ELECTRONIC TRANSMITTER with FIELDBUS DATA SHEET Fieldbus is a standard digital communication protocol between field instruments and upper control system. This fieldbus standard enables interactive communication among the number of I&C manufactures simultaneously and also the usage by exchanging fieldbus instruments. FCX-AII Series Electronic Transmitters with FOUNDATION FIELDBUS and PROFIBUS is a fieldbus transmitters utilizing a unique micromachined capacitance silicon sensor with state-of -the-art microporcessor technology and converting the signal of silicon sensor to fieldbus protocol. This fieldbus transmitter can provide many merits of fieldbus as shown in the following “FEATURES”. FEATURES 1. Fuji Original IC “Frontier-1+ Fieldbus IC” “Frontier-1+” the original Fieldbus interface controller IC, developed by Fuji Electric based on IEC Fieldbus Physical Layer Specification, is installed in FCX-AII (Fieldbus version.). 2. Interoperability FCX-AII transmitter comply with the latest Foundation Fieldbus specification and PROFIBUS-PA specification and provide full interactive interoperability to other transmitters. In addition, FOUNDATION FIELDBUS FCX-AII transmitters are certified and registered by ITK4.0, the latest standard for Interoperability Testing. 3. Reduction of wiring cost The reduction of wiring cost of instrumentation is realizing due to multi-drop wiring of fieldbus instruments comparing to the current instruments. 4. High accuracy, high stability and high reliability High resolution data transmission with digital communication lead high accuracy, high stability and high reliability. 5. Abundant alarm functions and self-diagnosis Abundant alarm and maintenance function defined in Fieldbus specification in addition to process data can be well supported. The self-diagnosis including failure of pressure sensor, abnormal of temperature etc. are also provided. EDSX5-85d Date Jul. 31, 2007 Model Configuration Differential pressure/flow transmitter [model : FDC] (Standard version and Hydroseal diaphragm version) Pressure transmitter [type : FDG] (Standard version and Hydroseal diaphragm version) Reference page Reference page Common specifications 4 Common specifications 4 Individual specifications 5 Individual specifications 6 Code symbols 11 Code symbols 13 Outline diagram 31 Outline diagram 33 Level transmitter [model : FDE] Absolute pressure transmitter [model : FDA] Reference page Reference page Common specifications 4 Common specifications Individual specifications 7 Individual specifications 7 Code symbols 15 Code symbols 17 Outline diagram 35 Outline diagram 36 4 Remote seal type differential pressure/flow transmitter [model : FDD] Remote seal type pressure transmitter [model : FDB] Reference page 2 Reference page Common specifications 4 Common specifications Individual specifications 7 Individual specifications 8 Code symbols 19 Code symbols 21 Outline diagram 38 Outline diagram 39 4 Small frange type level transmitter [model : FDY] Reference page Common specifications 4 Individual specifications 8 Code symbols 23 Outline diagram 41 Small frange remote seal type differential pressure/flow transmitter [model : FDX] Reference page Common specifications 4 Individual specifications 9 Code symbols 25 Outline diagram 43 Small frange remote seal type pressure transmitter [model : FDW] Reference page Common specifications 4 Individual specifications 9 Code symbols 27 Outline diagram 46 3 SPECIFICATIONS (1) Common specifications Function and Performance Service: Output signal: Liquid, gas, and vapour Digital signal based on fieldbus FOUNDATION protocol or PROFIBUS-PA. Power supply: Transmitter operates on 9V to 32V DC at transmitter terminals. Quiescent draw current: 16± 2mA Standard: Foundation fieldbus Fieldbus Foundation specification(H1). (basic device, device type 113, AI function block) PROFIBUS PROFILE. Order No.3042 PROFIBUS-PA Humidity limit: 0 to 100% RH Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100MΩ at 500V DC. Structure and Material Electrical connections: G1/2, 1/2-14 NPT, Pg13.5, or M20 × 1.5 conduit, as specified. And 1 conduit or 2 conduits, as specified. Process connections: Model FDC, FDG, FDA FDE, FDY (LP side) PROFIBUS-PA Version 3.0 Transmission cycle (Macro cycle): Foundation fieldbus 250ms min. PROFIBUS-PA 250ms fix. Hazardous locations: Authorities ATEX Factory Mutual CSA JIS Flameproof Ex II2 GD -EExd IIC T5/T6 Class I II III Div. 1 Groups B thru. G Class I II III Div. 1 Groups C thru. G Ex do IIB+H2 T4 Note Ex iaIIC T4 FISCO (Approval pending) Zero/span adjustment: Zero and span are adjustable from the host system. Zero is also adjustable externally from the adjustment screw. Indication: None or 5-digit LCD meter, as specified. Burnout direction: Selectable from the host system. If self-diagnostic detect transmitter failure, the output will be driven to either “Output Hold”, “Output Overscale” or “Output Underscale” modes. Temperature limit: Ambient: – 40 to +85°C (–20 to +80°C for LCD indicator) (– 40 to +60°C for arrester option) (–10 to +60°C for fluorinated oil filled transmitters) (–10 to +85°C for silicone oil FDB, “H, S, K”) FDD (+20 to +85°C for silicone oil “J, T”) Ambient: – 15 to +65°C (–15 to +60°C for arrester FDW, option) (–10 to +60°C for fluorinated FDX, oil filled transmitter) FDY (–10 to +60°C for silicone oil “H, S”) For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified in each standard. 4 Process: See individual specifications Storage: – 40 to +90°C (FDW, FDX, FDY ··· – 40 to +70°C) Process connections 1/4-18NPT or Rc1/4 on 54mm centers, as specified. Meets DIN 19243. FDE, FDY (HP side) ANSI, DIN or JIS raised face frange. FDB, FDD, FDW, FDX See CODE SYMBOLS of each model (5th digit). Process-wetted parts material: See CODE SYMBOLS of each model (7th digit) Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy finished with polyester coating (standard), or 316 stainless steel (SCS14 per JIS G5121), as specified. Bolts and nuts: Cr-Mo alloy (standard), 304 stainless steel or 630 stainless steel, as specified. See CODE SYMBOLS of each model. Fill fluid: Silicone oil (standard) or fluorinated oil (Daifloil) Mounting bracket: 304 stainless steel Environmental protection: IEC IP67 and NEMA 6/6P Mounting: Model FDC, FDG, FDA Process connections On 60.5mm (JIS 50A) pope using mounting or direct wall mounting. FDE, FDY FDB, FDD, FDW, FDX Direct process mounting. Optional Specifications Varies with model or material. So refer to CODE SYMBOLS. Indicator: An optional 5-digit LCD meter with engineering unit is also available. Oxygen service: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Chlorine service: The fill fluid is fluorinated oil. Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. NACE specification: Metallic materials for all pressure boundary parts comply with NACE MR-01-75. ASTM B7M or L7M bolts and 2HM nuts (Class II) are available. Static pressure rating for code “3” (16 MPa) is degraded to 10MPa. Vacuum service: Special silicone oil and filling procedure are applied. See Fig. 1. Optional tag plate: An extra stainless steel tag with customer tag data is wired to the transmitter. Coating of cell: Cell’s surface is finished with epoxy/ polyurethane double coating. Specify if environment is extremely corrosive. Accessories Oval flanges: (Model FFP, refer to Data Sheet No. EDS6-10) Converts process connection to 1/2 -14 NPT or to Rc1/2; in carbon steel or in 316 stainless steel. Equalizing valves: (Model FFN, refer to Data Sheet No. EDS6-10) Available in Carbon steel or in 316 stainless steel and in pressure rating 16MPa or 42MPa. Over range limit: To maximum static pressure limit Process temperature and negative pressure tolerance limit: (For details, see Fig. 1) Filled oil 13th code Silicone oil (*1) Fluorinated oil Silicone oil Y, G, N W, A, D R CK CK (M4 screws) Do not connect. Field bus Negative pressure tolerance limit 2.7 kPa abs Atmospheric pressure 2.7 kPa abs Lower limit of static pressure (vacuum limit): Silicone oil filled sensor: See Fig. 1 Fluorinated oil filled sensor: 66kPa abs (500mmHg abs) at temperature below 60°C Accuracy rating: (including linearity, hysteresis, and repeatability) Reference conditions, silicone oil fill, 316SS isolating diaphragms. Max span above 32kPa model: For spans greater than 1/10 of URL: ± 0.07% of span For spans below 1/10 of URL: 0.1 × URL ± 0.02+0.05 % of span Span Max span 1kPa, 6kPa model: For spans greater than 1/10 of URL: ± 0.1% of span For spans below 1/10 of URL: 0.1 × URL ± 0.05+0.05 % of span Span Stability: ± 0.1% of upper range limit (URL) for 3 years Temperature effect: Effects per 28°C change between the limits of – 40°C and +85°C ( ) ( ) Range code (6th digit in Code symbols) Connection diagram Process temperatuer –40 to +120°C –20 to +80°C –15 to +120°C Zero shift Total effect “1”/1kPa max. span “2”/6kPa max. span ± 0.225% ± 0.25% “3”/32kPa max. span “5”/130kPa max. span “6”/500kPa max. span “8”/3000kPa max. span ± 0.0875% ± 0.1075% Static pressure effect: Static pressure code (5th digit in Code symbols) (2) Individual specifications Zero-based spans, reference conditions, silicone oil fill, SS316 isolating diaphragms, output in linear mode, digital trim values equal to the span setpoints and capillary length of 1.5m. Diffential Pressure / Flow Transmitter : FDC Static pressure, range limit: Type F DC F DC F DC F DC F DC F DC F DC F DC F DC F DC F DC F DC F DC Static pressure [MPa] 11 22 23 25 26 33 35 36 38 43 45 46 48 –0.1 to + 3.2 –0.1 to + 10 –0.1 to + 16 –0.1 to + 42 –0.1 to + 30 Range limit [kPa] +/– 1 +/– 6 +/– 32 +/– 130 +/– 500 +/– 32 +/– 130 +/– 500 +/– 3000 +/– 32 +/– 130 +/– 500 +/– 3000 Zero shift (% of URL) Span shift “1” /1kPa sensor “2” /6kPa sensor ±0.2% / 1MPa ±0.2% / 3.2MPa –0.2% /3.2MPa –0.2% /3.2MPa “2” “3” “4” ±0.05%/10MPa –0.2% /10MPa Overrange effect: Static pressure code (5th digit in Code symbols) Zero shift (% of URL) “1” / 1kPa sensor “2” / 6kPa sensor “2” “3” “4” ± 0.3% / 1MPa ± 0.1% / 3.2MPa ± 0.1% /10MPa ± 0.1% /16MPa ± 0.25% /42MPa Mounting position effect: Zero shift, less than 0.12kPa for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting Zero. Mass{weight}: Transmitter approximately 4.4kg without options. 5 Diffential Pressure / Flow Transmitter Hydroseal Diaphragm version: FDC Static pressure, range limit: Type F DC F DC Static pressure [MPa] Range limit [KPa] –0.1 to 16 –0.1 to 16 +/– 32 +/– 130 33 35 Over range limit: To maximum static pressure limit Process temperature and negative pressure tolerance limit: (For details, see Fig. 1) Filled oil 13th code Silicone oil Fluorinated oil Silicone oil Y, G, N W, A, D R Process temperatuer –20 to +120°C –20 to +80°C –15 to +120°C Negative pressure tolerance limit 2.7 kPa abs Atmospheric pressure 2.7 kPa abs Lower limit of static pressure (vacuum limit): Silicone oil filled sensor: See Fig. 1 Fluorinated oil filled sensor: 66kPa abs (500mmHg abs) at temperature below 60°C Accuracy rating: (including linearity, hysteresis, and repeatability) Reference conditions, silicone oil fill, 316SS isolating diaphragms. For spans greater than 1/10 of URL: ± 0.15% of span For spans below 1/10 of URL: 0.1×URL ± 0.1+0.05 % of span Span Stability: ± 0.15% of upper range limit (URL) for 3 years Temperature effect: Effects per 28°C change between the limits of – 40°C and +85°C ( ) Zero shift Total effect ± 0.175% ± 0.2% Static pressure effect: Zero shift (% of URL) Span shift ±0.15% /10MPa{100bar} Range code (6th digit in Code symbols) Zero shift (% of URL) “3” 1 % URL / 16MPa “5” 0.6 % URL / 16MPa Lower limit of static pressure (vacuum limit): Silicone oil filled sensor: See Fig. 1 Fluorinated oil filled sensor: 66kPa abs (500mmHg abs) at temperature below 60°C Accuracy rating: (including linearity, hysteresis, and repeatability) Reference conditions, silicone oil fill, 316SS isolating diaphragms. Max span below 10000kPa model: For spans greater than 1/10 of URL: ± 0.07% of span For spans below 1/10 of URL: 0.1 × URL ± 0.02+0.05 % of span Span Max span 50000kPa model: For spans greater than 1/10 of URL: ± 0.1% of span For spans below 1/10 of URL: 0.1 × URL ± 0.05+0.05 % of span Span Stability: ± 0.1% of upper range limit (URL) for 3 years Temperature effect: Effects per 28°C