FUJI EDSX5-85D

ELECTRONIC TRANSMITTER with FIELDBUS
DATA SHEET
Fieldbus is a standard digital communication protocol between field instruments and upper control system. This fieldbus standard
enables interactive communication among the number of I&C manufactures simultaneously and also the usage by exchanging
fieldbus instruments.
FCX-AII Series Electronic Transmitters with FOUNDATION FIELDBUS and PROFIBUS is a fieldbus transmitters utilizing a unique
micromachined capacitance silicon sensor with state-of -the-art microporcessor technology and converting the signal of silicon
sensor to fieldbus protocol.
This fieldbus transmitter can provide many merits of fieldbus as shown in the following “FEATURES”.
FEATURES
1. Fuji Original IC “Frontier-1+ Fieldbus IC”
“Frontier-1+” the original Fieldbus interface controller IC,
developed by Fuji Electric based on IEC Fieldbus Physical
Layer Specification, is installed in FCX-AII (Fieldbus version.).
2. Interoperability
FCX-AII transmitter comply with the latest Foundation
Fieldbus specification and PROFIBUS-PA specification and
provide full interactive interoperability to other transmitters.
In addition, FOUNDATION FIELDBUS FCX-AII transmitters
are certified and registered by ITK4.0, the latest standard
for Interoperability Testing.
3. Reduction of wiring cost
The reduction of wiring cost of instrumentation is realizing
due to multi-drop wiring of fieldbus instruments comparing
to the current instruments.
4. High accuracy, high stability and high reliability
High resolution data transmission with digital communication lead high accuracy, high stability and high reliability.
5. Abundant alarm functions and self-diagnosis
Abundant alarm and maintenance function defined in
Fieldbus specification in addition to process data can be
well supported.
The self-diagnosis including failure of pressure sensor, abnormal of temperature etc. are also provided.
EDSX5-85d
Date
Jul. 31, 2007
Model Configuration
Differential pressure/flow transmitter [model : FDC]
(Standard version and Hydroseal diaphragm version)
Pressure transmitter [type : FDG]
(Standard version and Hydroseal diaphragm version)
Reference page
Reference page
Common specifications
4
Common specifications
4
Individual specifications
5
Individual specifications
6
Code symbols
11
Code symbols
13
Outline diagram
31
Outline diagram
33
Level transmitter [model : FDE]
Absolute pressure transmitter [model : FDA]
Reference page
Reference page
Common specifications
4
Common specifications
Individual specifications
7
Individual specifications
7
Code symbols
15
Code symbols
17
Outline diagram
35
Outline diagram
36
4
Remote seal type differential pressure/flow transmitter [model : FDD] Remote seal type pressure transmitter [model : FDB]
Reference page
2
Reference page
Common specifications
4
Common specifications
Individual specifications
7
Individual specifications
8
Code symbols
19
Code symbols
21
Outline diagram
38
Outline diagram
39
4
Small frange type level transmitter [model : FDY]
Reference page
Common specifications
4
Individual specifications
8
Code symbols
23
Outline diagram
41
Small frange remote seal type
differential pressure/flow transmitter [model : FDX]
Reference page
Common specifications
4
Individual specifications
9
Code symbols
25
Outline diagram
43
Small frange remote seal type
pressure transmitter [model : FDW]
Reference page
Common specifications
4
Individual specifications
9
Code symbols
27
Outline diagram
46
3
SPECIFICATIONS
(1) Common specifications
Function and Performance
Service:
Output signal:
Liquid, gas, and vapour
Digital signal based on fieldbus FOUNDATION protocol or PROFIBUS-PA.
Power supply:
Transmitter operates on 9V to 32V DC at
transmitter terminals.
Quiescent draw current:
16± 2mA
Standard:
Foundation fieldbus
Fieldbus Foundation specification(H1).
(basic device, device type 113, AI function
block)
PROFIBUS PROFILE. Order No.3042
PROFIBUS-PA
Humidity limit:
0 to 100% RH
Dielectric strength:
500V AC, 50/60Hz 1 min., between circuit and earth.
Insulation resistance:
More than 100MΩ at 500V DC.
Structure and Material
Electrical connections:
G1/2, 1/2-14 NPT, Pg13.5, or M20 × 1.5
conduit, as specified.
And 1 conduit or 2 conduits, as specified.
Process connections:
Model
FDC, FDG, FDA
FDE, FDY (LP side)
PROFIBUS-PA Version 3.0
Transmission cycle (Macro cycle):
Foundation fieldbus
250ms min.
PROFIBUS-PA
250ms fix.
Hazardous locations:
Authorities
ATEX
Factory
Mutual
CSA
JIS
Flameproof
Ex II2 GD -EExd IIC T5/T6
Class I II III
Div. 1
Groups B thru. G
Class I II III
Div. 1
Groups C thru. G
Ex do IIB+H2 T4
Note




 Ex iaIIC T4 FISCO
 (Approval pending)





Zero/span adjustment:
Zero and span are adjustable from the
host system. Zero is also adjustable externally from the adjustment screw.
Indication:
None or 5-digit LCD meter, as specified.
Burnout direction: Selectable from the host system.
If self-diagnostic detect transmitter failure, the output will be driven to either
“Output Hold”, “Output Overscale” or
“Output Underscale” modes.
Temperature limit:
Ambient: – 40 to +85°C
(–20 to +80°C for LCD indicator)
(– 40 to +60°C for arrester option)
(–10 to +60°C for fluorinated oil filled
transmitters)
(–10 to +85°C for silicone oil 
 FDB,
“H, S, K”)

FDD

(+20 to +85°C for silicone oil


“J, T”)

Ambient: – 15 to +65°C

(–15 to +60°C for arrester 
 FDW,
option)

(–10 to +60°C for fluorinated  FDX,

oil filled transmitter)
 FDY

(–10 to +60°C for silicone oil 

“H, S”)
For explosionproof units (flameproof
or intrinsic safety), ambient temperature must be within the limits specified in each standard.
4
Process: See individual specifications
Storage: – 40 to +90°C
(FDW, FDX, FDY ··· – 40 to +70°C)
Process connections
1/4-18NPT
or Rc1/4 on 54mm centers,
as specified.
Meets DIN 19243.
FDE, FDY (HP side)
ANSI, DIN or JIS raised face frange.
FDB, FDD, FDW, FDX
See CODE SYMBOLS of each model
(5th digit).
Process-wetted parts material:
See CODE SYMBOLS of each model (7th
digit)
Non-wetted parts material:
Electronics housing: Low copper die-cast
aluminum alloy finished with polyester coating (standard), or 316 stainless
steel (SCS14 per JIS G5121), as specified.
Bolts and nuts: Cr-Mo alloy (standard),
304 stainless steel or 630 stainless
steel, as specified.
See CODE SYMBOLS of each model.
Fill fluid: Silicone oil (standard) or fluorinated oil (Daifloil)
Mounting bracket: 304 stainless steel
Environmental protection:
IEC IP67 and NEMA 6/6P
Mounting:
Model
FDC, FDG, FDA
Process connections
On 60.5mm (JIS 50A) pope using
mounting or direct wall mounting.
FDE, FDY
FDB, FDD, FDW, FDX
Direct process mounting.
Optional Specifications
Varies with model or material. So refer to CODE SYMBOLS.
Indicator:
An optional 5-digit LCD meter with engineering unit is also available.
Oxygen service: Special cleaning procedures are followed
throughout the process to maintain all
process wetted parts oil-free.
The fill fluid is fluorinated oil.
Chlorine service: The fill fluid is fluorinated oil.
Degreasing:
Process-wetted parts are cleaned, but
the fill fluid is standard silicone oil. Not
for use on oxygen or chlorine measurement.
NACE specification:
Metallic materials for all pressure boundary parts comply with NACE MR-01-75.
ASTM B7M or L7M bolts and 2HM nuts
(Class II) are available.
Static pressure rating for code “3” (16
MPa) is degraded to 10MPa.
Vacuum service: Special silicone oil and filling procedure
are applied.
See Fig. 1.
Optional tag plate: An extra stainless steel tag with customer tag data is wired to the transmitter.
Coating of cell: Cell’s surface is finished with epoxy/
polyurethane double coating. Specify if
environment is extremely corrosive.
Accessories
Oval flanges:
(Model FFP, refer to Data Sheet No.
EDS6-10)
Converts process connection to 1/2 -14
NPT or to Rc1/2; in carbon steel or in 316
stainless steel.
Equalizing valves:
(Model FFN, refer to Data Sheet No.
EDS6-10)
Available in Carbon steel or in 316 stainless steel and in pressure rating 16MPa
or 42MPa.
Over range limit: To maximum static pressure limit
Process temperature and negative pressure tolerance limit:
(For details, see Fig. 1)
Filled oil
13th code
Silicone oil (*1)
Fluorinated oil
Silicone oil
Y, G, N
W, A, D
R
CK CK
(M4 screws)
Do not connect.
Field bus
Negative pressure
tolerance limit
2.7 kPa abs
Atmospheric pressure
2.7 kPa abs
Lower limit of static pressure (vacuum limit):
Silicone oil filled sensor:
See Fig. 1
Fluorinated oil filled sensor: 66kPa abs (500mmHg abs)
at temperature below 60°C
Accuracy rating: (including linearity, hysteresis, and repeatability)
Reference conditions, silicone oil fill, 316SS
isolating diaphragms.
Max span above 32kPa model:
For spans greater than 1/10 of URL: ± 0.07% of span
For spans below 1/10 of URL:
0.1 × URL
± 0.02+0.05
% of span
Span
Max span 1kPa, 6kPa model:
For spans greater than 1/10 of URL: ± 0.1% of span
For spans below 1/10 of URL:
0.1 × URL
± 0.05+0.05
% of span
Span
Stability:
± 0.1% of upper range limit (URL) for 3
years
Temperature effect:
Effects per 28°C change between the
limits of – 40°C and +85°C
(
)
(
)
Range code
(6th digit in Code symbols)
Connection diagram
Process
temperatuer
–40 to +120°C
–20 to +80°C
–15 to +120°C
Zero shift
Total effect
“1”/1kPa max. span
“2”/6kPa max. span
± 0.225%
± 0.25%
“3”/32kPa max. span
“5”/130kPa max. span
“6”/500kPa max. span
“8”/3000kPa max. span
± 0.0875%
± 0.1075%
Static pressure effect:
Static pressure code
(5th digit in Code symbols)
(2) Individual specifications
Zero-based spans, reference conditions, silicone oil fill, SS316 isolating diaphragms, output in linear mode, digital trim values equal
to the span setpoints and capillary length of 1.5m.
Diffential Pressure / Flow Transmitter : FDC
Static pressure, range limit:
Type
F DC
F DC
F DC
F DC
F DC
F DC
F DC
F DC
F DC
F DC
F DC
F DC
F DC
Static pressure [MPa]
11
22
23
25
26
33
35
36
38
43
45
46
48
–0.1 to + 3.2
–0.1 to + 10
–0.1 to + 16
–0.1 to + 42
–0.1 to + 30
Range limit [kPa]
+/–
1
+/–
6
+/–
32
+/– 130
+/– 500
+/–
32
+/– 130
+/– 500
+/– 3000
+/–
32
+/– 130
+/– 500
+/– 3000
Zero shift
(% of URL)
Span shift
“1” /1kPa sensor
“2” /6kPa sensor
±0.2% / 1MPa
±0.2% / 3.2MPa
–0.2% /3.2MPa
–0.2% /3.2MPa
“2”
“3”
“4”
±0.05%/10MPa
–0.2% /10MPa
Overrange effect:
Static pressure code
(5th digit in Code symbols)
Zero shift (% of URL)
“1” / 1kPa sensor
“2” / 6kPa sensor
“2”
“3”
“4”
± 0.3% / 1MPa
± 0.1% / 3.2MPa
± 0.1% /10MPa
± 0.1% /16MPa
± 0.25% /42MPa
Mounting position effect:
Zero shift, less than 0.12kPa for a 10° tilt
in any plane.
No effect on span.
This error can be corrected by adjusting
Zero.
Mass{weight}:
Transmitter approximately 4.4kg without
options.
5
Diffential Pressure / Flow Transmitter
Hydroseal Diaphragm version: FDC
Static pressure, range limit:
Type
F DC
F DC
Static pressure [MPa]
Range limit [KPa]
–0.1 to 16
–0.1 to 16
+/– 32
+/– 130
33
35
Over range limit: To maximum static pressure limit
Process temperature and negative pressure tolerance limit:
(For details, see Fig. 1)
Filled oil
13th code
Silicone oil
Fluorinated oil
Silicone oil
Y, G, N
W, A, D
R
Process
temperatuer
–20 to +120°C
–20 to +80°C
–15 to +120°C
Negative pressure
tolerance limit
2.7 kPa abs
Atmospheric pressure
2.7 kPa abs
Lower limit of static pressure (vacuum limit):
Silicone oil filled sensor:
See Fig. 1
Fluorinated oil filled sensor: 66kPa abs (500mmHg abs)
at temperature below 60°C
Accuracy rating: (including linearity, hysteresis, and repeatability)
Reference conditions, silicone oil fill,
316SS isolating diaphragms.
For spans greater than 1/10 of URL: ± 0.15% of span
For spans below 1/10 of URL:
0.1×URL
± 0.1+0.05
% of span
Span
Stability:
± 0.15% of upper range limit (URL) for 3
years
Temperature effect:
Effects per 28°C change between the
limits of – 40°C and +85°C
(
)
Zero shift
Total effect
± 0.175%
± 0.2%
Static pressure effect:
Zero shift
(% of URL)
Span shift
±0.15% /10MPa{100bar}
Range code
(6th digit in Code symbols)
Zero shift (% of URL)
“3”
1 % URL / 16MPa
“5”
0.6 % URL / 16MPa
Lower limit of static pressure (vacuum limit):
Silicone oil filled sensor:
See Fig. 1
Fluorinated oil filled sensor: 66kPa abs (500mmHg abs)
at temperature below 60°C
Accuracy rating: (including linearity, hysteresis, and repeatability)
Reference conditions, silicone oil fill,
316SS isolating diaphragms.
Max span below 10000kPa model:
For spans greater than 1/10 of URL: ± 0.07% of span
For spans below 1/10 of URL:
0.1 × URL
± 0.02+0.05
% of span
Span
Max span 50000kPa model:
For spans greater than 1/10 of URL: ± 0.1% of span
For spans below 1/10 of URL:
0.1 × URL
± 0.05+0.05
% of span
Span
Stability:
± 0.1% of upper range limit (URL) for 3
years
Temperature effect:
Effects per 28°C change between the
limits of – 40°C and +85°C
Zero shift: ± 0.0875%
Total effect: ± 0.1075%
Overrange effect: Zero shift; 0.2% of URL for any overrange
to maximum limit
Mounting position effect:
Zero shift, less than 0.1kPa for a 10° tilt
in any plane.
No effect on span. This error can be corrected by adjusting Zero.
Mass{weight}:
Transmitter approximately 3.4kg without
options.
Type
Range and overrange limit:
Range limit [kPa]
Lower limit
Permissible
negative
pressure limit
Upper limit
130
500
3000
10000
50000
Overrange limit
[MPa]
1
1.5
9
15
75
Process temperature and negative pressure tolerance limit:
(For details, see Fig. 1)
6
Y, G, N
W, A, D
R
Negative pressure
tolerance limit
2.7 kPa abs
Atmospheric pressure
2.7 kPa abs
(
)
(
)
Static pressure, range limit:
Pressure Transmitter : FDG
01
02
03
04
05
Silicone oil
Fluorinated oil
Silicone oil
Process
temperatuer
–40 to +100°C
–20 to +80°C
–15 to +100°C
Pressure Transmitter
Hydroseal Diaphragm version: FDG
Mounting position effect:
Zero shift, less than 0.12kPa for a 10° tilt
in any plane.
No effect on span.
This error can be corrected by adjusting
Zero.
Mass{weight}:
Transmitter approximately 4.4kg without
options.
F DG
F DG
F DG
F DG
F DG
13th code
–0.2% /10MPa{100bar}
Overrange effect:
Type
Filled oil
Static
pressure
[MPa]
FDG 07
–0.1 to 0.5
FDG 08
–0.1 to 3
FDG 09
–0.1 to 10
Range limit [kPa]
Lower limit
Upper limit
Permissible
negative
pressure
limit
Over range
limit [MPa]
500
1.5
3000
9
10000
15
Process temperature and negative pressure tolerance limit:
(For details, see Fig. 1)
Filled oil
13th code
Silicone oil
Fluorinated oil
Y, G, N
W, A, D
Process
temperatuer
–20 to +100°C
–20 to +80°C
Negative pressure
tolerance limit
2.7 kPa abs
Atmospheric pressure
Lower limit of static pressure (vacuum limit):
Silicone oil filled sensor:
See Fig. 1
Fluorinated oil filled sensor: 66kPa abs (500mmHg abs)
at temperature below 60°C
Accuracy rating: (including linearity, hysteresis, and repeatability)
Reference conditions, silicone oil fill,
316SS isolating diaphragms.
For spans greater than 1/10 of URL: ± 0.15% of span
For spans below 1/10 of URL:
0.1 x URL
± 0.1+0.05
% of span
Span
(
)
± 0.15% of upper range limit (URL) for 3
years
Temperature effect:
Effects per 28°C change between the
limits of – 40°C and +85°C
Zero shift: ± 0.2%
Total effect: ± 0.225%
Overrange effect: Zero shift; 0.4% of URL for any overrange
to maximum limit
Mounting position effect:
Zero shift, less than 0.1kPa for a 10° tilt in
any plane.
No effect on span. This error can be corrected by adjusting Zero.
Mass {weight}:
Transmitter approximately 3.4kg without
options.
Stability:
Absolute Pressure Transmitter : FDA
Range and overrange limit:
Type
F DA
F DA
F DA
F DA
Range limit [kPa abs]
01
02
03
04
0
0
0
0
to
to
to
to
+16
+130
+500
+3000
Overrange limit [MPa]
0.5
0.5
1.5
9
Process temperature and negative pressure tolerance limit:
Process temperature; –40 to +85°C
Negative pressure; Depends on measuring range.
Accuracy rating: (including linearity, hysteresis, and repeatability).
Reference conditions, silicone oil fill,
316SS isolating diaphragms.
(Standard)
For spans greater than 1/10 of URL: ± 0.2% of span
For spans below 1/10 of URL:
0.1 × URL
± 0.1+0.1
% of span
Span
(Option) (code: 21th digit H)
(Not available for Max span 16kPa abs, 130kPa abs)
For spans greater than 1/10 of URL: ± 0.1% of span
For spans below 1/10 of URL:
0.1 × URL
± 0.05+0.05
% of span
Span
Stability:
± 0.2% of upper range limit (URL) for 3
years
Temperature effect:
Effect per 28°C change between the limits of – 40°C and +85°C
Zero shift: ± 0.225%
Total effect: ± 0.25%
Overrange effect: Zero shift; ± 0.2% of URL for any
overrange to maximum limit
Mounting position effect:
Zero shift, less than 0.1kPa for a 10° tilt
in any plane.
No effect on span. This error can be corrected by adjusting zero.
Mass{weight}:
Transmitter approximately 3.4kg without
options.
(
(
)
)
Level Transmitter : FDE
F DE
F DE
F DE
Static pressure
3
5
6

