TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 LOW VOLTAGE 16-BIT I2C AND SMBus I/O EXPANDER WITH INTERRUPT OUTPUT AND CONFIGURATION REGISTERS FEATURES 1 • • • • • • • Low Standby-Current Consumption of 3 µA Max I2C to Parallel Port Expander Open-Drain Active-Low Interrupt Output 5-V Tolerant I/O Ports Compatible With Most Microcontrollers 400-kHz Fast I2C Bus Address by Three Hardware Address Pins for Use of up to Eight Devices • • • • Polarity Inversion Register Latched Outputs With High-Current Drive Capability for Directly Driving LEDs Latch-Up Performance Exceeds 100 mA Per JESD 78, Class II ESD Protection Exceeds JESD 22 – 2000-V Human-Body Model (A114-A) – 200-V Machine Model (A115-A) – 1000-V Charged-Device Model (C101) 1 24 2 23 3 22 4 21 5 20 6 19 7 18 8 17 9 16 10 15 11 14 12 13 VCC SDA SCL A0 P17 P16 P15 P14 P13 P12 P11 P10 24 P00 P01 P02 P03 P04 P05 23 22 21 20 19 1 18 2 17 Exposed Center Pad 3 4 16 15 14 5 13 6 7 8 9 10 11 A0 P17 P16 P15 P14 P13 12 P06 P07 GND P10 P11 P12 INT A1 A2 P00 P01 P02 P03 P04 P05 P06 P07 GND RTW PACKAGE (TOP VIEW) A2 A1 INT VCC SDA SCL PW PACKAGE (TOP VIEW) The exposed center pad, if used, must be connected as a secondary ground or left electrically open. DESCRIPTION/ORDERING INFORMATION This 16-bit I/O expander for the two-line bidirectional bus (I2C) is designed for 1.65-V to 5.5-V VCC operation. It provides general-purpose remote I/O expansion for most microcontroller families via the I2C interface [serial clock (SCL), serial data (SDA)]. The TCA9555 consists of two 8-bit Configuration (input or output selection), Input Port, Output Port, and Polarity Inversion (active high or active low operation) registers. At power on, the I/Os are configured as inputs. The system master can enable the I/Os as either inputs or outputs by writing to the I/O configuration bits. The data for each input or output is kept in the corresponding Input or Output register. The polarity of the Input Port register can be inverted with the Polarity Inversion register. All registers can be read by the system master. The system master can reset the TCA9555 in the event of a timeout or other improper operation by utilizing the power-on reset feature, which puts the registers in their default state and initializes the I2C/SMBus state machine. The TCA9555 open-drain interrupt (INT) output is activated when any input state differs from its corresponding Input Port register state and is used to indicate to the system master that an input state has changed. 1 Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright © 2009, Texas Instruments Incorporated TCA9555 SCPS200A – JULY 2009 – REVISED JULY 2009 .............................................................................................................................................................. www.ti.com INT can be connected to the interrupt input of a microcontroller. By sending an interrupt signal on this line, the remote I/O can inform the microcontroller if there is incoming data on its ports without having to communicate via the I2C bus. Thus, the TCA9555 can remain a simple slave device. The device outputs (latched) have high-current drive capability for directly driving LEDs. Although pin-to-pin and I2C-address is compatible with the PCF8575, software changes are required due to the enhancements. The TCA9555 is identical to the TCA9535, except for the inclusion of the internal I/O pullup resistor, which pulls the I/O to a default high when configured as an input and undriven. Three hardware pins (A0, A1, and A2) are used to program and vary the fixed I2C address and allow up to eight devices to share the same I2C bus or SMBus. The fixed I2C address of the TCA9555 is the same as the PCF8575, PCF8575C, and PCF8574, allowing up to eight of these devices in any combination to share the same I2C bus or SMBus. ORDERING INFORMATION (1) PACKAGE (2) TA –40°C to 85°C (1) (2) 2 ORDERABLE PART NUMBER TOP-SIDE MARKING TSSOP – PW Reel of 2000 TCA9555PWR PW555 QFN – RTW Reel of 3000 TCA9555RTWR PW555 For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI web site at www.ti.com. Package drawings, thermal data, and symbolization are available at www.ti.com/packaging. Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 TERMINAL FUNCTIONS NO. NAME DESCRIPTION TSSOP (PW) QFN (RTW) 1 22 INT Interrupt output. Connect to VCC through a pullup resistor. 2 23 A1 Address input 1. Connect directly to VCC or ground. 3 24 A2 Address input 2. Connect directly to VCC or ground. 4 1 P00 P-port input/output. Push-pull design structure. At power on, P00 is configured as an input. 5 2 P01 P-port input/output. Push-pull design structure. At power on, P01 is configured as an input. 6 3 P02 P-port input/output. Push-pull design structure. At power on, P02 is configured as an input. 7 4 P03 P-port input/output. Push-pull design structure. At power on, P03 is configured as an input. 8 5 P04 P-port input/output. Push-pull design structure. At power on, P04 is configured as an input. 9 6 P05 P-port input/output. Push-pull design structure. At power on, P05 is configured as an input. 10 7 P06 P-port input/output. Push-pull design structure. At power on, P06 is configured as an input. 