change between the limits of – 40°C and +85°C Zero shift: ± 0.0875% Total effect: ± 0.1075% Overrange effect: Zero shift; 0.2% of URL for any overrange to maximum limit Mounting position effect: Zero shift, less than 0.1kPa for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting Zero. Mass{weight}: Transmitter approximately 3.4kg without options. Type Range and overrange limit: Range limit [kPa] Lower limit Permissible negative pressure limit Upper limit 130 500 3000 10000 50000 Overrange limit [MPa] 1 1.5 9 15 75 Process temperature and negative pressure tolerance limit: (For details, see Fig. 1) 6 Y, G, N W, A, D R Negative pressure tolerance limit 2.7 kPa abs Atmospheric pressure 2.7 kPa abs ( ) ( ) Static pressure, range limit: Pressure Transmitter : FDG 01 02 03 04 05 Silicone oil Fluorinated oil Silicone oil Process temperatuer –40 to +100°C –20 to +80°C –15 to +100°C Pressure Transmitter Hydroseal Diaphragm version: FDG Mounting position effect: Zero shift, less than 0.12kPa for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting Zero. Mass{weight}: Transmitter approximately 4.4kg without options. F DG F DG F DG F DG F DG 13th code –0.2% /10MPa{100bar} Overrange effect: Type Filled oil Static pressure [MPa] FDG 07 –0.1 to 0.5 FDG 08 –0.1 to 3 FDG 09 –0.1 to 10 Range limit [kPa] Lower limit Upper limit Permissible negative pressure limit Over range limit [MPa] 500 1.5 3000 9 10000 15 Process temperature and negative pressure tolerance limit: (For details, see Fig. 1) Filled oil 13th code Silicone oil Fluorinated oil Y, G, N W, A, D Process temperatuer –20 to +100°C –20 to +80°C Negative pressure tolerance limit 2.7 kPa abs Atmospheric pressure Lower limit of static pressure (vacuum limit): Silicone oil filled sensor: See Fig. 1 Fluorinated oil filled sensor: 66kPa abs (500mmHg abs) at temperature below 60°C Accuracy rating: (including linearity, hysteresis, and repeatability) Reference conditions, silicone oil fill, 316SS isolating diaphragms. For spans greater than 1/10 of URL: ± 0.15% of span For spans below 1/10 of URL: 0.1 x URL ± 0.1+0.05 % of span Span ( ) ± 0.15% of upper range limit (URL) for 3 years Temperature effect: Effects per 28°C change between the limits of – 40°C and +85°C Zero shift: ± 0.2% Total effect: ± 0.225% Overrange effect: Zero shift; 0.4% of URL for any overrange to maximum limit Mounting position effect: Zero shift, less than 0.1kPa for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting Zero. Mass {weight}: Transmitter approximately 3.4kg without options. Stability: Absolute Pressure Transmitter : FDA Range and overrange limit: Type F DA F DA F DA F DA Range limit [kPa abs] 01 02 03 04 0 0 0 0 to to to to +16 +130 +500 +3000 Overrange limit [MPa] 0.5 0.5 1.5 9 Process temperature and negative pressure tolerance limit: Process temperature; –40 to +85°C Negative pressure; Depends on measuring range. Accuracy rating: (including linearity, hysteresis, and repeatability). Reference conditions, silicone oil fill, 316SS isolating diaphragms. (Standard) For spans greater than 1/10 of URL: ± 0.2% of span For spans below 1/10 of URL: 0.1 × URL ± 0.1+0.1 % of span Span (Option) (code: 21th digit H) (Not available for Max span 16kPa abs, 130kPa abs) For spans greater than 1/10 of URL: ± 0.1% of span For spans below 1/10 of URL: 0.1 × URL ± 0.05+0.05 % of span Span Stability: ± 0.2% of upper range limit (URL) for 3 years Temperature effect: Effect per 28°C change between the limits of – 40°C and +85°C Zero shift: ± 0.225% Total effect: ± 0.25% Overrange effect: Zero shift; ± 0.2% of URL for any overrange to maximum limit Mounting position effect: Zero shift, less than 0.1kPa for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting zero. Mass{weight}: Transmitter approximately 3.4kg without options. ( ( ) ) Level Transmitter : FDE F DE F DE F DE Static pressure 3 5 6 Up to flange rating Filled oil 13th code Fluorinated oil Silicone oil W, A, D H J Y, G S T K Process temperatuer –20 to +120°C –15 to +250°C 85 to +300°C –40 to +120°C –15 to +250°C 85 to +300°C –15 to +150°C Negative pressure tolerance limit Atmospheric pressure 2.7 kPa abs 0.13 kPa abs Low pressure side contact liquid temperature on transmitter of Code “H, J, S, T” is 120°C or lower. Low pressure side contact liquid temperature of Code “K” is 85°C or lower. Lower limit of static pressure (vacuum limit): Silicone oil filled sensor: See Fig. 1 Fluorinated oil filled sensor: 66kPa abs (500mmHg abs) at temperature below 60°C Accuracy rating: (including linearity, hysteresis, and repeatability) Reference conditions, silicone oil fill, 316SS isolating diaphragms. (Standard) For spans greater than 1/10 of URL: ± 0.2% of span For spans below 1/10 of URL: 0.1 × URL ± 0.1+0.1 % of span Span (Option) (Code: 21th digit H, K) For span greater than 1/10 of URL: 0.1% of span For span below 1/10 of URL: 0.1 × URL ± 0.05+0.05 % of span Span Stability: ± 0.2% of upper range limit (URL) for 3 years Temperature effect: Effects per 28°C change between the limits of – 40°C and + 85°C (Standard) Zero shift: ± 0.35% of URL Total effect: ± 0.5% of URL (Option) (Code: 21th digit J, K) Zero shift: ± 0.3% of URL Total effect: ± 0.4% of URL Static pressure effect: Zero shift: ± 0.2% of URL / 1MPa Span shift: – 0.2% of calibrated span / 1MPa Overrange effect: Zero shift; ± 0.1% of URL for flange rating pressure Mounting position effect: Zero shift, less than 0.3kPa for a 10° tilt in any plane. (No extension) No effect on span. This error can be corrected by adjusting zero. Mass{weight}: Transmitter approximately 13kg without options. ( ( ) ) Remote Seal Type Diffential Pressure / Flow Transmitter: FDD Static pressure, range limit: Type Static pressure, range limit: Type Over range limit: To maximum static pressure limit Process temperature and negative pressure tolerance limit: (For details, see Fig. 2, Fig. 3) Range limit [kPa] +/– 32 +/– 130 +/– 500 F DD F DD F DD Static pressure 3 5 6 Up to flange rating Range limit [kPa] +/– 32 +/– 130 +/– 500 7 Filled oil 13th code Fluorinated oil Silicone oil W, A, D H J Y, G S T K Process temperatuer –20 to +120°C –15 to +250°C +85 to +300°C –40 to +120°C –15 to +250°C +85 to +300°C –15 to +200°C Negative pressure tolerance limit Atmospheric pressure 2.7 kPa abs 0.13 kPa abs Accuracy rating: (including linearity, hysteresis, and repeatability) Reference conditions, silicone oil fill, 316SS isolating diaphragms. (Standard) For spans greater than 1/10 of URL: 0.2% of span For spans below 1/10 of URL: 0.1 × URL ± 0.1+0.1 % of span Span (Option) (Code; 21th digit H,K) For spans greater than 1/10 of URL: 0.1% of span For spans below 1/10 of URL: 0.1 × URL ± 0.05+0.05 % of span Span Stability: ± 0.2% of upper range limit (URL) for 3 years Temperature effect (*): Effects per 28°C change between the limits of – 40°C and +85°C (Standard) Zero shift: ± 0.35% of URL Total effect: ± 0.5% of URL (Option) (Code; 21th digit J,K) Zero shift: ± 0.3% of URL Total effect: ± 0.4% of URL ( ) ( ) Note: * Excluding effect by temperature difference between the seals. Static pressure effect: Zero shift; 0.2% of URL for flange rating pressure Span shift: – 0.2% of calibrated span for flange rating pressure Overrange effect: Zero shift; 0.1% of URL for flange rating pressure Mass {weight}: Transmitter approximately 15kg without options. Remote Seal Type Pressure Transmitter: FDB Range, and overrange limit: Type F DB F DB F DB F DB F DB Range limit [kPa] 1 2 3 4 5 –100 –100 –100 –100 –100 to to to to to +130 +500 +3000 +10000 +50000 Overrange limit [MPa] 1 1.5 9 15 75 Process temperature and negative pressure tolerance limit: (For details, see Fig. 2, Fig. 4) 8 Filled oil 13th code Fluorinated oil Silicone oil W, A, D H J Y, G S T K Process temperatuer –20 to +120°C –15 to +250°C 85 to +300°C –40 to +120°C –15 to +250°C 85 to +300°C –15 to +200°C Negative pressure tolerance limit Atmospheric pressure 2.7 kPa abs 0.13 kPa abs Accuracy rating: (including linearity, hysteresis, and repeatability) Reference conditions, silicone oil fill, 316SS isolating diaphragms. (Standard) For spans greater than 1/10 of URL: ± 0.2% of span For spans below 1/10 of URL: 0.1 × URL ± 0.1+0.1 % of span Span (Option) (Code; 21th digit H,K) Not available for Max span 50000kPa model. For spans greater than 1/10 of URL: ± 0.1% of span For spans below 1/10 of URL: 0.1 × URL ± 0.05+0.05 % of span Span ( ( ) ) ± 0.1% of upper range limit (URL) for 3 years Temperature effect: Effect per 28°C change between the limits of – 40°C and +85°C (Standard) Zero shift: ± 0.35% of URL Total effect: ± 0.5% of URL (Option) (Code; 21th digit J,K) Zero shift: ± 0.3% of URL Total effect: ± 0.4% of URL Overrange effect: Zero shift; 0.2% of URL for any overrange to maximum limit Mass {weight}: Transmitter approximately 10kg without options. Stability: Small Frange Level Transmitter : FDY Static pressure, range limit: Type Static pressure FDY 5 FDY 6 Over range limit: To maximum static pressure limit Process temperature and negative pressure tolerance limit: (For details, see Fig. 2, Fig. 4) Up to flange rating Range limit [kPa] +/– 130 +/– 500 Over range limit: To maximum static pressure limit Process temperature and negative pressure tolerance limit: (For details, see Fig. 2) Filled oil 13th code Process Negative pressure temperatuer tolerance limit Fluorinated oil W, A, D –20 to +80°C Atmospheric pressure Silicone oil H 0 to +250°C Y, G –40 to +120°C 2.7 kPa abs S 0 to +250°C Low pressure side contact liquid temperature on transmitter of Code “H, S” is 120°C or lower. Lower limit of static pressure (vacuum limit): Silicone oil filled sensor: See Fig. 1 Fluorinated oil filled sensor: 66kPa abs (500mmHg abs) at temperature below 60°C Accuracy rating: (including linearity, hysteresis, and repeatability) Reference conditions, silicone oil fill, 316SS isolating diaphragms. (Standard) For spans greater than 1/10 of URL: ± 0.25% of span For spans below 1/10 of URL: 0.1 x URL ± 0.17+0.08 % of span Span (Option) (Code: 21th digit H, K) For spans greater than 1/10 of URL: ± 0.1% of span For span below 1/10 of URL: 0.1 x URL ± 0.05+0.05 % of span Span ( ) ( ) ± 0.2% of upper range limit (URL) for 3 years Temperature effect: Effects per 28°C change between the limits of – 15°C and + 65°C Zero shift; ± 0.5% Total shift; ± 0.75% (Option) (Code: 21th digit J, K) Zero shift; ± 0.5% Total shift; ± 0.75% Stability: Where, URL: Maximum span (Upper Range Limit) Static pressure effect: Zero shift: ± 0.2% of URL/1MPa Span shift: –0.2% of calibrated span /1MPa Overrange effect:Zero shift; ± 0.1% of URL for flange rating pressure Mass{weight}: Transmitter approximately 13kg without options. Small Frange Remote Seal Type Differential Pressure Transmitter: FDX Static pressure, range limit: Type Static pressure FDX 5 FDX 6 } Up tp flange rating Range limit [kPa] +/– 130 +/– 500 Over range limit: To maximum static pressure limit Process temperature and negative pressure tolerance limit: (For details, see Fig. 2, Fig. 4) Filled oil 13th code Fluorinated oil Silicone oil W, A, D H Y, G S Process temperatuer –20 to +120°C 0 to +250°C –40 to +120°C 0 to +250°C Negative pressure tolerance limit Atmospheric pressure 2.7 kPa abs Accuracy rating: (including linearity, hysteresis, and repeatability) Reference conditions, silicone oil fill, 316SS isolating diaphragms. (Standard) For spans greater than 1/10 of URL: 0.25% of span For spans below 1/10 of URL: 0.1 x URL ± 0.17+0.08 % of span Span ( ) (Option) (Code; 21th digit H,K) For spans greater than 1/10 of URL: 0.1% of span For spans below 1/10 of URL: 0.1 x URL ± 0.05+0.05 % of span Span Stability: ± 0.2% of upper range limit (URL) for 3 years Temperature effect: Effects per 28°C change between the limits of – 15°C and +65°C Zero shift: ± 0.5% Total shift; ± 0.75% (option) (Code; 21th digit J,K) Zero shift: ±0.5 Total shift; ± 0.75% ( Where, ) Static pressure effect: Zero shift; 0.2% of URL/1MPa (10 bar) Span shift: – 0.2% of calibrated span / 1MPa Overrange effect: Zero shift; 0.1% of URL for flange nominal pressure Mass {weight}: Transmitter approximately 15kg without options. Small Frange Remote Seal Type Pressure Transmitter: FDW Range, and overrange limit: Type Range limit [kPa] Overrange limit [MPa] FDW 3 –100 to +3000 4.5 FDW 4 –100 to 10000 15 Process temperature and negative pressure tolerance limit: (For details, see Fig. 2) Filled oil 13th code Fluorinated oil Silicone oil W, A, D H Y, G S Process temperatuer –20 to +120°C 0 to +250°C –40 to +120°C 0 to +250°C Negative pressure tolerance limit Atmospheric pressure 2.7 kPa abs Accuracy rating: (including linearity, hysteresis, and repeatability) Reference conditions, silicone oil fill, SS316 isolating diaphragms. (Standard) For spans greater than 1/10 of URL: ± 0.25% of span For spans below 1/10 of URL: ± 0.17+0.08 0.1 x URL % of span Span (Option) (Code; 21th digit H) For spans greater than 1/10 of URL: ± 0.1% of span For spans below 1/10 of URL: ± 0.05+0.05 0.1 x URL % of span Span Stability: ± 0.2% of upper range limit (URL) for 3 years Temperature effect: Effect per 28°C change between the limits of – 15°C and +65°C Zero shift: ± 0.5% Total shift; ± 0.75% ( ) ( ) Where, URL: Maximum span (Upper Range Limit) Note : Above specifications are based on the conditions that flange and sensor unit are at the same temperature and in the same level. If temperature is different at flange, capillary or sensor unit, output variation may increase. Overrange effect: Zero shift; 0.2% of URL/(1.5 x URL) Mass {weight}: Transmitter approximately 10kg without options. URL: Maximum span (Upper Range Limit) Note : Above specifications are based on the conditions that flanges and sensor unit are at the same temperature and in the same level. If temperature is different at flanges, capillary or sensor unit, output variation may increase. 