Tfs326A.doc version 1.8 VI TELE FILTER 14.05.01 Filter Specification TFS 326A 1/5 Measurement condition 23 °C 0 dBm Input: Output Ambient temperature: Input power level: Terminating impedance: 237 Ω -0.30 pF 237 Ω -0.30 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 326A is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 326,4 MHz without tolerance. Data typ. Value Insertion loss (Reference level) ae = amin Nominal frequency fN Centre frequency fc Pass band ripple within fN ± 2,50 tolerance /limit 2,6 dB max. 4,5 - 326,4 326,4 MHz MHz 3 dB Bandwidth MHz - - max. 0,8 dB - min. 14,0 MHz - max. 0,8 max. 3,0 min. 11,0 min. 15,0 min. 13,0 min. 15,0 min. 11,0 min. 15,0 min. 25,0 min. 25,0 dB dB dB dB dB dB dB dB dB dB Relative attenuation fN ..... MHz fN ± 2,5 fN + 12,5 MHz fN + 13,28 MHz fN + 14,85 MHz MHz fN +18,9 MHz fN - 12,5 fN - 13,75 MHz MHz fN - 30,0 MHz fN +40,0 arel MHz fN ± 2,5 fN ± 7,0 MHz fN + 13,28 MHz fN + 14,85 MHz fN + 18,9 MHz fN + 40,0 MHz fN – 13,75 MHz fN – 30,0 MHz fN - 316,4 MHz fN + 123,6 MHz dB Group delay ripple within ± 2,50 MHz - max 40,0 ns Group delay ripple within ± 7,0 MHz - max.100,0 ns Return loss within ± 2,50 MHz min. 12,0 dB Return loss within ± 7,0 MHz - min. dB - max. 15,0 Input power level 8,0 dBm * Operating temperature range - 10 °C ... + 80 °C Storage temperature range - 40 °C ... + 85 °C Temperature coefficient of frequency TCf T.B.D.(ca. - 72 ppm/K) - *) peaks with 20 dBm allowed for 1:100 duty cycle Generated: Checked / Approved: VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 0075 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs326A.doc version 1.8 VI TELE FILTER 18.10.2002 Filter Specification TFS 326A 2/5 Construction and pin connection 5.0 SQ 7 +0.15 -0.1 5 326A N24 1 3 Date code Pin 1 Pin 2 Pin 3 Pin 4 Ground Ground Output Ground Pin 5 Pin 6 Pin 7 Pin 8 M Ground Ground Input Ground (pin with slanted edge) Date code: Year+week L 1999 2000 N 2001 ... 50 Ω test circut 1 L1 IN 7 C1 L2 3 SAW C2 OUT 1,2,4,5,6,8 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs326A.doc version 1.8 VI TELE FILTER 18.10.2002 Filter Specification TFS 326A 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer Tape (all dimensions in mm) W : 12 EMBOSSED CARRIER TAPE ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,5 E : 1,75 ± 0,1 F : 5,5 ± 0,1 G (min) : 0,75 P2 : 2 ± 0,05 P1 : 8 ± 0,1 D1(min) : 1,5 Ao Bo : : 5,3 ± 0,1 5,3 ± 0,1 CT : 9,5 3000 min 300 mm min 500 mm min 300 mm D o Po P 2 E A o F D CT B 1 W o G ± 0,1 P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 : W2 (max) : 330 12,4 ± 2,0 18,4 N (min) : 50 C : 13 ± 0.2 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs326A.doc version 1.8 VI TELE FILTER 18.10.2002 Filter Specification TFS 326A 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods main-heating periods 150 °C - 170 °C over 200 °C 110 sec. - 140 sec. 60 sec. - 65 sec. peak temperature 230 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time for the given air reflow profile Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 21 21 25 41 80 109 124 134 141 147 150 153 153 153 time / sec. 140 150 160 170 180 190 200 210 220 230 240 250 260 270 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] temperature / °C 153 155 157 159 161 162 163 164 166 168 171 173 176 178 time / sec. 280 290 300 310 320 330 340 350 360 370 380 390 temperature / °C 182 189 200 205 208 211 213 213 210 203 188 168 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs326A.doc version 1.8 VI TELE FILTER Version 18.10.2002 Filter Specification TFS 326A Reason of Changes 5/5 Name Date 1.0 - generate according customer requirement specification Dr. Sabah 10.08.2000 1.1 - Groupe delay ripple within: ± 7,50 MHz Max. 90 ns Dr. Sabah 21.08.2000 1.2 - Return loss within: ± 2,50 MHz - Return loss within: ± 7,50 MHz Max. 10 dB Max. 6,5 dB Dr. Sabah 31.08.2000 1.3 - Pin connection changed : pin 9 input; pin 3 output Dr. Sabah 31.08.2000 1.4 - Add preliminary values for terminating impedance Dr. Sabah 11.10.2000 1.5 - changing of 3dB bandwidth to ± 7,0 MHz - changing of package to 5X5 Dr. Sabah 06.11.2000 1.6 - changing of Return loss to –12dB (within: ± 2,50 MHz) - changing of stopband between: 342,5 MHz .. 344,5 MHz to – 13 dB - changing of –15 dB stopband to fn –13,75 MHz - changing of group delay ripple within : ± 2,50 MHz to 40 ns - changing of group delay ripple within : ± 7,0 MHz to 100 ns Dr. S. Sabah 28.02.2001 1.7 1.8 - changing of relative attenation between: fn –15,6 MHz to fn +18,60 MHz - changing of filter name to TFS326A - changing of input power specification - changing of matching circuit Dr. S. Sabah 15.03.2001 - with customer agreed modification of stopband attenuation min. 13,0 dB - fN + 14,85 MHz...fN + 18,9 MHz to min. 11,0 dB - fN - 13,75 MHz...fN – 30,0 MHz to Dr. S. Sabah 14.05.2001 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.