains various data such as module configuration, SDRAM organization, and timing parameters (see Table 1 − Table 4). Only the first 128 bytes are programmed by Texas Instruments, while the remaining 128 bytes are available for customer use. Programming is done through an IIC bus using the clock (SCL) and data (SDA) signals. All Texas Instruments modules comply with the current JEDEC SPD Standard. See the Texas Instruments Serial Presence Detect Technical Reference (literature number SMMU001) for further details. SPD contents of each TMxTRxxEPH device are listed in the following tables: Table 1 − TM2TR64EPH Table 3 − TM2TR72EPH Table 2 − TM4TR64EPH Table 4 − TM4TR72EPH Table 1. Serial Presence Detect Data for the TM2TR64EPH TM2TR64EPH-8 BYTE NO. TM2TR64EPH-8A ITEM DATA ITEM DATA 0 Defines number of bytes written into serial memory during module manufacturing 128 bytes 80h 128 bytes 80h 1 Total number of bytes of SPD memory device 256 bytes 08h 256 bytes 08h 2 Fundamental memory type (FPM, EDO, SDRAM, . . .) SDRAM 04h SDRAM 04h 3 Number of row addresses on this assembly 11 0Bh 11 0Bh 4 Number of column addresses on this assembly 9 09h 9 09h 5 Number of module rows on this assembly 1 bank 01h 1 bank 01h 6 Data width of this assembly 64 bits 40h 64 bits 40h 7 Data width continuation 8 Voltage interface standard of this assembly LVTTL 01h LVTTL 01h 9 SDRAM cycle time at maximum supported CAS latency (CL), CL = X tCK = 8 ns 80h tCK = 8 ns 80h 10 SDRAM access from clock at CL = X tAC = 6 ns 60h tAC = 6 ns 60h 11 DIMM configuration type (non-parity, parity, error correcting code [ECC]) Non-Parity 00h Non-Parity 00h 12 Refresh rate / type 15.6 µs/ self-refresh 80h 15.6 µs/ self-refresh 80h 13 SDRAM width, primary DRAM x8 08h x8 08h 14 Error-checking SDRAM data width N/A 00h N/A 00h 15 Minimum clock delay, back-to-back random column addresses 1 CK cycle 01h 1 CK cycle 01h 16 Burst lengths supported 1, 2, 4, 8 0Fh 1, 2, 4, 8 0Fh 17 Number of banks on each SDRAM device 2 banks 02h 2 banks 02h 18 CAS latencies supported 2, 3 06h 2, 3 06h 19 CS latency 0 01h 0 01h 20 Write latency 0 01h 0 01h 00h Non-buffered/ Non-registered 00h VDD tolerance = (+10%) precharge all, auto precharge 0Eh VDD tolerance = (+10%), Burst read / write, precharge all, auto precharge 0Eh tCK = 10 ns A0h tCK = 15 ns F0h 21 12 DESCRIPTION OF FUNCTION 00h Non-buffered/ Non-registered SDRAM module attributes 22 SDRAM device attributes: general 23 Minimum clock cycle time at CL = X − 1 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 00h SMMS702B − JANUARY 1998 − REVISED APRIL 1998 serial presence detect (continued) Table 1. Serial Presence Detect Data for the TM2TR64EPH (Continued) TM2TR64EPH-8 BYTE NO. DESCRIPTION OF FUNCTION 24 Maximum data-access time from clock at CL = X − 1 25 Minimum clock cycle time at CL = X − 2 26 Maximum data-access time from clock at CL = X − 2 27 Minimum row-precharge time 28 Minimum row-active to row-active delay 29 Minimum RAS-to-CAS delay 30 Minimum RAS pulse width 31 Density of each bank on module 32 Command and address signal input setup time 33 Command and address signal input hold time 34 35 36−61 TM2TR64EPH-8A ITEM DATA ITEM DATA tAC = 6 ns N/A 60h 75h 00h tAC = 7.5 ns N/A N/A 00h N/A 00h tRP = 20 ns tRRD = 16 ns tRCD = 20 ns 14h tRP = 20 ns tRRD = 16 ns tRCD = 20 ns 14h tRAS = 48 ns 16M Bytes 30h tRAS = 48 ns 16M Bytes 30h 20h 20h tIS = 2 ns tIH = 1 ns tIS = 2 ns 20h Data signal input setup time tIS = 2 ns tIH = 1 ns tIS = 2 ns Data signal input hold time tIH = 1 ns 10h tIH = 1 ns 10h Rev. 1.2 12h Rev. 1.2 12h 10h 14h 04h 10h 00h 10h 14h 04h 10h 20h Superset features (may be used in the future) 62 SPD revision 63 Checksum for byte 0 −62 80 50h 181 B5h 97h 9700...00h 97h 9700...00h 72 Manufacturer’s JEDEC ID code per JEP −106E Manufacturing location† 73 Manufacturer’s part number T 54h T 54h 74 Manufacturer’s part number M 4Dh M 4Dh 75 Manufacturer’s part number 2 32h 2 32h 76 Manufacturer’s part number T 54h T 54h 77 Manufacturer’s part number R 52h R 52h 78 Manufacturer’s part number 6 36h 6 36h 79 Manufacturer’s part number 4 34h 4 34h 80 Manufacturer’s part number E 45h E 45h 81 Manufacturer’s part number P 50h P 50h 82 Manufacturer’s part number H 4Eh H 4Eh 83 Manufacturer’s part number − 2Dh − 2Dh 84 Manufacturer’s part number 8 38h 8 38h 85 Manufacturer’s part number SPACE 20h A 41h 86−90 Manufacturer’s part number Die revision code† SPACE 20h SPACE 20h 64 −71 91 TBD TBD TBD TBD TBD TBD 93−94 PCB revision code† Manufacturing date† TBD TBD 95−98 Assembly serial number† TBD TBD 99−125 Manufacturer-specific data† TBD 92 126 Clock frequency 127 SDRAM component and clock interconnection details System-integrator-specific data‡ 128−166 TBD 100 MHz 64h 199 C7h TBD 100 MHz 64h 199 C7h TBD 167−255 Open † TBD indicates values that are determined at manufacturing time and are module-dependent. ‡ These TBD values are determined and programmed by the customer (optional). POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 13 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 serial presence detect (continued) Table 2. Serial Presence Detect Data for the TM4TR64EPH TM4TR64EPH-8 BYTE NO. TM4TR64EPH-8A ITEM DATA ITEM DATA 0 Defines number of bytes written into serial memory during module manufacturing 128 bytes 80h 128 bytes 80h 1 Total number of bytes of SPD memory device 256 bytes 08h 256 bytes 08h 2 Fundamental memory type (FPM, EDO, SDRAM, . . .) SDRAM 04h SDRAM 04h 3 Number of row addresses on this assembly 11 0Bh 11 0Bh 4 Number of column addresses on this assembly 9 09h 9 09h 5 Number of module rows on this assembly 2 banks 02h 2 banks 02h 6 Data width of this assembly 64 bits 40h 64 bits 40h 7 Data width continuation 8 Voltage interface standard of this assembly LVTTL 01h LVTTL 01h 9 SDRAM cycle time at maximum supported CAS latency (CL), CL = X tCK = 8 ns 80h tCK = 8 ns 80h 10 SDRAM access from clock at CL = X tAC = 6 ns 60h tAC = 6 ns 60h 11 DIMM configuration type (non-parity, parity, error correcting code [ECC]) Non-Parity 00h Non-Parity 00h 12 Refresh rate / type 15.6 µs/ self-refresh 80h 15.6 µs/ self-refresh 80h 13 SDRAM width, primary DRAM 14 Error-checking SDRAM data width 15 Minimum clock delay, back-to-back random column addresses 16 00h 00h x8 08h x8 08h N/A 00h N/A 00h 1 CK cycle 01h 1 CK cycle 01h Burst lengths supported 1, 2, 4, 8 0Fh 1, 2, 4, 8 0Fh 17 Number of banks on each SDRAM device 2 banks 02h 2 banks 02h 18 CAS latencies supported 2, 3 06h 2, 3 06h 19 CS latency 0 01h 0 01h 20 Write latency 0 01h 0 01h 00h Non-buffered/ Non-registered 00h 0Eh VDD tolerance = (+10%), Burst read / write, precharge all, auto precharge 0Eh 21 14 DESCRIPTION OF FUNCTION Non-buffered/ Non-registered SDRAM module attributes VDD tolerance = (+10%) Burst read / write, precharge