11 8 P07 P-port input/output. Push-pull design structure. At power on, P07 is configured as an input. 12 9 GND Ground 13 10 P10 P-port input/output. Push-pull design structure. At power on, P10 is configured as an input. 14 11 P11 P-port input/output. Push-pull design structure. At power on, P11 is configured as an input. 15 12 P12 P-port input/output. Push-pull design structure. At power on, P12 is configured as an input. 16 13 P13 P-port input/output. Push-pull design structure. At power on, P13 is configured as an input. 17 14 P14 P-port input/output. Push-pull design structure. At power on, P14 is configured as an input. 18 15 P15 P-port input/output. Push-pull design structure. At power on, P15 is configured as an input. 19 16 P16 P-port input/output. Push-pull design structure. At power on, P16 is configured as an input. 20 17 P17 P-port input/output. Push-pull design structure. At power on, P17 is configured as an input. 21 18 A0 Address input 0. Connect directly to VCC or ground. 22 19 SCL Serial clock bus. Connect to VCC through a pullup resistor. 23 20 SDA Serial data bus. Connect to VCC through a pullup resistor. 24 21 VCC Supply voltage Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 3 TCA9555 SCPS200A – JULY 2009 – REVISED JULY 2009 .............................................................................................................................................................. www.ti.com LOGIC DIAGRAM (POSITIVE LOGIC) TCA9555 INT A0 A1 A2 SCL SDA 1 Interrupt Logic LP Filter 21 2 P07-P00 3 22 23 Input Filter I2C Bus Control Shift Register 16 Bits I/O Port P17-P10 Write Pulse VCC GND 4 24 12 Read Pulse Power-On Reset A. Pin numbers shown are for the PW package. B. All I/Os are set to inputs at reset. Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 SIMPLIFIED SCHEMATIC OF P-PORT I/Os Data From Shift Register Output Port Register Data Configuration Register Data From Shift Register D Q FF Write Configuration Pulse VCC Q1 CLK Q Write Pulse 100 kW D Q FF I/O Pin CLK Q Output Port Register Q2 Input Port Register D Q FF Read Pulse GND Input Port Register Data CLK Q To INT Data From Shift Register D Q Polarity Register Data FF Write Polarity Pulse CLK Q Polarity Inversion Register I/O Port When an I/O is configured as an input, FETs Q1 and Q2 are off, creating a high-impedance input. The input voltage may be raised above VCC to a maximum of 5.5 V. If the I/O is configured as an output, Q1 or Q2 is enabled, depending on the state of the Output Port register. In this case, there are low-impedance paths between the I/O pin and either VCC or GND. The external voltage applied to this I/O pin should not exceed the recommended levels for proper operation. Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 5 TCA9555 SCPS200A – JULY 2009 – REVISED JULY 2009 .............................................................................................................................................................. www.ti.com I2C Interface The bidirectional I2C bus consists of the serial clock (SCL) and serial data (SDA) lines. Both lines must be connected to a positive supply via a pullup resistor when connected to the output stages of a device. Data transfer may be initiated only when the bus is not busy. I2C communication with this device is initiated by a master sending a Start condition, a high-to-low transition on the SDA input/output while the SCL input is high (see Figure 1). After the Start condition, the device address byte is sent, MSB first, including the data direction bit (R/W). This device does not respond to the general call address. After receiving the valid address byte, this device responds with an ACK, a low on the SDA input/output during the high of the ACK-related clock pulse. The address inputs (A0–A2) of the slave device must not be changed between the Start and Stop conditions. On the I2C bus, only one data bit is transferred during each clock pulse. The data on the SDA line must remain stable during the high pulse of the clock period, as changes in the data line at this time are interpreted as control commands (Start or Stop) (see Figure 2). A Stop condition, a low-to-high transition on the SDA input/output while the SCL input is high, is sent by the master (see Figure 1). Any number of data bytes can be transferred from the transmitter to the receiver between the Start and the Stop conditions. Each byte of eight bits is followed by one ACK bit. The transmitter must release the SDA line before the receiver can send an ACK bit. The device that acknowledges must pull down the SDA line during the ACK clock pulse so that the SDA line is stable low during the high pulse of the ACK-related clock period (see Figure 3). When a slave receiver is addressed, it must generate an ACK after each byte is received. Similarly, the master must generate an ACK after each byte that it receives from the slave transmitter. Setup and hold times must be met to ensure proper operation. A master receiver signals an end of data to the slave transmitter by not generating an acknowledge (NACK) after the last byte has been clocked out of the slave. This is done by the master receiver by holding