Filename: TFS602.doc Version 2.1 Vectron International 27.02.2014 Filter specification TFS 602 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 0 °C dBm 50 50 Ω Ω Characteristics Remark: The maximum attenuation in the passband is defined as the insertion loss ae. The nominal frequency fN is fixed at 602 MHz without any tolerance or limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range OTR2 is included in the production tolerance scheme. Data typ. value Insertion loss within PB (OTR1) ae ae Insertion loss within PB (OTR2) fN Nominal frequency tolerance / limit 2.0 dB max. 3.0 2.5 dB max. 4.0 - PB Passband dB dB 602 MHz fN ± 12 MHz aabs Absolute attenuation fN ± 80 MHz … fN ± 149 MHz 50 dB min. 33.5 dB fN + 149 MHz … fN + 300 MHz 50 dB min. 45 dB 200 MHz 59 dB min. 50 dB 149 MHz 64 dB min. 55 dB 11 ns max. 1 200 MHz … MHz … fN - Group delay ripple within PB p-p IIP3 * Input power level 0.2 min. 36 dBm - max. 10 dBm Operating temperature range 1 OTR1 - - 10 °C ... + 75 °C Operating temperature range 2 OTR2 - - 40 °C ... + 85 °C - - 40 °C ... + 85 °C Storage temperature range Temperature coefficient of frequency TCf ** µs - -76 ppm/K *) fin1 = fC - 14 MHz; fin2 = fC – 14.4 MHz; Pin = 0 dBm; fmeasurement1 = fC - 13.6 MHz; fmeasurement2 = fC - 14.8 MHz. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. **) ∆f(Hz) =TCf (ppm/K) x (T-T0) x fTo (MHz) Generated: Checked / Approved: Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS602.doc Version 2.1 Vectron International 27.02.2014 Filter specification TFS 602 2/5 Filter characteristic 0 0 0.5 -10 0.45 -20 -2 0.4 0.35 -50 -60 0.3 -4 0.25 -6 delay in µs -40 magnitude in dB magnitude in dB -30 0.2 -70 0.15 -80 -8 0.1 -90 0.05 -100 102 202 302 402 502 602 702 frequency in MHz 802 902 1002 -10 1102 580 585 590 595 600 605 frequency in MHz 610 615 620 625 0 Construction and pin connection (All dimensions in mm) 7 602 ● E09 1 SQ 3,81 +0,2/-0,1 5 3 7 5 0,1 12 0% 0,6 % d 3 1,78 2,54 1 Ground Input Ground Ground Ground Output Ground Ground Date code: E F G ... Year + week 2014 2015 2016 1,2 Max. Date code 1 2 3 4 5 6 7 8 1,78 50 Ω Test circuit L1 2 6 L2 SAW 1, 3, 4, 5, 7, 8 Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS602.doc Version 2.1 Vectron International 27.02.2014 Filter specification TFS 602 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0.35 mm or g respectively, 1 octave per min, 10 cycles per plane, 3 planes; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 15 min. each / 100 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions, see page 4: "Air reflow temperature conditions" This filter is RoHS compliant (2011/65/EU) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 4,30 ± 0,1 Bo : 4,30 ± 0,1 Ct : 9,2 ± 0,1 P1 Date Code Po Do P2 W G Ct Bo F G E t Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS602.doc Version 2.1 Vectron International 27.02.2014 Filter specification TFS 602 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS602.doc Vectron International Version 2.1 Filter specification 27.02.2014 TFS 602 5/5 History Version Reason of Changes Name Date 1.0 Generation of development specification Springfeldt 14.04.2004 1.1 adjust attenuation and loss to new customer requirements Noack 26.11.2004 1.2 adjust attenuation and loss to new customer requirements Martens 29.11.2004 1.3 Change of absolute attenuation Strehl 20.01.2005 1.4 Change stability characteristics add typical values and filter characteristic generation of filter specification Strehl 09.05.2005 1.5 Add IIP3 and change stability characteristics Strehl 19.07.2006 2.0 Add OTR2 S. Channaa 28.06.2011 2.1 Typos corrected Molke 27.02.2014 Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.