all, auto precharge 22 SDRAM device attributes: general 23 Minimum clock cycle time at CL = X − 1 24 Maximum data-access time from clock at CL = X − 1 25 26 tCK = 10 ns tAC = 6 ns A0h Minimum clock cycle time at CL = X − 2 N/A Maximum data-access time from clock at CL = X − 2 N/A POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 F0h 00h tCK = 15 ns tAC = 7.5 ns N/A 00h N/A 00h 60h 75h 00h SMMS702B − JANUARY 1998 − REVISED APRIL 1998 serial presence detect (continued) Table 2. Serial Presence Detect Data for the TM4TR64EPH (Continued) BYTE NO. TM4TR64EPH-8 DESCRIPTION OF FUNCTION TM4TR64EPH-8A ITEM DATA ITEM DATA tRP = 20 ns tRRD = 16 ns 14h tRP = 20 ns tRRD = 16 ns 14h tRCD = 20 ns tRAS = 48 ns 14h 14h 27 Minimum row-precharge time 28 Minimum row-active to row-active delay 29 Minimum RAS-to-CAS delay 30 Minimum RAS pulse width 30h tRCD = 20 ns tRAS = 48 ns 31 Density of each bank on module 16M Bytes 04h 16M Bytes 04h 32 Command and address signal input setup time 20h Command and address signal input hold time tIS = 2 ns tIH = 1 ns 20h 33 tIS = 2 ns tIH = 1 ns 34 Data signal input setup time 20h Data signal input hold time 10h tIS = 2 ns tIH = 1 ns 20h 35 tIS = 2 ns tIH = 1 ns Rev. 1.2 12h Rev. 1.2 12h 36−61 10h 10h 10h 30h 10h 10h Superset features (may be used in the future) 62 SPD revision 63 Checksum for byte 0 −62 81 51h 182 B6h 97h 9700...00h 97h 9700...00h 72 Manufacturer’s JEDEC ID code per JEP −106E Manufacturing location† 73 Manufacturer’s part number T 54h T 54h 74 Manufacturer’s part number M 4Dh M 4Dh 75 Manufacturer’s part number 4 34h 4 34h 76 Manufacturer’s part number T 54h T 54h 77 Manufacturer’s part number R 52h R 52h 78 Manufacturer’s part number 6 36h 6 36h 79 Manufacturer’s part number 4 34h 4 34h 80 Manufacturer’s part number E 45h E 45h 81 Manufacturer’s part number P 50h P 50h 82 Manufacturer’s part number H 4Eh H 4Eh 83 Manufacturer’s part number − 2Dh − 2Dh 84 Manufacturer’s part number 8 38h 8 38h 85 Manufacturer’s part number SPACE 20h A 41h 86−90 Manufacturer’s part number Die revision code† SPACE 20h SPACE 20h 64 −71 91 TBD TBD TBD TBD TBD TBD 93−94 PCB revision code† Manufacturing date† TBD TBD 95−98 Assembly serial number† TBD TBD 99−125 Manufacturer-specific data† 92 TBD 126 Clock frequency 127 SDRAM component and clock interconnection details System-integrator-specific data‡ 128−166 TBD 100 MHz 64h 247 F7h TBD 100 MHz 64h 247 F7h TBD 167−255 Open † TBD indicates values that are determined at manufacturing time and are module-dependent. ‡ These TBD values are determined and programmed by the customer (optional). POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 15 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 serial presence detect (continued) Table 3. Serial Presence Detect Data for the TM2TR72EPH TM2TR72EPH-8 BYTE NO. TM2TR72EPH-8A ITEM DATA ITEM DATA 0 Defines number of bytes written into serial memory during module manufacturing 128 bytes 80h 128 bytes 80h 1 Total number of bytes of SPD memory device 256 bytes 08h 256 bytes 08h 2 Fundamental memory type (FPM, EDO, SDRAM, . . .) SDRAM 04h SDRAM 04h 3 Number of row addresses on this assembly 11 0Bh 11 0Bh 4 Number of column addresses on this assembly 9 09h 9 09h 5 Number of module rows on this assembly 1 bank 01h 1 bank 01h 6 Data width of this assembly 72 bits 48h 72 bits 48h 7 Data width continuation 8 Voltage interface standard of