DC-AC INVERTER UNIT - Power

DC-AC INVERTER UNIT
PS-INVC901(S) (32 W SIX FOLD OUTPUTS)
DESCRIPTION :
This low profile DC to AC Inverter is developed for six fold lamps.
Optimized for Hitachi: TX48D21VM0CAA
APPLICABLE LCD:
19 inches six fold lamp type
Lamp Voltage 770 Vrms
Lamp Current 6 x 6.5 mArms
Lamp Start Up Voltage 1.700 Vrms (Vin : 24 Vdc)
Picture is coming soon
FEATURES :
Remote ON/OFF
CCFL-Fail-Signal
Open Lamp Detection
RoHS compliant (S)
Under Voltage Protection for Vin
2x input capacitors Sanyo Polymer
4x input capacitors Lelon VCH SMD
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
0°C ~ +60°C
-20°C ~ +85°C
95 %RH max
190 x 70 x 11 mm
Unit : mm
Weight : 87 (g) typ.
Components
No.
1
2
4
Part Description
PCB
Connector CN1
Connector CN3 + CN5
Connector CN2 + CN4
Qty.
1
1
2
2
Material
UL94V-0 (FR-4 or CEM-3)
S10B-PH-K
SM02B-BHSS-1-TB
SM04(9-E2)B-BHS-1-TB
Note
t=1.6 mm
JST or equiv
JST or equiv
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.1. 17th September 2010
DC-AC INVERTER UNIT
PS-INVC901(S) (32 W SIX FOLD OUTPUTS)
Output side CN3 + CN5
Pin No.
Symbols
Ratings
Vhigh
770
Vrms
(6.5 mArms)
CN 3+5-1
Vlow
CCFL RTN
CN 3+5-2
Input side CN1:
Pin No.
Symbols
Ratings
Vin
21.6
~ 26.4 Vdc
CN 1-1
Vin
21.6 ~ 26.4 Vdc
CN 1-2
Vin
21.6 ~ 26.4 Vdc
CN 1-3
GND
CN 1-4
GND
CN 1-5
GND
CN 1-6
NC
CN 1-7
Vrmt
0 ~ 0.5 = OFF / 2.5 ~ 5.5 = ON
CN 1-8
Ext. PWM 0 ~ 1.5 = OFF / 3.3 ~ 5.5 = ON
CN 1-9
CCFL
CN 1-10
Output side CN2 + CN4
CCFL-Fail
Pin No.
CN 2+4-1
CN 2+4-2
CN 2+4-3
CN 2+4-4
Symbols
VHIGH1
VHIGH2
VLOW
Vlow
Ratings
770 Vrms (6.5 mArms)
770 Vrms (6.5 mArms)
NC
CCFL RTN 1
CN 2+4-5
Vlow
CCFL RTN 2
ELECTRICAL CHARACTERISTICS
Conditions
Parameters
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No load Shutdown
Note 1:
Note 2:
Note 3:
Note 4:
Note 6:
Symbols
Specification
Unit
Note
7.0
mArms
Vin = 24 Vdc
Dut y = 100%
10
1.00
53
1.700
1.35
57
2.000
%
Adc
kHz
Vrms
-
-
sec
Vin (V)
Tu (°C)
Min.
Typ.
Max.
Iout
24±2.4
0 ~ +60
6.0
6.5
Iout
Iin
F
Vopen
24±1.2
24±2.4
24±2.4
24.0
0 ~ +60
0 ~ +60
0 ~ +60
0 ~ +60
0.70
50
1.550
Tsd
24±2.4
0 ~ +60
1.0
without load
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as
marked on mechanical drawing and any conductors.
In case one lamp has a problem, the inverter switch off only the output side with the defect bulb.
External PWM-Signal is high activ.
CCFL Fail create a TTL-signal if one or more bulbs have a failure (TTL 3,3 ~ 5 V)
Frequency for ext. PWM 100Hz ~ 1kHz
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.0.1. 17th September 2010
DC-AC INVERTER UNIT
PS-INVC901(S) (32 W SIX FOLD OUTPUTS)
TEST CIRCUIT :
F
Vin
24 V
A
Iin
1000:1
PROBE
F
CN2-1
CN1-1
CN1-2
CN1-3
V
Vopen V
~
SW3
CL1
RL1
CN2-2
A Iout
1
~
SW4
SW5
CN3-1
CN1-4
CN1-5
CN1-6
CN3-2 SW6
A
~
CL3
Iout
3
A
~
CL4
Iout
4
A
~
CL5
Iout
5
A
~
CL6
Iout
6
SW7
CN4-1
N.C.
A
~
CL2
Iout
2
RL2
T1
CN1-7
RL3
SW8
CN4-2
SW9
CN5-1
RL4
Vrmt
0.4 / 5 Vdc
Brightness PWM
100% = max. Brightness
0% = min. Brightness
100 ~ 1.000 Hz recomended
250 Hz
a
V
b
SW1
CN1-8
CN5-2 SW10
SW11
CN6-1
RL5
CN1-9
TTL-Level
CN6-2 SW12
SW13
CN7-1
RL6
CN7-2 SW14
CCFL Fail
CN1-10
CCFL ok => 2,4 V
CCFL fail =< 0,8 V
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (3)
Version 1.0.1. 17th September 2010