Filename: tfs 70aw.doc Version 1.4 VI TELEFILTER 24.07.2006 Filter specification TFS 70AW 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 213 Ω || -64,3 pF 134 Ω || -83,2 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 70AW is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 70 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae 9,5 Nominal frequency fN - PB - Passband Pass band ripple Relative attenuation fN fN ± 1,0 fN fN fN fN + + 10 4 2,55 3 … fN MHz … fN ± ± 1,0 1,2 MHz MHz MHz MHz + + 4 2,55 3 10 … … … … fN fN fN fN arel MHz MHz MHz MHz MHz MHz Group delay ripple within PB p-p Phase linearity within PB p-p Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf ** dB tolerance / limit max. fN ± 12 dB 70 MHz 1 MHz 0,4 dB max. 1 dB 0,4 1,2 dB dB max. max. 1 3 dB dB 43 33 33 47 dB dB dB dB min. min. min. min. 40 25 25 40 dB dB dB dB 75 ns max. 200 ns deg max. 2,8 4,5 - - 40 °C ... + 85°C - - 40 °C ... + 85°C -18 deg ppm/K *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fcat(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70aw.doc Version 1.4 VI TELEFILTER 24.07.2006 Filter specification TFS 70AW 2/5 0 2.34 -1 2.19 -12 -2 2.04 -18 -3 1.89 -24 -4 1.74 -5 1.59 -6 1.44 -42 -7 1.29 -48 -8 1.14 -54 -9 0.99 -30 -36 -60 55.42 58.336 61.252 64.168 67.084 70 72.916 frequency in MHz 75.832 78.748 81.664 -10 68 84.58 68.4 68.8 69.2 69.6 70 70.4 frequency in MHz 70.8 71.2 71.6 delay in µs 0 -6 magnitude in dB magnitude in dB Filter characteristic 0.84 72 Construction and pin connection (All dimensions in mm) TFS 70AW ● U30 1 2 Max. 7,3 Max. 9,3 Max. 3 Date code 1 2 3 4 5 6 7 8 9 10 Input Input RF Return Ground Ground Ground Output Output RF Return Ground Ground Ground Date code: U V W ... Year + week 2006 2007 2008 2,54 5,08 0,8 R0 ,3 0,1 0,9 50 Ω Test circuit L1 1 2 6 SAW L2 7 C2 C1 3, 4, 5, 8, 9, 10 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70aw.doc Version 1.4 VI TELEFILTER 24.07.2006 Filter specification TFS 70AW 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 2000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,10 F : 7,50 ± 0,10 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 +0,1/-0 Ao : 7,60 ± 0,10 Bo : 9,60 ± 0,10 Ct : 13,5 P1 t Po P2 W G Ct Bo F G E Do PIN Marker Ko Date Code Typ D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 W2(max) : 22,4 N(min) : 50 C : 13,0 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70aw.doc Version 1.4 VI TELEFILTER 24.07.2006 Filter specification TFS 70AW 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 70aw.doc VI TELEFILTER Version 1.4 Filter specification 24.07.2006 TFS 70AW 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 14.12.2005 1.1 - added 40 dB relative attenuation Chilla 23.12.2005 1.2 - added 3 dB relative attenuation - added 25 dB relative attenuation Chilla 07.02.2006 1.3 - operating temperature range extended Pfeiffer 29.03.2006 1.4 - terminating impedances, typical values, filter characteristics and matching configuration added - passband ripple: limit changed to 1 dB Pfeiffer 24.07.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.