this assembly LVTTL 01h LVTTL 01h 9 SDRAM cycle time at maximum supported CAS latency (CL), CL = X tCK = 8 ns 80h tCK = 8 ns 80h 10 SDRAM access from clock at CL = X tAC = 6 ns 60h tAC = 6 ns 60h 11 DIMM configuration type (non-parity, parity, error correcting code [ECC]) ECC 02h ECC 02h 12 Refresh rate / type 15.6 µs/ self-refresh 80h 15.6 µs/ self-refresh 80h 13 SDRAM width, primary DRAM x8 08h x8 08h 14 Error-checking SDRAM data width x8 08h x8 08h 15 Minimum clock delay, back-to-back random column addresses 1 CK cycle 01h 1 CK cycle 01h 16 Burst lengths supported 1, 2, 4, 8 0Fh 1, 2, 4, 8 0Fh 17 Number of banks on each SDRAM device 2 banks 02h 2 banks 02h 18 CAS latencies supported 2, 3 06h 2, 3 06h 19 CS latency 0 01h 0 01h 20 Write latency 0 01h 0 01h 00h Non-buffered/ Non-registered 00h 0Eh VDD tolerance = (+10%) , Burst read / write, precharge all, auto precharge 0Eh 21 16 DESCRIPTION OF FUNCTION 00h Non-buffered/ Non-registered SDRAM module attributes VDD tolerance = (+10%) Burst read / write, precharge all, auto precharge 22 SDRAM device attributes: general 23 Minimum clock cycle time at CL = X − 1 24 Maximum data-access time from clock at CL = X − 1 POST OFFICE BOX 1443 tCK = 10 ns tAC = 6.0 ns • HOUSTON, TEXAS 77251−1443 A0h 60h 00h tCK = 15 ns tAC = 7.5 ns F0h 75h SMMS702B − JANUARY 1998 − REVISED APRIL 1998 serial presence detect (continued) Table 3. Serial Presence Detect Data for the TM2TR72EPH (Continued) BYTE NO. TM2TR72EPH-8 DESCRIPTION OF FUNCTION 25 Minimum clock cycle time at CL = X − 2 26 Maximum data-access time from clock at CL = X − 2 27 Minimum row-precharge time 28 Minimum row-active to row-active delay 29 Minimum RAS-to-CAS delay 30 Minimum RAS pulse width 31 Density of each bank on module 32 Command and address signal input setup time 33 Command and address signal input hold time 34 Data signal input setup time 35 Data signal input hold time 36−61 TM2TR72EPH-8A ITEM DATA ITEM DATA N/A 00h N/A 00h N/A 00h N/A 00h tRP = 20 ns 14h tRP = 20 ns 14h tRRD = 16 ns tRCD = 20 ns 10h tRRD = 16 ns tRCD = 20 ns 10h tRAS = 48 ns 16M Bytes 30h tRAS = 48 ns 16M Bytes 30h tIS = 2 ns tIH = 1 ns 20h tIS = 2 ns tIH = 1 ns 20h tIS = 2 ns tIH = 1 ns 20h 20h 10h tIS = 2 ns tIH = 1 ns Rev. 1.2 12h Rev. 1.2 12h 14h 04h 10h 14h 04h 10h 10h Superset features (may be used in the future) 62 SPD revision 63 Checksum for byte 0 −62 98 62h 199 C7h 97h 9700...00h 97h 9700...00h 72 Manufacturer’s JEDEC ID code per JEP −106E Manufacturing location† 73 Manufacturer’s part number T 54h T 54h 74 Manufacturer’s part number M 4Dh M 4Dh 75 Manufacturer’s part number 2 32h 2 32h 76 Manufacturer’s part number T 54h T 54h 77 Manufacturer’s part number R 52h R 52h 78 Manufacturer’s part number 7 37h 7 37h 79 Manufacturer’s part number 2 32h 2 32h 80 Manufacturer’s part number E 45h E 45h 81 Manufacturer’s part number P 50h P 50h 82 Manufacturer’s part number H 4Eh H 4Eh 83 Manufacturer’s part number − 2Dh − 2Dh 84 Manufacturer’s part number 8 38h 8 38h 85 Manufacturer’s part number SPACE 20h A 41h 86−90 Manufacturer’s part number Die revision code† SPACE 20h SPACE 20h 64 −71 91 TBD TBD TBD TBD TBD TBD 93−94 PCB revision code† Manufacturing date† TBD TBD 95−98 Assembly serial number† TBD TBD 99−125 Manufacturer-specific data† TBD 92 126 Clock frequency 127 SDRAM component and clock interconnection details System-integrator-specific data ‡ 128−166 TBD 100 