 Up to flange rating

Filled oil
13th code
Fluorinated oil
Silicone oil
W, A, D
H
J
Y, G
S
T
K
Process
temperatuer
–20 to +120°C
–15 to +250°C
85 to +300°C
–40 to +120°C
–15 to +250°C
85 to +300°C
–15 to +150°C
Negative pressure
tolerance limit
Atmospheric pressure
2.7 kPa abs
0.13 kPa abs
Low pressure side contact liquid temperature on transmitter of Code “H, J,
S, T” is 120°C or lower. Low pressure side contact liquid temperature of
Code “K” is 85°C or lower.
Lower limit of static pressure (vacuum limit):
Silicone oil filled sensor:
See Fig. 1
Fluorinated oil filled sensor: 66kPa abs (500mmHg abs)
at temperature below 60°C
Accuracy rating: (including linearity, hysteresis, and repeatability)
Reference conditions, silicone oil fill,
316SS isolating diaphragms.
(Standard)
For spans greater than 1/10 of URL: ± 0.2% of span
For spans below 1/10 of URL:
0.1 × URL
± 0.1+0.1
% of span
Span
(Option) (Code: 21th digit H, K)
For span greater than 1/10 of URL: 0.1% of span
For span below 1/10 of URL:
0.1 × URL
± 0.05+0.05
% of span
Span
Stability:
± 0.2% of upper range limit (URL) for 3
years
Temperature effect:
Effects per 28°C change between the
limits of – 40°C and + 85°C
(Standard)
Zero shift: ± 0.35% of URL
Total effect: ± 0.5% of URL
(Option) (Code: 21th digit J, K)
Zero shift: ± 0.3% of URL
Total effect: ± 0.4% of URL
Static pressure effect:
Zero shift: ± 0.2% of URL / 1MPa
Span shift: – 0.2% of calibrated span /
1MPa
Overrange effect: Zero shift; ± 0.1% of URL for flange rating pressure
Mounting position effect:
Zero shift, less than 0.3kPa for a 10° tilt
in any plane. (No extension)
No effect on span.
This error can be corrected by adjusting
zero.
Mass{weight}:
Transmitter approximately 13kg without
options.
(
(
)
)
Remote Seal Type
Diffential Pressure / Flow Transmitter: FDD
Static pressure, range limit:
Type
Static pressure, range limit:
Type
Over range limit: To maximum static pressure limit
Process temperature and negative pressure tolerance limit:
(For details, see Fig. 2, Fig. 3)
Range limit [kPa]
+/– 32
+/– 130
+/– 500
F DD
F DD
F DD
Static pressure
3
5
6

 Up to flange rating

Range limit [kPa]
+/– 32
+/– 130
+/– 500
7
Filled oil
13th code
Fluorinated oil
Silicone oil
W, A, D
H
J
Y, G
S
T
K
Process
temperatuer
–20 to +120°C
–15 to +250°C
+85 to +300°C
–40 to +120°C
–15 to +250°C
+85 to +300°C
–15 to +200°C
Negative pressure
tolerance limit
Atmospheric pressure
2.7 kPa abs
0.13 kPa abs
Accuracy rating: (including linearity, hysteresis, and repeatability)
Reference conditions, silicone oil fill,
316SS isolating diaphragms.
(Standard)
For spans greater than 1/10 of URL: 0.2% of span
For spans below 1/10 of URL:
0.1 × URL
± 0.1+0.1
% of span
Span
(Option) (Code; 21th digit H,K)
For spans greater than 1/10 of URL: 0.1% of span
For spans below 1/10 of URL:
0.1 × URL
± 0.05+0.05
% of span
Span
Stability:
± 0.2% of upper range limit (URL) for 3
years
Temperature effect (*):
Effects per 28°C change between the
limits of – 40°C and +85°C
(Standard)
Zero shift: ± 0.35% of URL
Total effect: ± 0.5% of URL
(Option) (Code; 21th digit J,K)
Zero shift: ± 0.3% of URL
Total effect: ± 0.4% of URL
(
)
(
)
Note: * Excluding effect by temperature difference
between the seals.
Static pressure effect:
Zero shift; 0.2% of URL for flange rating
pressure
Span shift: – 0.2% of calibrated span for
flange rating pressure
Overrange effect: Zero shift; 0.1% of URL for flange rating
pressure
Mass {weight}:
Transmitter approximately 15kg without
options.
Remote Seal Type
Pressure Transmitter: FDB
Range, and overrange limit:
Type
F DB
F DB
F DB
F DB
F DB
Range limit [kPa]
1
2
3
4
5
–100
–100
–100
–100
–100
to
to
to
to
to
+130
+500
+3000
+10000
+50000
Overrange limit [MPa]
1
1.5
9
15
75
Process temperature and negative pressure tolerance limit:
(For details, see Fig. 2, Fig. 4)
8
Filled oil
13th code
Fluorinated oil
Silicone oil
W, A, D
H
J
Y, G
S
T
K
Process
temperatuer
–20 to +120°C
–15 to +250°C
85 to +300°C
–40 to +120°C
–15 to +250°C
85 to +300°C
–15 to +200°C
Negative pressure
tolerance limit
Atmospheric pressure
2.7 kPa abs
0.13 kPa abs
Accuracy rating: (including linearity, hysteresis, and repeatability)
Reference conditions, silicone oil fill,
316SS isolating diaphragms.
(Standard)
For spans greater than 1/10 of URL: ± 0.2% of span
For spans below 1/10 of URL:
0.1 × URL
± 0.1+0.1
% of span
Span
(Option) (Code; 21th digit H,K)
Not available for Max span 50000kPa model.
For spans greater than 1/10 of URL: ± 0.1% of span
For spans below 1/10 of URL:
0.1 × URL
± 0.05+0.05
% of span
Span
(
(
)
)
± 0.1% of upper range limit (URL) for 3
years
Temperature effect:
Effect per 28°C change between the limits of – 40°C and +85°C
(Standard)
Zero shift: ± 0.35% of URL
Total effect: ± 0.5% of URL
(Option) (Code; 21th digit J,K)
Zero shift: ± 0.3% of URL
Total effect: ± 0.4% of URL
Overrange effect: Zero shift; 0.2% of URL for any overrange
to maximum limit
Mass {weight}:
Transmitter approximately 10kg without
options.
Stability:
Small Frange Level Transmitter : FDY
Static pressure, range limit:
Type
Static pressure
FDY
5
FDY
6