9 Silicone oil (Code:Y,G,N) Silicone oil (Code:R) [kPa abs] {mbar abs} [kPa abs] Sealing liquid:Silicone (Code K) 101 Operating area Operating pressure Operating pressure 101 {1010} 20 4 Operating arear Non-operating area 2.7 None-operating area –40 –15 0.13 {1.3} 60 85 120 –15 Process temperature[°C ] 100 Process temperature[°C ] Fig. 1 Relation between process temperature and operating pressure (pressure and differential pressure/flow transmitters) Fig. 3 Relation between process temperature and operating pressure (level transmitters) Filled fluid: Silicone oil (code Y, G) [kPa abs] Filled fluid: Silicone oil (code S) [kPa abs] Filled fluid: Silicone oil (code K) Filled fluid: Silicone oil (code T) Operating pressure Operating pressure 101 53.3 Operating area 13.3 2.7 60 85 120 200 230250 Process temperature Fig. 2 Relation between process temperature and operating pressure (remote seal type pressure, remote seal type differential pressure and level transmitters) 10 Operating area Nonoperating area 0.27 Non-operating area –40 –15 101 0.13 300 [°C] –15 100 Process temperature 200 [°C] Fig. 4 Relation between process temperature and operating pressure (remote seal type pressure, remote seal type differential pressure and level transmitters) CODE SYMBOLS Diffential pressure / flow transmitter : FDC 1 2 3 4 5 6 7 8 Digit 4 Note Description <Connection> Oval flange Conduit Process connection connection screw 7/16-20UNF (×1) G1/2 Rc1/4 7/16-20UNF 1/2-14NPT (×1) 1/4-18NPT Combination with 12th 1/4-18NPT digit code “C, E, P, Q” M10 (or M12)(*1) Pg 13.5 (×1) are not available. 1/4-18NPT M10 (or M12)(*1) M20×1.5 (×1) 7/16-20UNF 1/4-18NPT Pg 13.5 (×1) 7/16-20UNF (×2) G1/2 Rc1/4 7/16-20UNF 1/2-14NPT (×2) 1/4-18NPT 1/4-18NPT M10 (or M12)(*1) Pg 13.5 (×2) 1/4-18NPT M10 (or M12)(*1) M20×1.5 (×2) 7/16-20UNF 1/4-18NPT Pg 13.5 (×2) 5, 6, 7 <Span and materials> Static Wetted Span limit (*2) Process Diaphragm pressure cover cell body [MPa] [kPa] –0.1 to +3.2 0.1…1 –0.1 to+10 0.1…6 –0.1 to+16 0.32…32 1.3…130 5…500 30…3000 –0.1 to+42 0.32…32 1.3…130 5…500 –0.1 to+30 30…3000 –0.1 to+10 0.32…32 1.3…130 5…500 –0.1 to+16 3.2…32 13…130 316 stainless steel 316L stainless steel 316 stainless steel 316L stainless steel +Au coating 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel 316L stainless steel +Au coating 316 stainless steel Hast. C 316 stainless steel 316L stainless steel 316 stainless steel 316L stainless steel +Au coating 316 stainless steel Hast. C 316 stainless steel Monel 316 stainless steel Tantalum 316 stainless steel 316L stainless steel 316 stainless steel 316L stainless steel +Au coating 316 stainless steel Hast. C 316 stainless steel Monel 316 stainless steel Tantalum 316 stainless steel 316L stainless steel 316 stainless steel 316L stainless steel +Au coating 316 stainless steel Hast. C 316 stainless steel Monel 316 stainless steel Tantalum 316 stainless steel 316L stainless steel 316 stainless steel 316L stainless steel +Au coating 316 stainless steel 316L stainless steel 316 stainless steel 316L stainless steel +Au coating 316 stainless steel Hast. C 316 stainless steel Monel 316 stainless steel 316L stainless steel 316 stainless steel 316L stainless steel +Au coating 316 stainless steel Hast. C 316 stainless steel Monel 316 stainless steel 316L stainless steel 316 stainless steel 316L stainless steel +Au coating 316 stainless steel Hast. C 316 stainless steel Monel 316 stainless steel 316L stainless steel 316 stainless steel 316L stainless steel +Au coating Hast. C Hast. C lining Monel Monel lining Tantalum lining Tantalum Hast. C Hast. C lining Monel Monel lining Tantalum lining Tantalum Hast. C Hast. C lining Monel Monel lining Tantalum lining Tantalum 316 stainless steel 316L stainless steel (*3) 316 stainless steel 316L stainless steel (*3) Note 1 Note 1 Note 1 Note 1 FDC 4 9 10 11 12 13 14 15 Digit No. of code A B C D E S T V W X Note 2 316 stainless steel 316 stainless steel 11V 11J Hast. C lining 316 stainless steel 316 stainless steel 11H 22V 22J Hast. C lining 316 stainless steel 316 stainless steel 22H 33V 33J Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 33H 33M 33T 35V 35J Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 35H 35M 35T 36V 36J Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 36H 36M 36T 38V 38J 316 stainless steel 316 stainless steel 43V 43J Hast. C lining Monel lining 316 stainless steel 316 stainless steel 43H 43M 45V 45J Hast. C lining Monel lining 316 stainless steel 316 stainless steel 45H 45M 46V 46J Hast. C lining Monel lining 316 stainless steel 316 stainless steel 46H 46M 48V 48J Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel Note 3 23B 23L 23U 25B 25L 25U 26B 26L 26U 33C 316 stainless steel Note 3 35C 11 1 2 3 4 5 6 7 8 Digit 9 10 11 12 13 14 15 Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Description <Digital indicator, arrester and communication> Digital indicator Arrester Communication type None None Foundation Fieldbus None Yes Foundation Fieldbus Yes None Foundation Fieldbus Yes Yes Foundation Fieldbus Note FDC 9 10 11 12 13 R V T W None (for ordinary locations) A TIIS, Flameproof (Conduit seal) TIIS, Flameproof (Cable gland seal) FM, Flameproof (or explosionproof) CSA, Flameproof (or explosionproof) ATEX, Flameproof B C D E X Approval pending ATEX, Intrinsic safty (Entity) SAA, Flameproof (or explosionproof) Approval pending Approval pending K F ATEX, FISCO Approval pending Note 9 4 A C D F Note 4 Y B C E M N P Q Y W G A D N R A B Note 8 Note 5 Note 6 Note 7 A B C D E F The thread is M12, if 42MPa {420bar} static pressure is specified. 100: 1 turn down is possible, but should be used at the span greater than 1/40 of the maximum span for better performance. The diaphragm face is coated with gold and ceramic. Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”. Static pressure should be –0.1 to +10MPa{–1 to +100bar}. Available for 5th digit code “1”, “2”, “3”. In case of stainless steel bolt with 5th digit code “3”, static pressure should be –0.1 to +10MPa {–1 to + 100bar}. Note 7: (*7) Available for 5th digit code “3”, “4”. Note 8: (*8) In case of tropical use, select stainless bolts and nuts. Note 9: (*9) In case of 10th code is “4”(ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available. 12 (*1) (*2) (*3) (*4) (*5) (*6) Digit No. of code A E P S None None Profibus None Yes Profibus Yes None Profibus Yes Yes Profibus <Approvals for hazardous, for fieldbus> <Vent/ drain and mounting bracket> Vent/drain Mounting bracket Specify “A” or “C” for the 7th Standard None Standard Yes, stainless steel digit code “B”, “L”, or “U” Side None Side Yes, stainless steel <Options> Extra SS tag plate Stainless steel elec, housing Coating of cell None None None Yes None None None Yes None Yes Yes None (*4) None None Yes Yes None Yes None Yes Yes Yes Yes Yes <Special applications and fill fluid> Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code “V” only) Chlorine service Fluorinated oil (7th digit code “H”, “T”, “B”, “U”) NACE specification Silicone oil (Not available for 7th digit code “T”, “U” and 15th digit code “A”, “B”) Vacuum service Silicone oil for vacuum use (Not available for 7th digit code “C”) <Sensor O-ring / Gasket> Viton (O-ring) Teflon (gasket) <Bolt/nut> (*8) Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Cr-Mo alloy hexagon bolt/nut NACE bolt/nut (ASTM A193 B7M/A194 2HM) (*5) NACE bolt/nut (ASTM A320 L7M/A194 2HM) 304 stainless steel bolt/304 stainless steel nut (*6) 630 stainless steel bolt/304 stainless steel nut (*7) 14 15 4 Pressure transmitter : FDG 1 2 3 4 5 6 7 8 Digit 4 6, 7 <Connections> Oval flange Process screw connection 7/16-20UNF Rc1/4 1/4-18NPT 7/16-20UNF 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT 7/16-20UNF 7/16-20UNF Rc1/4 1/4-18NPT 7/16-20UNF 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT 7/16-20UNF <Span and materials> Span limit Process cover [kPa](*2) 316 stainless steel 1.3…130 316 stainless steel 5…500 30…3000 100…10000 500…50000 50…500 300…3000 1000…10000 9 Note Description 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Conduit connection G1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 G1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 (×1) (×1) (×1) (×1) (×1) (×2) (×2) (×2) (×2) (×2) Combination with 12th digit code Note 1 “C, E, P, Q” are Note 1 not available. Note 1 Note 1 F DG 0 9 10 11 12 13 4 Digit No. of code A B C D E S T V W X Diaphragm Wetted cell body 316L stainless steel 316L stainless steel +Au Coating Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel 316L stainless steel +Au Coating Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel 316L stainless steel +Au Coating Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel 316L stainless steel +Au Coating Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel 316L stainless steel 316L stainless steel 316L stainless steel 316 stainless steel 316 stainless steel 1V 1J Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 1H 1M 1T 1B 1L 1U 2V 2J Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 2H 2M 2T 2B 2L 2U 3V 3J Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 3H 3M 3T 3B 3L 3U 4V 4J Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 4H 4M 4T 4B 4L 4U 5V 7C 8C 9C Note 2 <Digital indicator, arrester and communication> Digital indicator Arrester Communication type None None Foundation Fieldbus None Yes Foundation Fieldbus Yes None Foundation Fieldbus Yes Yes Foundation Fieldbus A E P S None None Yes Yes R V T W None Yes None Yes 14 15 Profibus Profibus Profibus Profibus 13 1 2 3 4 5 6 7 8 Digit 10 11 12 13 14 15 Description <Approvals for hazardous, for fieldbus> F DG 0 9 10 11 12 13 A TIIS, Flameproof (Conduit seal) TIIS, Flameproof (Cable gland seal) FM, Flameproof (or explosionproof) CSA, Flameproof (or explosionproof) ATEX, Flameproof B C D E X Approval pending ATEX, Intrinsic safty (Entity) SAA, Flameproof (or explosionproof) Approval pending Approval pending K F ATEX, FISCO Approval pending Note5 4 <Vent/ drain and mounting bracket> Vent/drain Mounting bracket Standard None Specify “A”, or “C” for the 7th Standard Yes, stainless steel digit code “B”, “L”, or “U” Side None Side Yes, stainless steel <Options> Extra SS tag plate Stainless steel elec. housing Coating of cell None None None Yes None None None Yes None Note3 (*3) Yes Yes None None None Yes Yes None Yes None Yes Yes Yes Yes Yes <Special applications and fill fluid> Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code “V” only) Chlorine service Fluorinated oil (7th digit code “H”, “T”, “B”, “U”) NACE specification Silicone oil (Not available for 6th digit code “5”, 7th digit code “T”, “U”, 15th digit code “A”, “B”) Vacuum service Silicone oil for vacuum use(Not available for 7th digit code “C”) <Sensor O-ring / Gasket> Viton (O-ring) Teflon (gasket) <Bolt/nut> (*4) Note4 Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Cr-Mo alloy hexagon bolt/nut NACE bolt/nut (ASTM A193 B7M/A194 2HM) Not available for 6th digit NACE bolt/nut (ASTM A320 L7M/A194 2HM) code “5” 304 stainless steel bolt/304 stainless steel nut 630 stainless steel bolt/304 stainless steel nut Available for 6th digit code “5” 14 15 4 None (for ordinary locations) Note 1 : (*1) Note 2 : (*2) Note 3 : (*3) Note 4 : (*4) Note 5: (*5) 14 Note Digit No. of code A C D F Y B C E M N P Q Y W G A D N R A B A B C D E F For 50MPa {500bar} units, M12 is provided rather than M10. 