NEC UPD705100GJ-100-8EU

DATA SHEET
MOS INTEGRATED CIRCUIT
µPD705100
V830TM
32-BIT MICROCONTROLLER
The µPD705100 (also called V830) is a microcontroller for incorporation use, which belongs to the V830 familyTM
of the NEC original V800 seriesTM microcontrollers. The V830 can achieve high cost-performance for multimedia
equipment, by integrating quick real-time responses, high-speed arithmetic/logical instructions, and functions suitable
for individual applications.
The following user’s manual describes details of the functions of the V830. Be sure to read it before
designing an application system.
V830 User’s Manual, Hardware
: U10064E
V830 User’s Manual, Architecture : U12496E
FEATURES
• High-performance 32-bit architecture for
• 16-bit bus fixing function
incorporation use
• 16-bit bus system construction
• Instructions suitable for variable application
• Built-in cache memory
Instruction cache : 4K bytes
• Sum-of-products operation
Data cache
• Saturable operation
: 4K bytes
• Built-in RAM
• Branch prediction
Instruction RAM
: 4K bytes
Data RAM
: 4K bytes
• Concatenation shift
• Block transfer instructions
• One-clock-pitch pipeline structure
• 16-/32-bit instructions
•
• Maximum operating frequency
Power-saving mode
• Separate buses for addresses and data
• 100 MHz (internal)
• 4G-byte linear addresses
• 50/33 MHz (external)
• Thirty-two 32-bit general-purpose registers
•
CMOS operation, 3.3-V operation
• Hardware-interlocked register/flag hazard
• 16-level interrupt responses
ORDERING INFORMATION
Part number
Package
µPD705100GJ-100-8EU
144-pin plastic LQFP (fine pitch) (20 × 20 mm)
The information in this document is subject to change without notice.
Document No. U11483EJ3V0DS00 (3rd edition)
Date Published January 1998 J CP(K)
Printed in Japan
The mark
shows major revised points.
©
1995, 1996
µPD705100
PIN CONFIGURATION
144-pin plastic LQFP (fine pitch) (20 × 20 mm)
108
107
106
105
104
103
102
101
100
99
98
97
96
95
94
93
92
91
90
89
88
87
86
85
84
83
82
81
80
79
78
77
76
75
74
73
GND
GND
IC1
IC2
RESET
IC2
IC2
IC2
GND
VDD
VDD
GND
INTV3
INTV2
INTV1
INTV0
INT
IC1
GND
VDD
IC1
ST3
ST2
ST1
ST0
R/W
VDD
GND
A31/CS3
A30/CS2
A29/CS1
A28/CS0
A5
A4
GND
GND
µPD705100GJ-100-8EU
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
GND
GND
A9
A8
A7
A6
SIZ16B
ASEL
GND
VDD
D31
D15
D30
D14
D29
D13
GND
GND
VDD
VDD
D28
D12
D27
D11
D26
D10
VDD
GND
D25
D9
D24
D8
D23
D7
GND
GND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
VDD
VDD
GND
BCLK
CMODE
IC3
NMI
VDD
VDD
GND
A27
A26
A25
A24
A23
A22
GND
GND
VDD
VDD
A21
A20
A19
A18
A17
A16
GND
VDD
A15
A14
A13
A12
A11
A10
VDD
VDD
Caution Leave the IC1 pins open.
Connect each IC2 pin to GND via a dedicated resistor.
Connect each IC3 pin to VDD via a dedicated resistor.