Over range limit: To maximum static pressure limit
Process temperature and negative pressure tolerance limit:
(For details, see Fig. 2, Fig. 4)
Up to flange rating
Range limit [kPa]
+/– 130
+/– 500
Over range limit: To maximum static pressure limit
Process temperature and negative pressure tolerance limit:
(For details, see Fig. 2)
Filled oil
13th code
Process
Negative pressure
temperatuer
tolerance limit
Fluorinated oil
W, A, D
–20 to +80°C
Atmospheric pressure
Silicone oil
H
0 to +250°C
Y, G
–40 to +120°C
2.7 kPa abs
S
0 to +250°C
Low pressure side contact liquid temperature on transmitter of Code “H,
S” is 120°C or lower.
Lower limit of static pressure (vacuum limit):
Silicone oil filled sensor:
See Fig. 1
Fluorinated oil filled sensor: 66kPa abs (500mmHg abs)
at temperature below 60°C
Accuracy rating: (including linearity, hysteresis, and repeatability)
Reference conditions, silicone oil fill,
316SS isolating diaphragms.
(Standard)
For spans greater than 1/10 of URL: ± 0.25% of span
For spans below 1/10 of URL:
0.1 x URL
± 0.17+0.08
% of span
Span
(Option) (Code: 21th digit H, K)
For spans greater than 1/10 of URL: ± 0.1% of span
For span below 1/10 of URL:
0.1 x URL
± 0.05+0.05
% of span
Span
(
)
(
)
± 0.2% of upper range limit (URL) for 3
years
Temperature effect:
Effects per 28°C change between the
limits of – 15°C and + 65°C
Zero shift; ± 0.5%
Total shift; ± 0.75%
(Option) (Code: 21th digit J, K)
Zero shift; ± 0.5%
Total shift; ± 0.75%
Stability:
Where, URL:
Maximum span (Upper Range
Limit)
Static pressure effect:
Zero shift: ± 0.2% of URL/1MPa
Span shift: –0.2% of calibrated span
/1MPa
Overrange effect:Zero shift; ± 0.1% of URL for flange rating pressure
Mass{weight}:
Transmitter approximately 13kg without
options.
Small Frange Remote Seal Type
Differential Pressure Transmitter: FDX
Static pressure, range limit:
Type
Static pressure
FDX
5
FDX
6
} Up tp flange rating
Range limit [kPa]
+/– 130
+/– 500
Over range limit: To maximum static pressure limit
Process temperature and negative pressure tolerance limit:
(For details, see Fig. 2, Fig. 4)
Filled oil
13th code
Fluorinated oil
Silicone oil
W, A, D
H
Y, G
S
Process
temperatuer
–20 to +120°C
0 to +250°C
–40 to +120°C
0 to +250°C
Negative pressure
tolerance limit
Atmospheric pressure
2.7 kPa abs
Accuracy rating: (including linearity, hysteresis, and repeatability)
Reference conditions, silicone oil fill,
316SS isolating diaphragms.
(Standard)
For spans greater than 1/10 of URL: 0.25% of span
For spans below 1/10 of URL:
0.1 x URL
± 0.17+0.08
% of span
Span
(
)
(Option) (Code; 21th digit H,K)
For spans greater than 1/10 of URL: 0.1% of span
For spans below 1/10 of URL:
0.1 x URL
± 0.05+0.05
% of span
Span
Stability:
± 0.2% of upper range limit (URL) for 3
years
Temperature effect:
Effects per 28°C change between the
limits of – 15°C and +65°C
Zero shift: ± 0.5%
Total shift; ± 0.75%
(option) (Code; 21th digit J,K)
Zero shift: ±0.5
Total shift; ± 0.75%
(
Where,
)
Static pressure effect:
Zero shift; 0.2% of URL/1MPa (10 bar)
Span shift: – 0.2% of calibrated span /
1MPa
Overrange effect: Zero shift; 0.1% of URL for flange nominal pressure
Mass {weight}:
Transmitter approximately 15kg without
options.
Small Frange Remote Seal Type
Pressure Transmitter: FDW
Range, and overrange limit:
Type
Range limit [kPa]
Overrange limit [MPa]
FDW
3
–100 to +3000
4.5
FDW
4
–100 to 10000
15
Process temperature and negative pressure tolerance limit:
(For details, see Fig. 2)
Filled oil
13th code
Fluorinated oil
Silicone oil
W, A, D
H
Y, G
S
Process
temperatuer
–20 to +120°C
0 to +250°C
–40 to +120°C
0 to +250°C
Negative pressure
tolerance limit
Atmospheric pressure
2.7 kPa abs
Accuracy rating: (including linearity, hysteresis, and repeatability)
Reference conditions, silicone oil fill,
SS316 isolating diaphragms.
(Standard)
For spans greater than 1/10 of URL: ± 0.25% of span
For spans below 1/10 of URL:
± 0.17+0.08 0.1 x URL % of span
Span
(Option) (Code; 21th digit H)
For spans greater than 1/10 of URL: ± 0.1% of span
For spans below 1/10 of URL:
± 0.05+0.05 0.1 x URL % of span
Span
Stability:
± 0.2% of upper range limit (URL) for 3
years
Temperature effect:
Effect per 28°C change between the limits of – 15°C and +65°C
Zero shift: ± 0.5%
Total shift; ± 0.75%
(
)
(
)
Where,
URL:
Maximum span (Upper Range
Limit)
Note : Above specifications are based on the conditions that flange and sensor unit are at
the same temperature and in the same
level. If temperature is different at flange,
capillary or sensor unit, output variation
may increase.
Overrange effect: Zero shift; 0.2% of URL/(1.5 x URL)
Mass {weight}:
Transmitter approximately 10kg without
options.
URL:
Maximum span (Upper Range
Limit)
Note : Above specifications are based on the conditions that flanges and sensor unit are at
the same temperature and in the same
level. If temperature is different at flanges,
capillary or sensor unit, output variation
may increase.
9
Silicone oil (Code:Y,G,N)
Silicone oil (Code:R)
[kPa abs]
{mbar abs}
[kPa abs]
Sealing liquid:Silicone (Code K)
101
Operating
area
Operating pressure
Operating pressure
101
{1010}
20
4
Operating arear
Non-operating area
2.7
None-operating
area
–40
–15
0.13
{1.3}
60 85 120
–15
Process temperature[°C ]
100
Process temperature[°C ]
Fig. 1 Relation between process temperature
and operating pressure (pressure and
differential pressure/flow transmitters)
Fig. 3 Relation between process temperature
and operating pressure (level transmitters)
Filled fluid: Silicone oil (code Y, G)
[kPa abs]
Filled fluid: Silicone oil (code S)
[kPa abs]
Filled fluid: Silicone oil (code K)
Filled fluid: Silicone oil (code T)
Operating pressure
Operating pressure
101
53.3
Operating area
13.3
2.7
60 85 120
200 230250
Process temperature
Fig. 2 Relation between process temperature
and operating pressure (remote seal type
pressure, remote seal type differential
pressure and level transmitters)
10
Operating area
Nonoperating
area
0.27
Non-operating area
–40 –15
101
0.13
300
[°C]
–15
100
Process temperature
200
[°C]
Fig. 4 Relation between process temperature
and operating pressure (remote seal type
pressure, remote seal type differential
pressure and level transmitters)
CODE SYMBOLS
Diffential pressure / flow transmitter : FDC
1 2 3 4 5 6 7 8
Digit
4
Note
Description
<Connection>
Oval flange
Conduit
Process
connection
connection screw
7/16-20UNF
(×1)
G1/2
Rc1/4
7/16-20UNF
1/2-14NPT (×1)
1/4-18NPT
Combination with 12th
1/4-18NPT
digit code “C, E, P, Q”
M10 (or M12)(*1) Pg 13.5
(×1)
are not available.
1/4-18NPT
M10 (or M12)(*1) M20×1.5 (×1)
7/16-20UNF
1/4-18NPT
Pg 13.5
(×1)
7/16-20UNF
(×2)
G1/2
Rc1/4
7/16-20UNF
1/2-14NPT (×2)
1/4-18NPT
1/4-18NPT
M10 (or M12)(*1) Pg 13.5
(×2)
1/4-18NPT
M10 (or M12)(*1) M20×1.5 (×2)
7/16-20UNF
1/4-18NPT
Pg 13.5
(×2)
5, 6, 7 <Span and materials>
Static
Wetted
Span limit (*2) Process
Diaphragm
pressure
cover
cell body
[MPa]
[kPa]
–0.1 to
+3.2
0.1…1
–0.1 to+10 0.1…6
–0.1 to+16 0.32…32
1.3…130
5…500
30…3000
–0.1 to+42 0.32…32
1.3…130
5…500
–0.1 to+30 30…3000
–0.1 to+10 0.32…32
1.3…130
5…500
–0.1 to+16 3.2…32
13…130
316 stainless steel 316L stainless steel
316 stainless steel 316L stainless steel
+Au coating
316 stainless steel Hast. C
316 stainless steel 316L stainless steel
316 stainless steel 316L stainless steel
+Au coating
316 stainless steel Hast. C
316 stainless steel 316L stainless steel
316 stainless steel 316L stainless steel
+Au coating
316 stainless steel Hast. C
316 stainless steel Monel
316 stainless steel Tantalum
316 stainless steel 316L stainless steel
316 stainless steel 316L stainless steel
+Au coating
316 stainless steel Hast. C
316 stainless steel Monel
316 stainless steel Tantalum
316 stainless steel 316L stainless steel
316 stainless steel 316L stainless steel
+Au coating
316 stainless steel Hast. C
316 stainless steel Monel
316 stainless steel Tantalum
316 stainless steel 316L stainless steel
316 stainless steel 316L stainless steel
+Au coating
316 stainless steel 316L stainless steel
316 stainless steel 316L stainless steel
+Au coating
316 stainless steel Hast. C
316 stainless steel Monel
316 stainless steel 316L stainless steel
316 stainless steel 316L stainless steel
+Au coating
316 stainless steel Hast. C
316 stainless steel Monel
316 stainless steel 316L stainless steel
316 stainless steel 316L stainless steel
+Au coating
316 stainless steel Hast. C
316 stainless steel Monel
316 stainless steel 316L stainless steel
316 stainless steel 316L stainless steel
+Au coating
Hast. C
Hast. C lining
Monel
Monel lining
Tantalum lining Tantalum
Hast. C
Hast. C lining
Monel
Monel lining
Tantalum lining Tantalum
Hast. C
Hast. C lining
Monel
Monel lining
Tantalum lining Tantalum
316 stainless steel 316L stainless steel
(*3)
316 stainless steel 316L stainless steel
(*3)
Note 1
Note 1
Note 1
Note 1
FDC
4
9 10 11 12 13
14 15
Digit No.
of code
A
B
C
D
E
S
T
V
W
X
Note 2
316 stainless steel
316 stainless steel
11V
11J
Hast. C lining
316 stainless steel
316 stainless steel
11H
22V
22J
Hast. C lining
316 stainless steel
316 stainless steel
22H
33V
33J
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
316 stainless steel
33H
33M
33T
35V
35J
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
316 stainless steel
35H
35M
35T
36V
36J
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
316 stainless steel
36H
36M
36T
38V
38J
316 stainless steel
316 stainless steel
43V
43J
Hast. C lining
Monel lining
316 stainless steel
316 stainless steel
43H
43M
45V
45J
Hast. C lining
Monel lining
316 stainless steel
316 stainless steel
45H
45M
46V
46J
Hast. C lining
Monel lining
316 stainless steel
316 stainless steel
46H
46M
48V
48J
Hast. C lining
Monel lining
Tantalum lining
Hast. C lining
Monel lining
Tantalum lining
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel Note 3
23B
23L
23U
25B
25L
25U
26B
26L
26U
33C
316 stainless steel Note 3
35C
11
1 2 3 4 5 6 7 8
Digit
9
10
11
12
13
14
15
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Description
<Digital indicator, arrester and communication>
Digital indicator
Arrester
Communication type
None
None
Foundation Fieldbus
None
Yes
Foundation Fieldbus
Yes
None
Foundation Fieldbus
Yes
Yes
Foundation Fieldbus
Note
FDC
9 10 11 12 13
R
V
T
W
None (for ordinary locations)
A
TIIS, Flameproof (Conduit seal)
TIIS, Flameproof (Cable gland seal)
FM, Flameproof (or explosionproof)
CSA, Flameproof (or explosionproof)
ATEX, Flameproof
B
C
D
E
X
Approval pending
ATEX, Intrinsic safty (Entity)
SAA, Flameproof (or explosionproof)
Approval pending
Approval pending
K
F
ATEX, FISCO
Approval pending
Note 9
4
A
C
D
F
Note 4
Y
B
C
E
M
N
P
Q
Y
W
G
A
D
N
R
A
B
Note 8
Note 5
Note 6
Note 7
A
B
C
D
E
F
The thread is M12, if 42MPa {420bar} static pressure is specified.
100: 1 turn down is possible, but should be used at the span greater than 1/40 of the maximum span for better performance.
The diaphragm face is coated with gold and ceramic.
Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”.
Static pressure should be –0.1 to +10MPa{–1 to +100bar}.
Available for 5th digit code “1”, “2”, “3”. In case of stainless steel bolt with 5th digit code “3”, static pressure should be
–0.1 to +10MPa {–1 to + 100bar}.
Note 7: (*7) Available for 5th digit code “3”, “4”.
Note 8: (*8) In case of tropical use, select stainless bolts and nuts.
Note 9: (*9) In case of 10th code is “4”(ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available.
12
(*1)
(*2)
(*3)
(*4)
(*5)
(*6)
Digit No.
of code
A
E
P
S
None
None
Profibus
None
Yes
Profibus
Yes
None
Profibus
Yes
Yes
Profibus
<Approvals for hazardous, for fieldbus>
<Vent/ drain and mounting bracket>
Vent/drain
Mounting bracket
Specify “A” or “C” for the 7th
Standard
None
Standard
Yes, stainless steel digit code “B”, “L”, or “U”
Side
None
Side
Yes, stainless steel
<Options>
Extra SS tag plate
Stainless steel elec, housing
Coating of cell
None
None
None
Yes
None
None
None
Yes
None
Yes
Yes
None
(*4)
None
None
Yes
Yes
None
Yes
None
Yes
Yes
Yes
Yes
Yes
<Special applications and fill fluid>
Treatment
Fill fluid
Standard
Silicone oil
Standard
Fluorinated oil
Degreasing
Silicone oil
Oxygen service Fluorinated oil (7th digit code “V” only)
Chlorine service Fluorinated oil (7th digit code “H”, “T”, “B”, “U”)
NACE specification Silicone oil (Not available for 7th digit code “T”, “U” and 15th digit code “A”, “B”)
Vacuum service Silicone oil for vacuum use (Not available for 7th digit code “C”)
<Sensor O-ring / Gasket>
Viton (O-ring)
Teflon (gasket)
<Bolt/nut> (*8)
Cr-Mo alloy hexagon socket head cap screw/carbon steel nut
Cr-Mo alloy hexagon bolt/nut
NACE bolt/nut (ASTM A193 B7M/A194 2HM)
(*5)
NACE bolt/nut (ASTM A320 L7M/A194 2HM)
304 stainless steel bolt/304 stainless steel nut (*6)
630 stainless steel bolt/304 stainless steel nut (*7)
14 15
4
Pressure transmitter : FDG
1 2 3 4 5 6 7 8
Digit
4
6, 7
<Connections>
Oval flange
Process
screw
connection
7/16-20UNF
Rc1/4
1/4-18NPT
7/16-20UNF
1/4-18NPT
M10 (or M12)(*1)
1/4-18NPT
M10 (or M12)(*1)
1/4-18NPT
7/16-20UNF
7/16-20UNF
Rc1/4
1/4-18NPT
7/16-20UNF
1/4-18NPT
M10 (or M12)(*1)
1/4-18NPT
M10 (or M12)(*1)
1/4-18NPT
7/16-20UNF
<Span and materials>
Span limit