100: 1 turn down is possible, but should be used at the span greater than 1/40 of the maximum span for better performance. Costomer tag number can be engraved on standartd stainless steel name plate. If extra tag plate is required, select “Yes”. In case of tropical use, select stainless bolts and nuts. In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available. Absolute pressure transmitter : FDA 1 2 3 4 5 6 7 8 Digit 4 6, 7 Description <Connections> Process connection Rc1/4 1/4-18NPT 1/4-18NPT 1/4-18NPT 1/4-18NPT Rc1/4 1/4-18NPT 1/4-18NPT 1/4-18NPT 1/4-18NPT <Span limit> Span limit [kPa abs](*1) 1.6…16 1.6…130 5…500 30…3000 9 10 11 12 Note Oval flange screw 7/16-20UNF 7/16-20UNF M10 M10 7/16-20UNF 7/16-20UNF 7/16-20UNF M10 M10 7/16-20UNF Conduit connection G1/2 1/2-14NPT Pg 13.5 M20×1.5 Pg 13.5 G1/2 1/2-14NPT Pg 13.5 M20×1.5 Pg 13.5 Process cover Diaphragm Wetted cell body 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316L stainless steel Hast. C Monel 316L stainless steel Hast. C Monel Tantalum 316L stainless steel Hast. C Monel Tantalum 316L stainless steel Hast. C Monel Tantalum 316 stainless steel Hast. C lining Monel lining 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel Hast. C lining Monel lining Tantalum lining (×1) (×1) (×1) (×1) (×1) (×2) (×2) (×2) (×2) (×2) FDA 0 9 10 11 12 13 4 14 15 21 Digit No. of code A B C D E S T V W X Combination with 12th digit code “C, E, P, Q” are not available. Note1 1V 1H 1M 2V 2H 2M 2T 3V 3H 3M 3T 4V 4H 4M 4T <Digital indicator, arrester and communication> Digital indicator Arrester Communication type None None Foundation Fieldbus None Yes Foundation Fieldbus Yes None Foundation Fieldbus Yes Yes Foundation Fieldbus A E P S None None Profibus None Yes Profibus Yes None Profibus Yes Yes Profibus <Approvals for hazardous, for fieldbus> R V T W None (for ordinary locations) A TIIS, Flameproof (Conduit seal) TIIS, Flameproof (Cable gland seal) FM, Flameproof (or explosionproof) CSA, Flameproof (or explosionproof) ATEX, Flameproof B C D E X Approval pending ATEX, Intrinsic safty (Entity) SAA, Flameproof (or explosionproof) Approval pending Approval pending K F ATEX, FISCO Approval pending Note4 4 <Vent/ drain and mounting bracket> Vent/drain Mounting bracket Standard None Standard Yes, stainless steel Side None Side Yes, stainless steel <Options> Extra SS tag plate Stainless steel elec. housing None None Yes None None Yes (*2) Yes Yes None None Yes None None Yes Yes Yes A C D F Coating of cell None None None None Yes Yes Yes Yes Note2 Y B C E M N P Q 15 1 2 3 4 5 6 7 8 Digit 13 14 15 21 Note 1: Note 2: Note 3: Note 4: 16 Description Note <Special applications and fill fluid> Treatment Fill fluid Standard Silicone oil Degreasing Silicone oil NACE specification Silicone oil (7th digit code “T” and 15th digit code “A”, “B” are not available) <Sensor O-ring> Viton Note 3 <Bolt/nut> (*3) Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Cr-Mo alloy hexagon bolt/nut NACE bolt/nut (ASTM A193 B7M/A194 2HM) NACE bolt/nut (ASTM A320 L7M/A194 2HM) 304 stainless steel bolt/304 stainless steel nut <Other options> High accuracy type (*1) (*2) (*3) (*4) FDA 0 9 10 11 12 13 14 15 21 4 Y G N A A B C D E H 100: 1 turn down is possible, but should be used at a span greater than 1/40 of the maximum span for better performance. Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”. In case of tropical use, select stainless bolts and nuts. In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available. Digit No. of code Level transmitter : FDE 1 2 3 4 5 6 7 8 Digit 4 5 6 7 9 Description <Connections> Process connection Rc1/4 1/4-18NPT 1/4-18NPT 1/4-18NPT 1/4-18NPT Rc1/4 1/4-18NPT 1/4-18NPT 1/4-18NPT 1/4-18NPT Oval flange screw 7/16-20UNF 7/16-20UNF M10 M10 7/16-20UNF 7/16-20UNF 7/16-20UNF M10 M10 7/16-20UNF Conduit connection (×1) G 1/2 1/2-14NPT (×1) Pg13.5 (×1) M20×1.5 (×1) Pg13.5 (×1) (×2) G 1/2 1/2-14NPT (×2) Pg13.5 (×2) M20×1.5 (×2) Pg13.5 (×2) Note Hastelloy-C lining 316 stainless steel Hastelloy-C Monel lining 316 stainless steel Monel Tantalum lining 316 stainless steel Tantalum Hastelloy-C lining Hastelloy-C lining Hastelloy-C Monel lining Monel Monel lining Tantalum lining Tantalum Tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel <Digital indicator, arrester and communication> Digital indicator Arrester Communication type None None Foundation Fieldbus None Yes Foundation Fieldbus Yes None Foundation Fieldbus Yes Yes Foundation Fieldbus None None Yes Yes None Yes None Yes Profibus Profibus Profibus Profibus 9 10 11 12 13 4 14 15 21 Digit No. of code A B C D E S T V W X Combination with 12th digit code “C, E, P, Q” are not available. <Mounting flange> Material Size and rating 304 stainless JIS 10K 80A steel JIS 10K 100A JIS 30K 80A JIS 30K 100A ANSI/JPI 150LB 3" ANSI/JPI 150LB 4" ANSI/JPI 300LB 3" ANSI/JPI 300LB 4" DIN PN40 DN80 DIN PN16 DN100 JIS 20K 80A ANSI/JPI 600LB 3" Carbon steel JIS 10K 80A JIS 10K 100A JIS 30K 80A JIS 30K 100A ANSI/JPI 150LB 3" ANSI/JPI 150LB 4" ANSI/JPI 300LB 3" ANSI/JPI 300LB 4" DIN PN40 DN80 DIN PN16 DN100 316 stainless JIS 10K 80A steel ANSI/JPI 150LB 3B ANSI/JPI 150LB 4B ANSI/JPI 300LB 3B ANSI/JPI 300LB 4B ANSI/JPI 600LB 3B <Span limit (*1) [kPa] > 0.32 32 1.3 130 5 500 <Material> LP side Wetted sensor Diaphragm Process cover body 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel FDE Note 1 0 1 2 3 4 5 6 7 8 9 M R A B C D E F G H J K S T U V W X 3 5 6 HP side Diaphragm and flange face 316 stainless steel Hastelloy-C Monel Tantalum Diaphragm: 316L stainless steel +Au coating Flange face: 316 stainless steel Hastelloy-C Monel Tantalum Hastelloy-C Monel Tantalum Note 3 Titanium Note 2, 3 Zirconium V C D E J H M T B L U P R A E P S R V T W 17 1 2 3 4 5 6 7 8 Digit 10 11 12 13 14 15 21 Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7: 18 Description <Approvals for hazardous, for fieldbus> Note FDE 9 10 11 12 13 None (for ordinary locations) A TIIS, Flameproof (Conduit seal) TIIS, Flameproof (Cable gland seal) FM, Flameproof (or explosionproof) CSA, Flameproof (or explosionproof) ATEX, Flameproof B C D E X Approval pending ATEX, Intrinsic safty (Entity) SAA, Flameproof (or explosionproof) Approval pending Approval pending K F ATEX, FISCO Approval pending Note7 4 <Diaphragm extension [mm]> Extension [mm] Applicable material code 0 Any 50 100 (7th digit code “V“ only) 150 200 50 100 (7th digit code “C“, “H“, “B“, only) 150 200 <Options> Extra SS tag plate Stainless steel elec. housing Coating of cell None None None Yes None None None Yes None Note 4 Yes (* 4) Yes None None None Yes Yes None Yes None Yes Yes Yes Yes Yes <Special applications and fill fluid> Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Fluorinated oil (7th digit code “V“ only) Oxygen service Fluorinated oil (7th digit code “C”, “E”, “H”, “T”, “B”, “U”) Chlorine service 7th digit code “V”, “C”, “H”, “B” High temp. 250°C High temp. 300°C (* 5) Note 5 High temp. and vacuum (250°C) 7th digit code “V” High temp. and vacuum (300°C) High temp. and high vacuum Silicone oil <O-ring, gasket and Teflon membrane> O-ring /Gasket Teflon membrane Viton (O-ring) None Teflon (gasket) None Viton (O-ring) Yes (5th digit code “0”, “2”, “4”, “6”, “8”, “A”, Teflon (gasket) Yes “C”, “E”, “G”, “J”, “M”, “R”, “S”, “T”, “V”, “X”, and 11th digit code “Y” are available. 13th digit code “H, J, S, T, K” are not available.) Note 6 <Bolt/nut> (* 6) Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Cr-Mo alloy hexagon bolt/nut 304 stainless steel bolt /304 stainless steel nut <Other options> High accuracy type Low temperature effect type H+J (*1) (*2) (*3) (*4) (*5) (*6) (*7) 14 15 21 4 Y A B C D E F G H Y B C E M N P Q Y W G A D H J S T K A B C D A B E H J K 100: 1 turn down is possible, but should be used at a span greater than 1/40 of the maximum span for better performance. Material Code R; 6th digit code “6” is not available. 5th digit code “0, 2, 4, 6, 8, A, C, E, G, J, P, M, R, S, T, V, X” are available. Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes” Treatment; None In case of tropical use, select stainless bolts and nuts. In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available. Digit No. of code Remote seal type differential pressure transmitter : FDD 1 2 3 4 5 6 7 8 Digit 4 5 6 7 9 Description <Conduit connection> (×1) G 1/2 1/2-14NPT (×1) Combination with 12th digit code “C, E, P, Q” are not available. Pg13.5 (×1) M20 × 1.5 (×1) (×2) G 1/2 1/2-14NPT (×2) Pg13.5 (×2) M20 × 1.5 (×2) <Flange> Mounting flange Flange size and rating 304 stainless JIS 10K 80A steel JIS 10K 100A JIS 30K 80A JIS 30K 100A ANSI/JPI 150LB 3" ANSI/JPI 150LB 4" ANSI/JPI 300LB 3" ANSI/JPI 300LB 4" DIN PN16/40 DN80 DIN PN16 DN100 JIS 20K 80A ANSI/JPI 600LB 3" Carbon steel JIS 10K 80A JIS 10K 100A JIS 30K 80A JIS 30K 100A ANSI/JPI 150LB 3" ANSI/JPI 150LB 4" ANSI/JPI 300LB 3" ANSI/JPI 300LB 4" DIN PN16/40 DN80 DIN PN16 DN100 316 stainless JIS 10K 80A steel ANSI/JPI 150LB 3" ANSI/JPI 150LB 4" ANSI/JPI 300LB 3" ANSI/JPI 300LB 4" ANSI/JPI 600LB 3" None 3 inch wafer (wafer type) 4 inch wafer <Span limit (*1) [kPa]> 0.32.... 32 1.3...... 130 5......... 500 <Material/diaphragm extension> Diaphragm Flange face Diaph. extension [mm] 316L stainless 316 stainless 0 steel steel 50 100 (*2) 150 200 Hastelloy-C Hastelloy-C 0 50 100 150 200 316L stainless 316 stainless 0 +Au coating steel Monel Monel 0 Tantalum Tantalum 0 Titanium Titanium 0 (*3) Zirconium Zirconium 0 <Digital indicator, arrester and communication> Digital indicator Arrester Communication type None None Foundation Fieldbus None Yes Foundation Fieldbus Yes None Foundation Fieldbus Yes Yes Foundation Fieldbus None None Yes Yes None Yes None Yes Profibus Profibus Profibus Profibus Note FDD 9 10 11 12 13 4 14 15 0 21 Digit No. of code A B C D S T V W 0 1 2 3 4 5 6 7 8 9 M R A B C D E F G H J K S T U V W X P Q Note 1 3 5 6 Note 2 Note 3 V A B C D H F G K L J M T P R A E P S R V T W 19 1 2 3 4 5 6 7 8 Digit 10 11 12 13 14 21 Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7: Note 8: 20 Description <Approvals for hazardous, for fieldbus> Note FDD 9 10 11 12 13 4 21 0 None (for ordinary locations) A TIIS, Flameproof (Conduit seal) TIIS, Flameproof (Cable gland seal) FM, Flameproof (or explosionproof) CSA, Flameproof (or explosionproof) ATEX, Flameproof B C D E X Approval pending 14 15 ATEX, Intrinsic safty (Entity) SAA, Flameproof (or explosionproof) Approval pending Approval pending K F ATEX, FISCO Approval pending Note 8 4 <Capillary and mounting bracket> Capillary Mounting bracket armor of capilary D Note 4 1.5 m 304 Stainless steel PVC (*4) E Note 4 3 304 Stainless steel PVC (*4) L Note 4 5 304 Stainless steel PVC (*4) F Note 4 6 304 Stainless steel PVC (*4) M Note 4 7 304 Stainless steel PVC (*4) N Note 4 8 304 Stainless steel PVC (*4) P Note 4 10 304 Stainless steel PVC (*4) Q Note 5 1.5 304 Stainless steel Stainless steel (*5) R Note 5 3 304 Stainless steel Stainless steel (*5) S Note 5 5 304 Stainless steel Stainless steel (*5) T Note 5 6 304 Stainless steel Stainless steel (*5) V Note 4 7 304 Stainless steel Stainless steel (*4) W Note 4 8 304 Stainless steel Stainless steel (*4) X Note 4 10 304 Stainless steel Stainless steel (*4) <Options> Extra SS tag plate Stainless steel elec. housing Coating of cell None None None Y Yes None None B None Yes None C (*6) Note 6 Yes Yes None E None None Yes M Yes None Yes N None Yes Yes P Yes Yes Yes Q <Special applications and fill fluid> Treatment Fill fluid Y Standard Silicone oil W Standard Fluorinated oil G Degreasing Silicone oil A Oxygen service