1. Part No.
Eon:
SST:
EN29LV320AB-70TIP
SST39VF3201
2. Basic Features:
The following features are identical with each other.
2.7V – 3.6V Read/Program/Erase Voltage.
As fast as 70 ns read speed
Data# Polling and toggle bits
Erase-suspend / Erase resume
JEDEC standard compatible pin-out and command sets. (Program / Erase)
CMOS I/O compatibility
3. Identical:
Hardware reset pin (RESET#):
Hardware method to reset the device to reading array data
EN29LV320AB-70TIP: Yes
SST39VF3201: Yes
Hardware write protect pin (WP#):
Hardware method used for Write Protect function
EN29LV320AB-70TIP: Yes
SST39VF3201: Yes
This Application Note may be revised by subsequent versions
or modifications due to changes in technical specifications.
©2005 Eon Silicon Solution Inc. www.ession.com
Rev. A, Issue Date: 2009/ 04/30
Eon Silicon Solution Inc.
Page
3/5
4. Differences:
Word / Byte# configuration:
EN29LV320AB-70TIP: Yes (word or byte bus width selection)
SST39VF3201: No (only word type)
Ready/Busy# pin (RY/BY#):
Provides a hardware method of detecting program or erase cycle completion
EN29LV320AB-70TIP: Yes
SST39VF3201: No
Different sector type
EN29LV320AB-70TIP: Bottom boot sector, 63 X 64KB sectors
SST39VF3201: Uniform 4KB sector
Manufacture ID:
EN29LV320AB-70TIP
-
Manufacturer ID : 1CH / 7Fh
-
Device ID : 22F6h / 22F9h
This Application Note may be revised by subsequent versions
or modifications due to changes in technical specifications.
©2005 Eon Silicon Solution Inc. www.ession.com
Rev. A, Issue Date: 2009/ 04/30
Eon Silicon Solution Inc.
Page
4/5
SST39VF3201:
- Manufacturer ID : BFh
Device ID: 235Bh
Address input for command cycles:
EN29LV320AB-70TIP :
Using address input 555H and 2AAH for command cycles.
Address bits A11- A0 are input for 555H and 2AAH, address bits A12- A20 are don’t cares.
SST39VF3201:
Using address input 5555H and 2AAAH for command cycles.
Address bits A15- A0 are input for 5555H and 2AAAH, address bits A16~ A20 is are don’t
cares.
The address input in the command sequence for the SST39VF3201 can also be used
for the EN29LV320AB-70TIP without any change.
Temporary sector unprotect:
This mode allows users to use specific programmer equipment to do programming
function.
EN29LV320AB-70TIP : Yes
SST39VF3201: No
Different Vlko value:
This Application Note may be revised by subsequent versions
or modifications due to changes in technical specifications.
©2005 Eon Silicon Solution Inc. www.ession.com
Rev. A, Issue Date: 2009/ 04/30
Eon Silicon Solution Inc.
Page
5/5
When VCC is smaller Vlko, any write command is ignore. This is used to protect array
data during power on / down procedure.
EN29LV320AB-70TIP: 2.3V ~ 2.5V
SST39VF3201: <1.5V