Process cover
[kPa](*2)
316 stainless steel
1.3…130
316 stainless steel
5…500
30…3000
100…10000
500…50000
50…500
300…3000
1000…10000
9
Note
Description
316 stainless steel
316 stainless steel
316 stainless steel
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
Conduit
connection
G1/2
1/2-14NPT
Pg13.5
M20×1.5
Pg13.5
G1/2
1/2-14NPT
Pg13.5
M20×1.5
Pg13.5
(×1)
(×1)
(×1)
(×1)
(×1)
(×2)
(×2)
(×2)
(×2)
(×2)
Combination with
12th digit code
Note 1
“C, E, P, Q” are
Note 1
not available.
Note 1
Note 1
F DG
0
9 10 11 12 13
4
Digit No.
of code
A
B
C
D
E
S
T
V
W
X
Diaphragm
Wetted cell body
316L stainless steel
316L stainless steel
+Au Coating
Hast. C
Monel
Tantalum
Hast. C
Monel
Tantalum
316L stainless steel
316L stainless steel
+Au Coating
Hast. C
Monel
Tantalum
Hast. C
Monel
Tantalum
316L stainless steel
316L stainless steel
+Au Coating
Hast. C
Monel
Tantalum
Hast. C
Monel
Tantalum
316L stainless steel
316L stainless steel
+Au Coating
Hast. C
Monel
Tantalum
Hast. C
Monel
Tantalum
316L stainless steel
316L stainless steel
316L stainless steel
316L stainless steel
316 stainless steel
316 stainless steel
1V
1J
Hast. C lining
Monel lining
Tantalum lining
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
316 stainless steel
1H
1M
1T
1B
1L
1U
2V
2J
Hast. C lining
Monel lining
Tantalum lining
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
316 stainless steel
2H
2M
2T
2B
2L
2U
3V
3J
Hast. C lining
Monel lining
Tantalum lining
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
316 stainless steel
3H
3M
3T
3B
3L
3U
4V
4J
Hast. C lining
Monel lining
Tantalum lining
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
4H
4M
4T
4B
4L
4U
5V
7C
8C
9C
Note 2
<Digital indicator, arrester and communication>
Digital indicator
Arrester
Communication type
None
None
Foundation Fieldbus
None
Yes
Foundation Fieldbus
Yes
None
Foundation Fieldbus
Yes
Yes
Foundation Fieldbus
A
E
P
S
None
None
Yes
Yes
R
V
T
W
None
Yes
None
Yes
14 15
Profibus
Profibus
Profibus
Profibus
13
1 2 3 4 5 6 7 8
Digit
10
11
12
13
14
15
Description
<Approvals for hazardous, for fieldbus>
F DG
0
9 10 11 12 13
A
TIIS, Flameproof (Conduit seal)
TIIS, Flameproof (Cable gland seal)
FM, Flameproof (or explosionproof)
CSA, Flameproof (or explosionproof)
ATEX, Flameproof
B
C
D
E
X
Approval pending
ATEX, Intrinsic safty (Entity)
SAA, Flameproof (or explosionproof)
Approval pending
Approval pending
K
F
ATEX, FISCO
Approval pending
Note5
4
<Vent/ drain and mounting bracket>
Vent/drain
Mounting bracket
Standard
None
Specify “A”, or “C” for the 7th
Standard
Yes, stainless steel digit code “B”, “L”, or “U”
Side
None
Side
Yes, stainless steel
<Options>
Extra SS tag plate
Stainless steel elec. housing
Coating of cell
None
None
None
Yes
None
None
None
Yes
None
Note3
(*3)
Yes
Yes
None
None
None
Yes
Yes
None
Yes
None
Yes
Yes
Yes
Yes
Yes
<Special applications and fill fluid>
Treatment
Fill fluid
Standard
Silicone oil
Standard
Fluorinated oil
Degreasing
Silicone oil
Oxygen service
Fluorinated oil (7th digit code “V” only)
Chlorine service
Fluorinated oil (7th digit code “H”, “T”, “B”, “U”)
NACE specification
Silicone oil (Not available for 6th digit code “5”, 7th
digit code “T”, “U”, 15th digit code “A”, “B”)
Vacuum service
Silicone oil for vacuum use(Not available for 7th
digit code “C”)
<Sensor O-ring / Gasket>
Viton (O-ring)
Teflon (gasket)
<Bolt/nut> (*4)
Note4
Cr-Mo alloy hexagon socket head cap screw/carbon steel nut
Cr-Mo alloy hexagon bolt/nut
NACE bolt/nut (ASTM A193 B7M/A194 2HM)
Not available for 6th digit
NACE bolt/nut (ASTM A320 L7M/A194 2HM)
code “5”
304 stainless steel bolt/304 stainless steel nut
630 stainless steel bolt/304 stainless steel nut Available for 6th digit code “5”
14 15
4
None (for ordinary locations)
Note 1 : (*1)
Note 2 : (*2)
Note 3 : (*3)
Note 4 : (*4)
Note 5: (*5)
14
Note
Digit No.
of code
A
C
D
F
Y
B
C
E
M
N
P
Q
Y
W
G
A
D
N
R
A
B
A
B
C
D
E
F
For 50MPa {500bar} units, M12 is provided rather than M10.
100: 1 turn down is possible, but should be used at the span greater than 1/40 of the maximum span for better performance.
Costomer tag number can be engraved on standartd stainless steel name plate. If extra tag plate is required, select “Yes”.
In case of tropical use, select stainless bolts and nuts.
In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available.
Absolute pressure transmitter : FDA
1 2 3 4 5 6 7 8
Digit
4
6, 7
Description
<Connections>
Process
connection
Rc1/4
1/4-18NPT
1/4-18NPT
1/4-18NPT
1/4-18NPT
Rc1/4
1/4-18NPT
1/4-18NPT
1/4-18NPT
1/4-18NPT
<Span limit>
Span limit
[kPa abs](*1)
1.6…16
1.6…130
5…500
30…3000
9
10
11
12
Note
Oval flange
screw
7/16-20UNF
7/16-20UNF
M10
M10
7/16-20UNF
7/16-20UNF
7/16-20UNF
M10
M10
7/16-20UNF
Conduit
connection
G1/2
1/2-14NPT
Pg 13.5
M20×1.5
Pg 13.5
G1/2
1/2-14NPT
Pg 13.5
M20×1.5
Pg 13.5
Process cover
Diaphragm
Wetted cell body
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
316L stainless steel
Hast. C
Monel
316L stainless steel
Hast. C
Monel
Tantalum
316L stainless steel
Hast. C
Monel
Tantalum
316L stainless steel
Hast. C
Monel
Tantalum
316 stainless steel
Hast. C lining
Monel lining
316 stainless steel
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
Hast. C lining
Monel lining
Tantalum lining
316 stainless steel
Hast. C lining
Monel lining
Tantalum lining
(×1)
(×1)
(×1)
(×1)
(×1)
(×2)
(×2)
(×2)
(×2)
(×2)
FDA
0
9 10 11 12 13
4
14 15
21
Digit No.
of code
A
B
C
D
E
S
T
V
W
X
Combination with
12th digit code
“C, E, P, Q” are
not available.
Note1
1V
1H
1M
2V
2H
2M
2T
3V
3H
3M
3T
4V
4H
4M
4T
<Digital indicator, arrester and communication>
Digital indicator
Arrester
Communication type
None
None
Foundation Fieldbus
None
Yes
Foundation Fieldbus
Yes
None
Foundation Fieldbus
Yes
Yes
Foundation Fieldbus
A
E
P
S
None
None
Profibus
None
Yes
Profibus
Yes
None
Profibus
Yes
Yes
Profibus
<Approvals for hazardous, for fieldbus>
R
V
T
W
None (for ordinary locations)
A
TIIS, Flameproof (Conduit seal)
TIIS, Flameproof (Cable gland seal)
FM, Flameproof (or explosionproof)
CSA, Flameproof (or explosionproof)
ATEX, Flameproof
B
C
D
E
X
Approval pending
ATEX, Intrinsic safty (Entity)
SAA, Flameproof (or explosionproof)
Approval pending
Approval pending
K
F
ATEX, FISCO
Approval pending
Note4
4
<Vent/ drain and mounting bracket>
Vent/drain
Mounting bracket
Standard
None
Standard
Yes, stainless steel
Side
None
Side
Yes, stainless steel
<Options>
Extra SS tag plate
Stainless steel elec. housing
None
None
Yes
None
None
Yes
(*2)
Yes
Yes
None
None
Yes
None
None
Yes
Yes
Yes
A
C
D
F
Coating of cell
None
None
None
None
Yes
Yes
Yes
Yes
Note2
Y
B
C
E
M
N
P
Q
15
1 2 3 4 5 6 7 8
Digit
13
14
15
21
Note 1:
Note 2:
Note 3:
Note 4:
16
Description
Note
<Special applications and fill fluid>
Treatment
Fill fluid
Standard
Silicone oil
Degreasing
Silicone oil
NACE specification
Silicone oil (7th digit code “T” and 15th digit code
“A”, “B” are not available)
<Sensor O-ring>
Viton
Note 3
<Bolt/nut> (*3)
Cr-Mo alloy hexagon socket head cap screw/carbon steel nut
Cr-Mo alloy hexagon bolt/nut
NACE bolt/nut (ASTM A193 B7M/A194 2HM)
NACE bolt/nut (ASTM A320 L7M/A194 2HM)
304 stainless steel bolt/304 stainless steel nut
<Other options>
High accuracy type
(*1)
(*2)
(*3)
(*4)
FDA
0
9 10 11 12 13
14 15
21
4
Y
G
N
A
A
B
C
D
E
H
100: 1 turn down is possible, but should be used at a span greater than 1/40 of the maximum span for better performance.
Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”.
In case of tropical use, select stainless bolts and nuts.
In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available.
Digit No.
of code
Level transmitter : FDE
1 2 3 4 5 6 7 8
Digit
4
5
6
7
9
Description
<Connections>
Process
connection
Rc1/4
1/4-18NPT
1/4-18NPT
1/4-18NPT
1/4-18NPT
Rc1/4
1/4-18NPT
1/4-18NPT
1/4-18NPT
1/4-18NPT
Oval flange
screw
7/16-20UNF
7/16-20UNF
M10
M10
7/16-20UNF
7/16-20UNF
7/16-20UNF
M10
M10
7/16-20UNF
Conduit
connection
(×1)
G 1/2
1/2-14NPT (×1)
Pg13.5
(×1)
M20×1.5 (×1)
Pg13.5
(×1)
(×2)
G 1/2
1/2-14NPT (×2)
Pg13.5
(×2)
M20×1.5 (×2)
Pg13.5
(×2)
Note
Hastelloy-C lining
316 stainless steel Hastelloy-C
Monel lining
316 stainless steel Monel
Tantalum lining
316 stainless steel Tantalum
Hastelloy-C lining
Hastelloy-C lining Hastelloy-C
Monel lining
Monel
Monel lining
Tantalum lining
Tantalum
Tantalum lining
316 stainless steel 316 stainless steel 316 stainless steel
316 stainless steel 316 stainless steel 316 stainless steel
<Digital indicator, arrester and communication>
Digital indicator
Arrester
Communication type
None
None
Foundation Fieldbus
None
Yes
Foundation Fieldbus
Yes
None
Foundation Fieldbus
Yes
Yes
Foundation Fieldbus
None
None
Yes
Yes
None
Yes
None
Yes
Profibus
Profibus
Profibus
Profibus
9 10 11 12 13
4
14 15
21
Digit No.
of code
A
B
C
D
E
S
T
V
W
X
Combination with 12th
digit code “C, E, P, Q”
are not available.
<Mounting flange>
Material
Size and rating
304 stainless
JIS 10K 80A
steel
JIS 10K 100A
JIS 30K 80A
JIS 30K 100A
ANSI/JPI 150LB 3"
ANSI/JPI 150LB 4"
ANSI/JPI 300LB 3"
ANSI/JPI 300LB 4"
DIN PN40 DN80
DIN PN16 DN100
JIS 20K 80A
ANSI/JPI 600LB 3"
Carbon steel
JIS 10K 80A
JIS 10K 100A
JIS 30K 80A
JIS 30K 100A
ANSI/JPI 150LB 3"
ANSI/JPI 150LB 4"
ANSI/JPI 300LB 3"
ANSI/JPI 300LB 4"
DIN PN40 DN80
DIN PN16 DN100
316 stainless
JIS 10K 80A
steel
ANSI/JPI 150LB 3B
ANSI/JPI 150LB 4B
ANSI/JPI 300LB 3B
ANSI/JPI 300LB 4B
ANSI/JPI 600LB 3B
<Span limit (*1) [kPa] >
0.32
32
1.3
130
5
500
<Material>
LP side
Wetted sensor
Diaphragm
Process cover
body
316 stainless steel 316 stainless steel 316 stainless steel
316 stainless steel 316 stainless steel 316 stainless steel
316 stainless steel 316 stainless steel 316 stainless steel
316 stainless steel 316 stainless steel 316 stainless steel
316 stainless steel 316 stainless steel 316 stainless steel
FDE
Note 1
0
1
2
3
4
5
6
7
8
9
M
R
A
B
C
D
E
F
G
H
J
K
S
T
U
V
W
X
3
5
6
HP side
Diaphragm and
flange face
316 stainless steel
Hastelloy-C
Monel
Tantalum
Diaphragm:
316L stainless steel
+Au coating
Flange face:
316 stainless steel
Hastelloy-C
Monel
Tantalum
Hastelloy-C
Monel
Tantalum
Note 3
Titanium
Note 2, 3
Zirconium
V
C
D
E
J
H
M
T
B
L
U
P
R
A
E
P
S
R
V
T
W
17
1 2 3 4 5 6 7 8
Digit
10
11
12
13
14
15
21
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
18
Description
<Approvals for hazardous, for fieldbus>
Note
FDE
9 10 11 12 13
None (for ordinary locations)
A
TIIS, Flameproof (Conduit seal)
TIIS, Flameproof (Cable gland seal)
FM, Flameproof (or explosionproof)
CSA, Flameproof (or explosionproof)
ATEX, Flameproof
B
C
D
E
X
Approval pending
ATEX, Intrinsic safty (Entity)
SAA, Flameproof (or explosionproof)
Approval pending
Approval pending
K
F
ATEX, FISCO
Approval pending
Note7
4
<Diaphragm extension [mm]>
Extension [mm]
Applicable material code
0
Any
50
100
(7th digit code “V“ only)
150
200
50
100
(7th digit code “C“, “H“, “B“, only)
150
200
<Options>
Extra SS tag plate
Stainless steel elec. housing
Coating of cell
None
None
None
Yes
None
None
None
Yes
None
Note 4
Yes
(* 4)
Yes
None
None
None
Yes
Yes
None
Yes
None
Yes
Yes
Yes
Yes
Yes
<Special applications and fill fluid>
Treatment
Fill fluid
Standard
Silicone oil
Standard
Fluorinated oil
Degreasing
Silicone oil
Fluorinated oil (7th digit code “V“ only)
Oxygen service
Fluorinated oil (7th digit code “C”, “E”, “H”, “T”, “B”, “U”)
Chlorine service
7th digit code “V”, “C”, “H”, “B”
High temp. 250°C
High temp. 300°C
(* 5) Note 5
High temp. and vacuum (250°C)
7th digit code “V”
High temp. and vacuum (300°C)
High temp. and high vacuum Silicone oil
<O-ring, gasket and Teflon membrane>
O-ring /Gasket
Teflon membrane
Viton (O-ring)
None
Teflon (gasket)
None
Viton (O-ring)
Yes (5th digit code “0”, “2”, “4”, “6”, “8”, “A”,
Teflon (gasket)
Yes “C”, “E”, “G”, “J”, “M”, “R”, “S”, “T”, “V”,
“X”, and 11th digit code “Y” are available.
13th digit code “H, J, S, T, K” are not available.)
Note 6
<Bolt/nut> (* 6)
Cr-Mo alloy hexagon socket head cap screw/carbon steel nut
Cr-Mo alloy hexagon bolt/nut
304 stainless steel bolt /304 stainless steel nut
<Other options>
High accuracy type
Low temperature effect type
H+J
(*1)
(*2)
(*3)
(*4)
(*5)
(*6)
(*7)
14 15
21
4
Y
A
B
C
D
E
F
G
H
Y
B
C
E
M
N
P
Q
Y
W
G
A
D
H
J
S
T
K
A
B
C
D
A
B
E
H
J
K
100: 1 turn down is possible, but should be used at a span greater than 1/40 of the maximum span for better performance.
Material Code R; 6th digit code “6” is not available.
5th digit code “0, 2, 4, 6, 8, A, C, E, G, J, P, M, R, S, T, V, X” are available.
Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”
Treatment; None
In case of tropical use, select stainless bolts and nuts.
In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available.
Digit No.
of code
Remote seal type differential pressure transmitter : FDD
1 2 3 4 5 6 7 8
Digit
4
5
6
7
9
Description
<Conduit connection>
(×1)
G 1/2
1/2-14NPT (×1)
Combination with 12th digit code
“C, E, P, Q” are not available.
Pg13.5
(×1)
M20 × 1.5 (×1)
(×2)
G 1/2
1/2-14NPT (×2)
Pg13.5
(×2)
M20 × 1.5 (×2)
<Flange>
Mounting flange
Flange size and rating
304 stainless
JIS 10K 80A
steel
JIS 10K 100A
JIS 30K 80A
JIS 30K 100A
ANSI/JPI 150LB 3"
ANSI/JPI 150LB 4"
ANSI/JPI 300LB 3"
ANSI/JPI 300LB 4"
DIN PN16/40 DN80
DIN PN16 DN100
JIS 20K 80A