the SDA line high. In this event, the transmitter must release the data line to enable the master to generate a Stop condition. SDA SCL S P Start Condition Stop Condition Figure 1. Definition of Start and Stop Conditions SDA SCL Data Line Stable; Data Valid Change of Data Allowed Figure 2. Bit Transfer 6 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 Data Output by Transmitter NACK Data Output by Receiver ACK SCL From Master 1 2 8 9 S Clock Pulse for Acknowledgment Start Condition Figure 3. Acknowledgment on I2C Bus Interface Definition BYTE BIT 7 (MSB) 6 5 4 3 2 1 0 (LSB) I2C slave address L H L L A2 A1 A0 R/W P0x I/O data bus P07 P06 P05 P04 P03 P02 P01 P00 P1x I/O data bus P17 P16 P15 P14 P13 P12 P11 P10 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 7 TCA9555 SCPS200A – JULY 2009 – REVISED JULY 2009 .............................................................................................................................................................. www.ti.com Device Address Figure 4 shows the address byte of the TCA9555. R/W Slave Address 0 1 0 0 A2 A1 A0 Fixed Programmable Figure 4. TCA9555 Address Address Reference INPUTS I2C BUS SLAVE ADDRESS A2 A1 A0 L L L 32 (decimal), 20 (hexadecimal) L L H 33 (decimal), 21 (hexadecimal) L H L 34 (decimal), 22 (hexadecimal) L H H 35 (decimal), 23 (hexadecimal) H L L 36 (decimal), 24 (hexadecimal) H L H 37 (decimal), 25 (hexadecimal) H H L 38 (decimal), 26 (hexadecimal) H H H 39 (decimal), 27 (hexadecimal) The last bit of the slave address defines the operation (read or write) to be performed. A high (1) selects a read operation, while a low (0) selects a write operation. Control Register and Command Byte Following the successful acknowledgment of the address byte, the bus master sends a command byte that is stored in the control register in the TCA9555. Three bits of this data byte state the operation (read or write) and the internal register (input, output, polarity inversion, or configuration) that will be affected. This register can be written or read through the I2C bus. The command byte is sent only during a write transmission. Once a command byte has been sent, the register that was addressed continues to be accessed by reads until a new command byte has been sent. 0 0 0 0 0 B2 B1 B0 Figure 5. Control Register Bits Command Byte CONTROL REGISTER BITS 8 B2 B1 B0 COMMAND BYTE (HEX) REGISTER PROTOCOL POWER-UP DEFAULT 0 0 0 0x00 Input Port 0 Read byte xxxx xxxx 0 0 1 0x01 Input Port 1 Read byte xxxx xxxx 0 1 0 0x02 Output Port 0 Read/write byte 1111 1111 0 1 1 0x03 Output Port 1 Read/write byte 1111 1111 1 0 0 0x04 Polarity Inversion Port 0 Read/write byte 0000 0000 1 0 1 0x05 Polarity Inversion Port 1 Read/write byte 0000 0000 1 1 0 0x06 Configuration Port 0 Read/write byte 1111 1111 1 1 1 0x07 Configuration Port 1 Read/write byte 1111 1111 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 Register Descriptions The Input Port registers (registers 0 and 1) reflect the incoming logic levels of the pins, regardless of whether the pin is defined as an input or an output by the Configuration register. It only acts on read operation. Writes to these registers have no effect. The default value, X, is determined by the externally applied logic level. Before a read operation, a write transmission is sent with the command byte to indicate to the I2C device that the Input Port register will be accessed next. Registers 0 and 1 (Input Port Registers) Bit Default Bit Default I0.7 I0.6 I0.5 I0.4 I0.3 I0.2 I0.1 X X X X X X X I0.0 X I1.7 I1.6 I1.5 I1.4 I1.3 I1.2 I1.1 I1.0 X X X X X X X X The Output Port registers (registers 2 and 3) show the outgoing logic levels of the pins defined as outputs by the Configuration register. Bit values in this register have no effect on pins defined as inputs. In turn, reads from this register reflect the value that is in the flip-flop controlling the output selection, not the actual pin value. Registers 2 and 3 (Output Port Registers) Bit Default Bit Default O0.7 O0.6 O0.5 O0.4 O0.3 O0.2 O0.1 1 1 1 1 1 1 1 O0.0 1 O1.7 O1.6 O1.5 O1.4 O1.3 O1.2 O1.1 O1.0 1 1 1 1 1 1 1 1 The Polarity Inversion registers (registers 4 and 5) allow polarity inversion of pins defined as inputs by the Configuration register. If a bit in this register is set (written with 1), the corresponding port pin's polarity is inverted. If a bit in this register is cleared (written with a 0), the corresponding port pin's original polarity is retained. Registers 4 and 5 (Polarity Inversion Registers) Bit Default Bit Default N0.7 N0.6 N0.5 N0.4 N0.3 N0.2 N0.1 N0.0 0 0 0 0 0 0 0 0 N1.7 N1.6 N1.5 N1.4 N1.3 N1.2 N1.1 N1.0 0 0 0 0 0 0 0 0 The Configuration registers (registers 6 and 7) configure the directions of the I/O pins. If a bit in this register is set to 1, the corresponding port pin is enabled as an input with a high-impedance output driver. If a bit in this register is cleared to 0, the corresponding port pin is enabled as an output. Registers 6 and 7 (Configuration Registers) Bit Default Bit Default C0.7 C0.6 C0.5 C0.4 C0.3 C0.2 C0.1 C0.0 1 1 1 1 1 1 1 1 C1.7 C1.6 C1.5 C1.4 C1.3 C1.2 C1.1 C1.0 1 1 1 1 1 1 1 1 Power-On Reset When power (from 0 V) is applied to VCC, an internal power-on reset holds the TCA9555 in a reset condition until VCC has reached VPOR. At that point, the reset condition is released and the TCA9555 registers and I2C/SMBus state machine initialize to their default states. After that, VCC must be lowered to below 0.2 V and then back up to the operating voltage for a power-reset cycle. Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 9 TCA9555 SCPS200A – JULY 2009 – REVISED JULY 2009 .............................................................................................................................................................. www.ti.com Interrupt (INT) Output An interrupt is generated by any rising or falling edge of the port inputs in the input mode. After time, tiv, the signal INT is valid. Resetting the interrupt circuit is achieved when data on the port is changed to the original setting, data is read from the port that generated the interrupt or in a Stop event. Resetting occurs in the read mode at the acknowledge (ACK) bit or not acknowledge (NACK) bit after the falling edge of the SCL signal. Interrupts that occur during the ACK or NACK clock pulse can be lost (or be very short) due to the resetting of the interrupt during this pulse. Each change of the I/Os after resetting is detected and is transmitted as INT. Reading from or writing to another device does not affect the interrupt circuit, and a pin configured as an output cannot cause an interrupt. Changing an I/O from an output to an input may cause a false interrupt to occur if the state of the pin does not match the contents of the Input Port register. Because each 8-bit port is read independently, the interrupt caused by port 0 is not cleared by a read of port 1, or vice versa. INT has an open-drain structure and requires a pullup resistor to VCC. Bus Transactions Data is exchanged between the master and the TCA9555 through write and read commands. Writes Data is transmitted to the TCA9555 by sending the device address and setting the least-significant bit to a logic 0 (see Figure 4 for device address). The command byte is sent after the address and determines which register receives the data that follows the command byte. The eight registers within the TCA9555 are configured to operate as four register pairs. The four pairs are input ports, output ports, polarity inversion ports, and configuration ports. After sending data to one register, the next data byte is sent to the other register in the pair (see Figure 6 and Figure 7). For example, if the first byte is sent to output port (register 3), the next byte is stored in Output Port 0 (register 2). There is no limitation on the number of data bytes sent in one write transmission. In this way, each 8-bit register may be updated independently of the other registers. 1 SCL 2 3 4 5 6 7 8 9 Command Byte Slave Address SDA S 0 1 0 0 A2 A1 A0 0 A 0 0 0 0 0 0 Data to Port 0 1 R/W Acknowledge From Slave Start Condition 0.7 A 0 Data to Port 1 0.0 Data 0 Acknowledge From Slave A 1.7 1.0 Data 1 A P Acknowledge From Slave Write to Port Data Out from Port 0 tpv Data Valid Data Out from Port 1 tpv Figure 6. Write to Output Port Registers 1 SCL 2 3 4 5 6 7 8 9 1 2 3 Slave Address SDA S 0 1 0 Start Condition 0 A2 A1 A0 4 5 6 7 8 9 1 2 3 Command Byte 0 R/W A 0 0 0 Acknowledge From Slave 0 0 1 1 4 5 6 7 8 9 1 2 3 Data to Register 0 A MSB Data 0 4 5 Data to Register LSB Acknowledge From Slave A MSB Data 1 LSB A P Acknowledge From Slave Figure 7. Write to Configuration Registers 10 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 Reads The bus master first must send the TCA9555 address with the least-significant bit set to a logic 0 (see Figure 4 for device address). The command byte is sent after the address and determines which register is accessed. After a restart, the device address is sent again, but this time, the least-significant bit is set to a logic 1. Data from the register defined by the command byte then is sent by the TCA9555 (see Figure 8 through Figure 10). After a restart, the value of the register defined by the command byte matches the register being accessed when the restart occurred. For example, if the command byte references Input Port 1 before the restart, and the restart occurs when Input Port 0 is being read, the stored command byte changes to reference Input Port 0. The original command byte is forgotten. If a subsequent restart occurs, Input Port 0 is read first. Data is clocked into the register on the rising edge of the ACK clock pulse. After the first byte is read, additional bytes may be read, but the data now reflect the information in the other register in the pair. For example, if Input Port 1 is read, the next byte read is Input Port 0. Data is clocked into the register on the rising edge of the ACK clock pulse. There is no limitation on the number of data bytes received in one read transmission, but when the final byte is received, the bus master must not acknowledge the data. Slave Address S 0 1 0 0 A2 Acknowledge From Slave A1 A0 0 Slave Address Acknowledge From Slave Command Byte A A R/W S 0 1 0 0 Data From Lower or Upper Byte of Register Acknowledge From Slave A2 A1 A0 1 Data A MSB LSB A First Byte R/W