MHz 64h 199 C7h TBD 100 MHz 64h 199 C7h TBD 167−255 Open † TBD indicates values that are determined at manufacturing time and are module-dependent. ‡ These TBD values are determined and programmed by the customer (optional). POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 17 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 serial presence detect (continued) Table 4. Serial Presence Detect Data for the TM4TR72EPH TM4TR72EPH-8 BYTE NO. TM4TR72EPH-8A ITEM DATA ITEM DATA 0 Defines number of bytes written into serial memory during module manufacturing 128 bytes 80h 128 bytes 80h 1 Total number of bytes of SPD memory device 256 bytes 08h 256 bytes 08h 2 Fundamental memory type (FPM, EDO, SDRAM, . . .) SDRAM 04h SDRAM 04h 3 Number of row addresses on this assembly 11 0Bh 11 0Bh 4 Number of column addresses on this assembly 9 09h 9 09h 5 Number of module rows on this assembly 2 banks 02h 2 banks 02h 6 Data width of this assembly 72 bits 48h 72 bits 48h 7 Data width continuation 8 Voltage interface standard of this assembly LVTTL 01h LVTTL 01h 9 SDRAM cycle time at maximum supported CAS latency (CL), CL = X tCK = 8 ns 80h tCK = 8 ns 80h 10 SDRAM access from clock at CL = X tAC = 6 ns 60h tAC = 6 ns 60h 11 DIMM configuration type (non-parity, parity, error correcting code [ECC]) ECC 02h ECC 02h 12 Refresh rate / type 15.6 µs/ self-refresh 80h 15.6 µs/ self-refresh 80h 13 SDRAM width, primary DRAM x8 08h x8 08h 14 Error-checking SDRAM data width x8 08h x8 08h 15 Minimum clock delay, back-to-back random column addresses 1 CK cycle 01h 1 CK cycle 01h 16 Burst lengths supported 1, 2, 4, 8 0Fh 1, 2, 4, 8 0Fh 17 Number of banks on each SDRAM device 2 banks 02h 2 banks 02h 18 CAS latencies supported 2, 3 06h 2, 3 06h 19 CS latency 0 01h 0 01h 20 Write latency 0 01h 0 01h 00h Non-buffered/ Non-registered 00h 0Eh VDD tolerance = (+10%) , Burst read / write, precharge all, auto precharge 0Eh 21 18 DESCRIPTION OF FUNCTION 00h Non-buffered/ Non-registered SDRAM module attributes VDD tolerance = (+10%) Burst read / write, precharge all, auto precharge 22 SDRAM device attributes: general 23 Minimum clock cycle time at CL = X − 1 24 Maximum data-access time from clock at CL = X − 1 25 Minimum clock cycle time at CL = X − 2 26 Maximum data-access time from clock at CL = X − 2 27 Minimum row-precharge time 28 Minimum row-active to row-active delay 29 Minimum RAS-to-CAS delay 30 Minimum RAS pulse width 31 Density of each bank on module POST OFFICE BOX 1443 tCK = 10 ns tAC = 6.0 ns N/A A0h N/A 00h F0h 00h tCK = 15 ns tAC = 7.5 ns N/A 00h N/A 00h tRP = 20 ns tRRD = 16 ns 14h tRP = 20 ns tRRD = 16 ns 14h tRCD = 20 ns tRAS = 48 ns 14h 14h 30h tRCD = 20 ns tRAS = 48 ns 16M Bytes 04h 16M Bytes 04h • HOUSTON, TEXAS 77251−1443 60h 10h 75h 00h 10h 30h SMMS702B − JANUARY 1998 − REVISED APRIL 1998 serial presence detect (continued) Table 4. Serial Presence Detect Data for the TM4TR72EPH (Continued) BYTE NO. TM4TR72EPH-8 DESCRIPTION OF FUNCTION 32 Command and address signal input setup time 33 Command and address signal input hold time 34 Data signal input setup time 35 Data signal input hold time 36 −61 TM4TR72EPH-8A ITEM DATA ITEM DATA tIS = 2 ns tIH = 1 ns 20h tIS = 2 ns tIH = 1 ns 20h tIS = 2 ns tIH = 1 ns 20h 20h 10h tIS = 2 ns tIH = 1 ns Rev. 1.2 12h Rev. 1.2 12h 10h 10h 10h Superset features (may be used in the future) 62 SPD revision 63 Checksum for byte 0 −62 