ANSI/JPI 600LB 3"
Carbon steel
JIS 10K 80A
JIS 10K 100A
JIS 30K 80A
JIS 30K 100A
ANSI/JPI 150LB 3"
ANSI/JPI 150LB 4"
ANSI/JPI 300LB 3"
ANSI/JPI 300LB 4"
DIN PN16/40 DN80
DIN PN16 DN100
316 stainless
JIS 10K 80A
steel
ANSI/JPI 150LB 3"
ANSI/JPI 150LB 4"
ANSI/JPI 300LB 3"
ANSI/JPI 300LB 4"
ANSI/JPI 600LB 3"
None
3 inch wafer
(wafer type)
4 inch wafer
<Span limit (*1) [kPa]>
0.32.... 32
1.3...... 130
5......... 500
<Material/diaphragm extension>
Diaphragm
Flange face
Diaph. extension [mm]
316L stainless
316 stainless
0
steel
steel
50
100
(*2)
150
200
Hastelloy-C
Hastelloy-C
0
50
100
150
200
316L stainless
316 stainless
0
+Au coating
steel
Monel
Monel
0
Tantalum
Tantalum
0
Titanium
Titanium
0
(*3)
Zirconium
Zirconium
0
<Digital indicator, arrester and communication>
Digital indicator
Arrester
Communication type
None
None
Foundation Fieldbus
None
Yes
Foundation Fieldbus
Yes
None
Foundation Fieldbus
Yes
Yes
Foundation Fieldbus
None
None
Yes
Yes
None
Yes
None
Yes
Profibus
Profibus
Profibus
Profibus
Note
FDD
9 10 11 12 13
4
14 15
0
21
Digit No.
of code
A
B
C
D
S
T
V
W
0
1
2
3
4
5
6
7
8
9
M
R
A
B
C
D
E
F
G
H
J
K
S
T
U
V
W
X
P
Q
Note 1
3
5
6
Note 2
Note 3
V
A
B
C
D
H
F
G
K
L
J
M
T
P
R
A
E
P
S
R
V
T
W
19
1 2 3 4 5 6 7 8
Digit
10
11
12
13
14
21
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
Note 8:
20
Description
<Approvals for hazardous, for fieldbus>
Note
FDD
9 10 11 12 13
4
21
0
None (for ordinary locations)
A
TIIS, Flameproof (Conduit seal)
TIIS, Flameproof (Cable gland seal)
FM, Flameproof (or explosionproof)
CSA, Flameproof (or explosionproof)
ATEX, Flameproof
B
C
D
E
X
Approval pending
14 15
ATEX, Intrinsic safty (Entity)
SAA, Flameproof (or explosionproof)
Approval pending
Approval pending
K
F
ATEX, FISCO
Approval pending
Note 8
4
<Capillary and mounting bracket>
Capillary
Mounting bracket
armor of capilary
D
Note 4
1.5 m
304 Stainless steel
PVC
(*4)
E
Note 4
3
304 Stainless steel
PVC
(*4)
L
Note 4
5
304 Stainless steel
PVC
(*4)
F
Note 4
6
304 Stainless steel
PVC
(*4)
M
Note 4
7
304 Stainless steel
PVC
(*4)
N
Note 4
8
304 Stainless steel
PVC
(*4)
P
Note 4
10
304 Stainless steel
PVC
(*4)
Q
Note 5
1.5
304 Stainless steel
Stainless steel
(*5)
R
Note 5
3
304 Stainless steel
Stainless steel
(*5)
S
Note 5
5
304 Stainless steel
Stainless steel
(*5)
T
Note 5
6
304 Stainless steel
Stainless steel
(*5)
V
Note 4
7
304 Stainless steel
Stainless steel
(*4)
W
Note 4
8
304 Stainless steel
Stainless steel
(*4)
X
Note 4
10
304 Stainless steel
Stainless steel
(*4)
<Options>
Extra SS tag plate
Stainless steel elec. housing
Coating of cell
None
None
None
Y
Yes
None
None
B
None
Yes
None
C
(*6)
Note 6
Yes
Yes
None
E
None
None
Yes
M
Yes
None
Yes
N
None
Yes
Yes
P
Yes
Yes
Yes
Q
<Special applications and fill fluid>
Treatment
Fill fluid
Y
Standard
Silicone oil
W
Standard
Fluorinated oil
G
Degreasing
Silicone oil
A
Oxygen service
Fluorinated oil (7th digit code “V”, “A”, “B”, “C” and “D”)
D
Chlorine service
Fluorinated oil (7th digit code “H”, “F”, “G”, “K”, “L” and “T”)
H
High temp. 250°C
Silicone oil
J
High temp. 300°C
Silicone oil
(*7) Note 7
High temp. and vacuum (250°C) Silicone oil 7th digit code “V”, “A”, “B”,
S
High temp. and vacuum (300°C) Silicone oil “C”, and “D”
T
High temp. and high vacuum Silicone oil
K
<Teflon membrane>
None
Y
Yes (Available for 5th digit code “0”, “2”, “4”, “6”, “8”, “A”, “C”, “E”, “G”, “J”, “P”,
C
“M”, “R”, “S”, “T”, “V”, “X” and 7th digit code “V”, “H”, “M”, “T”, “P”, “R”.
Not available for the 13th digit code “H”, “J”, “S”, “T”, “K”.)
<Other options>
H
High accuracy type
J
Low temperature effect type
K
H+J
(*1) 100: 1 turn down is possible, but should be used at a span greater than 1/40 of the maximum span for better performance.
(*2) In case of 13th digit code “S”, “T”, “K” and 5th digit code “1”, “3”, “5”, “7”, “B”, “D”, “F”, “H”, “Q”, “K”, “U”, “W” are
available.
(*3) Available for 6th digit code “2, 3” and 5th digit code “0, 2, 4, 6, 8, A, C, E, G, J, P, M, R, S, T, W”.
(*4) Available for 13th digit code “Y, W, G, A, D”.
Inquire about in case of 13th other code.
(*5) Available for 13th digit code “Y”, “W”, “G”, “A”, “D”, “H”, “J”, “S”, “T”, “K”.
(*6) Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”.
(*7) Treatment; Standard
(*8) In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available.
Digit No.
of code
Remote seal type pressure transmitter : FDB
1 2 3 4 5 6 7 8
Digit
4
5
6
7
9
Description
<Conduit connection>
G1/2
(×1)
1/2-14NPT (×1)
Combination with 12th digit code
Pg13.5
(×1) “C, E, P, Q” are not available.
M20 × 1.5 (×1)
(×2)
G1/2
1/2-14NPT (×2)
Pg13.5
(×2)
M20 × 1.5 (×2)
<Flanges>
Mounting flange Flange size and rating
Ranges
1 2 3
4 5
304 stainless
* * *
JIS 10K 80A
steel
* * *
JIS 10K 100A
* * *
ANSI/JPI 150LB “3”
* * *
ANSI/JPI 150LB “4”
* * *
DIN PN16/40 DN80
* * *
DIN PN16 DN100
* * *
JIS 20K 80A
* * *
JIS 30K 80A
* * *
ANSI/JPI 300LB 3B
* * *
ANSI/JPI 600LB 3B
Carbon steel
* * *
JIS 10K 80A
* * *
JIS 10K 100A
* * *
ANSI/JPI 150LB “3”
* * *
ANSI/JPI 150LB “4”
* * *
DIN PN16/40 DN80
* * *
DIN PN16 DN100
* *
Screw type, JIS/ISO G1
316 stainless
* * *
ANSI/JPI 150LB 3B
steel
* * *
ANSI/JPI 150LB 4B
* * *
ANSI/JPI 300LB 3B
* * *
ANSI/JPI 300LB 4B
* * *
ANSI/JPI 600LB 3B
None
* * *
3 inch wafer
(wafer type)
* * *
4 inch wafer
<Span limit (*2) [kPa]>
1.3…130
5…500
30…3000
100…10000
Available only with material code “V”
500…50000
<Material/diaphragm extension>
Diaphragm
Flange face
Diaph. extension [mm]
316L stainless
316 stainless
0
steel
steel
50
100
(*3)
150
200
Hastelloy-C
Hastelloy-C
0
50
100
150
200
316L stainless
316 stainless
0
+Au coating
steel
Monel
Monel
0
Tantalum
Tantalum
0
Titanium
Titanium
0
(*4)
Zirconium
Zirconium
0
<Digital indicator, arrester and communication>
Digital indicator
Arrester
Communication type
None
None
Foundation Fieldbus
None
Yes
Foundation Fieldbus
Yes
None
Foundation Fieldbus
Yes
Yes
Foundation Fieldbus
None
None
Yes
Yes
None
Yes
None
Yes
Profibus
Profibus
Profibus
Profibus
Note
FDB
9 10 11 12 13 14 15
4
21
Digit No.
of code
A
B
C
D
S
T
V
W
0
1
3
4
6
7
9
M
S
T
A
B
D
E
G
H
K
V
W
X
Y
U
P
Q
Note 2
1
2
3
4
5
Note 1
Note 3
Note 4
V (*1)
A
B
C
D
H
F
G
K
L
J
M
T
P
R
A
E
P
S
R
V
T
W
21
1 2 3 4 5 6 7 8
Digit
10
Description
<Approvals for hazardous, for fieldbus>
Note
FDB
9 10 11 12 13 14 15
None (for ordinary locations)
A
TIIS, Flameproof (Conduit seal)
TIIS, Flameproof (Cable gland seal)
FM, Flameproof (or explosionproof)
CSA, Flameproof (or explosionproof)
ATEX, Flameproof
B
C
D
E
X
ATEX, Intrinsic safty (Entity)
SAA, Flameproof (or explosionproof)
ATEX, FISCO
Approval pending
21
4
Approval pending
Approval pending
K
F
Approval pending
4
Note 10
11
12
13
14
15
21
<Capillary and mounting bracket>
Capillary
Mounting bracket
Armor of capillary
1.5 m
304 Stainless steel
PVC
(*5)
3
304 Stainless steel
PVC
(*5)
5
304 Stainless steel
PVC
(*5)
6
304 Stainless steel
PVC
(*5)
7
304 Stainless steel
PVC
(*5)
8
304 Stainless steel
PVC
(*5)
10
304 Stainless steel
PVC
(*5)
1.5
304 Stainless steel
Stainless steel
(*6)
3
304 Stainless steel
Stainless steel
(*6)
5
304 Stainless steel
Stainless steel
(*6)
6
304 Stainless steel
Stainless steel
(*6)
7
304 Stainless steel
Stainless steel
(*5)
8
304 Stainless steel
Stainless steel
(*5)
10
304 Stainless steel
Stainless steel
(*5)
<Options>
Extra SS tag plate
Stainless steel elec. housing Coating of cell
None
None
None
Yes
None
None
None
Yes
None
(*7)
Yes
Yes
None
None
None
Yes
Yes
None
Yes
None
Yes
Yes
Yes
Yes
Yes
<Special applications and fill fluid>
Treatment
Fill fluid
Standard
Silicone oil
Standard
Fluorinated oil
Degreasing
Silicone oil
Oxygen service
Fluorinated oil (7th digit code “V”, “A”, “B”, “C” and “D”)
Chlorine service
Fluorinated oil (7th digit code “H”, “F”, “G”, “K”, “L” and “T”)
High temp. 250°C
Silicone oil •Available for 6th digit code “1”, “2” or
(* 8)
High temp. 300°C
Silicone oil “3”. In case of 13th code “S”, “T”, “K”,
High temp. and vacuum (250°C) Silicone oil available for 6th digit code “2”, “3” only.
High temp. and vacuum (300°C) Silicone oil •Available for 7th digit code “V”, “A”,
High temp. and high vacuum Silicone oil “B”, “C” or “D”.
Note 5
Note 5
Note 5
Note 5
Note 5
Note 5
Note 5
Note 6
Note 6
Note 6
Note 6
Note 5
Note 5
Note 5
Note 7
Note 8
<Teflon membrane>
None
Yes (Available for the 5th digit code “0”, “2”, “3”, “5”, “6”, “8”, “A”, “C”, “D”,
“F”, “G”, “J”, “P”, “R” and 7th digit code “V”, “H”, “M”, “T”, “P”, “R”.
Not available for the 13th digit code “H”, “J”, “S”, “T”, “K”.)
Note 9
<Bolt/nut> (*9)
None
(6th digit code “1”, “2”, “3”)
Cr-Mo alloy hexagon socket head cap screw/carbon steel nut (6th digit code
Cr-Mo alloy hexagon bolt/carbon steel unit
“4”, “5”)
304 stainless steel/304 stainless steel (6th digit code “4”)
630 stainless steel/304 stainless steel (6th digit code "5")
<Other options>
High accuracy type
Low temperature effect type
H+J
D
E
L
F
M
N
P
Q
R
S
T
V
W
X
Y
B
C
E
M
N
P
Q
Y
W
G
A
D
H
J
S
T
K
Y
C
Y
A
B
E
F
H
J
K
Note 1: (*1) If range 4 or 5 is selected, specify material “V” in any cases.
Note 2: (*2) 100: 1 turn down is possible, but should be used at a span greater than 1/40 of the maximum span for better performance.
Note 3: (*3) Available for 13th digit code “S”, “T”, “K” and 5th digit code “1“,“4“,“7“,“B“,“E“,“H“,“Q“,“T“,“W“,“Y“.
Note 4: (*4) Available for 6th digit code "2",“3“ and 5th digit “0“,“3“,“6“,“9“,“A“,“D“,“G“,“P“, “M“,“S“,“T“,“U“,“V“,“X“.
Note 5: (*5) Available for 13th digit code “Y, W, G, A, D”. Inquire about in case of 13th other code.
Note 6: (*6) Available for 13th digit code “Y”, “W”, “G”, “A”, “D”, “H”, “J”, “S”, “T”, “K”.
Note 7: (*7) Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”.
Note 8: (*8) Treatment; Standard
Note 9: (*9) In case of tropical use, select stainless bolts and nuts.
Note 10:(*10) In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available.
22
Digit No.
of code
Small frange type level transmitter : FDY
1 2 3 4 5 6 7 8
Digit
4
5
6
7
Description
<Connections>
Conduit
Oval flange
Process
connection
screw
connection
7/16-20UNF
(×1)
G 1/2
Rc1/4
1/4-18NPT
7/16-20UNF
1/2-14NPT (×1)
1/4-18NPT
M10 (or M12)
Pg13.5
(×1)
1/4-18NPT
M10 (or M12)
M20×1.5 (×1)
1/4-18NPT
7/16-20UNF
Pg13.5
(×1)
7/16-20UNF
(×2)
Rc1/4
G 1/2
1/4-18NPT
7/16-20UNF
1/2-14NPT (×2)
1/4-18NPT
M10 (or M12)
Pg13.5
(×2)
1/4-18NPT
M10 (or M12)
M20×1.5 (×2)
1/4-18NPT
7/16-20UNF
Pg13.5
(×2)
<Mounting flange>
Material
Size and rating
304 stainless
JIS 10K 40A
steel
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
ANSI/JPI 150LB 11/2"
ANSI/JPI 150LB 2"
ANSI/JPI 300LB 11/2"
ANSI/JPI 300LB 2"
Carbon steel
JIS 10K 40A
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
ANSI/JPI 150LB 11/2"
ANSI/JPI 150LB 2"
ANSI/JPI 300LB 11/2"
ANSI/JPI 300LB 2"
<Span limit [kPa]>
3
130
12.5
500
<Material>
LP side
Diaphragm
Wetted sensor
Process cover
body
316 stainless steel 316 stainless steel 316 stainless steel
316 stainless steel 316 stainless steel 316 stainless steel
Note
9
Flange face:
316 stainless steel
Hastelloy-C lining Hastelloy-C
316 stainless steel Hastelloy-C
Monel lining
Monel
316 stainless steel Monel
Tantalum lining
Tantalum
316 stainless steel Tantalum
Hastelloy-C lining Hastelloy-C
Hastelloy-C lining Hastelloy-C
Monel
Monel lining
Monel
Monel lining
Tantalum
Tantalum lining
Tantalum
Tantalum lining
<Digital indicator, arrester and communication>
Digital indicator
Arrester
Communication type
None
None
Foundation Fieldbus
None
Yes
Foundation Fieldbus
Yes
None
Foundation Fieldbus
Yes
Yes
Foundation Fieldbus
None
None
Yes
Yes
None
Yes
None
Yes
Profibus
Profibus
Profibus
Profibus
9 10 11 12 13
4
14 15
21
Digit No.
of code
A
B
C
D
E
S
T
V
W
X
Combination with
12th digit code
“C, E, P, Q” are
not available.
HP side
Diaphragm &
flange face
316 stainless steel
Diaphragm:
316L stainless steel
+Au coating
316 stainless steel 316 stainless steel 316 stainless steel Hastelloy-C
316 stainless steel 316 stainless steel 316 stainless steel Monel
316 stainless steel 316 stainless steel 316 stainless steel Tantalum
FDY
0
1
2
3
4
5
A
B
C
D
G
H
J
K
L
M
Q
R
S
T
Note1
5
6
V
J
C
D
E
H
M
T
B
L
U
A
E
P
S
R
V
T
W
23
1 2 3 4 5 6 7 8
Digit
10
11
12
13
14
15
21
Description
<Approvals for hazardous, for fieldbus>
Note
FDY
9 10 11 12 13
None (for ordinary locations)
A
TIIS, Flameproof (Conduit seal)
TIIS, Flameproof (Cable gland seal)
FM, Flameproof (or explosionproof)
CSA, Flameproof (or explosionproof)
ATEX, Flameproof
B
C
D
E
X
Approval pending
ATEX, Intrinsic safty (Entity)
SAA, Flameproof (or explosionproof)
Approval pending
Approval pending
K
F
ATEX, FISCO
Approval pending
Note 4
4
<Diaphragm extension [mm]>
Extension [mm]
Applicable material code
0
Any
50
100
(7th digit code “V” only, 11/2 in. flange is not applicable)
150
200
<Options>
Extra SS tag plate
Stainless steel elec. housing
Coating of cell
None
None
None
Yes
None
None
None
Yes
None
Yes
(*2)
Yes
None
Note 2
None
None
Yes
Yes
None
Yes
None
Yes
Yes
Yes
Yes
Yes
<Special applications and fill fluid>
Treatment
Fill fluid
Standard
Silicone oil
Standard
Fluorinated oil
Degreasing
Silicone oil
Oxygen service
Fluorinated oil (7th digit code “V” only)
Chlorine service
Fluorinated oil (7th digit code “C”, “E”, “H”, “T”, “B”, “U”)