2
72
71
70
69
68
67
66
65
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
VDD
A3
A2
A1/BE3
BH/BE2
BE1
BE0
VDD
VDD
GND
BCYST
READY
HLDRQ
HLDAK
D0
D16
VDD
VDD
GND
GND
D1
D17
D2
D18
D3
D19
GND
VDD
D4
D20
D5
D21
D6
D22
VDD
VDD
µPD705100
PIN NAMES
A1-A31
: Address Bus
CS0-CS3
: Chip Select
D0-D31
: Data Bus
BE0-BE3
: Byte Enable
BH
: Byte or Halfword
ST0-ST3
: Status
BCYST
: Bus Cycle Start
R/W
: Read/Write
READY
: Ready
HLDRQ
: Hold Request
HLDAK
: Hold Acknowledge
SIZ16B
: Bus Size 16 bit
NMI
: Non-Maskable Interrupt Request
INT
: Interrupt Request
INTV0-INTV3
: Interrupt Level
BCLK
: Bus Clock
CMODE
: Clock Mode
ASEL
: Address Select
RESET
: Reset
VDD
: Power Supply
GND
: Ground
IC1-IC3
: Internally Connected
3
µPD705100
BLOCK DIAGRAM
INTV0-INTV3
INT
Interrupt controller
NMI
A1-A31
Instruction cache (4K)
D0-D31
V830 CPU core
Instruction RAM (4K)
CS0-CS3
Barrel shifter
Data RAM (4K)
System registers (11)
RESET
BE0-BE3
Bus interface unit
Data cache (4K)
BH
ST0-ST3
BCYST
R/W
READY
32-bit adder
(with sum-of-products
function)
Write buffer
(4 stages)
SIZ16B
HLDRQ
HLDAK
50/33 MHz
φ = 100 MHz
Clock
controller
BCLK
CMODE
General-purpose registers
32 bits × 32
4
ASEL
50/33 MHz
µPD705100
CONTENTS
1.
2.
3.
4.
PIN FUNCTIONS ........................................................................................................................
7
1.1
Pin Functions .................................................................................................................................
7
ADDRESS SPACE .....................................................................................................................
8
2.1
Memory Space ................................................................................................................................
8
2.2
I/O Space .........................................................................................................................................
10
32-BIT BUS MODE .....................................................................................................................
13
3.1
Relationship between External Accesses and Byte Enable Signals .....................................
13
16-BIT BUS MODE .....................................................................................................................
14
4.1
16-Bit Bus Sizing ...........................................................................................................................
14
4.1.1
Byte/halfword access ....................................................................................................
14
4.1.2
Word access ...................................................................................................................
15
Relationship between External Access and Byte Enable Signals .........................................
16
INTERRUPTS ..............................................................................................................................
17
5.1
Maskable Interrupts .......................................................................................................................
17
5.2
Nonmaskable Interrupts ...............................................................................................................
18
5.3
Reset ................................................................................................................................................
18
CLOCK CONTROLLER .............................................................................................................
19
6.1
4.2
5.
6.
Operation Modes............................................................................................................................
19
6.1.1
Sleep mode .....................................................................................................................
19
6.1.2
Stop mode .......................................................................................................................
19
7.
INTERNAL MEMORY .................................................................................................................
20
8.
REGISTER SETS .......................................................................................................................
21
8.1
21
8.1.1
General-purpose register set .......................................................................................
21
8.1.2
Program counter (PC) ...................................................................................................
22
System Register Set ......................................................................................................................
23
DATA SETS ................................................................................................................................
24
9.1
24
8.2
9.
Program Register Set ....................................................................................................................
Data Types ......................................................................................................................................
9.1.1
Integers ...........................................................................................................................
25
9.1.2
Unsigned integers ..........................................................................................................
25
Data Alignment ...............................................................................................................................
25
10. ADDRESS SPACE .....................................................................................................................
26
9.2
10.1
Addressing Mode ...........................................................................................................................
27
10.1.1
Instruction addresses ...................................................................................................
27
10.1.2
Operand addresses .......................................................................................................
28
5
µPD705100
11. INSTRUCTIONS .........................................................................................................................
29
11.1
Instruction Format .........................................................................................................................
29
11.2
Instructions (Listed Alphabetically) ............................................................................................
31
12. INTERRUPTS AND EXCEPTIONS ............................................................................................
41
13. ELECTRICAL SPECIFICATIONS ..............................................................................................
42
14. PACKAGE DRAWING ................................................................................................................