99 63h 200 C8h 97h 9700...00h 97h 9700...00h 72 Manufacturer’s JEDEC ID code per JEP −106E Manufacturing location† 73 Manufacturer’s part number T 54h T 54h 74 Manufacturer’s part number M 4Dh M 4Dh 75 Manufacturer’s part number 4 34h 4 34h 76 Manufacturer’s part number T 54h T 54h 77 Manufacturer’s part number R 52h R 52h 78 Manufacturer’s part number 7 37h 7 37h 79 Manufacturer’s part number 2 32h 2 32h 80 Manufacturer’s part number E 45h E 45h 81 Manufacturer’s part number P 50h P 50h 82 Manufacturer’s part number H 4Eh H 4Eh 83 Manufacturer’s part number − 2Dh − 2Dh 84 Manufacturer’s part number 8 38h 8 38h 85 Manufacturer’s part number SPACE 20h A 41h 86−90 Manufacturer’s part number Die revision code† SPACE 20h SPACE 20h 64 −71 91 TBD TBD TBD TBD TBD TBD 93−94 PCB revision code† Manufacturing date† TBD TBD 95−98 Assembly serial number† TBD TBD 99−125 Manufacturer-specific data† TBD 92 126 Clock frequency 127 SDRAM component and clock interconnection details System-integrator-specific data‡ 128−166 TBD 100 MHz 64h 247 F7h TBD 100 MHz 64h 247 F7h TBD 167−255 Open † TBD indicates values that are determined at manufacturing time and are module-dependent. ‡ These TBD values are determined and programmed by the customer (optional). POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 19 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 device symbolization (TM2TR64EPH illustrated) TM2TR64EPH -SS Unbuffered Key Position 3.3-V Voltage Key Position YY MM T -SS = = = = Year Code Month Code Assembly Site Code Speed Code NOTE A: Location of symbolization may vary. 20 YYMMT POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 SMMS702B − JANUARY 1998 − REVISED APRIL 1998 MECHANICAL DATA BUV (R-PDIM-N168) DUAL-IN-LINE MEMORY MODULE 5.255 (133,48) 5.245 (133,22) (Note D) Notch 0.250 (6,35) x 0.089 (2,26) Deep 2 Places 0.054 (1,37) 0.046 (1,17) Notch 0.079 (2,00) x 0.122 (3,10) Deep 2 Places Notch 0.157 (4,00) x 0.122 (3,10) Deep 2 Places 2 Places 0.050 (1,27) 0.039 (1,00) TYP 0.125 (3,18) 0.014 (0,35) MAX 0.118 (3,00) TYP 0.125 (3,18) 0.700 (17,78) TYP 0.118 (3,00) DIA (2 Places) 1.255 (31,88) 1.245 (31,62) 0.875 (22,23) 2 Places 0.106 (2,70) MAX 0.157 (4,00) MAX (For Double Sided DIMM Only) 4088192/A 01/98 NOTES: A. B. C. D. E. All linear dimensions are in inches (millimeters). This drawing is subject to change without notice. Falls within JEDEC MO-161 Dimension includes depanelization variations; applies between notch and tab edge. Outline may vary above notches to allow router/panelization irregularities. POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251−1443 21 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Amplifiers Data Converters DSP Clocks and Timers Interface Logic Power Mgmt Microcontrollers RFID RF/IF and ZigBee® Solutions amplifier.ti.com dataconverter.ti.com dsp.ti.com www.ti.com/clocks interface.ti.com logic.ti.com power.ti.com microcontroller.ti.com www.ti-rfid.com www.ti.com/lprf Applications Audio Automotive Broadband Digital Control Medical Military Optical Networking Security Telephony Video & Imaging Wireless www.ti.com/audio www.ti.com/automotive www.ti.com/broadband www.ti.com/digitalcontrol www.ti.com/medical www.ti.com/military www.ti.com/opticalnetwork www.ti.com/security www.ti.com/telephony www.ti.com/video www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2008, Texas Instruments Incorporated