Fluorinated oil (7th digit code “V”, “A”, “B”, “C” and “D”) D Chlorine service Fluorinated oil (7th digit code “H”, “F”, “G”, “K”, “L” and “T”) H High temp. 250°C Silicone oil J High temp. 300°C Silicone oil (*7) Note 7 High temp. and vacuum (250°C) Silicone oil 7th digit code “V”, “A”, “B”, S High temp. and vacuum (300°C) Silicone oil “C”, and “D” T High temp. and high vacuum Silicone oil K <Teflon membrane> None Y Yes (Available for 5th digit code “0”, “2”, “4”, “6”, “8”, “A”, “C”, “E”, “G”, “J”, “P”, C “M”, “R”, “S”, “T”, “V”, “X” and 7th digit code “V”, “H”, “M”, “T”, “P”, “R”. Not available for the 13th digit code “H”, “J”, “S”, “T”, “K”.) <Other options> H High accuracy type J Low temperature effect type K H+J (*1) 100: 1 turn down is possible, but should be used at a span greater than 1/40 of the maximum span for better performance. (*2) In case of 13th digit code “S”, “T”, “K” and 5th digit code “1”, “3”, “5”, “7”, “B”, “D”, “F”, “H”, “Q”, “K”, “U”, “W” are available. (*3) Available for 6th digit code “2, 3” and 5th digit code “0, 2, 4, 6, 8, A, C, E, G, J, P, M, R, S, T, W”. (*4) Available for 13th digit code “Y, W, G, A, D”. Inquire about in case of 13th other code. (*5) Available for 13th digit code “Y”, “W”, “G”, “A”, “D”, “H”, “J”, “S”, “T”, “K”. (*6) Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”. (*7) Treatment; Standard (*8) In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available. Digit No. of code Remote seal type pressure transmitter : FDB 1 2 3 4 5 6 7 8 Digit 4 5 6 7 9 Description <Conduit connection> G1/2 (×1) 1/2-14NPT (×1) Combination with 12th digit code Pg13.5 (×1) “C, E, P, Q” are not available. M20 × 1.5 (×1) (×2) G1/2 1/2-14NPT (×2) Pg13.5 (×2) M20 × 1.5 (×2) <Flanges> Mounting flange Flange size and rating Ranges 1 2 3 4 5 304 stainless * * * JIS 10K 80A steel * * * JIS 10K 100A * * * ANSI/JPI 150LB “3” * * * ANSI/JPI 150LB “4” * * * DIN PN16/40 DN80 * * * DIN PN16 DN100 * * * JIS 20K 80A * * * JIS 30K 80A * * * ANSI/JPI 300LB 3B * * * ANSI/JPI 600LB 3B Carbon steel * * * JIS 10K 80A * * * JIS 10K 100A * * * ANSI/JPI 150LB “3” * * * ANSI/JPI 150LB “4” * * * DIN PN16/40 DN80 * * * DIN PN16 DN100 * * Screw type, JIS/ISO G1 316 stainless * * * ANSI/JPI 150LB 3B steel * * * ANSI/JPI 150LB 4B * * * ANSI/JPI 300LB 3B * * * ANSI/JPI 300LB 4B * * * ANSI/JPI 600LB 3B None * * * 3 inch wafer (wafer type) * * * 4 inch wafer <Span limit (*2) [kPa]> 1.3…130 5…500 30…3000 100…10000 Available only with material code “V” 500…50000 <Material/diaphragm extension> Diaphragm Flange face Diaph. extension [mm] 316L stainless 316 stainless 0 steel steel 50 100 (*3) 150 200 Hastelloy-C Hastelloy-C 0 50 100 150 200 316L stainless 316 stainless 0 +Au coating steel Monel Monel 0 Tantalum Tantalum 0 Titanium Titanium 0 (*4) Zirconium Zirconium 0 <Digital indicator, arrester and communication> Digital indicator Arrester Communication type None None Foundation Fieldbus None Yes Foundation Fieldbus Yes None Foundation Fieldbus Yes Yes Foundation Fieldbus None None Yes Yes None Yes None Yes Profibus Profibus Profibus Profibus Note FDB 9 10 11 12 13 14 15 4 21 Digit No. of code A B C D S T V W 0 1 3 4 6 7 9 M S T A B D E G H K V W X Y U P Q Note 2 1 2 3 4 5 Note 1 Note 3 Note 4 V (*1) A B C D H F G K L J M T P R A E P S R V T W 21 1 2 3 4 5 6 7 8 Digit 10 Description <Approvals for hazardous, for fieldbus> Note FDB 9 10 11 12 13 14 15 None (for ordinary locations) A TIIS, Flameproof (Conduit seal) TIIS, Flameproof (Cable gland seal) FM, Flameproof (or explosionproof) CSA, Flameproof (or explosionproof) ATEX, Flameproof B C D E X ATEX, Intrinsic safty (Entity) SAA, Flameproof (or explosionproof) ATEX, FISCO Approval pending 21 4 Approval pending Approval pending K F Approval pending 4 Note 10 11 12 13 14 15 21 <Capillary and mounting bracket> Capillary Mounting bracket Armor of capillary 1.5 m 304 Stainless steel PVC (*5) 3 304 Stainless steel PVC (*5) 5 304 Stainless steel PVC (*5) 6 304 Stainless steel PVC (*5) 7 304 Stainless steel PVC (*5) 8 304 Stainless steel PVC (*5) 10 304 Stainless steel PVC (*5) 1.5 304 Stainless steel Stainless steel (*6) 3 304 Stainless steel Stainless steel (*6) 5 304 Stainless steel Stainless steel (*6) 6 304 Stainless steel Stainless steel (*6) 7 304 Stainless steel Stainless steel (*5) 8 304 Stainless steel Stainless steel (*5) 10 304 Stainless steel Stainless steel (*5) <Options> Extra SS tag plate Stainless steel elec. housing Coating of cell None None None Yes None None None Yes None (*7) Yes Yes None None None Yes Yes None Yes None Yes Yes Yes Yes Yes <Special applications and fill fluid> Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code “V”, “A”, “B”, “C” and “D”) Chlorine service Fluorinated oil (7th digit code “H”, “F”, “G”, “K”, “L” and “T”) High temp. 250°C Silicone oil •Available for 6th digit code “1”, “2” or (* 8) High temp. 300°C Silicone oil “3”. In case of 13th code “S”, “T”, “K”, High temp. and vacuum (250°C) Silicone oil available for 6th digit code “2”, “3” only. High temp. and vacuum (300°C) Silicone oil •Available for 7th digit code “V”, “A”, High temp. and high vacuum Silicone oil “B”, “C” or “D”. Note 5 Note 5 Note 5 Note 5 Note 5 Note 5 Note 5 Note 6 Note 6 Note 6 Note 6 Note 5 Note 5 Note 5 Note 7 Note 8 <Teflon membrane> None Yes (Available for the 5th digit code “0”, “2”, “3”, “5”, “6”, “8”, “A”, “C”, “D”, “F”, “G”, “J”, “P”, “R” and 7th digit code “V”, “H”, “M”, “T”, “P”, “R”. Not available for the 13th digit code “H”, “J”, “S”, “T”, “K”.) Note 9 <Bolt/nut> (*9) None (6th digit code “1”, “2”, “3”) Cr-Mo alloy hexagon socket head cap screw/carbon steel nut (6th digit code Cr-Mo alloy hexagon bolt/carbon steel unit “4”, “5”) 304 stainless steel/304 stainless steel (6th digit code “4”) 630 stainless steel/304 stainless steel (6th digit code "5") <Other options> High accuracy type Low temperature effect type H+J D E L F M N P Q R S T V W X Y B C E M N P Q Y W G A D H J S T K Y C Y A B E F H J K Note 1: (*1) If range 4 or 5 is selected, specify material “V” in any cases. Note 2: (*2) 100: 1 turn down is possible, but should be used at a span greater than 1/40 of the maximum span for better performance. Note 3: (*3) Available for 13th digit code “S”, “T”, “K” and 5th digit code “1“,“4“,“7“,“B“,“E“,“H“,“Q“,“T“,“W“,“Y“. Note 4: (*4) Available for 6th digit code "2",“3“ and 5th digit “0“,“3“,“6“,“9“,“A“,“D“,“G“,“P“, “M“,“S“,“T“,“U“,“V“,“X“. Note 5: (*5) Available for 13th digit code “Y, W, G, A, D”. Inquire about in case of 13th other code. Note 6: (*6) Available for 13th digit code “Y”, “W”, “G”, “A”, “D”, “H”, “J”, “S”, “T”, “K”. Note 7: (*7) Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”. Note 8: (*8) Treatment; Standard Note 9: (*9) In case of tropical use, select stainless bolts and nuts. Note 10:(*10) In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available. 22 Digit No. of code Small frange type level transmitter : FDY 1 2 3 4 5 6 7 8 Digit 4 5 6 7 Description <Connections> Conduit Oval flange Process connection screw connection 7/16-20UNF (×1) G 1/2 Rc1/4 1/4-18NPT 7/16-20UNF 1/2-14NPT (×1) 1/4-18NPT M10 (or M12) Pg13.5 (×1) 1/4-18NPT M10 (or M12) M20×1.5 (×1) 1/4-18NPT 7/16-20UNF Pg13.5 (×1) 7/16-20UNF (×2) Rc1/4 G 1/2 1/4-18NPT 7/16-20UNF 1/2-14NPT (×2) 1/4-18NPT M10 (or M12) Pg13.5 (×2) 1/4-18NPT M10 (or M12) M20×1.5 (×2) 1/4-18NPT 7/16-20UNF Pg13.5 (×2) <Mounting flange> Material Size and rating 304 stainless JIS 10K 40A steel JIS 10K 50A JIS 20K 40A JIS 20K 50A JIS 30K 40A JIS 30K 50A ANSI/JPI 150LB 11/2" ANSI/JPI 150LB 2" ANSI/JPI 300LB 11/2" ANSI/JPI 300LB 2" Carbon steel JIS 10K 40A JIS 10K 50A JIS 20K 40A JIS 20K 50A JIS 30K 40A JIS 30K 50A ANSI/JPI 150LB 11/2" ANSI/JPI 150LB 2" ANSI/JPI 300LB 11/2" ANSI/JPI 300LB 2" <Span limit [kPa]> 3 130 12.5 500 <Material> LP side Diaphragm Wetted sensor Process cover body 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Note 9 Flange face: 316 stainless steel Hastelloy-C lining Hastelloy-C 316 stainless steel Hastelloy-C Monel lining Monel 316 stainless steel Monel Tantalum lining Tantalum 316 stainless steel Tantalum Hastelloy-C lining Hastelloy-C Hastelloy-C lining Hastelloy-C Monel Monel lining Monel Monel lining Tantalum Tantalum lining Tantalum Tantalum lining <Digital indicator, arrester and communication> Digital indicator Arrester Communication type None None Foundation Fieldbus None Yes Foundation Fieldbus Yes None Foundation Fieldbus Yes Yes Foundation Fieldbus None None Yes Yes None Yes None Yes Profibus Profibus Profibus Profibus 9 10 11 12 13 4 14 15 21 Digit No. of code A B C D E S T V W X Combination with 12th digit code “C, E, P, Q” are not available. HP side Diaphragm & flange face 316 stainless steel Diaphragm: 316L stainless steel +Au coating 316 stainless steel 316 stainless steel 316 stainless steel Hastelloy-C 316 stainless steel 316 stainless steel 316 stainless steel Monel 316 stainless steel 316 stainless steel 316 stainless steel Tantalum FDY 0 1 2 3 4 5 A B C D G H J K L M Q R S T Note1 5 6 V J C D E H M T B L U A E P S R V T W 23 1 2 3 4 5 6 7 8 Digit 10 11 12 13 14 15 21 Description <Approvals for hazardous, for fieldbus> Note FDY 9 10 11 12 13 None (for ordinary locations) A TIIS, Flameproof (Conduit seal) TIIS, Flameproof (Cable gland seal) FM, Flameproof (or explosionproof) CSA, Flameproof (or explosionproof) ATEX, Flameproof B C D E X Approval pending ATEX, Intrinsic safty (Entity) SAA, Flameproof (or explosionproof) Approval pending Approval pending K F ATEX, FISCO Approval pending Note 4 4 <Diaphragm extension [mm]> Extension [mm] Applicable material code 0 Any 50 100 (7th digit code “V” only, 11/2 in. flange is not applicable) 150 200 <Options> Extra SS tag plate Stainless steel elec. housing Coating of cell None None None Yes None None None Yes None Yes (*2) Yes None Note 2 None None Yes Yes None Yes None Yes Yes Yes Yes Yes <Special applications and fill fluid> Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code “V” only) Chlorine service Fluorinated oil (7th digit code “C”, “E”, “H”, “T”, “B”, “U”) High temp. 250°C Silicone oil (7th digit code “V” only) High temp. and vacuum (250°C) Silicone oil (7th digit code “V” only) <O-ring / Gasket and Teflon membrane> O-ring / Gasket Teflon membrane Viton (O-ring) None Teflon (gasket) None Viton (O-ring) Yes (11th digit code “Y” only) Teflon (gasket) Yes (13th digit code “H”, “S” are not available.) <Bolt/nut> (*3) Note 3 Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Cr-Mo alloy hexagon bolt/nut 304 stainless steel bolt / 304 stainless steel nut <Other options> High accuracy type Low temperature effect type H+J 14 15 21 4 Y A B C D Y B C E M N P Q Y W G A D H S A B C D A B E H J K Note 1: (*1) 100: 1 turn down is possible for model FDY, but should be used at a span greater than 1/40 of the maximum span for better performance. Note 2: (*2) Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”. Note 3: (*3) In case of tropical use, select stainless bolts and nuts. Note 4: (*4) In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available. 