High temp. 250°C
Silicone oil (7th digit code “V” only)
High temp. and vacuum (250°C) Silicone oil (7th digit code “V” only)
<O-ring / Gasket and Teflon membrane>
O-ring / Gasket
Teflon membrane
Viton (O-ring)
None
Teflon (gasket)
None
Viton (O-ring)
Yes
(11th digit code “Y” only)
Teflon (gasket)
Yes
(13th digit code “H”, “S” are not available.)
<Bolt/nut> (*3)
Note 3
Cr-Mo alloy hexagon socket head cap screw/carbon steel nut
Cr-Mo alloy hexagon bolt/nut
304 stainless steel bolt / 304 stainless steel nut
<Other options>
High accuracy type
Low temperature effect type
H+J
14 15
21
4
Y
A
B
C
D
Y
B
C
E
M
N
P
Q
Y
W
G
A
D
H
S
A
B
C
D
A
B
E
H
J
K
Note 1: (*1) 100: 1 turn down is possible for model FDY, but should be used at a span greater than 1/40 of the maximum span for better
performance.
Note 2: (*2) Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”.
Note 3: (*3) In case of tropical use, select stainless bolts and nuts.
Note 4: (*4) In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available.
24
Digit No.
of code
Small frange remote seal type differential pressure transmitter : FDX
1 2 3 4 5 6 7 8
Digit
4
5
6
7
9
10
Description
<Conduit connections>
(×1)
G 1/2
1/2 - 14NPT (×1) Combination with 12th digit code
Pg13.5
(×1) “C, E, P, Q” are not available.
M20 × 1.5 (×1)
(×2)
G 1/2
1/2 - 14NPT (×2)
Pg13.5
(×2)
M20 × 1.5 (×2)
<Flange>
Material
Size and rating
304 stainless
JIS 10K 40A
steel
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
ANSI/JPI 150LB 1 1/2"
ANSI/JPI 150LB 2"
ANSI/JPI 300LB 1 1/2"
ANSI/JPI 300LB 2"
Carbon steel
JIS 10K 40A
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
ANSI/JPI 150LB 1 1/2"
ANSI/JPI 150LB 2"
ANSI/JPI 300LB 1 1/2"
ANSI/JPI 300LB 2"
None
40A, 1 1/2B
(Wafer type)
50A, 2B
Direct mounting adapter connection (* 1)
<Span limit [kPa]>
3........130
12.5...500
<Material/diapharagm extension>
Flange face
Diaphragm extension(mm)
Diaphragm
0
316L stainless steel 316 stainless steel
50
100 (*2)
150
200
0
316L stainless steel
+Au coating
Hastelloy-C
0
Hastelloy-C
Monel
0
Monel
Tantalum
0
Tantalum
<Digital indicator, arrester and communication>
Digital indicator
Arrester
Communication type
None
None
Foundation Fieldbus
None
Yes
Foundation Fieldbus
Yes
None
Foundation Fieldbus
Yes
Yes
Foundation Fieldbus
Note
FDX
9 10 11 12 13
4
Note 1
0
1
2
3
4
5
A
B
C
D
G
H
J
K
L
M
Q
R
S
T
W
X
Y
5
6
Note 2
V
A
B
C
D
J
H
M
T
A
E
P
S
R
V
T
W
None (for ordinary locations)
A
TIIS, Flameproof (Conduit seal)
TIIS, Flameproof (Cable gland seal)
FM, Flameproof (or explosionproof)
CSA, Flameproof (or explosionproof)
ATEX, Flameproof
B
C
D
E
X
ATEX, FISCO
Digit No.
of code
A
B
C
D
S
T
V
W
None
None
Profibus
None
Yes
Profibus
Yes
None
Profibus
Yes
Yes
Profibus
<Approvals for hazardous, for fieldbus>
ATEX, Intrinsic safty (Entity)
SAA, Flameproof (or explosionproof)
14 15 16 17 18 19 20 21
Approval pending
Approval pending
Approval pending
K
F
Approval pending
4
Note 5
25
1 2 3 4 5 6 7 8
Digit
11
12
13
14
Description
<Capillary and mounting bracket>
mounting bracket Capillary
armor of capillary
Stainless steel
1.5m
PVC
3m
5m
1.5m
Stainless steel
3m
5m
Note
(*4)
FDX
Note 2: (*2)
Note 3: (*3)
Note 4: (*4)
Note 5: (*5)
14 15 16 17 18 19 20 21
Digit No.
of code
D
E
L
Q
R
S
Note4
<Options>
Stainless steel elec. housing Coating of cell
Extra tag tag plate
None
None
None
Yes
None
None
Note3
None
Yes
None
(*3)
Yes
Yes
None
None
None
Yes
Yes
None
Yes
None
Yes
Yes
Yes
Yes
Yes
<Treatment/Fill fluid>
Treatment
Fill fluid
Standard
Silicone oil (for general use)
Fluorinated oil
Standard
Degreasing
Silicone oil
Fluorinated oil (7th digit code “V”, “A”, “B”, “C” and “D”)
Oxygen service
Chlorine service
Fluorinated oil (7th digit code “H” and “T”)
High temp. 250°C
Silicone oil
(7th digit code “V”, “A”, “B”, “C” and “D”)
High temp. and vacuum (250°C) Silicone oil
<Teflon membrane>
None
Yes (Available for 7th digit code “V”, “H”, “M”, “T”. Not available
for 5th digit code “Y” and 13th digit code “H”, “S”.)
Note 1: (*1)
9 10 11 12 13
4
Y
B
C
E
M
N
P
Q
Y
W
G
A
D
H
S
Y
C
Direct mounting adapter type is specified at 16th to 20th digit.
Direct mounting adapter is available only for 7th digit code “V”.
Diaphragm extension is available only for 2" (50A) flanges.
Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”.
Availalde for 13th digit code “Y, W, G, A, D”.
Inquire about in case of 13th other code.
In case of 10th code is “4” (ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available.
Specifications of Direct Mounting Adapter {for 15, 20A (1/2, 3/4”) connection} and others
Note 1. When odering the instrument with direct mounting adapter, specify “Y” in the 5th digit of Code Symbol, and specify
16th digit to 20th digit.
When odering the instrument without direct mounting adapter, nothing should be filled in the 16th to 20th digit.
2. Unless otherwise described in the specifications, leave the 21st digit blank.
1 2 3 4 5 6 7 8
Digit
Description
16, 17 <Process connection (direct mounting adapter)>
JIS 10K 15A
JIS 10K 20A
JIS 20K 15A
JIS 20K 20A
JIS 30K 15A
JIS 30K 20A
ANSI/JPI 150LB 1/2"
ANSI/JPI 150LB 3/4"
ANSI/JPI 300LB 1/2"
ANSI/JPI 300LB 3/4"
Screw connection Rc1/2
Screw connection Rc3/4
Screw connection Rc1/2 - 14NPT
Screw connection Rc3/4 - 14NPT
18
<Material (direct mounting adapter)>
Adapter
Bolts/nuts
(* 1)
316 Stainless Steel
Cr-Mo steel/carbon steel
19
<Vent/drain (for direct mounting adapter)>
Standard
Long type
20
<Gasket (for direct mounting adapter)>
Standard (Teflon) (Only Y, W, G, A and D can be specified on 13th digit).
For high temperature (spiral gasket) (Only H and S can be
specified on 13th digit).
21
<Other options>
High accuracy type
Low temperature effect type
H+J
Note
FDX
9 10 11 12 13
14 15 16 17 18 19 20 21
0
1 1
1 2
2 1
2 2
3 1
3 2
1H
1 T
2H
2 T
SR
S 2
SN
ST
Note 1
Note (*1) For connection of transmitter receiving pressure unit and direct mounting adapter
26
4
W
A
N
1
2
H
J
K
Digit No.
of code
Small frange remote seal type pressure transmitter : FDW
1 2 3 4 5 6 7 8
Digit
4
5
6
7
9
Description
<Conduit connection>
(×1)
G1/2
1/2 - 14NPT (×1)
Combination with 12th digit code
Pg13.5
(×1) “C, E, P, Q” are not available.
M20×1.5
(×1)
(×2)
G1/2
1/2 - 14NPT (×2)
Pg13.5
(×2)
M20 X 1.5 (×2)
<Flange>
Material
Size and rating
304 stainless
JIS 10K 40A
steel
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
JIS 63K 40A
JIS 63K 50A
ANSI/JPI 150LB 1 1/2"
ANSI/JPI 150LB 2"
ANSI/JPI 300LB 1 1/2"
ANSI/JPI 300LB 2"
ANSI/JPI 600LB 1 1/2"
ANSI/JPI 600LB 2"
Carbon steel
JIS 10K 40A
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
JIS 63K 40A
JIS 63K 50A
ANSI/JPI 150LB 1 1/2"
ANSI/JPI 150LB 2"
ANSI/JPI 300LB 1 1/2"
ANSI/JPI 300LB 2"
ANSI/JPI 600LB 1 1/2"
ANSI/JPI 600LB 2"
None
40A, 1 1/2B
(Wafer type)
50A, 2B
Direct mounting adapter connection (* 1)
<Span limit [kPa] >
50.....3000
250...10000
<Material/diapharagm extension>
Diaphragm extension (mm)
Flange face
Diaphragm
0
316L stainless steel 316 stainless steel
50
100
(* 2)
150
200
0
316L stainless steel
+Au coating
0
Hastelloy-C
Hastelloy-C
0
Monel
Monel
0
Tantalum
Tantalum
<Digital indicator, arrester and communication>
Digital indicator
Arrester
Communication type
None
None
Foundation Fieldbus
None
Yes
Foundation Fieldbus
Yes
None
Foundation Fieldbus
Yes
Yes
Foundation Fieldbus
None
None
Yes
Yes
None
Yes
None
Yes
Profibus
Profibus
Profibus
Profibus
Note
F DW
9 10 11 12 13
4
14 15 16 17 18 19 20 21
0
Digit No.
of code
A
B
C
D
S
T
V
W
Note 1
0
1
2
3
4
5
6
7
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
Y
3
4
Note 2
V
A
B
C
D
J
H
M
T
A
E
P
S
R
V
T
W
27
1 2 3 4 5 6 7 8
Digit
10
11
12
13
14
15
Description
<Approvals for hazardous, for fieldbus>
9 10 11 12 13
TIIS, Flameproof (Conduit seal)
TIIS, Flameproof (Cable gland seal)
FM, Flameproof (or explosionproof)
CSA, Flameproof (or explosionproof)
ATEX, Flameproof
B
C
D
E
X
Approval pending
ATEX, Intrinsic safty (Entity)
SAA, Flameproof (or explosionproof)
Approval pending
Approval pending
K
F
ATEX, FISCO
Approval pending
Note6
4
<Capillary and mounting bracket>
Mounting bracket
Capillary
Armor of Capillary
Stainless steel
1.5m
PVC
(*5)
Note5
3m
5m
1.5m
Stainless steel
3m
5m
<Options>
Stainless steel elec. housing Coating of cell
Extra SS tag plate
None
None
None
Yes
None
None
None
Yes
None
(*3)
Note3
Yes
Yes
None
None
None
Yes
Yes
None
Yes
None
Yes
Yes
Yes
Yes
Yes
<Special applications and fill fluid>
Treatment
Fill fluid
Standard
Silicone oil
Standard
Fluorinated oil
Degreasing
Silicone oil
Fluorinated oil (7th digit code “V”, “A”, “B”, “C” and “D”)
Oxygen service
Chlorine service
Fluorinated oil (7th digit code “H” and “T”)
High temp. 250°C
Silicone oil
High temp. and vacuum (250°C) Silicone oil
<Teflon membrane>
None
Yes (Available for 7th digit code “V”, “H”, “M”, “T”. Not availalbe for
5th digit code “Y”, and 13 digit code “H”, “S”.)
Note4
<Bolt/nut> (*4)
None
6th digit code “3”
Cr-Mo alloy hexagon socket head cap bolt/
carbon steel nut
6th digit code “4”
Cr-Mo alloy hexagon bolt/carbon steel nut
304 stainless steel bolt/304 stainless steel nut
(*2)
(*3)
(*4)
(*5)
14 15 16 17 18 19 20 21
4
A
Note 6: (*6)
28
F DW
None (for ordinary locations)
Note 1: (*1)
Note 2:
Note 3:
Note 4:
Note 5:
Note
D
E
L
Q
R
S
Y
B
C
E
M
N
P
Q
Y
W
G
A
D
H
S
Y
C
Y
A
B
E
Direct mounting adapter type is specified at 16th to 20th digit.
Direct mounting adapter is available only for 7th digit code “V”.
Diaphragm extension is available only for 2" (50A) flanges.
Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select “Yes”.
In case of tropical use, select stainless bolts and nuts.
Available for 13th digit code “Y, W, G, A, D”.
Inquire about in case of 13th other code.
In case of 10th code is “4”(ATEX, FISCO), then the 9th code, E, S, V and W (with arrester option) are not available.
Digit No.
of code
Specifications of Direct Mounting Adapter {for 15, 20A (1/2, 3/4”) connection} and others
Note 1. When odering the instrument with direct mounting adapter, specify “Y” in the 5th digit of Code Symbol, and specify
16th digit to 20th digit.
When odering the instrument without direct mounting adapter, nothing should be filled in the 16th to 20th digit.
2. Unless otherwise described in the specifications, leave the 21st digit blank.
1 2 3 4 5 6 7 8
Digit
Description
Note
16, 17 <Process connection (direct mounting adapter)>
JIS 10K 15A
JIS 10K 20A
JIS 20K 15A
JIS 20K 20A
JIS 30K 15A
JIS 30K 20A
JIS 63K 15A
JIS 63K 20A
ANSI/JPI 150LB 1/2"
ANSI/JPI 150LB 3/4"
ANSI/JPI 300LB 1/2"
ANSI/JPI 300LB 3/4"
ANSI/JPI 600LB 1/2"
ANSI/JPI 600LB 3/4"
Screw connection Rc1/2
Screw connection Rc3/4
Screw connection Rc1/2 - 14NPT
Screw connection Rc3/4 - 14NPT
18
<Material (direct mounting adapter)>
Note 1
Adapter
Bolts/nuts
(* 1)
316 Stainless Steel
Cr-Mo steel/carbon steel
19
<Vent/drain (for direct mounting adapter)>
Standard
Long type
20
<Gasket (for direct mounting adapter)>
Standard (Teflon)(Only Y, W, G, A and D can be specified on 13th digit).
For high temperature (spiral gasket) (Only H and S can be specified on
13th digit).
21
<Other options>
High accuracy type
F DW
9 10 11 12 13
14 15 16 17 18 19 20 21
4
Digit No.
of code
1 1
1 2
2 1
2 2
3 1
3 2
6 1
6 2
1H
1T
2H
2T
4H
4T
SR
S2
SN
ST
W
A
N
1
2
H
Note1: (* 1) For connection of transmitter receiving pressure unit and direct mounting adapter
29
ORDERING INFORMATION
When ordering this instrument, specify:
1. CODE SYMBOLS
2. Calibration range (XD_SCALE) and unit (CAL_UNIT)
• Unless specified, the range is maximum span.
3. Output scale and unit (OUT_SCALE)
• Unless specified, the scale is the same as the
calibration range.
4. Output mode (L_TYPE)
• Select any of Direct/Indirect Linear/Indirect SORT.
• Unless otherwise specified,
q In case of output scale in flow rates
Indirect SORT (extraction output)
w In case of other units
Indirect linear (proportional output)
5. Low flow rate cut point (specify only when needed for
flow measurement)
• Specify in percentages of output scale
6. Output orientation (burnout direction) when abnormality is occurred in the transmitter.
Select Hold / Overscale / Underscale.
Unless specified, output hold function is supplied.
7. Setting of external zero adjustment SW
• Select either of “valid” and “invalid”
• Unless otherwise specified, “valid” is selected.
8. Tag No.
• Up to 26 alphanumerical characters.
• Unless otherwise specified, the tag No. is EFB002 (but, not stamped).
9. Node address (if required)
• Unless specified, “0 × F0”(Foundation Fieldbus),
“0 × 03”(Profibus)
10. Display scale and unit (specify only for the transmitter
with a digital indicator)
• For the settable range, contact Fuji Electric Co.
Ltd.
• No low flow cut is performed
• Unless otherwise specified, it conforms to the output scale.
30
OUTLINE DIAGRAM OF EACH STANDARD MODEL (Unit:mm)
Differential pressure / flow transmitter : FDC
< 7th digit code without : B, L, U >
Note 2)
Vent/drain plug
(When the vent/drain plug
attatched on the upper side
of the detector)
In case of 4th digit code “S,V,W,X”
52.5
Down
88
38
U-bolt M8
58
Note 1)
Cable gland
(option)
37
237
4 Holes
9 Dia.
ø80
70
105
ø80
Up
130
120
43.5
“A” Press. conn.
123
MTG. pipe JIS 50A
(2B)
Fastener
(Flameproof only)
