SCAS198A − OCTOBER 1990 − REVISED APRIL 1996 D Members of the Texas Instruments D D D D D D D 54ACT16475 . . . WD PACKAGE 74ACT16475 . . . DL PACKAGE (TOP VIEW) Widebus Family Inputs Are TTL-Voltage Compatible 3-State Inverting Outputs Flow-Through Architecture Optimizes PCB Layout Distributed VCC and GND Pin Configuration Minimizes High-Speed Switching Noise EPIC (Enhanced-Performance Implanted CMOS) 1-µm Process 500-mA Typical Latch-Up Immunity at 125°C Packaged in Plastic 300-mil Shrink Small-Outline (DL) Packages Using 25-mil Center-to-Center Pin Spacings and 380-mil Fine-Pitch Ceramic Flat (WD) Packages Using 25-mil Center-to-Center Pin Spacings 1OEAB 1CLKAB 1A1 GND 1A2 1A3 VCC 1A4 1A5 1A6 GND 1A7 1A8 1A9 2A1 2A2 2A3 GND 2A4 2A5 2A6 VCC 2A7 2A8 GND 2A9 2CLKAB 2OEAB description The ’ACT16475 are 18-bit registered transceivers that contain two sets of D-type flip-flops for temporary storage of data flowing in either direction. They can be used as two 9-bit transceivers or one 18-bit transceiver. Separate clock (CLKAB and CLKBA) and output-enable (OEAB or OEBA) inputs are provided for each register to permit independent control in either direction of data flow. Data at the A inputs meeting the setup time requirements is transferred to the B outputs on the positive-going edge of CLKAB. With OEAB low, the 3-state B outputs are enabled and reflect the inverted A data. Data flow from B to A is similar but requires the use of the CLKBA and OEBA inputs. 1 56 2 55 3 54 4 53 5 52 6 51 7 50 8 49 9 48 10 47 11 46 12 45 13 44 14 43 15 42 16 41 17 40 18 39 19 38 20 37 21 36 22 35 23 34 24 33 25 32 26 31 27 30 28 29 1OEBA 1CLKBA 1B1 GND 1B2 1B3 VCC 1B4 1B5 1B6 GND 1B7 1B8 1B9 2B1 2B2 2B3 GND 2B4 2B5 2B6 VCC 2B7 2B8 GND 2B9 2CLKBA 2OEBA The 74ACT16475 is packaged in TI’s shrink small-outline package, which provides twice the I/O pin count and functionality of standard small-outline packages in the same printed-circuit-board area. The 54ACT16475 is characterized for operation over the full military temperature range of −55°C to 125°C. The 74ACT16475 is characterized for operation from −40°C to 85°C. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. EPIC and Widebus are trademarks of Texas Instruments Incorporated. Copyright 1996, Texas Instruments Incorporated !"#$%&' #"'(' ')"*%("' #$**&' ( ") +$,-#("' !(&. *"!$# #"')"*% " +&#)#("' +&* & &*% ") &/( '*$%&' ('!(*! 0(**('1. *"!$#"' +*"#&'2 !"& '" '&#&(*-1 '#-$!& &'2 ") (-+(*(%&&*. • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 1 SCAS198A − OCTOBER 1990 − REVISED APRIL 1996 FUNCTION TABLE† INPUTS OUTPUT B OEAB CLKAB A H X X Z L L X L ↑ L B0‡ H L ↑ H L † A-to-B data flow is shown: B-to-A flow is similar but uses CLKBA and OEBA. ‡ Output level before the indicated steady-state input conditions were established logic symbol§ 2 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • SCAS198A − OCTOBER 1990 − REVISED APRIL 1996 1CLKAB 1OEAB 1CLKBA 1OEBA 2CLKAB 2 1 2CLKBA 56 1A3 1A4 1A5 1A6 1A7 1A8 1A9 2A1 2A2 2A3 2A4 2A5 2A6 2A7 2A8 2A9 EN4 C5 EN6 30 2OEBA 1A2 C3 27 29 1A1 EN2 55 28 2OEAB C1 3 C7 EN8 1D 1 2 4 1 3D 54 5 52 6 51 8 49 9 48 10 47 12 45 13 44 14 43 15 42 5D 1 6 8 1 7D 16 41 17 40 19 38 20 37 21 36 23 34 24 33 26 31 1B1 1B2 1B3 1B4 1B5 1B6 1B7 1B8 1B9 2B1 2B2 2B3 2B4 2B5 2B6 2B7 2B8 2B9 § This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. logic diagram (positive logic) • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 3 SCAS198A − OCTOBER 1990 − REVISED APRIL 1996 1CLKBA 1OEBA 1OEAB 1CLKAB 55 56 1 2 C1 1D 1A1 54 3 1B1 C1 1D To Eight Other Channels 2CLKBA 2OEBA 2OEAB 2CLKAB 30 29 28 27 C1 1D 2A1 42 15 C1 1D To Eight Other Channels 4 • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 2B1 SCAS198A − OCTOBER 1990 − REVISED APRIL 1996 absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V Input voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±450 mA Maximum power package dissipation at TA = 55°C (in still air) (see Note 2): DL package . . . . . . . . . . . 1.4 W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The maximum package power dissipation is calculated using a junction temperature of 150_C and a board trace length of 750 mils. recommended operating conditions (see Note 2) 54ACT16475 MIN NOM MAX MIN NOM MAX 4.5 5 5.5 4.5 5 5.5 VCC VIH Supply voltage VIL VI Low-level input voltage Input voltage 0 VO IOH Output voltage 0 High-level output current IOL ∆t/∆v Low-level output current High-level input voltage 74ACT16475 2 2 0.8 Input transition rise or fall rate 0 TA Operating free-air temperature −55 NOTE 3: Unused pins (input or I/O) must be held high or low to prevent them from floating. UNIT V V 0.8 V VCC VCC V −24 −24 mA 24 24 mA VCC VCC 0 0 V 10 0 10 ns/V 125 −40 85 °C ')"*%("' #"'#&*' +*"!$# ' & )"*%(3& "* !&2' +(& ") !&3&-"+%&'. (*(#&*# !(( ('! "&* +&#)#("' (*& !&2' 2"(-. &/( '*$%&' *&&*3& & *2 " #('2& "* !#"''$& && +*"!$# 0"$ '"#&. • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 5 SCAS198A − OCTOBER 1990 − REVISED APRIL 1996 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS 4.4 4.4 4.4 5.5 V 5.4 5.4 5.4 4.5 V 3.94 3.8 3.8 IOH = − 24 mA 5.5 V 4.94 4.8 4.8 IOH = −75 mA† 5.5 V II Control inputs IOL = 75 mA† VI = VCC or GND IOZ‡ A or B ports VO = VCC or GND Ci Control inputs 0.1 MAX MIN MAX UNIT V 3.85 0.1 0.1 5.5 V 0.1 0.1 0.1 4.5 V 0.36 0.44 0.44 5.5 V 0.36 0.44 0.44 1.65 1.65 5.5 V VI = VCC or GND, IO = 0 One input at 3.4 V, Other inputs at VCC or GND ∆ICC§ MIN 3.85 4.5 V IOL = 24 mA ICC 74ACT16475 4.5 V IOL = 50 µA A VOL 54ACT16475 MIN IOH = − 50 µA A VOH TA = 25°C TYP MAX VCC V 5.5 V ±0.1 ±1 ±1 µA 5.5 V ±0.5 ±5 ±5 µA 5.5 V 8 80 80 µA 5.5 V 0.9 1 1 mA VI = VCC or GND VO = VCC or GND 5V 4.5 pF Cio A or B ports 5V 12 † Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms. ‡ For I/O ports, the parameter IOZ includes the input leakage current. § This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC. pF timing requirements over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1) TA = 25°C MIN MAX 0 75 54ACT16475 MIN MAX 0 75 74ACT16475 MIN MAX 0 75 UNIT fclock tw Clock frequency Pulse duration CLK high or low 6.5 6.5 6.5 MHz ns tsu th Setup time Data before CLK↑ 5.5 5.5 5.5 ns Hold time Data after CLK↑ 1.5 1.5 1.5 ns switching characteristics over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1) PARAMETER fmax tPLH tPHL tPZH tPZL tPHZ tPLZ FROM (INPUT) TO (OUTPUT) MIN TA = 25°C TYP MAX 75 CLKAB or CLKBA B or A OEAB or OEBA B or A OEAB or OEBA B or A • MAX 74ACT16475 MIN MAX 75 UNIT MHz 3.8 7.9 11.1 3.8 12.5 3.8 12.5 4.2 8.1 11.4 4.2 12.6 4.2 12.6 2.8 7.3 11.4 2.8 12.8 2.8 12.8 3.4 7.4 13.1 3.4 14.8 3.4 14.8 5.2 6.5 9.8 5.2 10.5 5.2 10.5 4.5 6.6 9.1 4.5 9.8 4.5 9.8 POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • MIN 75 ')"*%("' #"'#&*' +*"!$# ' & )"*%(3& "* !&2' +(& ") !&3&-"+%&'. (*(#&*# !(( ('! "&* +&#)#("' (*& !&2' 2"(-. &/( '*$%&' *&&*3& & *2 " #('2& "* !#"''$& && +*"!$# 0"$ '"#&. 6 54ACT16475 ns ns ns SCAS198A − OCTOBER 1990 − REVISED APRIL 1996 operating characteristics, VCC = 5 V, TA = 25°C PARAMETER Cpd TEST CONDITIONS Outputs enabled Power dissipation capacitance per transceiver CL = 50 pF, Outputs disabled TYP f = 1 MHz 27 9 UNIT pF PARAMETER MEASUREMENT INFORMATION 2 × VCC S1 500 Ω From Output Under Test Open GND CL = 50 pF (see Note A) TEST S1 tPLH/tPHL tPLZ/tPZL tPHZ/tPZH Open 2 × VCC GND 500 Ω LOAD CIRCUIT 3V Timing Input 1.5 V 0V tw tsu 3V Input 1.5 V th 1.5 V 3V 1.5 V 1.5 V Data Input 0V 0V VOLTAGE WAVEFORMS VOLTAGE WAVEFORMS Output Control (low-level enabling) 3V Input 1.5 V 1.5 V 0V tPHL tPLH In-Phase Output 50% VCC Out-of-Phase Output 50% VCC 0V tPZL tPLZ Output Waveform 1 S1 at 2 × VCC (see Note B) VOH 50% VCC VOL tPLH tPHL 3V Output Waveform 2 S1 at GND (see Note B) VOH 50% VCC VOL 1.5 V 1.5 V 50% VCC 20% VCC VOL tPHZ tPZH VOLTAGE WAVEFORMS [ VCC 50% VCC 80% VCC VOH [0V VOLTAGE WAVEFORMS NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns. D. The outputs are measured one at a time with one input transition per measurement. Figure 1. Load Circuit and Voltage Waveforms • POST OFFICE BOX 655303 DALLAS, TEXAS 75265 POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443 • 7 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Amplifiers Data Converters DLP® Products DSP Clocks and Timers Interface Logic Power Mgmt Microcontrollers RFID RF/IF and ZigBee® Solutions amplifier.ti.com dataconverter.ti.com www.dlp.com dsp.ti.com www.ti.com/clocks interface.ti.com logic.ti.com power.ti.com microcontroller.ti.com www.ti-rfid.com www.ti.com/lprf Applications Audio Automotive Broadband Digital Control Medical Military Optical Networking Security Telephony Video & Imaging Wireless www.ti.com/audio www.ti.com/automotive www.ti.com/broadband www.ti.com/digitalcontrol www.ti.com/medical www.ti.com/military www.ti.com/opticalnetwork www.ti.com/security www.ti.com/telephony www.ti.com/video www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2009, Texas Instruments Incorporated