ETC TFS240K

Filename: tfs 240k.doc
Version 1.5
VI TELEFILTER
16.12.2004
Filter specification
TFS 240K
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
22
02
°C
dBm
196 Ω || -8.2 pF
209 Ω || -11.3 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of TFS240K is the minimum of the pass band attenuation amin. This value is defined as the insertion
loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion
loss ae. The given values for the relative attenuation arel and the group delay ripple have to be reached at the frequencies given below, even if the centre
frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the
centre frequency fc.
Data
typ. value
6,5
Insertion loss
ae = amin
Nominal frequency
fN
-
Centre frequency
fc
240,0
Relative attenuation
arel
fN 7
MHz ... fN +
7
any 3,5 MHz interval within fN -
MHz
7 MHz... fN + 7 MHz
fN 90
30
fN 22
fN @ fN - 16
fN + 16
fN + 18
fN + 22
30
22
16
MHz
MHz
MHz
18
22
90
MHz
MHz
MHz
max. ± 1,5 dB
240,0 MHz
MHz
dB
dB
max.
max.
54
47
45
55
44
44
47
dB
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
min.
45
45
40
43
40
40
45
dB
dB
dB
dB
dB
dB
dB
Phase linearity (p-p)
within fN ± 6,3 MHz
3
deg
max.
15
deg
Group delay GD***)
within fN ± 7 MHz
0,45
µs
max.
1
µs
45
ns
max. 100
ns
Return loss at Input and Output
within fN ± 6,3 MHz
15
dB
min.
Triple transit suppression TTS
80
dB
min.
MHz ... fN MHz ... fN MHz ... fN MHz **)
MHz ... fN +
MHz ... fN +
MHz ... fN +
Group delay ripple
within fN ± 7 MHz
0,5
0,5
dB
tolerance/limit
1,4 dB
1
dB
GDR ***)
9,5 dB
45
dB
dBm
Input power level
-
20
Operating temperature range
-
- 40 °C ... + 80 °C
Storage temperature range
-
- 40 °C ... + 85 °C
Temperature coefficient of frequency
TCf
-94
ppm/K
*)
The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
**) valid for 22 °C, in the operating temperature range a relative attenuation of 41 dB is specified
***) measured with smoothing; smoothing aperture ≤ 50 kHz
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 240k.doc
Version 1.5
VI TELEFILTER
16.12.2004
Filter specification
TFS 240K
2/5
0
0.97
-1
0.91
-12
-2
0.85
-18
-3
0.79
-4
0.73
-5
0.67
-6
0.61
-42
-7
0.55
-48
-8
0.49
-54
-9
0.43
-24
-30
-36
-60
200
208
216
224
232
240
248
frequency in MHz
256
264
272
280
delay in µs
0
-6
magnitude in dB
magnitude in dB
Filter characteristic
0.37
-10
229 231.2 233.4 235.6 237.8 240 242.2 244.4 246.6 248.8 251
frequency in MHz
Construction and pin connection
(All dimensions in mm)
S 240K
●
S23
1
2
3
4
5
6
7
8
9
10
Ground
Ground
Ground
Output
Ground
Ground
Ground
Ground
Input
Ground
Date code:
S
T
U
...
Year + week
2004
2005
2006
50 Ohm Test circuit
L1
L2
9
Input
4
Output
SAW
50 Ohm
C1
50 Ohm
C2
1,2,3,5,6,7,8,10
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 240k.doc
Version 1.5
VI TELEFILTER
16.12.2004
Filter specification
TFS 240K
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,50 ± 0,1
Bo
: 7,50 ± 0,1
Ct
: 13,5 ± 0,1
t
P2
W
G
Ct
Bo
F
G
E
Do
Po
PIN Marker
Ko
Date Code
Typ
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 240k.doc
Version 1.5
VI TELEFILTER
16.12.2004
Filter specification
TFS 240K
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 240k.doc
VI TELEFILTER
Version 1.5
Filter specification
16.12.2004
TFS 240K
5/5
History
Version
Reason of Changes
Name
Date
1.0
Generation of specification according to customer requirements
E. Chilla
28.03.2003
1.1
added additional limit line at fN – 30 MHz to fN – 20 MHz
E. Chilla
16.07.2003
1.2
changed limit line value at fN – 16 MHz
E. Chilla
01.08.2003
1.3
changed construction and pin connection
E. Chilla
22.09.2003
1.4
created Filter specification
added terminating impedance
reduced max. insertion loss
increased low frequency range for 45 dB stop band attenuation
increased bandwidth for 45 dB stop band attenuation
increased high frequency near stop band attenuation
increased magnitude for triple transit suppression
added filter characteristic
changed pin 10 to ground
changed packing
E. Chilla
02.06.2004
1.5
added min. insertion loss, changed max. insertion loss
added typ. input power level, changed max. input power level
changed temperature coefficient of frequency
changed air reflow temperature conditions
changed pin 5 to ground
E. Chilla
16.12.2004
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.