ELECTRONICS TESTING CENTER, TAIWAN Address:NO. 8, LANE 29, WENMING RD., LESHAN VILLAGE, GUISHAN SHIANG, TAOYUAN COUNTY, 333, TAIWAN, R.O.C. TEL:886-3-328-0026 ext 291、298 FAX:886-3-327-6176 Testing Report Company:MINMAX TECHNOLOGY CO., LTD. Address:18, Sin-Sin Road, Tainan 702, TAIWAN For Office Use Application No.:ET94O-05-014-2 Reviewed by: Receive Date:11th May., 2005 Date Issued:20th May., 2005 Total Pages:2 This Page:1 Notes: 1.This report is based on single evaluation of the sample mentioned in testing results. It doesn’t imply an assessment of the whole production. 2.The content of this report is for references, but not for advertising publicity or other commercial purpose 3.The testing report shall not be reproduced except in full, without the written approval of ETC. Electronics Testing Center, Taiwan Manager Lab. Leader Notice For Customer: 1. MDL means Method Detection Limitation. 2. IDL means Instrument Detection Limitation. 3. N.D. means non-detected. 4. Each of samples was made for twice and calculated by mean value. 5. ppm means 10-6 of part per million; ppb means 10-9 of part per billion. Testing Result: please see the next page TO pursue excellence in service quality with a dedicated working attitude. Address:NO. 8, LANE 29, WENMING RD., LESHAN VILLAGE, GUISHAN SHIANG, TAOYUAN COUNTY, 333, TAIWAN, R.O.C. TEL:886-3-328-0026 ext 291、298 FAX:886-3-327-6176 ELECTRONICS TESTING CENTER, TAIWAN Testing Report Company:MINMAX TECHNOLOGY CO., LTD. Address:18, Sin-Sin Road, Tainan 702, TAIWAN For Office Use Application No.:ET94O-05-014-2 Reviewed by: Receive Date:11th May., 2005 Date Issued:20th May., 2005 Total Pages:2 This Page:2 Notes: 1.This report is based on single evaluation of the sample mentioned in testing results. It doesn’t imply an assessment of the whole production. 2.The content of this report is for references, but not for advertising publicity or other commercial purpose 3.The testing report shall not be reproduced except in full, without the written approval of ETC. NO.1 Application No. ET94O-05-014-2 Sample Description DC/DC Converter Style/Item No. MSIW1000 Series Testing Result (ppm, mg/ kg-each of Analytical Method & Substance Instruments sample) NO.1 MDL Pb ICP-OES US EPA 3051A & 6010B 365.0 0.6 Cd ICP-OES US EPA 3051A & 6010B N.D. 0.6 Hg ICP-OES US EPA 3051A & 6010B N.D. 1.0 Cr+6 UV-VIS US EPA 3060A & 7196A N.D. 0.5 PBBs GC-MS N.D. 1.0 N.D. 1.0 US EPA 3540C/3550B & 8082A/8081A/8270C US EPA 3540C/3550B & PBDEs GC-MS 8082A/8081A/8270C TO pursue excellence in service quality with a dedicated working attitude.