At this moment, master transmitter becomes master receiver, and slave-receiver becomes slave-transmitter. Acknowledge From Master Data From Upper or Lower Byte of Register MSB No Acknowledge From Master LSB NA Data P Last Byte Figure 8. Read From Register 1 SCL 2 3 4 5 6 7 8 9 I0.x SDA S 0 1 0 0 A2 A1 A0 1 A 7 6 5 4 Acknowledge R/W From Slave 3 I1.x 2 1 0 A 7 6 5 Acknowledge From Master 4 3 I0.x 2 1 0 A 7 6 5 4 3 I1.x 2 1 0 A 7 6 5 4 3 2 1 Acknowledge From Master Acknowledge From Master 0 1 P No Acknowledge From Master Read From Port 0 Data Into Port 0 Read From Port 1 Data Into Port 1 INT tiv tir A. Transfer of data can be stopped at any time by a Stop condition. When this occurs, data present at the latest acknowledge phase is valid (output mode). It is assumed that the command byte previously has been set to 00 (read Input Port register). B. This figure eliminates the command byte transfer, a restart, and slave address call between the initial slave address call and actual data transfer from the P port (see Figure 8 for these details). Figure 9. Read Input Port Register, Scenario 1 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 11 TCA9555 SCPS200A – JULY 2009 – REVISED JULY 2009 .............................................................................................................................................................. www.ti.com 1 SCL 2 3 4 5 6 7 8 9 I0.x SDA S 0 1 0 0 A2 A1 A0 1 R/W A 00 Acknowledge From Slave I1.x A 10 I0.x A 03 Acknowledge From Master Acknowledge From Master I1.x A 12 P No Acknowledge From Master tps tph 1 Acknowledge From Master Read From Port 0 Data Into Port 0 Data 00 Data 01 Data 02 Data 03 tph tps Read From Port 1 Data 10 Data Into Port 1 Data 11 Data 12 INT tiv tir A. Transfer of data can be stopped at any time by a Stop condition. When this occurs, data present at the latest acknowledge phase is valid (output mode). It is assumed that the command byte previously has been set to 00 (read Input Port register). B. This figure eliminates the command byte transfer, a restart, and slave address call between the initial slave address call and actual data transfer from the P port (see Figure 8 for these details). Figure 10. Read Input Port Register, Scenario 2 12 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 ABSOLUTE MAXIMUM RATINGS (1) over operating free-air temperature range (unless otherwise noted) MIN MAX VCC Supply voltage range –0.5 6 V VI Input voltage range (2) –0.5 6 V (2) VO Output voltage range IIK Input clamp current VI < 0 –20 mA IOK Output clamp current VO < 0 –20 mA IIOK Input/output clamp current VO < 0 or VO > VCC ±20 mA IOL Continuous output low current VO = 0 to VCC 50 mA IOH Continuous output high current VO = 0 to VCC –50 mA ICC –0.5 Continuous current through GND –250 Continuous current through VCC 160 θJA Package thermal impedance, junction to free air (3) Tstg Storage temperature range (1) (2) (3) 6 UNIT PW package 88 RTW package 66 –65 150 V mA °C/W °C Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed. The package thermal impedance is calculated in accordance with JESD 51-7. RECOMMENDED OPERATING CONDITIONS VCC MIN MAX 1.65 5.5 SCL, SDA 0.7 × VCC 5.5 A2–A0, P07–P00, P17–P10 0.7 × VCC 5.5 SCL, SDA –0.5 0.3 × VCC A2–A0, P07–P00, P17–P10 –0.5 0.3 × VCC Supply voltage VIH High-level input voltage VIL Low-level input voltage IOH High-level output current P07–P00, P17–P10 IOL Low-level output current P07–P00, P17–P10 TA Operating free-air temperature –40 Product Folder Link(s): TCA9555 V V V –10 mA 25 mA 85 °C Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated UNIT 13 TCA9555 SCPS200A – JULY 2009 – REVISED JULY 2009 .............................................................................................................................................................. www.ti.com ELECTRICAL CHARACTERISTICS over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS VCC MIN –1.2 VIK Input diode clamp voltage II = –18 mA 1.65 V to 5.5 V VPOR Power-on reset voltage VI = VCC or GND, IO = 0 1.65 V to 5.5 V IOH = –8 mA P-port high-level output voltage (2) VOH IOH = –10 mA 1.65 V 1.2 2.3 V 1.8 3V 2.6 4.75 V 4.1 1.65 V 1.8 2.3 V 1.7 3V 2.5 4.75 V SDA P port (3) IOL VOL = 0.7 V INT II A2–A0 1.5 1.65 UNIT V V V 3 1.65 V to 5.5 V VOL = 0.4 V SCL, SDA MAX 4 VOL = 0.4 V VOL = 0.5 V TYP (1) 8 20 10 24 mA 3 VI = VCC or GND 1.65 V to 5.5 V ±1 ±1 µA IIH P port VI = VCC 1.65 V to 5.5 V 1 µA IIL P port VI = GND 1.65 V to 5.5 V –100 µA Operating mode VI = VCC or GND, IO = 0, I/O = inputs, fSCL = 400 kHz, No load ICC Low inputs VI = GND, IO = 0, I/O = inputs, fSCL = 0 kHz, No load Standby mode High inputs VI = VCC, IO = 0, I/O = inputs, fSCL = 0 kHz, No load 5.5 V 100 200 3.6 V 30 75 2.7 V 20 50 1.95 V 10 45 5.5 V 1.1 1.5 3.6 V 0.7 1.3 2.7 V 0.5 1 1.95 V 0.3 0.9 5.5 V 2.5 3 3.6 V 2 2.6 2.7 V 1.5 2.5 1.95 V 1.2 2.3 ΔICC Additional current in standby mode One input at VCC – 0.6 V, Other inputs at VCC or GND 1.65 V to 5.5 V CI SCL VI = VCC or GND 1.65 V to 5.5 V Cio (1) (2) (3) 14 SDA P port VIO = VCC or GND 1.65 V to 5.5 V µA mA µA 1.5 mA 3 7 pF 3 7 3.7 9.5 pF All typical values are at nominal supply voltage (1.8-V, 2.5-V, 3.3-V, or 5-V VCC) and TA = 25°C. Each I/O must be externally limited to a maximum of 25 mA, and each octal (P07–P00 and P17–P10) must be limited to a maximum current of 100 mA, for a device total of 200 mA. The total current sourced by all I/Os must be limited to 160 mA (80 mA for P07–P00 and 80 mA for P17–P10). Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 I2C INTERFACE TIMING REQUIREMENTS over recommended operating free-air temperature range (unless otherwise noted) (see Figure 11) fscl I2C clock frequency tsch I2C clock high time I C clock low time tsp I2C spike time tsds I2C serial-data setup time MAX UNIT 0 400 kHz µs 0.6 2 tscl MIN µs 1.3 50 100 2 ns ns tsdh I C serial-data hold time ticr I2C input rise time 20 + 0.1Cb 300 ns ticf I2C input fall time 20 + 0.1Cb 300 ns 20 + 0.1Cb 300 2 0 10-pF to 400-pF bus ns tocf I C output fall time tbuf I2C bus free time between Stop and Start 1.3 µs tsts I2C Start or repeated Start condition setup 0.6 µs tsth I2C Start or repeated Start condition hold 0.6 µs 0.6 µs 2 tsps I C Stop condition setup tvd(Data) Valid-data time SCL low to SDA output valid 50 tvd(ack) Valid-data time of ACK condition ACK signal from SCL low to SDA (out) low 0.1 Cb I2C bus capacitive load ns ns 0.9 µs 400 pF SWITCHING CHARACTERISTICS over recommended operating free-air temperature range, CL ≤ 100 pF (unless otherwise noted) (see Figure 12 and Figure 13) PARAMETER FROM (INPUT) TO (OUTPUT) P port INT 4 µs SCL INT 4 µs 200 ns MIN MAX UNIT tiv Interrupt valid time tir Interrupt reset delay time tpv Output data valid SCL P port tps Input data setup time P port SCL 150 ns tph Input data hold time P port SCL 1 µs Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 15 TCA9555 SCPS200A – JULY 2009 – REVISED JULY 2009 .............................................................................................................................................................. www.ti.com TYPICAL CHARACTERISTICS TA = 25°C (unless otherwise noted) SUPPLY CURRENT vs TEMPERATURE STANDBY SUPPLY CURRENT vs TEMPERATURE 55 70 30 SCL = V CC 50 V CC = 5 V ICC – Supply Current – nA 40 f SCL = 400 kHz I/Os Unloaded 35 30 25 V CC = 3.3 V 20 15 10 V CC = 2.5 V 5 0 -50 f SCL = 400 kHz I/Os Unloaded 60 25 ICC – Supply Current – µA 45 ICC – Supply Current – µA SUPPLY CURRENT vs SUPPLY VOLTAGE 20 V CC = 5 V 15 V CC = 3.3 V 10 40 30 20 10 V CC = 2.5 V 5 50 0 -25 0 25 50 75 0 -50 100 TA – Free-Air Tem perature – °C 2.3 -25 0 25 50 75 2.7 3.1 100 3.5 3.9 4.3 4.7 5.1 5.5 V CC – Supply Voltage – V TA – Free-Air Tem perature – °C I/O SINK CURRENT vs OUTPUT LOW VOLTAGE I/O SINK CURRENT vs OUTPUT LOW VOLTAGE 30 50 40 V CC = 3.3 V V CC = 2.5 V TA = –40°C 20 TA = 25°C 15 10 TA = 125°C 25 TA = 25°C 20 15 10 TA = 125°C 5 5 0.1 0.2 0.3 0.4 0.5 0.1 I/O OUTPUT LOW VOLTAGE vs TEMPERATURE ISOURCE – I/O Source Current – mA V OL – Output Low Voltage – mV 0.3 0.4 0.5 200 V CC = 5 V, ISINK = 10 m A 150 125 100 V CC = 2.5 V, ISINK = 1 m A 50 V CC = 5 V, ISINK = 1 m A 25 15 10 TA = 125°C 0.0 0.1 0.2 0.3 0.4 0.5 0.6 V OL – Output Low Voltage – V I/O SOURCE CURRENT vs OUTPUT HIGH VOLTAGE 50 TA = –40°C 25 TA = 25°C 20 V CC = 3.3 V 45 30 15 10 TA = 125°C 5 TA = –40°C 40 35 TA = 25°C 30 25 20 15 10 TA = 125°C 5 0 0.0 -25 0 25 50 75 100 0.1 0.2 0.3 0.4 0.5 0.6 (V CC – V OH) – V 0.7 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 (V CC – V OH) – V TA – Free-Air Tem perature – °C 16 0.6 V CC = 2.5 V 225 0 -50 0.2 35 V CC = 2.5 V, ISINK = 10 m A 250 75 20 I/O SOURCE CURRENT vs OUTPUT HIGH VOLTAGE 300 175 25 V OL – Output Low Voltage – V V OL – Output Low Voltage – V 275 TA = 25°C 30 0 0.0 0.6 ISOURCE – I/O Source Current – mA 0.0 35 5 0 0 TA = –40°C 40 30 ISINK – I/O Sink Current – mA ISINK – I/O Sink Current – mA TA = –40°C V CC = 5 V 45 35 25 ISINK – I/O Sink Current – mA I/O SINK CURRENT vs OUTPUT LOW VOLTAGE Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 TYPICAL CHARACTERISTICS (continued) TA = 25°C (unless otherwise noted) I/O SOURCE CURRENT vs OUTPUT HIGH VOLTAGE SUPPLY CURRENT vs NUMBER OF I/Os HELD LOW 300 V CC = 5 V V OH – Output High Voltage – mV TA = 25°C 35 30 25 20 15 TA = 125°C 10 5 0 0.0 0.1 0.2 0.3 0.4 1100 250 TA = –40°C 60 55 50 45 40 1200 275 0.5 0.6 225 200 175 150 V CC = 5 V, IOL = 10 m A 125 100 75 800 700 600 TA = 25°C 500 400 300 200 25 100 TA = 125°C 0 0 -50 (V CC – V OH) – V TA = –40°C 900 50 0.7 V CC = 5 V 1000 V CC = 2.5 V, IOL = 10 m A ICC – Supply Current – µA 75 70 65 ISOURCE – I/O Source Current – mA I/O HIGH VOLTAGE vs TEMPERATURE -25 0 25 50 75 100 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Num ber of I/Os Held Low TA – Free-Air Tem perature – °C OUTPUT HIGH VOLTAGE vs SUPPLY VOLTAGE 6 V OH – Output High Voltage – V TA = 25°C 5 4 IOH = –8 m A 3 IOH = –10 m A 2 1 0 2.3 2.7 3.1 3.5 3.9 4.3 4.7 5.1 5.5 V CC – Supply Voltage – V Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 17 TCA9555 SCPS200A – JULY 2009 – REVISED JULY 2009 .............................................................................................................................................................. www.ti.com PARAMETER MEASUREMENT INFORMATION VCC RL = 1 kΩ SDA DUT CL = 50 pF SDA LOAD CONFIGURATION Three Bytes for Complete Device Programming Stop