61
15. RECOMMENDED SOLDERING CONDITIONS ........................................................................
62
6
µPD705100
1. PIN FUNCTIONS
1.1 Pin Functions
Pin name
A2-A27
Input/output
Tristate output
A28-A31/CS0-CS3 Note
Function
At hold
At reset
Address bus
Hi-Z
H
Address bus/chip select
Hi-Z/H
H
D0-D31
Tristate input/output
Bidirectional data bus
Hi-Z
Hi-Z
BE0, BE1
Tristate output
Indicates which data bus can be used
for data access.
Hi-Z
H
BE2/BH
Indicates access to D16-D23/byte or
halfword access.
Hi-Z
H
BE3/A1
Indicates most significant byte access/A1
address.
Hi-Z
H
ST0-ST3
Indicates the status of a bus.
Hi-Z
0101
BCYST
Indicates the start of a bus cycle.
Hi-Z
H
R/W
Indicates whether the bus cycle is
a read or write cycle.
Hi-Z
H
Terminates a bus cycle.
-
-
Requests bus mastership.
-
-
READY
Input
HLDRQ
HLDAK
Output
Response to HLDRQ
L
H
SIZ16B
Input
Fixes the bus width to 16 bits.
-
-
NMI
Nonmaskable interrupt request
-
-
INT
Maskable interrupt request
-
-
INTV0-INTV3
Indicates an interrupt level.
-
-
BCLK
Bus clock input
-
-
CMODE
Specifies the frequency ratio for the
external bus and the internal circuit.
-
-
ASEL
Selects A28-A31/CS0-CS3.
-
-
RESET
Resets the internal state.
-
-
Supplies positive power.
-
-
Ground potential
-
-
V DD
GND
-
Note When used for a chip select signal, this is held at the high level.
7
µPD705100
2. ADDRESS SPACE
2.1 Memory Space
The V830 uses four chip select/address pins and 26 address bus pins to represent a 32-bit address. When the
chip select function is used, a 256M-byte image space is created as three spaces and a 32M-byte image space is
created as one space. When the chip select function is not used, a 4G-byte linear address space is created.
Area 40000000H-7FFFFFFFH in the memory space is reserved as an uncachable area. When this area is
accessed, the cache function is not effective. For all other areas, the cache function is effective.
Within the memory space, built-in instruction RAM and built-in data RAM are mapped. By accessing these areas,
an instruction can be fetched and data loaded/stored within one cycle (internal clock) without activating a bus cycle
externally. Data in the built-in instruction RAM, however, cannot be accessed by using the load/store instructions. Nor
can instructions be fetched from the built-in data RAM. These built-in RAMs are mapped to the cachable area; however,
they are not cached.
8
µPD705100
Figure 2-1. Memory Map
FFFFFFFFH
CS0
Built-in instruction RAM
FFFFFFFFH
FE001000H
FE000FFFH
FE000000H
Cachable area
C0000000H
BFFFFFFFH
Cachable area
80000000H
7FFFFFFFH
CS0
7FFFFFFFH
7E000000H
Uncachable area
CS3
CS2
CS1
40000000H
3FFFFFFFH
6FFFFFFFH
60000000H
5FFFFFFFH
50000000H
4FFFFFFFH
40000000H
Cachable area
CS3
CS2
CS1
00000000H
Chip select signal
CS0
Built-in data RAM
Address space
7E000000H-7FFFFFFFH
2FFFFFFFH
20000000H
1FFFFFFFH
10000000H
0FFFFFFFH
00001000H
00000FFFH
00000000H
Cachable
×
FE001000H-FFFFFFFFH
CS1
40000000H-4FFFFFFFH
×
00001000H-0FFFFFFFH
CS2
50000000H-5FFFFFFFH
×
10000000H-1FFFFFFFH
CS3
60000000H-6FFFFFFFH
×
20000000H-2FFFFFFFH
9
µPD705100
2.2 I/O Space
The V830 represents the I/O space using 32 bits and supports a linear address space of up to 4G bytes.
The 1G-byte area C0000000H-FFFFFFFFH is reserved as an internal I/O area. External I/O cannot be placed in
this area. When accessing that part of the internal I/O area to which internal I/O is not allocated, normal operation
cannot be guaranteed.