(10)
“B” Conduit conn.2
Zero ADJ. screw
“C” Conduit conn.
“B” Conduit conn.1
Vent/drain plug
154
Detail “A”
(Press. conn.)
ø18.5
Detail “B”
(Conduit conn.)
59
Detail “C”
43
Earth terminal
ø13
H
2.5
ø15
Electronics
unit
Side vent
(option)
G 1/2
D
Press.conn.
(Low pressure side)
See table 1
See table 1
41.3
ø7
Press. conn.
H
A, S
G1/2
17
8
Rc1/4
B, T
1/2-14NPT
16
5
1/4-18NPT
C, V
Pg13.5
8
4.5
1/4-18NPT
D, W
M20 1.5
16
5
1/4-18NPT
E, X
Pg13.5
8
4.5
1/4-18NPT
Sensor
unit
Press.conn.
(High pressure
side)
4-M8 12
Conduit conn.
D
E
F
4th digit of the
code symbols
231
E
17
8
F
Oval flange screw
See table 1
Oval flange screw
7/16-20UNF
Screw depth 15
7/16-20UNF
Screw depth 15
M10
Screw depth 15
M10
Screw depth 15
7/16-20UNF
Screw depth 15
Table 1
54
70
104
CONNECTION DIAGRAM
Note 1) Cable gland is supplied in case of flameproof packing type.
ø11 cable is suitable.
Note 2) The pressure connector is located on the down side surface of
the detector, when the vent /drain plug is attatched on the upper
side of the detector.
CK CK
(M4 screws)
Do not connect.
Field bus
31
Differential pressure / flow transmitter : FDC
< 7th digit code : B, L, U >
“A” or “B” Press. conn.
MTG. pipe JIS 50A
(2B)
U-bolt M8
Zero ADJ. screw
In case of 4th digit code
“S,V,W,X”
“C” Conduit conn.2
41.3
Fastener
(Flameproof only)
(10)
Oval flange screw
See table 1
ø80
120
52.5
70
ø80
105
Up
88
Down
38
Note 1)
Cable gland
(option)
40
58
4 Holes
9 Dia.
240
“D” Conduit conn.
“C” Conduit conn.1
Vent/drain plug
186
91
Detail “A”
(Press. conn.)
Detail “C”
(Conduit conn.)
Earth terminal
Electronics
unit
G 1/2
E
ø4
234
F
17
H
1
0
2 -0.1
+0.2
+0.1
43
ø13
ø15
ø16
ø12
Detail “D”
Sensor
unit
See table 1
Detail “B”
(Press. conn)
ø16
Press.conn.
(Low pressure side)
Press.conn.
(High pressure
side)
4-M8 12
10
1/4-18NPT
54
70
104
ø4
4th digit of the
code symbols
E
Conduit conn.
F
H
A, S
G1/2
17
8
B, T
1/2-14NPT
16
5
C, V
Pg13.5
8
4.5
D, W
M20 1.5
16
5
E, X
Pg13.5
8
4.5
Oval flange screw
7/16-20UNF
Screw depth 10
7/16-20UNF
Screw depth 10
M10
Screw depth 10
M10
Screw depth 10
7/16-20UNF
Screw depth 10
Table 1
Note 1) Cable gland is supplied in case of 10th digit code “C”.
ø11 cable is suitable.
32
CONNECTION DIAGRAM
CK CK
(M4 screws)
Do not connect.
Field bus
Pressure transmitter : FDG
< 7th digit code without : B, L, U >
Note2)
Vent/drain plug
(When the vent/drain plug
attached on the upper side
of the detector)
“B” Conduit conn.2
In case of 4th digit
code “S,V,W,X”
52.5
58
Down
88
38
U - bolt M8
ø80
70
105
ø80
Up
130
104
43.5
“A” Press. conn.
123
MTG. Pipe JIS 50A
(2B)
Fastener
(Flameproof only)
(10)
Zero ADJ. screw
37
Cable gland
(option)
237
216 (6th digital code “5”)
4 holes
9 dia.
Note1)
Vent/drain plug
“C” Conduit conn.
“B” Conduit conn.1
154
Detail “A”
(Press. conn.)
ø18.5
Detail “B”
(Conduit conn.)
Earth terminal
Detail “C”
59
43
ø13
H
G 1/2
D
Side
vent
(option)
See table 1
See table 1
231
210 (6th digit code “5”)
ø7
Electronics
unit
Oval flange
screw
See table 1
41.3
E
17
8
F
2.5
ø15
Sensor
unit
4-M8 12
Conduit conn.
D
E
F
4th digit of the
code symbols
Press.conn.
H
A, S
G1/2
17
8
Rc1/4
B, T
1/2-14NPT
16
5
1/4-18NPT
C, V
Pg13.5
8
4.5
1/4-18NPT
D, W
M20 1.5
16
5
1/4-18NPT
E, X
Pg13.5
8
4.5
1/4-18NPT
Oval flange screw
7/16-20UNF
Screw depth15
7/16-20UNF
Screw depth15
M10
Screw depth15
M10
Screw depth15
7/16-20UNF
Screw depth15
27
54
70
104
Table 1
Note1)
Note2)
CONNECTION
DIAGRAM
Cable gland is supplied in case of flamproof packing type.
ø11 cable is suitable.
The pressure connector is located on the down side surface of
the detector, when the vent / drainplug is attatched on the upper
side of the detector.
CK CK
(M4 screws)
Do not connect.
Field bus
33
Pressure transmitter : FDG
< 7th digit code : B, L, U >
52.5
43.5
Down
88
38
104
70
ø80
105
Up
ø80
“C” Conduit conn.2
(10)
U - bolt M8
Fastener
(Flameproof only)
In case of 4th digit code “S,V,W,X”
Zero ADJ. screw
MTG. Pipe
JIS 50A (2B)
58
40
Cable gland
(option) Note)
4 holes
9 dia.
240
“C” Conduit conn.1
“D” Conduit conn.
155
Detail “A”
(Press. conn.)
4th digit code “A. S”
ø16
Earth terminal
60
43
ø13
ø15
2 -0.1
+0.2
Detail “D”
Detail “C”
(Conduit conn.)
Electronics
unit
F
17
H
1
0
ø12 +0.1
ø4
234
G1/2
E
See table 1
P
Detail “B”
4th digit code
“B,C,D,E,T,V,W,X”
View from P
4-M8 12
ø16
“A” or “B”
Press. conn.
Vent/drain
plug
41.3
10
1/4-18NPT
54
Oval flange
screw
See table 1
ø4
Conduit conn.
D
E
F
4th digit of the
code symbols
A, S
G1/2
17
8
B, T
1/2-14NPT
16
5
C, V
Pg13.5
8
4.5
D, W
M20 1.5
16
5
E, X
Pg13.5
8
4.5
7/16-20UNF
Screw depth10
7/16-20UNF
Screw depth10
M10
Screw depth10
M10
Screw depth10
7/16-20UNF
Screw depth10
Cable gland is supplied in case of 10th digit code “C”.
ø11 cable is suitable.
34
104
Oval flange screw
Table 1
Note)
98
70
CONNECTION
DIAGRAM
CK CK
(M4 screws)
Do not connect.
Field bus
Sensor
unit
Absolute pressure transmitter : FDA
Vent/drain plug Note2)
(When the nent/drain plug
attached on the upper side
of the detector)
Fastener
(Flameproof only)
“B” Conduit conn.2
52.5
58
ø80
Down
88
38
U - bolt M8
104
70
105
ø80
Up
43.5
(10)
Zero ADJ. screw
“A” Press. conn.
123
MTG. Pipe JIS 50A
(2B)
In case of 4th digit code “S,V,W,X”
37
Cable gland (option)
237
4 holes
9 dia.
Note1)
“C” Conduit conn.
“B” Conduit conn.1
Vent / Drain Plug
155
60
Detail “A”
(Press. conn.)
Datail “B”
(Conduit conn.)
Detail “C”
ø7
43
Earth terminal
Electronics
unit
ø13
ø15
H
ø18.5
2-M8 12
See Table 1
Conduit conn.
D
E
F
4th digit of the
code symbols
Press.conn.
H
G1/2
17
8
Rc1/4
B, T
1/2-14NPT
16
5
1/4-18NPT
C, V
Pg13.5
8
4.5
1/4-18NPT
D, W
M20 1.5
16
5
1/4-18NPT
E, X
Pg13.5
8
4.5
1/4-18NPT
A, S
Oval flange screw
27
7/16-20UNF
screw depth15
7/16-20UNF
screw depth15
M10
screw depth15
M10
screw depth15
7/16-20UNF
screw depth15
120
CONNECTION
DIAGRAM
Cable gland is supplied in case of flamproof packing type.
CK CK
ø11 cable is suitable.
Note2)
50
70
Table 1
Note1)
Side vent
(option)
G 1/2
D
See Table 1
Sensor
unit
41.3
2.5
E
17
8
F
231
Oval flange screw
See table 1
The pressure connector is located on the down side surface of
the detector, when the vent / drainplug is attached on the upper
side of the detector.
(M4 screws)
Do not connect.
Field bus
35
Level transmitter : FDE
< 7th digit code without : B, L, U >
Vent / drain plug Note 2)
(When the vent /drain plug attatched
on the upper side of the detector)
In case of 4th digit code “S, V, W, X”
Flange : ANSI/JPI
-150LB-3B
Zero ADJ.screw
Fastener
(Flameproof only)
(10)
N holes
h dia
43.5
105
Down
88
52.5
ø80
Up
ø80
“B” Conduit conn.2
“A” L.P. conn.
L2
Note 1)
Cable gland
(option)
L1
Vent / drain plug
t
H.P. conn.
øD
øE
øF
øG
øH
t
(Flange)
N-øh
See table 1
11th degit
code
Electronics unit
185
150
126
100
73
38
8-19
JIS-10K-80A
200
160
126
100
73
42
8-23
JIS-20K-80A
210
170
126
100
73
48
8-23
JIS-30K-80A
210
175
151
103
96
38
8-19
JIS-10K-100A
240
195
151
103
96
52
8-25
JIS-30K-100A
191
152.5
126
100
73
44
4-20
ANSI-150LB-3B
Y
0
9.5
~ 13
A
E
50
10
~ 17
B
F
100
10.5 ~ 17.5
C
G
150
11
D
H
200
11.5 ~ 18.5
Press.conn.
J
G1/2
17 8
Rc1/4
B, T
1/2-14NPT
16 5
1/4-18NPT
1/4-18NPT
210
168
126
100
73
49
8-23
ANSI-300LB-3B
210
168
126
100
73
52
8-23
ANSI-600LB-3B
C, V
Pg13.5
8
229
190.5
151
103
96
44
8-20
ANSI-150LB-4B
D, W
M20 1.5
16 5
1/4-18NPT
254
200
151
103
96
52
8-23
ANSI-300LB-4B
200
160
126
100
73
44
8-18
DIN
PN40
DN80
E, X
Pg13.5
8
1/4-18NPT
220
180
151
103
96
40
8-18
DIN
PN16
DN100
4.5
4.5
Table 1
CONNECTION DIAGRAM
CK CK
(M4 screws)
Do not connect.
Field bus
L1
L2
L3
360
160
296
354
154
290
~ 18
A, S
Note 1) Cable grand is suppled in case of flamproof packing type.
ø11 cable is suitable.
Note 2) The pressure connector is located on the down side surface of
the detector, when the vent / detector.
36
Mass apprpx.
(kg)
L (mm)
Conduit conn.
K
M N
4th digit of the
code symbols
G1/2
K
See table 1
Earth terminal
Sensor unit
ø13
ø15
ø7
L3
Detail “C”
Detail “B”
(Conduit conn.)
17
43
143
59 27
øG
øH
øD
øE
øF
J
48
Inner of gasket
Detail “A”
(L.P conn.)
ø18.5
Oval flang screw
See table 1
M N
41.3
2.5
20
8
L
“C” Conduit conn.
“B” Conduit conn.1
Oval flage screw
7/16-20UNF
Screw depth15
7/16-20UNF
Screw depth15
M10
Screw depth15
M10
Screw depth15
7/16-20UNF
Screw depth15
Level transmitter : FDE
< 7th digit code : B, L, U >
Oval flange screw
See table 1
Fastener
(Flameproof only)
Zero ADJ.screw
(10)
N holes
h dia
52.5
107
ø80
Up
ø80
“A” or “B” L.P. conn.
41.3
In case of 4th digit code “S, V, W, X”
105
Flange : ANSI/JPI
-150LB-3B
88
Down
L2
Note 1)
Cable gland
(option)
L1
Vent / drain plug
“C” Conduit conn.1
t
Inner of gasket
91
1/4-18NPT
+0.2
ø12 +0.1
0
1
186
43
40.5
ø16
ø16
46.4
øH
øG
øD
øE
øF
Detail “B”
(L.P conn.)
Detail “A”
(L.P. conn.)
4th digit code “S”
Earth terminal
10
20
2 -0.1
L
“D” Conduit conn.
ø4
L3
Detail “C”
(Conduit conn.)
H.P. conn.
L (mm)
Mass apprpx.
(kg)
Y
0
A
E
50
B
F
100
12.5 ~ 19.5
C
G
150
13
øD
12
L1
L2
L3
350
150
286
CK CK
144
200
øE
150
øF
øG
100
200
160
126
100
210
170
126
100
210
175
151
103
240
195
151
103
191
152.5
126
210
168
126
210
168
229
(M4 screws)
K
G1/2
See table 1
290
Do not connect.
~ 20
Field
bus
13.5 ~ 20.5
126
ø15
CONNECTION DIAGRAM
~ 19
344
D
H
185
11.5 ~ 15
Detail “D”
ø13
17
11th degit
code
Electronics unit
M N
Sensor unit
øH
73
73
t
38
(Flange)
N-øh
8-19
JIS-10K-80A
42
8-23
JIS-20K-80A
73
48
8-23
JIS-30K-80A
96
38
8-19
JIS-10K-100A
96
52
8-25
JIS-30K-100A
100
73
44
4-20
ANSI-150LB-3B
100
73
49
8-23
ANSI-300LB-3B
126
100
73
52
8-23
ANSI-600LB-3B
190.5
151
103
96
44
8-20
ANSI-150LB-4B
254
200
151
103
96
52
8-23
ANSI-300LB-4B
200
160
126
100
73
44
8-18
DIN
PN40
DN80
220
180
151
103
96
40
8-18
DIN
PN16
DN100
4th digit of the
code symbols
Conduit conn.
K
M N
A, S
G1/2
17 8
B, T
1/2-14NPT
16 5
C, V
Pg13.5
8
4.5
D, W
M20 1.5
16 5
E, X
Pg13.5
8
4.5
Oval flage screw
7/16-20UNF
Screw depth10
7/16-20UNF
Screw depth10
M10
Screw depth10
M10
Screw depth10
7/16-20UNF
Screw depth10
Table 1
Note 1) Cable grand is suppled in case of 10th digit code “C”.
ø11 cable is suitable.
37
Remote seal type differential pressure transmitter : FDD
In case of 4th digit code “S,V,W”
MTG. pipe
JIS 50A (2B)
“A” Conduit conn.2
Fastener
(Flamproof only)
(10)
Zero ADJ. screw
104
ø80
Up
105
52.5
70
ø80
U-bolt M8
38
4 holes
9 dia.
88
Down
28
“B” Conduit conn.
58
“A”
Conduit conn. 1
228
Cable gland (option)
N holes
h dia.
øE
P
øF
Note)
No flange is
attached in
case of 5th
digit code
“P,Q”.
øG
øH
øD
Inner of gasket
20
L
t
48
Detail “A”
(Conduit donn.)
ø15
270
43
Detail “B”
ø13
Earth tarminal
222
K M
17
Electronics
unit
G1/2
J
See table 1
4th digit of the
code symbols
S
Conduit donn.
J
K
M
A, S
G1/2
17
8
B, T
1/2-14NPT
16
5
C, V
Pg13.5
8
4.5
D, W
M20 1.5
16
5
S
54
70
120
Table 1
7th digit
code
øD
øE
øF
øG
øH
t
P
(Flange)
N-øh
Mass. appox.
(kg)
11th digit
code
S 11th digit
(m) code
0
14~19.5
D,Q
1.5
M,V
185
150
126
100
73
38
116
8-19
JIS-10K-80A
A,F
50
15~30.5
E,R
3
N,W
200
160
126
100
73
42
116
8-23
JIS-20K-80A
B,J
100
15.5~31
L,S
5
P,X
210
170
126
100
73
48
116
8-23
JIS-30K-80A
C,K
150
16~31.5
F,T
6
210
175
151
103
96
38
141
8-19
JIS-10K-100A
D,L
200
16.5~32
240
195
151
103
96
52
141
8-25
JIS-30K-100A
191
152.5
126
100
73
44
116
4-20
ANSI-150LB-3B
210
168
126
100
73
49
116
8-23
ANSI-300LB-3B
210
168
126
100
73
52
116
8-23
ANSI-600LB-3B
229
190.5
151
103
96
44
141
8-20
ANSI-150LB-4B
254
200
151
103
96
52
141
8-23
ANSI-300LB-4B
200
160
126
100
73
44
116
8-18
DIN
PN40
DN80
220
180
151
103
96
40
141
8-18
DIN
PN16
DN100
V,H,M,T,P,R
L
CONNECTION DIAGRAM
CK CK
NOTE)
Cable gland is supplied in case of flamproof
packing type.
ø11 cable is suitable.
(M4 screws)
Do not connect.
Field bus
38
Sensor
unit
H.P.
L.P.
S
(m)
7
8
10
Remote seal type pressure transmitter : FDB
1
2
3
FDB
4
Note) Cable gland is supplied in case of flamproof packing type.
ø11 cable is suitable.
In case of 4th digit code “S,V,W”
Fastener
(Flameproof only)
“A” Conduit conn.2
U - Bolt M8
(10)
MTG. pipe
JIS 50A (2B)
Zero ADJ. Screw
38
ø80
104
105
Down
88
52.5
70
ø80
Up
30
Cable gland
(Option) Note)
4 holes
9 dia.
58
237
“B” Conduit conn.
“A” Conduit conn.1
Inner of gasket
Detail “A”
(Conduit conn.)
N holes
h dia.
Detail “B”
(Conduit conn.)
ø13
P
17
K M
øG
øH
G1/2
J
20
L
See table 1
t
Earth terminal
7th digit
code
Mass
approx.(kg)
L
V
H
M
T
P
R
0
A
F
50
10.5
B
J
100
11.5
C
K
150
12
D
L
200
12.5
4th digit of
the code
symbols
9.5
A, S
B, T
C, V
Conduit conn.
J
K
G1/2
17
1/2-14NPT 16
Pg13.5
8
M
8
5
4.5
D, W
M20 1.5
5
16
Table 1
øD
øE
185
200
191
43
60
No flange is attached
in case of 5th digit
code “P,Q,R” .
Electronics
unit
231
øE
øF
øD
ø15
2-M8 12
S
øF
øG
øH
t
150
126
100
73
160
126
100
73
210
170
126
100
210
175
151
191
152.5
210
Sensor
unit
50
70
120
P
N-øh
(Flange)
38
116
8-19
JIS-10K-80A
42
116
8-23
JIS-20K-80A
73
48
116
8-23
JIS-30K-80A
103
96
38
141
8-19
JIS-10K-100A
126
100
73
44
116
4-20
ANSI-150LB-3B
168
126
100
73
49
116
8-23
ANSI-300LB-3B
210
168
126
100
73
52
116
8-23
ANSI-600LB-3B
229
190.5
151
103
96
44
141
8-20
ANSI-150LB-4B
200
160
126
100
73
44
116
8-18
DIN PN40 DN80
220
180
151
103
96
40
141
8-18
DIN PN16 DN100
CONNECTION
DIAGRAM
CK CK
(M4 screws)
Do not connect.
Field bus
11th digit code
S (m)
D
Q
1.5
E
R
3
L
S
5
F
T
6
M
V
7
N
W
8
P
X
10
39
Remote seal type pressure transmitter : FDB
4
K 5 V4