Condition (P) Start Address Address Condition Bit 7 Bit 6 (S) (MSB) Address Bit 1 tscl R/W Bit 0 (LSB) ACK (A) Data Bit 07 (MSB) Data Bit 10 (LSB) Stop Condition (P) tsch 0.7 × VCC SCL 0.3 × VCC ticr ticf tbuf tsts tPHL tPLH tsp 0.7 × VCC SDA 0.3 × VCC ticf ticr tsth tsdh tsds tsps Repeat Start Condition Start or Repeat Start Condition Stop Condition VOLTAGE WAVEFORMS BYTE DESCRIPTION 1 I2C address 2, 3 P-port data A. CL includes probe and jig capacitance. B. All inputs are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr/tf ≤ 30 ns. C. All parameters and waveforms are not applicable to all devices. Figure 11. I2C Interface Load Circuit and Voltage Waveforms 18 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 PARAMETER MEASUREMENT INFORMATION (continued) VCC RL = 4.7 kΩ INT DUT CL = 100 pF INTERRUPT LOAD CONFIGURATION ACK From Slave Start Condition 16 Bits (Two Data Bytes) From Port R/W Slave Address (PCA9555) S 0 1 0 0 A2 A1 A0 1 A 1 2 3 4 A 5 6 7 8 Data 1 ACK From Slave Data 2 Data From Port A Data 3 1 P A tir tir B B INT A tiv tsps A Data Into Port Address Data 1 0.7 × VCC INT 0.3 × VCC SCL Data 2 Data 3 0.7 × VCC R/W tiv A 0.3 × VCC tir 0.7 × VCC Pn 0.7 × VCC INT 0.3 × VCC 0.3 × VCC View A−A View B−B A. CL includes probe and jig capacitance. B. All inputs are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr/tf ≤ 30 ns. C. All parameters and waveforms are not applicable to all devices. Figure 12. Interrupt Load Circuit and Voltage Waveforms Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 19 TCA9555 SCPS200A – JULY 2009 – REVISED JULY 2009 .............................................................................................................................................................. www.ti.com PARAMETER MEASUREMENT INFORMATION (continued) DUT Pn CL = 100 pF GND P-PORT LOAD CONFIGURATION 0.7 × VCC SCL P00 A P17 0.3 × VCC Slave ACK ÎÎÎ ÎÎÎ ÎÎÎ ÎÎÎ SDA Pn tpv (see Note A) Unstable Data Last Stable Bit WRITE MODE (R/W = 0) 0.7 × VCC SCL P00 A tps P17 0.3 × VCC tph 0.7 × VCC Pn 0.3 × VCC READ MODE (R/W = 1) A. CL includes probe and jig capacitance. B. tpv is measured from 0.7 × VCC on SCL to 50% I/O (Pn) output. C. All inputs are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr/tf ≤ 30 ns. D. The outputs are measured one at a time, with one transition per measurement. E. All parameters and waveforms are not applicable to all devices. Figure 13. P-Port Load Circuit and Voltage Waveforms 20 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 PARAMETER MEASUREMENT INFORMATION (continued) VCC RL = 1 kΩ DUT SDA DUT CL = 100 pF CL = 50 pF SDA LOAD CONFIGURATION Pn P-PORT LOAD CONFIGURATION Start SCL ACK or Read Cycle SDA 0.3 y VCC tREC RESET VCC/2 tREC tw Pn VCC/2 tRESET A. CL includes probe and jig capacitance. B. All inputs are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr/tf ≤ 30 ns. C. The outputs are measured one at a time, with one transition per measurement. D. I/Os are configured as inputs. E. All parameters and waveforms are not applicable to all devices. Figure 14. Reset Load Circuits and Voltage Waveforms Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 21 TCA9555 SCPS200A – JULY 2009 – REVISED JULY 2009 .............................................................................................................................................................. www.ti.com APPLICATION INFORMATION Figure 15 shows an application in which the TCA9555 can be used. Subsystem 1 (e.g., Temperature Sensor) INT VCC (5 V) VCC 10 kΩ 10 kΩ 10 kΩ 24 Ω 10 kΩ 22 SCL Master Controller SDA 23 1 INT Subsystem 2 (e.g., Counter) 2 kΩ VCC SCL SDA INT P00 P01 P02 P03 GND P04 P05 RESET 4 5 A 6 7 ENABLE 8 9 B TCA9555 VCC P06 P07 3 A2 P10 P11 2 A1 P12 P13 21 A0 P14 P15 P16 GND P17 12 A. Device address is configured as 0100100 for this example. B. P00, P02, and P03 are configured as outputs. C. P01, P04–P07, and P10–P17 are configured as inputs. D. Pin numbers shown are for the PW package. 10 11 13 14 15 16 17 18 19 20 Controlled Switch (e.g., CBT Device) ALARM Keypad Subsystem 3 (e.g., Alarm) Figure 15. Typical Application 22 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 Minimizing ICC When I/O Is Used to Control LED When an I/O is used to control an LED, normally it is connected to VCC through a resistor as shown in Figure 15. Because the LED acts as a diode, when the LED is off, the I/O VIN is about 1.2 V less than VCC. The ΔICC parameter in Electrical Characteristics shows how ICC increases as VIN becomes lower than VCC. For battery-powered applications, it is essential that the voltage of I/O pins is greater than or equal to VCC when the LED is off to minimize current consumption. Figure 16 shows a high-value resistor in parallel with the LED. Figure 17 shows VCC less than the LED supply voltage by at least 1.2 V. Both of these methods maintain the I/O VIN at or above VCC and prevent additional supply current consumption when the LED is off. VCC LED 100 kW VCC Pn Figure 16. High-Value Resistor in Parallel With LED 3.3 V VCC 5V LED Pn Figure 17. Device Supplied by Lower Voltage Power-On Reset Requirements In the event of a glitch or data corruption, TCA9555 can be reset to its default