Figure 2-2. I/O Map
FFFFFFFFH
Internal I/O area
(1G byte)
C0000000H
BFFFFFFFH
External I/O area
(1G byte)
80000000H
7FFFFFFFH
External I/O area
(1G byte)
40000000H
3FFFFFFFH
External I/O area
(1G byte)
00000000H
10
µPD705100
The cache function is not effective within the I/O space. When the chip select function is used, the area is used
as the 256M-byte image space represented by A2-A27.
Figure 2-3. Image Space Used When Chip Select Function is Used
FFFFFFFFH
Internal I/O area
C0000000H
BFFFFFFFH
Image 11
Image 10
Image 9
Image 8
80000000H
7FFFFFFFH
Image 7
Image 6
Image 5
Image 4
40000000H
3FFFFFFFH
Image 3
Image 2
Image 1
Image 0
00000000H
11
µPD705100
The upper 1G-byte area (C0000000H-FFFFFFFFH) in the I/O space is reserved for internal I/O. To access internal
I/O, the IN.W/OUT.W instructions (in words) must be used. When the internal I/O area is accessed, an external bus
cycle is not activated.
Figure 2-4. Internal I/O Area
FFFFFFFFH
Built-in periphery
Reserved
PLLCR
Internal I/O area
(1G byte)
CMCR
Reserved
C0000000H
BFFFFFFFH
IRAMR
External I/O area
(1G byte)
Reserved
ICTR
80000000H
7FFFFFFFH
Reserved
DCTR
External I/O area
(1G byte)
40000000H
3FFFFFFFH
External I/O area
(1G byte)
00000000H
12
FFFFFFFFH
FFFFFFFCH
FFFFFFFBH
FFFFFFF8H
FFFFFFF7H
FFFFFFF4H
FFFFFFF3H
FE001000H
FE000FFFH
FE000000H
FDFFFFFFH
FA001000H
FA000FFFH
FA000000H
F9FFFFFFH
F2001000H
F2000FFFH
F2000000H
µPD705100
3. 32-BIT BUS MODE
If the SIZ16B input, sampled at reset, is inactive, the external bus width becomes 32 bits (32-bit bus mode). In
this mode, BE2/BH acts as BE2 and BE3/A1 acts as BE3.
3.1 Relationship between External Accesses and Byte Enable Signals
In 32-bit bus mode, BE0-BE3 are output. External accesses are related to byte enable signals as indicated below.
Table 3-1. 32-Bit Bus Mode
Data length
Operand address
Byte enable
State
Bit 1
Bit 0
BE3
BE2
BE1
BE0
0
0
1
1
1
0
Ta,Ts
0
1
1
1
0
1
Ta,Ts
1
0
1
0
1
1
Ta,Ts
1
1
0
1
1
1
Ta,Ts
0
0
1
1
0
0
Ta,Ts
1
0
0
0
1
1
Ta,Ts
Word
0
0
0
0
0
0
Ta,Ts
Burst transfer
0
0
0
0
0
0
Ta,Tb1
0
0
0
0
0
0
Tb2
0
0
0
0
0
0
Tb3
0
0
0
0
0
0
Tb4
Byte
Halfword
13
µPD705100
4. 16-BIT BUS MODE
If the SIZ16B input, sampled at reset, is active, the external bus width becomes 16 bits (16-bit bus mode). In this
mode, the low-order 16 bits (D0-D15) of the data bus are valid, BE2/BH acts as BH and BE3/A1 acts as A1. The highorder 16 bits (D16-D31) of the data bus enter the high-impedance state.
4.1 16-Bit Bus Sizing
The V830 has a bus sizing function by which, to enable access from the data bus to 16 bits of memory or the
I/O space, data can be transferred using only the low-order 16 bits of the 32-bit data bus.
When the SIZ16B input is activated upon a reset, the external data bus width becomes 16 bits (16-bit bus mode).
In 16-bit bus mode, D16-D31 are all set to the high-impedance state and BE0, BE1, BH, and A1 are output in a way
suited to a 16-bit bus system. Connection to D16-D31 is not necessary. The SIZ16B input can be changed only when
the V830 is reset. It cannot be changed at any other time.