24 Digit No. of code Small frange remote seal type differential pressure transmitter : FDX 1 2 3 4 5 6 7 8 Digit 4 5 6 7 9 10 Description <Conduit connections> (×1) G 1/2 1/2 - 14NPT (×1) Combination with 12th digit code Pg13.5 (×1) “C, E, P, Q” are not available. M20 × 1.5 (×1) (×2) G 1/2 1/2 - 14NPT (×2) Pg13.5 (×2) M20 × 1.5 (×2) <Flange> Material Size and rating 304 stainless JIS 10K 40A steel JIS 10K 50A JIS 20K 40A JIS 20K 50A JIS 30K 40A JIS 30K 50A ANSI/JPI 150LB 1 1/2" ANSI/JPI 150LB 2" ANSI/JPI 300LB 1 1/2" ANSI/JPI 300LB 2" Carbon steel JIS 10K 40A JIS 10K 50A JIS 20K 40A JIS 20K 50A JIS 30K 40A JIS 30K 50A ANSI/JPI 150LB 1 1/2" ANSI/JPI 150LB 2" ANSI/JPI 300LB 1 1/2" ANSI/JPI 300LB 2" None 40A, 1 1/2B (Wafer type) 50A, 2B Direct mounting adapter connection (* 1) <Span limit [kPa]> 3........130 12.5...500 <Material/diapharagm extension> Flange face Diaphragm extension(mm) Diaphragm 0 316L stainless steel 316 stainless steel 50 100 (*2) 150 200 0 316L stainless steel +Au coating Hastelloy-C 0 Hastelloy-C Monel 0 Monel Tantalum 0 Tantalum <Digital indicator, arrester and communication> Digital indicator Arrester Communication type None None Foundation Fieldbus None Yes Foundation Fieldbus Yes None Foundation Fieldbus Yes Yes Foundation Fieldbus Note FDX 9 10 11 12 13 4 Note 1 0 1 2 3 4 5 A B C D G H J K L M Q R S T W X Y 5 6 Note 2 V A B C D J H M T A E P S R V T W None (for ordinary locations) A TIIS, Flameproof (Conduit seal) TIIS, Flameproof (Cable gland seal) FM, Flameproof (or explosionproof) CSA, Flameproof (or explosionproof) ATEX, Flameproof B C D E X ATEX, FISCO Digit No. of code A B C D S T V W None None Profibus None Yes Profibus Yes None Profibus Yes Yes Profibus <Approvals for hazardous, for fieldbus> ATEX, Intrinsic safty (Entity) SAA, Flameproof (or explosionproof) 14 15 16 17 18 19 20 21 Approval pending Approval pending Approval pending K F Approval pending 4 Note 5 25 1 2 3 4 5 6 7 8 Digit 11 12 13 14 Description <Capillary and mounting bracket> mounting bracket Capillary armor of capillary Stainless steel 1.5m PVC 3m 5m 1.5m Stainless steel 3m 5m Note (*4) FDX Note 2: (*2) Note 3: (*3) Note 4: (*4) Note 5: (*5) 14 15 16 17 18 19 20 21 Digit No. of code D E L Q R S Note4 <Options> Stainless steel elec. housing Coating of cell Extra tag tag plate None None None Yes None None Note3 None Yes None (*3) Yes Yes None None None Yes Yes None Yes None Yes Yes Yes Yes Yes <Treatment/Fill fluid> Treatment Fill fluid Standard Silicone oil (for general use) Fluorinated oil Standard Degreasing Silicone oil Fluorinated oil (7th digit code “V”, “A”, “B”, “C” and “D”) Oxygen service Chlorine service Fluorinated oil (7th digit code “H” and “T”) High temp. 250°C Silicone oil (7th digit code “V”, “A”, “B”, “C” and “D”) High temp. and vacuum (250°C) Silicone oil <Teflon membrane> None Yes (Available for 7th digit code “V”, “H”, “M”, “T”. Not available for 5th digit code “Y” and 13th digit code “H”, “S”.) Note 1: (*1) 9 10 11 12 13 4 Y B C E M N P Q Y W G A D H S Y C Direct mounting adapter type is specified at 16th to 20th digit. Direct mounting adapter is available only for 7th digit code “V”. Diaphragm extension is available only for 2" (50A) flanges. Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”. Availalde for 13th digit code “Y, W, G, A, D”. Inquire about in case of 13th other code. In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available. Specifications of Direct Mounting Adapter {for 15, 20A (1/2, 3/4”) connection} and others Note 1. When odering the instrument with direct mounting adapter, specify “Y” in the 5th digit of Code Symbol, and specify 16th digit to 20th digit. When odering the instrument without direct mounting adapter, nothing should be filled in the 16th to 20th digit. 2. Unless otherwise described in the specifications, leave the 21st digit blank. 1 2 3 4 5 6 7 8 Digit Description 16, 17 <Process connection (direct mounting adapter)> JIS 10K 15A JIS 10K 20A JIS 20K 15A JIS 20K 20A JIS 30K 15A JIS 30K 20A ANSI/JPI 150LB 1/2" ANSI/JPI 150LB 3/4" ANSI/JPI 300LB 1/2" ANSI/JPI 300LB 3/4" Screw connection Rc1/2 Screw connection Rc3/4 Screw connection Rc1/2 - 14NPT Screw connection Rc3/4 - 14NPT 18 <Material (direct mounting adapter)> Adapter Bolts/nuts (* 1) 316 Stainless Steel Cr-Mo steel/carbon steel 19 <Vent/drain (for direct mounting adapter)> Standard Long type 20 <Gasket (for direct mounting adapter)> Standard (Teflon) (Only Y, W, G, A and D can be specified on 13th digit). For high temperature (spiral gasket) (Only H and S can be specified on 13th digit). 21 <Other options> High accuracy type Low temperature effect type H+J Note FDX 9 10 11 12 13 14 15 16 17 18 19 20 21 0 1 1 1 2 2 1 2 2 3 1 3 2 1H 1 T 2H 2 T SR S 2 SN ST Note 1 Note (*1) For connection of transmitter receiving pressure unit and direct mounting adapter 26 4 W A N 1 2 H J K Digit No. of code Small frange remote seal type pressure transmitter : FDW 1 2 3 4 5 6 7 8 Digit 4 5 6 7 9 Description <Conduit connection> (×1) G1/2 1/2 - 14NPT (×1) Combination with 12th digit code Pg13.5 (×1) “C, E, P, Q” are not available. M20×1.5 (×1) (×2) G1/2 1/2 - 14NPT (×2) Pg13.5 (×2) M20 X 1.5 (×2) <Flange> Material Size and rating 304 stainless JIS 10K 40A steel JIS 10K 50A JIS 20K 40A JIS 20K 50A JIS 30K 40A JIS 30K 50A JIS 63K 40A JIS 63K 50A ANSI/JPI 150LB 1 1/2" ANSI/JPI 150LB 2" ANSI/JPI 300LB 1 1/2" ANSI/JPI 300LB 2" ANSI/JPI 600LB 1 1/2" ANSI/JPI 600LB 2" Carbon steel JIS 10K 40A JIS 10K 50A JIS 20K 40A JIS 20K 50A JIS 30K 40A JIS 30K 50A JIS 63K 40A JIS 63K 50A ANSI/JPI 150LB 1 1/2" ANSI/JPI 150LB 2" ANSI/JPI 300LB 1 1/2" ANSI/JPI 300LB 2" ANSI/JPI 600LB 1 1/2" ANSI/JPI 600LB 2" None 40A, 1 1/2B (Wafer type) 50A, 2B Direct mounting adapter connection (* 1) <Span limit [kPa] > 50.....3000 250...10000 <Material/diapharagm extension> Diaphragm extension (mm) Flange face Diaphragm 0 316L stainless steel 316 stainless steel 50 100 (* 2) 150 200 0 316L stainless steel +Au coating 0 Hastelloy-C Hastelloy-C 0 Monel Monel 0 Tantalum Tantalum <Digital indicator, arrester and communication> Digital indicator Arrester Communication type None None Foundation Fieldbus None Yes Foundation Fieldbus Yes None Foundation Fieldbus Yes Yes Foundation Fieldbus None None Yes Yes None Yes None Yes Profibus Profibus Profibus Profibus Note F DW 9 10 11 12 13 4 14 15 16 17 18 19 20 21 0 Digit No. of code A B C D S T V W Note 1 0 1 2 3 4 5 6 7 A B C D E F G H J K L M N P Q R S T U V W X Y 3 4 Note 2 V A B C D J H M T A E P S R V T W 27 1 2 3 4 5 6 7 8 Digit 10 11 12 13 14 15 Description <Approvals for hazardous, for fieldbus> 9 10 11 12 13 TIIS, Flameproof (Conduit seal) TIIS, Flameproof (Cable gland seal) FM, Flameproof (or explosionproof) CSA, Flameproof (or explosionproof) ATEX, Flameproof B C D E X Approval pending ATEX, Intrinsic safty (Entity) SAA, Flameproof (or explosionproof) Approval pending Approval pending K F ATEX, FISCO Approval pending Note6 4 <Capillary and mounting bracket> Mounting bracket Capillary Armor of Capillary Stainless steel 1.5m PVC (*5) Note5 3m 5m 1.5m Stainless steel 3m 5m <Options> Stainless steel elec. housing Coating of cell Extra SS tag plate None None None Yes None None None Yes None (*3) Note3 Yes Yes None None None Yes Yes None Yes None Yes Yes Yes Yes Yes <Special applications and fill fluid> Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Fluorinated oil (7th digit code “V”, “A”, “B”, “C” and “D”) Oxygen service Chlorine service Fluorinated oil (7th digit code “H” and “T”) High temp. 250°C Silicone oil High temp. and vacuum (250°C) Silicone oil <Teflon membrane> None Yes (Available for 7th digit code “V”, “H”, “M”, “T”. Not availalbe for 5th digit code “Y”, and 13 digit code “H”, “S”.) Note4 <Bolt/nut> (*4) None 6th digit code “3” Cr-Mo alloy hexagon socket head cap bolt/ carbon steel nut 6th digit code “4” Cr-Mo alloy hexagon bolt/carbon steel nut 304 stainless steel bolt/304 stainless steel nut (*2) (*3) (*4) (*5) 14 15 16 17 18 19 20 21 4 A Note 6: (*6) 28 F DW None (for ordinary locations) Note 1: (*1) Note 2: Note 3: Note 4: Note 5: Note D E L Q R S Y B C E M N P Q Y W G A D H S Y C Y A B E Direct mounting adapter type is specified at 16th to 20th digit. Direct mounting adapter is available only for 7th digit code “V”. Diaphragm extension is available only for 2" (50A) flanges. Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”. In case of tropical use, select stainless bolts and nuts. Available for 13th digit code “Y, W, G, A, D”. Inquire about in case of 13th other code. In case of 10th code is “4”(ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available. Digit No. of code Specifications of Direct Mounting Adapter {for 15, 20A (1/2, 3/4”) connection} and others Note 1. When odering the instrument with direct mounting adapter, specify “Y” in the 5th digit of Code Symbol, and specify 16th digit to 20th digit. When odering the instrument without direct mounting adapter, nothing should be filled in the 16th to 20th digit. 2. Unless otherwise described in the specifications, leave the 21st digit blank. 1 2 3 4 5 6 7 8 Digit Description Note 16, 17 <Process connection (direct mounting adapter)> JIS 10K 15A JIS 10K 20A JIS 20K 15A JIS 20K 20A JIS 30K 15A JIS 30K 20A JIS 63K 15A JIS 63K 20A ANSI/JPI 150LB 1/2" ANSI/JPI 150LB 3/4" ANSI/JPI 300LB 1/2" ANSI/JPI 300LB 3/4" ANSI/JPI 600LB 1/2" ANSI/JPI 600LB 3/4" Screw connection Rc1/2 Screw connection Rc3/4 Screw connection Rc1/2 - 14NPT Screw connection Rc3/4 - 14NPT 18 <Material (direct mounting adapter)> Note 1 Adapter Bolts/nuts (* 1) 316 Stainless Steel Cr-Mo steel/carbon steel 19 <Vent/drain (for direct mounting adapter)> Standard Long type 20 <Gasket (for direct mounting adapter)> Standard (Teflon)(Only Y, W, G, A and D can be specified on 13th digit). For high temperature (spiral gasket) (Only H and S can be specified on 13th digit). 21 <Other options> High accuracy type F DW 9 10 11 12 13 14 15 16 17 18 19 20 21 4 Digit No. of code 1 1 1 2 2 1 2 2 3 1 3 2 6 1 6 2 1H 1T 2H 2T 4H 4T SR S2 SN ST W A N 1 2 H Note1: (* 1) For connection of transmitter receiving pressure unit and direct mounting adapter 29 ORDERING INFORMATION When ordering this instrument, specify: 1. CODE SYMBOLS 2. Calibration range (XD_SCALE) and unit (CAL_UNIT) • Unless specified, the range is maximum span. 3. Output scale and unit (OUT_SCALE) • Unless specified, the scale is the same as the calibration range. 4. Output mode (L_TYPE) • Select any of Direct/Indirect Linear/Indirect SORT. • Unless otherwise specified, q In case of output scale in flow rates Indirect SORT (extraction output) w In case of other units Indirect linear (proportional output) 5. Low flow rate cut point (specify only when needed for flow measurement) • Specify in percentages of output scale 6. Output orientation (burnout direction) when abnormality is occurred in the transmitter. Select Hold / Overscale / Underscale. Unless specified, output hold function is supplied. 7. Setting of external zero adjustment SW • Select either of “valid” and “invalid” • Unless otherwise specified, “valid” is selected. 8. Tag No. • Up to 26 alphanumerical characters. • Unless otherwise specified, the tag No. is EFB002 (but, not stamped). 9. Node address (if required) • Unless specified, “0 × F0”(Foundation Fieldbus), “0 × 03”(Profibus) 10. Display scale and unit (specify only for the transmitter with a digital indicator) • For the settable range, contact Fuji Electric Co. Ltd. • No low flow cut is performed • Unless otherwise specified, it conforms to the output scale. 30 OUTLINE DIAGRAM OF EACH STANDARD MODEL (Unit:mm) Differential pressure / flow transmitter : FDC < 7th digit code without : B, L, U > Note 2) Vent/drain plug (When the vent/drain plug attatched on the upper side of the detector) In case of 4th digit code “S,V,W,X” 52.5 Down 88 38 U-bolt M8 58 Note 1) Cable gland (option) 37 237 4 Holes 9 Dia. ø80 70 105 ø80 Up 130 120 43.5 “A” Press. conn. 123 MTG. pipe JIS 50A (2B) Fastener (Flameproof only) (10) “B” Conduit conn.2 Zero ADJ. screw “C” Conduit conn. “B” Conduit conn.1 Vent/drain plug 154 Detail “A” (Press. conn.) ø18.5 Detail “B” (Conduit conn.) 59 Detail “C” 43 Earth terminal ø13 H 2.5 ø15 Electronics unit Side vent (option) G 1/2 D Press.conn. (Low pressure side) See table 1 See table 1 41.3 ø7 Press. conn. H A, S G1/2 17 8 Rc1/4 B, T 1/2-14NPT 16 5 1/4-18NPT C, V Pg13.5 8 4.5 1/4-18NPT D, W M20 1.5 16 5 1/4-18NPT E, X Pg13.5 8 4.5 1/4-18NPT Sensor unit Press.conn. (High pressure side) 4-M8 12 Conduit conn. D E F 4th digit of the code symbols 231 E 17 8 F Oval flange screw See table 1 Oval flange screw 7/16-20UNF Screw depth 15 7/16-20UNF Screw depth 15 M10 Screw depth 15 M10 Screw depth 15 7/16-20UNF Screw depth 15 Table 1 54 70 104 CONNECTION DIAGRAM Note 1) Cable gland is supplied in case of flameproof packing type. ø11 cable is suitable. Note 2) The pressure connector is located on the down side surface of the detector, when the vent /drain plug is attatched on the upper side of the detector. CK CK (M4 screws) Do not connect. Field bus 31 Differential pressure / flow transmitter : FDC < 7th digit code : B, L, U > “A” or “B” Press. conn. MTG. pipe JIS 50A (2B) U-bolt M8 Zero ADJ. screw In case of 4th digit code “S,V,W,X” “C” Conduit conn.2 41.3 Fastener (Flameproof only) (10) Oval flange screw See table 1 ø80 120 52.5 70 ø80 105 Up 88 Down 38 Note 1) Cable gland (option) 40 58 4 Holes 9 Dia. 240 “D” Conduit conn. “C” Conduit conn.1 Vent/drain plug 186 91 Detail “A” (Press. conn.) Detail “C” (Conduit conn.) Earth terminal Electronics unit G 1/2 E ø4 234 F 17 H 1 0 2 -0.1 +0.2 +0.1 43 ø13 ø15 ø16 ø12 Detail “D” Sensor unit See table 1 Detail “B” (Press. conn) ø16 Press.conn. (Low pressure side) Press.conn. (High pressure side) 4-M8 12 10 1/4-18NPT 54 70 104 ø4 4th digit of the code symbols E Conduit conn. F H A, S G1/2 17 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20 1.5 16 5 E, X Pg13.5 8 4.5 Oval flange screw 7/16-20UNF Screw depth 10 7/16-20UNF Screw depth 10 M10 Screw depth 10 M10 Screw depth 10 7/16-20UNF Screw depth 10 Table 1 Note 1) Cable gland is supplied in case of 10th digit code “C”. ø11 cable is suitable. 