conditions by using the power-on reset feature. Power-on reset requires that the device go through a power cycle to be completely reset. This reset also happens when the device is powered on for the first time in an application. The two types of power-on reset are shown in Figure 18 and Figure 19. VCC Ramp-Up Ramp-Down Re-Ramp-Up VCC_TRR_GND Time VCC_RT VCC_FT Time to Re-Ramp VCC_RT Figure 18. VCC is Lowered Below 0.2 V or 0 V and Then Ramped Up to VCC Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 23 TCA9555 SCPS200A – JULY 2009 – REVISED JULY 2009 .............................................................................................................................................................. www.ti.com VCC Ramp-Down Ramp-Up VCC_TRR_VPOR50 VIN drops below POR levels Time Time to Re-Ramp VCC_FT VCC_RT Figure 19. VCC is Lowered Below the POR Threshold, Then Ramped Back Up to VCC Table 1 specifies the performance of the power-on reset feature for TCA9555 for both types of power-on reset. Table 1. RECOMMENDED SUPPLY SEQUENCING AND RAMP RATES (1) MAX UNIT VCC_FT Fall rate PARAMETER See Figure 18 0.1 2000 ms VCC_RT Rise rate See Figure 18 0.1 2000 ms VCC_TRR_GND Time to re-ramp (when VCC drops to GND) See Figure 18 1 µs VCC_TRR_POR50 Time to re-ramp (when VCC drops to VPOR_MIN – 50 mV) See Figure 19 1 µs VCC_GH Level that VCCP can glitch down to, but not cause a functional disruption when VCCX_GW = 1 µs See Figure 20 1.2 V VCC_GW Glitch width that will not cause a functional disruption when VCCX_GH = 0.5 × VCCx See Figure 20 10 µs VPORF Voltage trip point of POR on falling VCC VPORR Voltage trip point of POR on rising VCC (1) MIN TYP 0.7 V 1.4 V TA = –40°C to 85°C (unless otherwise noted) Glitches in the power supply can also affect the power-on reset performance of this device. The glitch width (VCC_GW) and height (VCC_GH) are dependent on each other. The bypass capacitance, source impedance, and device impedance are factors that affect power-on reset performance. Figure 20 and Table 1 provide more information on how to measure these specifications. VCC VCC_GH Time VCC_GW Figure 20. Glitch Width and Glitch Height VPOR is critical to the power-on reset. VPOR is the voltage level at which the reset condition is released and all the registers and the I2C/SMBus state machine are initialized to their default states. The value of VPOR differs based on the VCC being lowered to or from 0. Figure 21 and Table 1 provide more details on this specification. 24 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 TCA9555 www.ti.com .............................................................................................................................................................. SCPS200A – JULY 2009 – REVISED JULY 2009 VCC VPOR VPORF Time POR Time Figure 21. VPOR Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TCA9555 25 PACKAGE OPTION ADDENDUM www.ti.com 17-Jul-2009 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Eco Plan (2) Qty TCA9555PWR ACTIVE TSSOP PW 24 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TCA9555RTWR ACTIVE QFN RTW 24 3000 Green (RoHS & no Sb/Br) CU NIPDAU Level-2-260C-1 YEAR Lead/Ball Finish MSL Peak Temp (3) (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com 2-Jul-2009 TAPE AND REEL INFORMATION *All dimensions are nominal Device Package Package Pins Type Drawing SPQ Reel Reel Diameter Width (mm) W1 (mm) A0 (mm) B0 (mm) K0 (mm) P1 (mm) W Pin1 (mm) Quadrant TCA9555PWR TSSOP PW 24 2000 330.0 16.4 6.95 8.3 1.6 8.0 16.0 Q1 TCA9555RTWR QFN RTW 24 3000 330.0 12.4 4.3 4.3 1.5 8.0 12.0 Q2 Pack Materials-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com 2-Jul-2009 *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) TCA9555PWR TCA9555RTWR TSSOP PW 24 2000 346.0 346.0 33.0 QFN RTW 24 3000 346.0 346.0 29.0 Pack Materials-Page 2 MECHANICAL DATA MTSS001C – JANUARY 1995 – REVISED FEBRUARY 1999 PW (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE 14 PINS SHOWN 0,30 0,19 0,65 14 0,10 M 8 0,15 NOM 4,50 4,30 6,60 6,20 Gage Plane 0,25 1 7 0°– 8° A 0,75 0,50 Seating Plane 0,15 0,05 1,20 MAX PINS ** 0,10 8 14 16 20 24 28 A MAX 3,10 5,10 5,10 6,60 7,90 9,80 A MIN 2,90 4,90 4,90 6,40 7,70 9,60 DIM 4040064/F 01/97 NOTES: A. B. C. D. All linear dimensions are in millimeters. This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusion not to exceed 0,15. Falls within JEDEC MO-153 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Amplifiers Data Converters DLP® Products DSP Clocks and Timers Interface Logic Power Mgmt Microcontrollers RFID RF/IF and ZigBee® Solutions amplifier.ti.com dataconverter.ti.com www.dlp.com dsp.ti.com www.ti.com/clocks interface.ti.com logic.ti.com power.ti.com microcontroller.ti.com www.ti-rfid.com www.ti.com/lprf Applications Audio Automotive Broadband Digital Control Medical Military Optical Networking Security Telephony Video & Imaging Wireless www.ti.com/audio www.ti.com/automotive www.ti.com/broadband www.ti.com/digitalcontrol www.ti.com/medical www.ti.com/military www.ti.com/opticalnetwork www.ti.com/security www.ti.com/telephony www.ti.com/video www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2009, Texas Instruments Incorporated