4.1.1 Byte/halfword access
Bus cycles in either of two bus states (Ta and Ts) are used for byte/halfword access.
(1) Upper halfword
During read cycles, data is read from D0-D15.
During write cycles, D16-D31 data read from the write buffer is output to D0-D15.
Figure 4-1 illustrates the operation for upper halfword access. In this figure, B indicates the upper halfword (highorder 16 bits of the word).
Figure 4-1. Upper Halfword Access
Read cycle
Write cycle
Data bus
Read buffer
31
31
B
Internal
operation
unit
16
15
B
Internal
operation
unit
16
15
16
15
16
15
B
0
14
Data bus
Write buffer
31
31
0
B
0
0
µPD705100
(2) Lower halfword
During read cycles, data is read from D0-D15.
During write cycles, D0-D15 data read from the write buffer is output to D0-D15.
Figure 4-2 shows the operation for lower halfword access. In this figure, A indicates the lower halfword (low-order
16 bits of the word).
Figure 4-2. Lower Halfword Access
Read cycle
Write cycle
Data bus
Read buffer
31
31
Internal
operation
unit
Internal
operation
unit
16
15
16
15
A
16
15
16
15
A
A
0
Data bus
Write buffer
31
31
A
0
0
0
4.1.2 Word access
Bus cycles in any of three bus states (Ta, Tw1, and Tw2) are used for word access.
During a read cycle, the low-order 16 bits of data and high-order 16 bits of data are sampled from D0-D15 in the
Tw1 and Tw2 state, respectively. During write cycles, the low-order 16 bits of data and high-order 16 bits of data are
output to D0-D15 in the Ta/Tw1 state and Tw2 states, respectively.
Figure 4-3. Read Cycle
Tw1 state
Tw2 state
Read buffer
31
31
Read buffer
Data bus
Data bus
31
31
B
Internal
operation
unit
A
0
Internal
operation
unit
16
15
16
15
A
A
0
16
15
16
15
0
B
0
15
µPD705100
Figure 4-4. Write Cycle
Ta, Tw1 state
Tw2 state
Write buffer
31
31
Data bus
B
Internal
operation
unit
B
Internal
operation
unit
16
15
16
15
16
15
B
0
0
16
15
A
A
Data bus
Write buffer
31
31
0
0
4.2 Relationship between External Access and Byte Enable Signals
In 16-bit bus mode, the BE3/A1 output acts as A1 and BE2/BH output acts as BH. External accesses are related
to the byte enable signals as indicated below.
Table 4-1. 16-Bit Bus Mode
Data length
Byte
Halfword
Word
Burst transfer
16
Operand address
Byte enable
State
Bit 1
Bit 0
A1
BH
BE1
BE0
0
0
0
1
1
0
Ta,Ts
0
1
0
1
0
1
Ta,Ts
1
0
1
1
1
0
Ta,Ts
1
1
1
1
0
1
Ta,Ts
0
0
0
1
0
0
Ta,Ts
1
0
1
1
0
0
Ta,Ts
0
0
0
0
0
0
Ta,Tw1
1
0
0
0
Tw2
0
0
0
0
Ta,Tb1
1
0
0
0
Tb2
0
0
0
0
Tb3
1
0
0
0
Tb4
0
0
0
0
Tb5
1
0
0
0
Tb6
0
0
0
0
Tb7
1
0
0
0
Tb8
0
0
µPD705100
5. INTERRUPTS
V830 interrupts include maskable interrupts, nonmaskable interrupts, and reset operations.
5.1 Maskable Interrupts
Maskable interrupt requests are themselves denoted by INT, and their interrupt levels by INTV0 to INTV3.
The following lists pin states and the corresponding interrupt levels.