32 CONNECTION DIAGRAM CK CK (M4 screws) Do not connect. Field bus Pressure transmitter : FDG < 7th digit code without : B, L, U > Note2) Vent/drain plug (When the vent/drain plug attached on the upper side of the detector) “B” Conduit conn.2 In case of 4th digit code “S,V,W,X” 52.5 58 Down 88 38 U - bolt M8 ø80 70 105 ø80 Up 130 104 43.5 “A” Press. conn. 123 MTG. Pipe JIS 50A (2B) Fastener (Flameproof only) (10) Zero ADJ. screw 37 Cable gland (option) 237 216 (6th digital code “5”) 4 holes 9 dia. Note1) Vent/drain plug “C” Conduit conn. “B” Conduit conn.1 154 Detail “A” (Press. conn.) ø18.5 Detail “B” (Conduit conn.) Earth terminal Detail “C” 59 43 ø13 H G 1/2 D Side vent (option) See table 1 See table 1 231 210 (6th digit code “5”) ø7 Electronics unit Oval flange screw See table 1 41.3 E 17 8 F 2.5 ø15 Sensor unit 4-M8 12 Conduit conn. D E F 4th digit of the code symbols Press.conn. H A, S G1/2 17 8 Rc1/4 B, T 1/2-14NPT 16 5 1/4-18NPT C, V Pg13.5 8 4.5 1/4-18NPT D, W M20 1.5 16 5 1/4-18NPT E, X Pg13.5 8 4.5 1/4-18NPT Oval flange screw 7/16-20UNF Screw depth15 7/16-20UNF Screw depth15 M10 Screw depth15 M10 Screw depth15 7/16-20UNF Screw depth15 27 54 70 104 Table 1 Note1) Note2) CONNECTION DIAGRAM Cable gland is supplied in case of flamproof packing type. ø11 cable is suitable. The pressure connector is located on the down side surface of the detector, when the vent / drainplug is attatched on the upper side of the detector. CK CK (M4 screws) Do not connect. Field bus 33 Pressure transmitter : FDG < 7th digit code : B, L, U > 52.5 43.5 Down 88 38 104 70 ø80 105 Up ø80 “C” Conduit conn.2 (10) U - bolt M8 Fastener (Flameproof only) In case of 4th digit code “S,V,W,X” Zero ADJ. screw MTG. Pipe JIS 50A (2B) 58 40 Cable gland (option) Note) 4 holes 9 dia. 240 “C” Conduit conn.1 “D” Conduit conn. 155 Detail “A” (Press. conn.) 4th digit code “A. S” ø16 Earth terminal 60 43 ø13 ø15 2 -0.1 +0.2 Detail “D” Detail “C” (Conduit conn.) Electronics unit F 17 H 1 0 ø12 +0.1 ø4 234 G1/2 E See table 1 P Detail “B” 4th digit code “B,C,D,E,T,V,W,X” View from P 4-M8 12 ø16 “A” or “B” Press. conn. Vent/drain plug 41.3 10 1/4-18NPT 54 Oval flange screw See table 1 ø4 Conduit conn. D E F 4th digit of the code symbols A, S G1/2 17 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20 1.5 16 5 E, X Pg13.5 8 4.5 7/16-20UNF Screw depth10 7/16-20UNF Screw depth10 M10 Screw depth10 M10 Screw depth10 7/16-20UNF Screw depth10 Cable gland is supplied in case of 10th digit code “C”. ø11 cable is suitable. 34 104 Oval flange screw Table 1 Note) 98 70 CONNECTION DIAGRAM CK CK (M4 screws) Do not connect. Field bus Sensor unit Absolute pressure transmitter : FDA Vent/drain plug Note2) (When the nent/drain plug attached on the upper side of the detector) Fastener (Flameproof only) “B” Conduit conn.2 52.5 58 ø80 Down 88 38 U - bolt M8 104 70 105 ø80 Up 43.5 (10) Zero ADJ. screw “A” Press. conn. 123 MTG. Pipe JIS 50A (2B) In case of 4th digit code “S,V,W,X” 37 Cable gland (option) 237 4 holes 9 dia. Note1) “C” Conduit conn. “B” Conduit conn.1 Vent / Drain Plug 155 60 Detail “A” (Press. conn.) Datail “B” (Conduit conn.) Detail “C” ø7 43 Earth terminal Electronics unit ø13 ø15 H ø18.5 2-M8 12 See Table 1 Conduit conn. D E F 4th digit of the code symbols Press.conn. H G1/2 17 8 Rc1/4 B, T 1/2-14NPT 16 5 1/4-18NPT C, V Pg13.5 8 4.5 1/4-18NPT D, W M20 1.5 16 5 1/4-18NPT E, X Pg13.5 8 4.5 1/4-18NPT A, S Oval flange screw 27 7/16-20UNF screw depth15 7/16-20UNF screw depth15 M10 screw depth15 M10 screw depth15 7/16-20UNF screw depth15 120 CONNECTION DIAGRAM Cable gland is supplied in case of flamproof packing type. CK CK ø11 cable is suitable. Note2) 50 70 Table 1 Note1) Side vent (option) G 1/2 D See Table 1 Sensor unit 41.3 2.5 E 17 8 F 231 Oval flange screw See table 1 The pressure connector is located on the down side surface of the detector, when the vent / drainplug is attached on the upper side of the detector. (M4 screws) Do not connect. Field bus 35 Level transmitter : FDE < 7th digit code without : B, L, U > Vent / drain plug Note 2) (When the vent /drain plug attatched on the upper side of the detector) In case of 4th digit code “S, V, W, X” Flange : ANSI/JPI -150LB-3B Zero ADJ.screw Fastener (Flameproof only) (10) N holes h dia 43.5 105 Down 88 52.5 ø80 Up ø80 “B” Conduit conn.2 “A” L.P. conn. L2 Note 1) Cable gland (option) L1 Vent / drain plug t H.P. conn. øD øE øF øG øH t (Flange) N-øh See table 1 11th degit code Electronics unit 185 150 126 100 73 38 8-19 JIS-10K-80A 200 160 126 100 73 42 8-23 JIS-20K-80A 210 170 126 100 73 48 8-23 JIS-30K-80A 210 175 151 103 96 38 8-19 JIS-10K-100A 240 195 151 103 96 52 8-25 JIS-30K-100A 191 152.5 126 100 73 44 4-20 ANSI-150LB-3B Y 0 9.5 ~ 13 A E 50 10 ~ 17 B F 100 10.5 ~ 17.5 C G 150 11 D H 200 11.5 ~ 18.5 Press.conn. J G1/2 17 8 Rc1/4 B, T 1/2-14NPT 16 5 1/4-18NPT 1/4-18NPT 210 168 126 100 73 49 8-23 ANSI-300LB-3B 210 168 126 100 73 52 8-23 ANSI-600LB-3B C, V Pg13.5 8 229 190.5 151 103 96 44 8-20 ANSI-150LB-4B D, W M20 1.5 16 5 1/4-18NPT 254 200 151 103 96 52 8-23 ANSI-300LB-4B 200 160 126 100 73 44 8-18 DIN PN40 DN80 E, X Pg13.5 8 1/4-18NPT 220 180 151 103 96 40 8-18 DIN PN16 DN100 4.5 4.5 Table 1 CONNECTION DIAGRAM CK CK (M4 screws) Do not connect. Field bus L1 L2 L3 360 160 296 354 154 290 ~ 18 A, S Note 1) Cable grand is suppled in case of flamproof packing type. ø11 cable is suitable. Note 2) The pressure connector is located on the down side surface of the detector, when the vent / detector. 36 Mass apprpx. (kg) L (mm) Conduit conn. K M N 4th digit of the code symbols G1/2 K See table 1 Earth terminal Sensor unit ø13 ø15 ø7 L3 Detail “C” Detail “B” (Conduit conn.) 17 43 143 59 27 øG øH øD øE øF J 48 Inner of gasket Detail “A” (L.P conn.) ø18.5 Oval flang screw See table 1 M N 41.3 2.5 20 8 L “C” Conduit conn. “B” Conduit conn.1 Oval flage screw 7/16-20UNF Screw depth15 7/16-20UNF Screw depth15 M10 Screw depth15 M10 Screw depth15 7/16-20UNF Screw depth15 Level transmitter : FDE < 7th digit code : B, L, U > Oval flange screw See table 1 Fastener (Flameproof only) Zero ADJ.screw (10) N holes h dia 52.5 107 ø80 Up ø80 “A” or “B” L.P. conn. 41.3 In case of 4th digit code “S, V, W, X” 105 Flange : ANSI/JPI -150LB-3B 88 Down L2 Note 1) Cable gland (option) L1 Vent / drain plug “C” Conduit conn.1 t Inner of gasket 91 1/4-18NPT +0.2 ø12 +0.1 0 1 186 43 40.5 ø16 ø16 46.4 øH øG øD øE øF Detail “B” (L.P conn.) Detail “A” (L.P. conn.) 4th digit code “S” Earth terminal 10 20 2 -0.1 L “D” Conduit conn. ø4 L3 Detail “C” (Conduit conn.) H.P. conn. L (mm) Mass apprpx. (kg) Y 0 A E 50 B F 100 12.5 ~ 19.5 C G 150 13 øD 12 L1 L2 L3 350 150 286 CK CK 144 200 øE 150 øF øG 100 200 160 126 100 210 170 126 100 210 175 151 103 240 195 151 103 191 152.5 126 210 168 126 210 168 229 (M4 screws) K G1/2 See table 1 290 Do not connect. ~ 20 Field bus 13.5 ~ 20.5 126 ø15 CONNECTION DIAGRAM ~ 19 344 D H 185 11.5 ~ 15 Detail “D” ø13 17 11th degit code Electronics unit M N Sensor unit øH 73 73 t 38 (Flange) N-øh 8-19 JIS-10K-80A 42 8-23 JIS-20K-80A 73 48 8-23 JIS-30K-80A 96 38 8-19 JIS-10K-100A 96 52 8-25 JIS-30K-100A 100 73 44 4-20 ANSI-150LB-3B 100 73 49 8-23 ANSI-300LB-3B 126 100 73 52 8-23 ANSI-600LB-3B 190.5 151 103 96 44 8-20 ANSI-150LB-4B 254 200 151 103 96 52 8-23 ANSI-300LB-4B 200 160 126 100 73 44 8-18 DIN PN40 DN80 220 180 151 103 96 40 8-18 DIN PN16 DN100 4th digit of the code symbols Conduit conn. K M N A, S G1/2 17 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20 1.5 16 5 E, X Pg13.5 8 4.5 Oval flage screw 7/16-20UNF Screw depth10 7/16-20UNF Screw depth10 M10 Screw depth10 M10 Screw depth10 7/16-20UNF Screw depth10 Table 1 Note 1) Cable grand is suppled in case of 10th digit code “C”. ø11 cable is suitable. 37 Remote seal type differential pressure transmitter : FDD In case of 4th digit code “S,V,W” MTG. pipe JIS 50A (2B) “A” Conduit conn.2 Fastener (Flamproof only) (10) Zero ADJ. screw 104 ø80 Up 105 52.5 70 ø80 U-bolt M8 38 4 holes 9 dia. 88 Down 28 “B” Conduit conn. 58 “A” Conduit conn. 1 228 Cable gland (option) N holes h dia. øE P øF Note) No flange is attached in case of 5th digit code “P,Q”. øG øH øD Inner of gasket 20 L t 48 Detail “A” (Conduit donn.) ø15 270 43 Detail “B” ø13 Earth tarminal 222 K M 17 Electronics unit G1/2 J See table 1 4th digit of the code symbols S Conduit donn. J K M A, S G1/2 17 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20 1.5 16 5 S 54 70 120 Table 1 7th digit code øD øE øF øG øH t P (Flange) N-øh Mass. appox. (kg) 11th digit code S 11th digit (m) code 0 14~19.5 D,Q 1.5 M,V 185 150 126 100 73 38 116 8-19 JIS-10K-80A A,F 50 15~30.5 E,R 3 N,W 200 160 126 100 73 42 116 8-23 JIS-20K-80A B,J 100 15.5~31 L,S 5 P,X 210 170 126 100 73 48 116 8-23 JIS-30K-80A C,K 150 16~31.5 F,T 6 210 175 151 103 96 38 141 8-19 JIS-10K-100A D,L 200 16.5~32 240 195 151 103 96 52 141 8-25 JIS-30K-100A 191 152.5 126 100 73 44 116 4-20 ANSI-150LB-3B 210 168 126 100 73 49 116 8-23 ANSI-300LB-3B 210 168 126 100 73 52 116 8-23 ANSI-600LB-3B 229 190.5 151 103 96 44 141 8-20 ANSI-150LB-4B 254 200 151 103 96 52 141 8-23 ANSI-300LB-4B 200 160 126 100 73 44 116 8-18 DIN PN40 DN80 220 180 151 103 96 40 141 8-18 DIN PN16 DN100 V,H,M,T,P,R L CONNECTION DIAGRAM CK CK NOTE) Cable gland is supplied in case of flamproof packing type. ø11 cable is suitable. (M4 screws) Do not connect. Field bus 38 Sensor unit H.P. L.P. S (m) 7 8 10 Remote seal type pressure transmitter : FDB 1 2 3 FDB 4 Note) Cable gland is supplied in case of flamproof packing type. ø11 cable is suitable. In case of 4th digit code “S,V,W” Fastener (Flameproof only) “A” Conduit conn.2 U - Bolt M8 (10) MTG. pipe JIS 50A (2B) Zero ADJ. Screw 38 ø80 104 105 Down 88 52.5 70 ø80 Up 30 Cable gland (Option) Note) 4 holes 9 dia. 58 237 “B” Conduit conn. “A” Conduit conn.1 Inner of gasket Detail “A” (Conduit conn.) N holes h dia. Detail “B” (Conduit conn.) ø13 P 17 K M øG øH G1/2 J 20 L See table 1 t Earth terminal 7th digit code Mass approx.(kg) L V H M T P R 0 A F 50 10.5 B J 100 11.5 C K 150 12 D L 200 12.5 4th digit of the code symbols 9.5 A, S B, T C, V Conduit conn. J K G1/2 17 1/2-14NPT 16 Pg13.5 8 M 8 5 4.5 D, W M20 1.5 5 16 Table 1 øD øE 185 200 191 43 60 No flange is attached in case of 5th digit code “P,Q,R” . Electronics unit 231 øE øF øD ø15 2-M8 12 S øF øG øH t 150 126 100 73 160 126 100 73 210 170 126 100 210 175 151 191 152.5 210 Sensor unit 50 70 120 P N-øh (Flange) 38 116 8-19 JIS-10K-80A 42 116 8-23 JIS-20K-80A 73 48 116 8-23 JIS-30K-80A 103 96 38 141 8-19 JIS-10K-100A 126 100 73 44 116 4-20 ANSI-150LB-3B 168 126 100 73 49 116 8-23 ANSI-300LB-3B 210 168 126 100 73 52 116 8-23 ANSI-600LB-3B 229 190.5 151 103 96 44 141 8-20 ANSI-150LB-4B 200 160 126 100 73 44 116 8-18 DIN PN40 DN80 220 180 151 103 96 40 141 8-18 DIN PN16 DN100 CONNECTION DIAGRAM CK CK (M4 screws) Do not connect. Field bus 11th digit code S (m) D Q 1.5 E R 3 L S 5 F T 6 M V 7 N W 8 P X 10 39 Remote seal type pressure transmitter : FDB 4 K 5 V4 Mtg. JIS 50A (2B) 4th of Code symbols “S, V, W” type is attached Zero/span adj. screw (10) FDB U-bolt M8 Fastener (flameproof model only) 104 φ80 105 Down 88 52.5 70 φ80 Up 38 30 4 holes 9 dia. 58 237 *Cable gland (option) 20 “A” Conduit conn. “B” Conduit conn. 45 G1 Packing 2 53 18 100 With field ind. 191 –0.1 φ23.6 –0.2 Earth terminal (both side) See table 1 φ30 –0.1 –0.2 43 60 Details of “B” Details of “A” φ13 φ15 D 17 206 E S C G1/2 See table 1 4th of Code symbols S 2–M8x12 Conduit conn. D C E 17 8 G1/2 Earth terminal M4 11th of Code symbols D Q S (m) 1.5 70 50 120 T 1/2-14NPT V Pg13.5 W M20x1.5 16 5 8 4.5 16 5 No. 8-32UNC E R 3 M4 L S 5 F T 6 M V 7 N W 8 P X 10 M4 CONNECTION DIAGRAM CK CK (M4 screws) Table 1 Note *: Cable gland is supplied in case of flameproof packing type. φ11 cable is suitable. 40 Do not connect. Field bus Small frange type level transmitter : FDY < 7th digit code without : B, L, U > Note2) Vent / drain plug (When the vent / drain plug attatched on the upper side of the detector) In case of frange with 4 bolt holes In case of 4th digit code “S, V, W, X” (10) Zero ADJ. screw 43.5 105 52.5 Fastener (Flameproof only) N holes h dia. Up ø80 “A” L. P. conn. ø80 “B” Conduit conn.2 88 Down L2 Note) Cable grand (option) “C” Conduit conn. L1 Vent / drain plug Detail “A” ø7 Detail “B” ø15 Detail “C” ø13 H ø18.5 H.P. conn L3 K 8 2.5 43 øD øE øF ø49 ø48 M 48 Oval flange screw See table 1 17 L.P. conn. 41.3 27 t 143 L 20 “B” Conduit conn.1 J G1/2 See table 1 Inner of gasket Sensor unit Electronics unit L 11th digit of Code symbols [mm] øD 0, G 140 105 36 4-19 JIS-10K-40A 1, H 155 120 36 4-19 JIS-10K-50A 2, J 140 105 39 4-19 JIS-20K-40A øE t N-øh Flange 100 10.5 to 17.5 C 150 11 D 200 11.5 to 18.5 17 8 B, T 1/2-14NPT 18 5 8 4.5 C, V Pg13.5 M20 Pg13.5 155 120 38 8-19 JIS-20K-50A 4, L 160 120 42 4-23 JIS-30K-40A E, X 5, M 165 130 42 8-19 JIS-30K-50A A, Q 127 B, R 152 120.6 39.5 4-20 ANSI/JPI-150-2B C, S 156 114.3 41 4-23 ANSI/JPI-300LB-1 1/2B D, T 165 8-20 ANSI/JPI-300LB-2B 42.5 B G1/2 3, K 127 0 50 A, S D, W 98.4 37.5 Y A CONDUIT CONN. J K M 4TH DIGIT OF THE CODE SYMBOLS 5th digit of Code symbols 1.5 Mass approx, [kg] 16 5 8 4.5 9.5 to 12 10 L1 L2 L3 360 160 296 to 17 354 154 290 to 18 PRESS.CONN. Oval flange screw H 7/16-20UNF Rc1/4 Screw depth15 7/16-20UNF 1/4-18NPT Screw depth15 M10 1/4-18NPT Screw depth15 M10 1/4-18NPT Screw depth15 7/16-20UNF 1/4-18NPT Screw depth15 Table 1 4-16 ANSI/JPI-150LB-1 1/2B CONNECTION DIAGRAM CK CK (M4 screws) Note) Cable gland is supplied in case of flamproof packing type. Do not connect. ø11 cable is suitable. Field bus 41 Small frange type level transmitter : FDY < 7th digit code : B, L, U > Oval flange screw See Table 1 In case of 4th digit code “S,V,W, X” 41.3 N holes h dia. 28 115 ø80 52.5 Up 107 Fastener (Flameproof only) 43.5 Zero ADJ. screw ø80 “C” Conduit conn. 2 “A” or “B” L. P. conn. 10 In case of flange with 4 bolt holes 88 Down 150 Note) Cable grand (option) 350 Vent / drain plug “D” Conduit conn. “C” Conduit conn. 1 t Details of “A” 4th of code symbols “A, S” type ø16 –0.2 ø12+0.1 1/4 -18NPT 10 øD øE øF ø49 40.5 91 43 186 1 H.P. conn Details of “B” 4th of code symbols “B, C, D, E, T, V, W, X” type ø16 0 2 –0.1 20 286 Inner of gasket ø4 Earth terminal Detail “C” Sensor unit Detail “D” ø13 Electronics unit M ø15 t N-øh Flange 17 øE K 5th digit of Code øD symbols 0, G 140 105 36 4-19 JIS-10K-40A 1, H 155 120 36 4-19 JIS-10K-50A 2, J 140 105 39 4-19 JIS-20K-40A 3, K 155 120 38 8-19 JIS-20K-50A 4, L 160 120 42 4-23 JIS-30K-40A 5, M 165 130 42 8-19 JIS-30K-50A A, Q 127 98.4 37.5 4-16 ANSI/JPI-150LB-1 See table 1 1/2B 152 120.6 39.5 4-20 ANSI/JPI-150-2B C, S 158 114.3 41 4-23 ANSI/JPI-300LB-1 D, T 165 8-20 ANSI/JPI-300LB-2B 42.5 Note) Cable gland is supplied in case of 10th digit code “C”. ø11 cable is suitable. Conduit conn. J K M 4th digit of the code symbols B, R 127 G1/2 J 1/2B A, S G1/2 17 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20 16 5 E, X Pg13.5 8 4.5 15 Oval flange screw 7/16-20UNF Screw depth 10 7/16-20UNF Screw depth 10 M10 Screw depth 10 M10 Screw depth 10 7/16-20UNF Screw depth 10 Table 1 CONNECTION DIAGRAM CK CK (M4 screws) Do not connect. Field bus 42 Small frange remote seal type differential pressure transmitter : FDX “A” Conduit conn.2 In case of 4th digit code “S,V,W” Zero ADJ. screw ø80 104 88 70 38 28 4 holes 9 dia. Fastene (Flameproof only) (10) U-bolt M8 ø80 52.5 105 MTG. pipe JIS 50A (2B) 58 228 “B” Conduit conn. Note) Cable gland (option) Inner of gasket N holes h dia. 71 øD øE ø84 ø49 ø48 “A” Conduit conn. 1 20 L Detail “A” t No flange is attached in case of 5th digit code “W, X” Detail “B” ø13 ø15 48 270 43 M Earth terminal K 17 Electronics unit J 222 G1/2 See table 1 S S 2-M8 12 L.P. Sensor unit H.P. Inner of gasket 70 120 2-M6 screw depth 9 62 71 ø84 ø49 CONNECTION DIAGRAM 20 <Wafer type> 5th digit of code symbols 0,G 1,H 2,J 3,K 4,L 5,M 6,N 7,P A,Q B,R C,S D,T E,U F,V CK CK Note : In case of wafer type, flange is excluded from the scope of supply. Mount flange, referring to the view. øD øE t N-øh Flange 140 155 140 155 160 165 175 185 127 152 156 165 156 165 105 120 105 120 120 130 130 145 98.4 120.6 114.3 127 114.3 127 36 36 38 38 42 42 52 54 37.5 39.5 41 42.5 42.5 45.5 4-19 4-19 4-19 8-19 4-23 8-19 4-25 8-23 4-16 4-20 4-23 8-20 4-23 8-20 JIS-10K-40A JIS-10K-50A JIS-20K-40A JIS-20K-50A JIS-30K-40A JIS-30K-50A JIS-63K-40A JIS-63K-50A ANSI/JPI-150LB-1 1/2B ANSI/JPI-150LB-2B ANSI/JPI-300LB-1 1/2B ANSI/JPI-300LB-2B ANSI/JPI-600LB-1 1/2B ANSI/JPI-600LB-2B (M4 screws) Do not connect. Field bus Conduit conn. 4th digit of Code symbols J K M 1 A, S G /2 17 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20 16 5 1.5 11th digit of Capillary Code symbols length : S [mm] D,Q E,R L,S 1500 3000 5000 Table 1 7th digit of Code symbols V, H, M, T A B C D L 0 50 100 150 200 Mass approx. [kg] 14 to 19.5 15 to 30.5 15.5 to 31 16 to 31.5 16.5 to 32 NOTE ) Cable gland is supplied in case of flameproof packing type. ø11 cable is suitable. 43 Small frange remote seal type differential pressure transmitter : FDX <With direct mount adaptor> Vent/drain plug N holes, h dia. øF øE øD ø84 25 (102) Long vent/drain plug (option) S L. P. H. P. t 80 20 MTG. pipe JIS 50A(2B) Zero ADJ. screw “A” Conduit conn.2 ø80 104 88 70 38 28 4 holes 9 dia. Fastener (Flameproof only) In case of 4th digit code “S,V,W” ø80 52.5 105 (10) U-bolt M8 Note) 228 58 “B” Conduit conn. Cable gland (option) “A” Conduit conn. 1 270 48 43 Detail “A” Earth terminal Detail “B” ø13 M ø15 222 17 K J Electronics unit G1/2 Table 1 4th digit of code symbols A, S Conduit conn. J G1/2 K 17 11th digit of Capillary Code symbols length : S [mm] M 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20 1.5 16 5 16th digit of 17th digit of øD code symbols code symbols 1 1 2 2 3 3 1 1 2 2 1 2 1 2 1 2 H T H T 95 100 95 100 115 120 89 98 95 117 D,Q E,R L,S 1500 3000 5000 70 120 øE øF t N-øh 70 75 70 75 80 85 60.3 69.9 66.7 82.5 51 56 51 56 55 60 34.9 42.9 34.9 42.9 12 14 14 16 18 18 11.5 13 14.5 16 4-15 4-15 4-15 4-15 4-19 4-19 4-16 4-16 4-16 4-20 JIS-10K-15A JIS-10K-20A JIS-20K-15A JIS-20K-20A JIS-30K-15A JIS-30K-20A ANSI/JPI-150LB 1/2B ANSI/JPI-150LB 3/4B ANSI/JPI-300LB 1/2B ANSI/JPI-300LB 3/4B CONNECTION DIAGRAM CK CK 44 (M4 screws) Do not connect. Field bus Note ) Cable gland is supplied in case of flameproof packing type. ø11 cable is suitable. 62 Flange Sensor unit Small frange remote seal type differential pressure transmitter : FDX <With direct mount adaptor (screw connection type)> Vent/drain plug Low press. conn. “D” (102) 25 Long vent/drain plug (option) ø84 High press. conn. “D” S 20 23 Zero ADJ. screw MTG. pipe JIS 50A (2B) U- bolt M8 ø80 104 88 70 Fastener (Flameproof only) In case of 4th digit code “S,V,W” ø80 52.5 105 (10) “A” Conduit conn.2 38 28 Note) 4 holes 9 dia. 58 Cable gland (option) 228 “A” Conduit conn. 1 Detail “A” Detail “B” ø13 CONNECTION DIAGRAM CK CK 270 48 43 Earth terminal (M4 screws) Electronics unit K 17 M ø15 “B” Conduit conn Do not connect. G1/2 Field bus 222 J Table 1 4th digit of Code symbols A, S G1/2 Conduit conn. J K M 17 8 1/2-14NPT B, T 16 5 C, V Pg13.5 8 4.5 D, W M20 16 5 16th digit of Code symbols 1.5 17th digit of Code symbols Sensor unit 11th digit of Capillary Code symbols length : S [mm] D,Q E,R L,S Press. conn."D" S R Rc 1/2 S N 1/2-14NPT S 2 Rc3/4 S T 3/4-14NPT 1500 3000 5000 70 120 62 NOTE ) Cable gland is supplied in case of 10th digit code “C”. ø11 cable is suitable. 45 Small frange remote seal type pressure transmitter : FDW “A” Conduit conn.2 In case of 4th digit code “S,V,W” U - bolt M8 Zero adj. screw Fastener (Flameproof only) (10) MTG. pipe JIS 50A (2B) 38 4 holes 9 dia. ø80 104 105 Down 88 52.5 70 ø80 Up 37 Note) Cable gland (option) 58 237 “B” Conduit conn. “A” Conduit conn.1 N holes h dia. Detail “B” (Conduit conn.) ø13 J 71 17 K øD øE ø84 ø49 ø48 M Detail “A” (Conduit conn.) ø15 G1/2 See table 1 20 L Inner of gasket t 191 43 60 No flange is attached in case of 5th digit code “W,X” Earth terminal 2-M6 screw depth 9 Inner of gasket 231 71 ø84 ø49 Electronics unit S 20 <Wafer type> 7th digit of Code symbols L Mass approx. [kg] V, H, M, T A B C D 0 50 100 150 200 9.5 10.5 11.5 12 12.5 5th digit of code symbols øD 0,G 1,H 2,J 3,K 4,L 5,M 6,N 7,P A,Q B,R C,S D,T E,U F,V 140 155 140 155 160 165 175 185 127 152 156 165 156 165 11th digit of Capillary Code symbols length : S [mm] D, Q E, R L, S 70 120 1500 3000 5000 øE øt N-øh (Flange) 105 120 105 120 120 130 130 145 98.4 120.6 114.3 127 114.3 127 36 36 38 38 42 42 52 54 37.5 39.5 41 42.5 42.5 45.5 4-19 4-19 4-19 8-19 4-23 8-19 4-25 8-23 4-16 4-20 4-23 8-20 4-23 8-20 JIS-10K-40A JIS-10K-50A JIS-20K-40A JIS-20K-50A JIS-30K-40A JIS-30K-50A JIS-63K-40A JIS-63K-50A ANSI/JPI-150LB-1 1/2B ANSI/JPI-150LB-2B ANSI/JPI-300LB-1 1/2B ANSI/JPI-300LB-2B ANSI/JPI-600LB-1 1/2B ANSI/JPI-600LB-2B 50 A, S G1/2 17 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20 1.5 16 5 Note) Cable gland is supplied in case of flamproof packing type. ø11 cable is suitable. CONNECTION DIAGRAM Conduit conn. J K M 4TH DIGIT OF THE CODE SYMBOLS Table 1 46 Sensor unit CK CK (M4 screws) Do not connect. Field bus Small frange remote seal type pressure transmitter : FDW <With direct mount adaptor> øF ø84 N holes h dia. øE øD Vent/drain plug (t) In case of ANSI/JPI-600LB flange (6.4) 25 (102) Long vent/drain p lug (added specification) S t Zero ADJ. screw In case of 4th digit code “S,V,W” 4 holes 9 dia. Down 88 58 ø80 ø80 Up 52.5 70 37 38 Fastener (flameproof only) (10) “A” Conduit conn.2 104 MTG. pipe JIS 50A (2B) U - bolt M8 80 105 20 Cable gland (option) note) “A” Conduit conn.1 237 “B” Conduit conn. 60 Detail “A” (Conduit conn.) Earth terminal Electronics unit J 231 K 17 M ø15 Detail “B” (Conduit conn.) ø13 191 43 G1/2 Sensor unit Table 1 4TH DIGIT OF THE CODE SYMBOLS A, S CONDUIT CONN. J K M G1/2 17 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20 1.5 16 5 16th of 17th of code symbols code symbols øD 1 1 2 2 3 3 6 6 1 1 2 2 4 4 NOTE) 1 2 1 2 1 2 1 2 H T H T H T 95 100 95 100 115 120 120 135 89 98 95 117 95 117 11th digit of Capillary Code symbols length : S [mm] D, Q E, R L, S øE øF t N-øh 70 75 70 75 80 85 85 95 60.3 69.9 66.7 82.5 66.7 82.5 51 56 51 56 55 60 55 60 34.9 42.9 34.9 42.9 34.9 42.9 12 14 14 16 18 18 23 25 11.5 13 14.5 16 14.5 16 4-15 4-15 4-15 4-15 4-19 4-19 4-19 4-23 4-16 4-16 4-16 4-20 4-16 4-20 1500 3000 5000 70 120 Flange JIS-10K-15A JIS-10K-20A JIS-20K-15A JIS-20K-20A JIS-30K-15A JIS-30K-20A JIS-63K-15A JIS-63K-20A ANSI/JPI-150LB 1/2B ANSI/JPI-150LB 3/4B ANSI/JPI-300LB 1/2B ANSI/JPI-300LB 3/4B ANSI/JPI-600LB 1/2B ANSI/JPI-600LB 3/4B 50 CONNECTION DIAGRAM CK CK (M4 screws) Do not connect. Field bus Cable gland is supplied in case of flamproof packing type. ø11 cable is suitable. 47 Small frange remote seal type pressure transmitter : FDW <With direct mount adaptor (screw connection type)> Vent/drain plug (102) 25 Long vent/drain plug (added specification) ø84 Press. conn. “D” S 20 23 Zero ADJ. screw (10) “A” Conduit conn.2 Fastener (Flameproof only) ø80 104 ø80 Up Down 88 52.5 70 38 In case of 4th digit code “S,V,W” 105 MTG. pipe JIS 50A(2B) U - bolt M8 37 Note) 4 holes 9 dia. 58 Cable gland (option) 237 “B” Conduit conn. “A” Conduit conn.1 Detail “A” (Conduit conn.) ø15 Detail “B” (Conduit conn.) ø13 CONNECTION DIAGRAM M CK CK 60 191 43 Earth terminal (M4 screws) K 17 Electronics unit Do not connect. J G1/2 231 Field bus Table 1 CONDUIT CONN. J K M 4TH DIGIT OF THE CODE SYMBOLS A, S G1/2 17 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20 16 5 1.5 16th digit of 17th digit of Code symbols Code symbols 11th digit of Capillary Code symbols length : S [mm] D, Q E, R L, S Sensor unit 1500 3000 5000 Press. conn."D" S R Rc1/2 S N 1/2 -14NPT S 2 Rc3/4 S T 3/4 -14NPT 70 120 50 Note ) Cable gland is supplied in case of 10th digit code “C”. ø11 cable is suitable. Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan