TFS602 - Vectron International

Filename: TFS602.doc
Version 2.1
Vectron International
27.02.2014
Filter specification
TFS 602
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
0
°C
dBm
50
50
Ω
Ω
Characteristics
Remark:
The maximum attenuation in the passband is defined as the insertion loss ae. The nominal frequency fN is fixed at 602 MHz without any tolerance or limit.
The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range OTR2 is included in the production tolerance scheme.
Data
typ. value
Insertion loss within PB (OTR1)
ae
ae
Insertion loss within PB (OTR2)
fN
Nominal frequency
tolerance / limit
2.0
dB
max.
3.0
2.5
dB
max.
4.0
-
PB
Passband
dB
dB
602
MHz
fN ± 12
MHz
aabs
Absolute attenuation
fN
±
80
MHz … fN
±
149
MHz
50
dB
min.
33.5
dB
fN
+
149
MHz … fN
+
300
MHz
50
dB
min.
45
dB
200
MHz
59
dB
min.
50
dB
149
MHz
64
dB
min.
55
dB
11
ns
max.
1
200
MHz …
MHz … fN
-
Group delay ripple within PB
p-p
IIP3
*
Input power level
0.2
min.
36
dBm
-
max.
10
dBm
Operating temperature range 1
OTR1
-
- 10 °C ... + 75 °C
Operating temperature range 2
OTR2
-
- 40 °C ... + 85 °C
-
- 40 °C ... + 85 °C
Storage temperature range
Temperature coefficient of frequency
TCf **
µs
-
-76
ppm/K
*) fin1 = fC - 14 MHz; fin2 = fC – 14.4 MHz; Pin = 0 dBm; fmeasurement1 = fC - 13.6 MHz; fmeasurement2 = fC - 14.8 MHz. The centre frequency fc
is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae.
**)
∆f(Hz) =TCf (ppm/K) x (T-T0) x fTo (MHz)
Generated:
Checked / Approved:
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS602.doc
Version 2.1
Vectron International
27.02.2014
Filter specification
TFS 602
2/5
Filter characteristic
0
0
0.5
-10
0.45
-20
-2
0.4
0.35
-50
-60
0.3
-4
0.25
-6
delay in µs
-40
magnitude in dB
magnitude in dB
-30
0.2
-70
0.15
-80
-8
0.1
-90
0.05
-100
102
202
302
402
502
602
702
frequency in MHz
802
902
1002
-10
1102
580
585
590
595
600
605
frequency in MHz
610
615
620
625
0
Construction and pin connection
(All dimensions in mm)
7
602
● E09
1
SQ 3,81 +0,2/-0,1
5
3
7
5
0,1
12
0%
0,6
%
d
3
1,78
2,54
1
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
Date code:
E
F
G
...
Year + week
2014
2015
2016
1,2 Max.
Date code
1
2
3
4
5
6
7
8
1,78
50 Ω Test circuit
L1
2
6
L2
SAW
1, 3, 4, 5, 7, 8
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS602.doc
Version 2.1
Vectron International
27.02.2014
Filter specification
TFS 602
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0.35 mm or g respectively, 1 octave per min, 10 cycles per
plane, 3 planes; DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 15 min. each / 100 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions, see page 4: "Air reflow temperature conditions"
This filter is RoHS compliant (2011/65/EU)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 12,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 5,50 ± 0,05
G(min)
: 0,75
P2
: 2,00 ± 0,05
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 4,30 ± 0,1
Bo
: 4,30 ± 0,1
Ct
: 9,2 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 12,4 +2/-0
W2(max) : 18,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS602.doc
Version 2.1
Vectron International
27.02.2014
Filter specification
TFS 602
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.
Filename: TFS602.doc
Vectron International
Version 2.1
Filter specification
27.02.2014
TFS 602
5/5
History
Version
Reason of Changes
Name
Date
1.0
Generation of development specification
Springfeldt
14.04.2004
1.1
adjust attenuation and loss to new customer requirements
Noack
26.11.2004
1.2
adjust attenuation and loss to new customer requirements
Martens
29.11.2004
1.3
Change of absolute attenuation
Strehl
20.01.2005
1.4
Change stability characteristics
add typical values and filter characteristic
generation of filter specification
Strehl
09.05.2005
1.5
Add IIP3 and change stability characteristics
Strehl
19.07.2006
2.0
Add OTR2
S. Channaa
28.06.2011
2.1
Typos corrected
Molke
27.02.2014
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.