1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
0
°C
dBm
50
50
Ω
Ω
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1227,6 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss in PB
Insertion loss in PB1
ae
2,4
1,5
Nominal frequency
fN
-
PB
PB1
-
Passband
Passband
0,4
Pass band variation in PB1
Absolute attenuation
0,3
MHz … 1127
1127
MHz … 1167
1167
MHz … 1177
1197,6
tolerance / limit
dB
dB
max.
max.
4,0
2,0
1227,6
fN
fN
±
±
12,0
5,0
1,0
dB
dB
MHz
MHz
MHz
dB
max.
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
32
42
32
6
dB
dB
dB
dB**
min.
min.
min.
min.
max.
max.
11
32
42
32
50
30
dB***
dB
dB
dB
ns
ns
aabs
MHz
MHz
MHz
MHz
43
49
46
25
1257,6
MHz
1277
MHz … 1287
MHz
1287
MHz … 1327
MHz
1327
MHz … 3000
MHz
Group delay ripple within PB
Group delay ripple within PB1
35
55
54
37
35
12
dB
dB
dB
ns
ns
VSWR within PB
1,6 : 1
max.
2:1
Input power level in PB
-
max.
15
-
- 45 °C ... + 85°C
-
- 55 °C ... + 105°C
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf *
-42
dBm
ppm/K
*) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
**) stop band attenuation between 1177,0MHz and 1197,6MHz decreases linearly from 32dB to 6dB
***) stop band attenuation between 1257,6MHz and 1277,0MHz increases linearly from 11dB to 32dB
Generated:
Checked / Approved:
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
Filename: tfs 1227b.doc
Version 4.0
Vectron International
03.05.2011
Filter specification
TFS 1227B
2/5
0
-1
0.135
-20
-2
0.12
-30
-3
0.105
-40
-4
0.09
-5
0.075
-6
0.06
-70
-7
0.045
-80
-8
0.03
-90
-9
0.015
-50
-60
-100
5
305
605
905
1205
1505
1805
frequency in MHz
2105
2405
2705
-10
3005
1210
1215
1220
1225
1230
frequency in MHz
1235
1240
1245
delay in µs
0
-10
magnitude in dB
magnitude in dB
Filter characteristic
0
Construction and pin connection
(All dimensions in mm)
5
6
4
1,2 Max.
C27B
● B19
2
1
1
2
3
4
5
6
Ground
Input
Ground
Ground
Output
Ground
Date code:
B
C
D
...
Year + week
2011
2012
2013
3
Date code
3
0,75
3,0 +/-0,15
0,30X0,30
1
0,6
6
4
0,6
50 Ω Test circuit
L1
2
5
L2
SAW
1, 3, 4, 6
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
Filename: tfs 1227b.doc
Version 4.0
Vectron International
03.05.2011
Filter specification
TFS 1227B
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per
plane, 3 planes; DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
5. ESD
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions, see page 4: "Air reflow temperature conditions"
ANSI/ESD S20.20-1999, class 1A for HBM
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
Alinment
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 8,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 3,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 4,00 ± 0,1
D1(min)
: 1,50
Ao
: 3,25 ± 0,1
Bo
: 3,25 ± 0,1
Ct
: 5,3 ± 0,1
P1
t
PIN Marker
Po
P2
G
Ct
Bo
F
G
E
Do
W
Tape & Reel:
Ko
Date Code
Typ
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 180
W1
: 8,4 +1,5/-0
W2(max) : 14,4
N(min)
: 60
C
: 13,0 ± 0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
Filename: tfs 1227b.doc
Version 4.0
Vectron International
03.05.2011
Filter specification
TFS 1227B
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
Filename: tfs 1227b.doc
Vectron International
Version 4.0
Filter specification
03.05.2011
TFS 1227B
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification
Noack
09.07.2010
2.0
- Change of data table according to new customer requirements
Noack
23.07.2010
3.0
- Change of data table according to new customer requirements
Noack
27.07.2010
4.0
- Change alignment of tape and reel
- Add typical values and filter characteristic
- Generation of filter specification
Noack
03.05.2011
Automatically replaced footer by standard footer.
Automatically replaced header by standard header.
Abschnitt Construction wurde bearbeitet.
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.