Mtg.
JIS 50A (2B)
4th of Code symbols “S, V, W”
type is attached
Zero/span adj.
screw
(10)
FDB
U-bolt M8
Fastener
(flameproof model only)
104
φ80
105
Down
88
52.5
70
φ80
Up
38
30
4 holes
9 dia.
58
237
*Cable gland
(option)
20
“A”
Conduit conn.
“B”
Conduit conn.
45
G1
Packing
2
53 18
100
With field ind.
191
–0.1
φ23.6 –0.2
Earth terminal
(both side)
See table 1
φ30 –0.1
–0.2
43
60
Details of “B”
Details of “A”
φ13
φ15
D
17
206
E
S
C
G1/2
See table 1
4th of Code
symbols
S
2–M8x12
Conduit conn.
D
C
E
17 8
G1/2
Earth
terminal
M4
11th of Code
symbols
D
Q
S (m)
1.5
70
50
120
T
1/2-14NPT
V
Pg13.5
W
M20x1.5
16 5
8 4.5
16 5
No. 8-32UNC
E
R
3
M4
L
S
5
F
T
6
M
V
7
N
W
8
P
X
10
M4
CONNECTION DIAGRAM
CK CK
(M4 screws)
Table 1
Note *: Cable gland is supplied in case of flameproof
packing type. φ11 cable is suitable.
40
Do not connect.
Field bus
Small frange type level transmitter : FDY
< 7th digit code without : B, L, U >
Note2)
Vent / drain plug
(When the vent / drain plug attatched on the upper side of the detector)
In case of frange with
4 bolt holes
In case of 4th digit
code “S, V, W, X”
(10)
Zero ADJ.
screw
43.5
105
52.5
Fastener
(Flameproof only)
N holes
h dia.
Up
ø80
“A” L. P. conn.
ø80
“B” Conduit conn.2
88
Down
L2
Note)
Cable grand (option)
“C” Conduit conn.
L1
Vent / drain plug
Detail “A”
ø7
Detail “B”
ø15
Detail “C”
ø13
H
ø18.5
H.P. conn
L3
K
8
2.5
43
øD
øE
øF
ø49
ø48
M
48
Oval flange screw
See table 1
17
L.P. conn.
41.3
27
t
143
L
20
“B” Conduit conn.1
J
G1/2
See table 1
Inner of gasket
Sensor unit
Electronics unit
L
11th digit of
Code symbols [mm]
øD
0, G
140
105
36
4-19 JIS-10K-40A
1, H
155
120
36
4-19 JIS-10K-50A
2, J
140
105
39
4-19 JIS-20K-40A
øE
t
N-øh
Flange
100
10.5 to 17.5
C
150
11
D
200
11.5 to 18.5
17
8
B, T
1/2-14NPT
18
5
8
4.5
C, V
Pg13.5
M20
Pg13.5
155
120
38
8-19 JIS-20K-50A
4, L
160
120
42
4-23 JIS-30K-40A
E, X
5, M
165
130
42
8-19 JIS-30K-50A
A, Q
127
B, R
152 120.6 39.5
4-20 ANSI/JPI-150-2B
C, S
156 114.3 41
4-23 ANSI/JPI-300LB-1 1/2B
D, T
165
8-20 ANSI/JPI-300LB-2B
42.5
B
G1/2
3, K
127
0
50
A, S
D, W
98.4 37.5
Y
A
CONDUIT CONN.
J
K
M
4TH DIGIT OF THE
CODE SYMBOLS
5th digit
of Code
symbols
1.5
Mass approx, [kg]
16
5
8
4.5
9.5 to 12
10
L1
L2
L3
360 160 296
to 17
354 154 290
to 18
PRESS.CONN.
Oval flange screw
H
7/16-20UNF
Rc1/4
Screw depth15
7/16-20UNF
1/4-18NPT
Screw depth15
M10
1/4-18NPT
Screw depth15
M10
1/4-18NPT
Screw depth15
7/16-20UNF
1/4-18NPT
Screw depth15
Table 1
4-16 ANSI/JPI-150LB-1 1/2B
CONNECTION
DIAGRAM
CK CK
(M4 screws)
Note) Cable gland is supplied in case
of flamproof packing type.
Do not connect.
ø11 cable is suitable.
Field bus
41
Small frange type level transmitter : FDY
< 7th digit code : B, L, U >
Oval flange screw
See Table 1
In case of 4th digit
code “S,V,W, X”
41.3
N holes
h dia.
28
115
ø80
52.5
Up
107
Fastener
(Flameproof only)
43.5
Zero ADJ.
screw
ø80
“C” Conduit conn. 2
“A” or “B”
L. P. conn.
10
In case of flange with
4 bolt holes
88
Down
150
Note)
Cable grand (option)
350
Vent / drain plug
“D” Conduit conn.
“C” Conduit conn. 1
t
Details of “A”
4th of code symbols
“A, S” type
ø16
–0.2
ø12+0.1
1/4 -18NPT
10
øD
øE
øF
ø49
40.5
91
43
186
1
H.P. conn
Details of “B”
4th of code symbols
“B, C, D, E, T, V, W, X” type
ø16
0
2 –0.1
20
286
Inner of gasket
ø4
Earth terminal
Detail “C”
Sensor unit
Detail “D”
ø13
Electronics unit
M
ø15
t
N-øh
Flange
17
øE
K
5th digit
of Code øD
symbols
0, G
140
105
36
4-19 JIS-10K-40A
1, H
155
120
36
4-19 JIS-10K-50A
2, J
140
105
39
4-19 JIS-20K-40A
3, K
155
120
38
8-19 JIS-20K-50A
4, L
160
120
42
4-23 JIS-30K-40A
5, M
165
130
42
8-19 JIS-30K-50A
A, Q
127
98.4 37.5
4-16 ANSI/JPI-150LB-1
See table 1
1/2B
152 120.6 39.5
4-20 ANSI/JPI-150-2B
C, S
158 114.3 41
4-23 ANSI/JPI-300LB-1
D, T
165
8-20 ANSI/JPI-300LB-2B
42.5
Note) Cable gland is supplied in case of 10th digit code “C”.
ø11 cable is suitable.
Conduit conn.
J
K
M
4th digit of the
code symbols
B, R
127
G1/2
J
1/2B
A, S
G1/2
17
8
B, T
1/2-14NPT
16
5
C, V
Pg13.5
8
4.5
D, W
M20
16
5
E, X
Pg13.5
8
4.5
15
Oval flange screw
7/16-20UNF
Screw depth 10
7/16-20UNF
Screw depth 10
M10
Screw depth 10
M10
Screw depth 10
7/16-20UNF
Screw depth 10
Table 1
CONNECTION
DIAGRAM
CK CK
(M4 screws)
Do not connect.
Field bus
42
Small frange remote seal type differential pressure transmitter : FDX
“A” Conduit conn.2 In case of 4th digit code “S,V,W”
Zero ADJ. screw
ø80
104
88
70
38 28
4 holes
9 dia.
Fastene
(Flameproof only)
(10)
U-bolt M8
ø80
52.5
105
MTG. pipe
JIS 50A (2B)
58
228
“B” Conduit conn.
Note)
Cable gland (option)
Inner of gasket
N holes
h dia.
71
øD
øE
ø84
ø49
ø48
“A” Conduit conn. 1
20
L
Detail “A”
t
No flange is attached
in case of 5th digit code
“W, X”
Detail “B”
ø13
ø15
48
270
43
M
Earth terminal
K
17
Electronics
unit
J
222
G1/2
See table 1
S
S
2-M8 12
L.P.
Sensor
unit
H.P.
Inner of gasket
70
120
2-M6 screw depth 9
62
71
ø84
ø49
CONNECTION DIAGRAM
20
<Wafer type>
5th digit of
code symbols
0,G
1,H
2,J
3,K
4,L
5,M
6,N
7,P
A,Q
B,R
C,S
D,T
E,U
F,V
CK CK
Note : In case of wafer type, flange is excluded
from the scope of supply.
Mount flange, referring to the view.
øD
øE
t
N-øh
Flange
140
155
140
155
160
165
175
185
127
152
156
165
156
165
105
120
105
120
120
130
130
145
98.4
120.6
114.3
127
114.3
127
36
36
38
38
42
42
52
54
37.5
39.5
41
42.5
42.5
45.5
4-19
4-19
4-19
8-19
4-23
8-19
4-25
8-23
4-16
4-20
4-23
8-20
4-23
8-20
JIS-10K-40A
JIS-10K-50A
JIS-20K-40A
JIS-20K-50A
JIS-30K-40A
JIS-30K-50A
JIS-63K-40A
JIS-63K-50A
ANSI/JPI-150LB-1 1/2B
ANSI/JPI-150LB-2B
ANSI/JPI-300LB-1 1/2B
ANSI/JPI-300LB-2B
ANSI/JPI-600LB-1 1/2B
ANSI/JPI-600LB-2B
(M4 screws)
Do not connect.
Field bus
Conduit conn.
4th digit of
Code symbols
J
K
M
1
A, S
G /2
17
8
B, T
1/2-14NPT
16
5
C, V
Pg13.5
8
4.5
D, W
M20
16
5
1.5
11th digit of
Capillary
Code symbols length : S [mm]
D,Q
E,R
L,S
1500
3000
5000
Table 1
7th digit of
Code symbols
V, H, M, T
A
B
C
D
L
0
50
100
150
200
Mass approx.
[kg]
14 to 19.5
15 to 30.5
15.5 to 31
16 to 31.5
16.5 to 32
NOTE ) Cable gland is supplied in case of flameproof
packing type. ø11 cable is suitable.
43
Small frange remote seal type differential pressure transmitter : FDX
<With direct mount adaptor>
Vent/drain plug
N holes, h dia.
øF
øE
øD
ø84
25
(102)
Long vent/drain plug
(option)
S
L. P.
H. P.
t
80
20
MTG. pipe
JIS 50A(2B)
Zero ADJ. screw
“A” Conduit conn.2
ø80
104
88
70
38 28
4 holes
9 dia.
Fastener
(Flameproof only)
In case of 4th
digit code “S,V,W”
ø80
52.5
105
(10)
U-bolt M8
Note)
228
58
“B” Conduit conn.
Cable gland (option)
“A” Conduit conn. 1
270
48 43
Detail “A”
Earth
terminal
Detail “B”
ø13
M
ø15
222
17
K
J
Electronics
unit
G1/2
Table 1
4th digit of
code symbols
A, S
Conduit conn.
J
G1/2
K
17
11th digit of
Capillary
Code symbols length : S [mm]
M
8
B, T
1/2-14NPT
16
5
C, V
Pg13.5
8
4.5
D, W
M20 1.5
16
5
16th digit of 17th digit of
øD
code symbols code symbols
1
1
2
2
3
3
1
1
2
2
1
2
1
2
1
2
H
T
H
T
95
100
95
100
115
120
89
98
95
117
D,Q
E,R
L,S
1500
3000
5000
70
120
øE
øF
t
N-øh
70
75
70
75
80
85
60.3
69.9
66.7
82.5
51
56
51
56
55
60
34.9
42.9
34.9
42.9
12
14
14
16
18
18
11.5
13
14.5
16
4-15
4-15
4-15
4-15
4-19
4-19
4-16
4-16
4-16
4-20
JIS-10K-15A
JIS-10K-20A
JIS-20K-15A
JIS-20K-20A
JIS-30K-15A
JIS-30K-20A
ANSI/JPI-150LB 1/2B
ANSI/JPI-150LB 3/4B
ANSI/JPI-300LB 1/2B
ANSI/JPI-300LB 3/4B
CONNECTION DIAGRAM
CK CK
44
(M4 screws)
Do not connect.
Field bus
Note ) Cable gland is supplied in case of
flameproof packing type. ø11 cable is
suitable.
62
Flange
Sensor
unit
Small frange remote seal type differential pressure transmitter : FDX
<With direct mount adaptor (screw connection type)>
Vent/drain plug
Low press. conn. “D”
(102)
25
Long vent/drain plug
(option)
ø84
High press. conn. “D”
S
20
23
Zero ADJ. screw
MTG. pipe
JIS 50A (2B)
U- bolt M8
ø80
104
88
70
Fastener
(Flameproof only)
In case of 4th digit
code “S,V,W”
ø80
52.5
105
(10)
“A” Conduit conn.2
38 28
Note)
4 holes
9 dia.
58
Cable gland (option)
228
“A” Conduit conn. 1
Detail “A”
Detail “B”
ø13
CONNECTION DIAGRAM
CK CK
270
48 43
Earth
terminal
(M4 screws)
Electronics
unit
K
17
M
ø15
“B” Conduit conn
Do not connect.
G1/2
Field bus
222
J
Table 1
4th digit of
Code symbols
A, S
G1/2
Conduit conn.
J
K
M
17
8
1/2-14NPT
B, T
16
5
C, V
Pg13.5
8
4.5
D, W
M20
16
5
16th digit of
Code symbols
1.5
17th digit of
Code symbols
Sensor
unit
11th digit of
Capillary
Code symbols length : S [mm]
D,Q
E,R
L,S
Press. conn."D"
S
R
Rc 1/2
S
N
1/2-14NPT
S
2
Rc3/4
S
T
3/4-14NPT
1500
3000
5000
70
120
62
NOTE ) Cable gland is supplied in case of
10th digit code “C”.
ø11 cable is suitable.
45
Small frange remote seal type pressure transmitter : FDW
“A” Conduit conn.2 In case of 4th digit code “S,V,W”
U - bolt M8
Zero adj. screw
Fastener
(Flameproof only)
(10)
MTG. pipe
JIS 50A (2B)
38
4 holes
9 dia.
ø80
104
105
Down
88
52.5
70
ø80
Up
37
Note)
Cable gland
(option)
58
237
“B” Conduit conn.
“A” Conduit conn.1
N holes
h dia.
Detail “B”
(Conduit conn.)
ø13
J
71
17
K
øD
øE
ø84
ø49
ø48
M
Detail “A”
(Conduit conn.)
ø15
G1/2
See table 1
20
L
Inner of
gasket
t
191
43
60
No flange is attached
in case of 5th digit
code “W,X”
Earth terminal
2-M6 screw depth 9
Inner of gasket
231
71
ø84
ø49
Electronics
unit
S
20
<Wafer type>
7th digit of
Code symbols
L
Mass approx.
[kg]
V, H, M, T
A
B
C
D
0
50
100
150
200
9.5
10.5
11.5
12
12.5
5th digit of code symbols øD
0,G
1,H
2,J
3,K
4,L
5,M
6,N
7,P
A,Q
B,R
C,S
D,T
E,U
F,V
140
155
140
155
160
165
175
185
127
152
156
165
156
165
11th digit of
Capillary
Code symbols length : S [mm]
D, Q
E, R
L, S
70
120
1500
3000
5000
øE
øt
N-øh
(Flange)
105
120
105
120
120
130
130
145
98.4
120.6
114.3
127
114.3
127
36
36
38
38
42
42
52
54
37.5
39.5
41
42.5
42.5
45.5
4-19
4-19
4-19
8-19
4-23
8-19
4-25
8-23
4-16
4-20
4-23
8-20
4-23
8-20
JIS-10K-40A
JIS-10K-50A
JIS-20K-40A
JIS-20K-50A
JIS-30K-40A
JIS-30K-50A
JIS-63K-40A
JIS-63K-50A
ANSI/JPI-150LB-1 1/2B
ANSI/JPI-150LB-2B
ANSI/JPI-300LB-1 1/2B
ANSI/JPI-300LB-2B
ANSI/JPI-600LB-1 1/2B
ANSI/JPI-600LB-2B
50
A, S
G1/2
17
8
B, T
1/2-14NPT
16
5
C, V
Pg13.5
8
4.5
D, W
M20 1.5
16
5
Note) Cable gland is supplied in case of flamproof packing type.
ø11 cable is suitable.
CONNECTION
DIAGRAM
Conduit conn.
J
K
M
4TH DIGIT OF THE
CODE SYMBOLS
Table 1
46
Sensor
unit
CK CK
(M4 screws)
Do not connect.
Field bus
Small frange remote seal type pressure transmitter : FDW
<With direct mount adaptor>
øF
ø84
N holes h dia.
øE
øD
Vent/drain plug
(t)
In case of ANSI/JPI-600LB
flange
(6.4)
25
(102)
Long vent/drain p lug
(added specification)
S
t
Zero ADJ. screw
In case of 4th
digit code “S,V,W”
4 holes
9 dia.
Down
88
58
ø80
ø80
Up
52.5
70
37
38
Fastener
(flameproof only)
(10)
“A” Conduit conn.2
104
MTG. pipe
JIS 50A (2B) U - bolt M8
80
105
20
Cable gland
(option) note)
“A” Conduit conn.1
237
“B” Conduit conn.
60
Detail “A”
(Conduit conn.)
Earth terminal
Electronics
unit
J
231
K
17
M
ø15
Detail “B”
(Conduit conn.)
ø13
191
43
G1/2
Sensor
unit
Table 1
4TH DIGIT OF THE
CODE SYMBOLS
A, S
CONDUIT CONN.
J
K
M
G1/2
17
8
B, T
1/2-14NPT
16
5
C, V
Pg13.5
8
4.5
D, W
M20 1.5
16
5
16th of
17th of
code symbols code symbols øD
1
1
2
2
3
3
6
6
1
1
2
2
4
4
NOTE)
1
2
1
2
1
2
1
2
H
T
H
T
H
T
95
100
95
100
115
120
120
135
89
98
95
117
95
117
11th digit of Capillary
Code symbols length : S [mm]
D, Q
E, R
L, S
øE
øF
t
N-øh
70
75
70
75
80
85
85
95
60.3
69.9
66.7
82.5
66.7
82.5
51
56
51
56
55
60
55
60
34.9
42.9
34.9
42.9
34.9
42.9
12
14
14
16
18
18
23
25
11.5
13
14.5
16
14.5
16
4-15
4-15
4-15
4-15
4-19
4-19
4-19
4-23
4-16
4-16
4-16
4-20
4-16
4-20
1500
3000
5000
70
120
Flange
JIS-10K-15A
JIS-10K-20A
JIS-20K-15A
JIS-20K-20A
JIS-30K-15A
JIS-30K-20A
JIS-63K-15A
JIS-63K-20A
ANSI/JPI-150LB 1/2B
ANSI/JPI-150LB 3/4B
ANSI/JPI-300LB 1/2B
ANSI/JPI-300LB 3/4B
ANSI/JPI-600LB 1/2B
ANSI/JPI-600LB 3/4B
50
CONNECTION
DIAGRAM
CK CK
(M4 screws)
Do not connect.
Field bus
Cable gland is supplied in case of flamproof packing type.
ø11 cable is suitable.
47
Small frange remote seal type pressure transmitter : FDW
<With direct mount adaptor (screw connection type)>
Vent/drain plug
(102)
25
Long vent/drain plug
(added specification)
ø84
Press. conn. “D”
S
20
23
Zero ADJ. screw
(10)
“A” Conduit conn.2
Fastener
(Flameproof only)
ø80
104
ø80
Up
Down
88
52.5
70
38
In case of 4th
digit code “S,V,W”
105
MTG. pipe
JIS 50A(2B)
U - bolt M8
37
Note)
4 holes
9 dia.
58
Cable gland
(option)
237
“B” Conduit conn.
“A” Conduit conn.1
Detail “A”
(Conduit conn.)
ø15
Detail “B”
(Conduit conn.)
ø13
CONNECTION
DIAGRAM
M
CK CK
60
191
43
Earth
terminal
(M4 screws)
K
17
Electronics
unit
Do not connect.
J
G1/2
231
Field bus
Table 1
CONDUIT CONN.
J
K
M
4TH DIGIT OF THE
CODE SYMBOLS
A, S
G1/2
17
8
B, T
1/2-14NPT
16
5
C, V
Pg13.5
8
4.5
D, W
M20
16
5
1.5
16th digit of
17th digit of
Code symbols Code symbols
11th digit of Capillary
Code symbols length : S [mm]
D, Q
E, R
L, S
Sensor
unit
1500
3000
5000
Press. conn."D"
S
R
Rc1/2
S
N
1/2 -14NPT
S
2
Rc3/4
S
T
3/4 -14NPT
70
120
50
Note ) Cable gland is supplied in case of
10th digit code “C”.
ø11 cable is suitable.
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Head Office
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fesys.co.jp/eng
Instrumentation Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187
http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan