Filename: tfs 1227b.doc Version 4.0 Vectron International 03.05.2011 Filter specification TFS 1227B 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 0 °C dBm 50 50 Ω Ω Characteristics Remark: The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1227,6 MHz without any tolerance or limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss in PB Insertion loss in PB1 ae 2,4 1,5 Nominal frequency fN - PB PB1 - Passband Passband 0,4 Pass band variation in PB1 Absolute attenuation 0,3 MHz … 1127 1127 MHz … 1167 1167 MHz … 1177 1197,6 tolerance / limit dB dB max. max. 4,0 2,0 1227,6 fN fN ± ± 12,0 5,0 1,0 dB dB MHz MHz MHz dB max. dB dB dB dB dB dB min. min. min. min. 32 42 32 6 dB dB dB dB** min. min. min. min. max. max. 11 32 42 32 50 30 dB*** dB dB dB ns ns aabs MHz MHz MHz MHz 43 49 46 25 1257,6 MHz 1277 MHz … 1287 MHz 1287 MHz … 1327 MHz 1327 MHz … 3000 MHz Group delay ripple within PB Group delay ripple within PB1 35 55 54 37 35 12 dB dB dB ns ns VSWR within PB 1,6 : 1 max. 2:1 Input power level in PB - max. 15 - - 45 °C ... + 85°C - - 55 °C ... + 105°C Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf * -42 dBm ppm/K *) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz). **) stop band attenuation between 1177,0MHz and 1197,6MHz decreases linearly from 32dB to 6dB ***) stop band attenuation between 1257,6MHz and 1277,0MHz increases linearly from 11dB to 32dB Generated: Checked / Approved: Vectron International GmbH & Co. KG Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1227b.doc Version 4.0 Vectron International 03.05.2011 Filter specification TFS 1227B 2/5 0 -1 0.135 -20 -2 0.12 -30 -3 0.105 -40 -4 0.09 -5 0.075 -6 0.06 -70 -7 0.045 -80 -8 0.03 -90 -9 0.015 -50 -60 -100 5 305 605 905 1205 1505 1805 frequency in MHz 2105 2405 2705 -10 3005 1210 1215 1220 1225 1230 frequency in MHz 1235 1240 1245 delay in µs 0 -10 magnitude in dB magnitude in dB Filter characteristic 0 Construction and pin connection (All dimensions in mm) 5 6 4 1,2 Max. C27B ● B19 2 1 1 2 3 4 5 6 Ground Input Ground Ground Output Ground Date code: B C D ... Year + week 2011 2012 2013 3 Date code 3 0,75 3,0 +/-0,15 0,30X0,30 1 0,6 6 4 0,6 50 Ω Test circuit L1 2 5 L2 SAW 1, 3, 4, 6 Vectron International GmbH & Co. KG Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1227b.doc Version 4.0 Vectron International 03.05.2011 Filter specification TFS 1227B 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plane, 3 planes; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): 5. ESD -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions, see page 4: "Air reflow temperature conditions" ANSI/ESD S20.20-1999, class 1A for HBM This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: Alinment 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 8,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 3,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 4,00 ± 0,1 D1(min) : 1,50 Ao : 3,25 ± 0,1 Bo : 3,25 ± 0,1 Ct : 5,3 ± 0,1 P1 t PIN Marker Po P2 G Ct Bo F G E Do W Tape & Reel: Ko Date Code Typ D1 Ao W 2 Reel (all dimensions in mm) A : 180 W1 : 8,4 +1,5/-0 W2(max) : 14,4 N(min) : 60 C : 13,0 ± 0,2 A C N W 1 The minimum bending radius is 45 mm. Vectron International GmbH & Co. KG Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1227b.doc Version 4.0 Vectron International 03.05.2011 Filter specification TFS 1227B 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Vectron International GmbH & Co. KG Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 1227b.doc Vectron International Version 4.0 Filter specification 03.05.2011 TFS 1227B 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Noack 09.07.2010 2.0 - Change of data table according to new customer requirements Noack 23.07.2010 3.0 - Change of data table according to new customer requirements Noack 27.07.2010 4.0 - Change alignment of tape and reel - Add typical values and filter characteristic - Generation of filter specification Noack 03.05.2011 Automatically replaced footer by standard footer. Automatically replaced header by standard header. Abschnitt Construction wurde bearbeitet. Vectron International GmbH & Co. KG Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.