Table 5-1. Interrupt Levels
Interrupt level
INTV3
INTV2
INTV1
INTV0
15
0
0
0
0
14
0
0
0
1
13
0
0
1
0
12
0
0
1
1
11
0
1
0
0
10
0
1
0
1
9
0
1
1
0
8
0
1
1
1
7
1
0
0
0
6
1
0
0
1
5
1
0
1
0
4
1
0
1
1
3
1
1
0
0
2
1
1
0
1
1
1
1
1
0
0
1
1
1
1
INT and INTV0 to INTV3 are level inputs. The V830 samples an INT at the rising edge of a bus clock
pulse. INT and INTV0 to INTV3 should be held at the active level until the V830 accepts the interrupt request and
posts to a peripheral, by software, notification of the acceptance of the interrupt request. Although a change to a higher
interrupt level is possible, the timing at which an interrupt request is detected cannot then be posted to peripheral.
Hence, an interrupt request made before such a change may be accepted. If the interrupt request input (INT, INTV0INTV3) fails to satisfy the setup time requirement for the bus clock pulse, the interrupt request will be detected at the
rising edge of the next bus clock pulse.
Upon accepting an interrupt request, the V830 jumps to a fixed address to start interrupt handling. The target
address of the jump is set to FE0000n0H (built-in RAM) or FFFFFEn0H (external memory), where n is the interrupt
level, either of which may be specified with the IHA bit of the system register, HCCW.
Caution Interrupt level 15 is reserved for use by development tools (in-circuit emulator, ROM emulator,
etc). If the user uses interrupt level 15, those development tools may fail to operate.
17
µPD705100
5.2 Nonmaskable Interrupts
The V830 samples an NMI at the rising edge of a bus clock pulse. When the NMI changes from the high to low
level, an interrupt request is detected. Once a nonmaskable interrupt request has been detected, the NMI can
subsequently be deactivated at any time because the NMI is detected at the falling edge. An interrupt request thus
detected is retained in the CPU until the CPU starts interrupt handling.
Upon accepting a nonmaskable interrupt, the V830 jumps to the fixed address (FFFFFFD0H). If another
nonmaskable interrupt is issued during nonmaskable interrupt handling (the NP bit of PSW is set to1), it is retained
in the processor. If, however, another nonmaskable interrupt request is issued during clearing of the latch circuit by
internal processing after the start of nonmaskable interrupt handling, it is not retained in the processor.
5.3 Reset
The V830 can be reset by inputting a low-level signal of 20 or more clock pulses to RESET. After the V830 has
been reset, the CPU starts program execution from address FFFFFFF0H.
If RESET is driven high, the CPU starts instruction fetching from the reset address.
Immediately after power-on or in the stop-mode state, the active pulse width of the RESET should be determined
by adding the PLL oscillation settling time to the active level of 20 clock pulses.
18
µPD705100
6. CLOCK CONTROLLER
6.1 Operation Modes
The V830 supports two clock stop functions, namely, sleep mode and stop mode. Transition from one mode to
another is made by executing special instructions HALT or STBY. The following lists the features of these modes:
Table 6-1. Operation Modes
Sleep mode
V830 Internal state
Stop mode
Internal clock stop
Internal clock stop
PLL operation continuous
PLL operation stop
Bus hold acceptable
Bus hold unacceptable
Built-in RAM/cache data hold
Built-in RAM/cache data hold
Entry to mode
HALT instruction
STBY instruction
Escape from mode
Maskable interrupt/NMI/reset
NMI/reset
6.1.1 Sleep mode
The V830 enters sleep mode upon the execution of a HALT instruction. On the other hand, escape from sleep
mode can be realized by a maskable interrupt, NMI, or reset operation.
In sleep mode, bus hold requests can be accepted. During bus hold, the status becomes high impedance and no
halt acknowledge status is output. At the end of bus hold, a halt acknowledge status is output in sync with the rising
edge of a bus clock pulse.
6.1.2 Stop mode
The V830 enters stop mode when an STBY instruction is executed. On the other hand, escape from stop mode
can be realized using an NMI or a reset operation. The power consumption in stop mode is less than that in the sleep
mode because the PLL circuit stops.
Also, no bus hold requests are accepted in the stop mode.
19
µPD705100
7. INTERNAL MEMORY
The V830 has a 4K bytes × 4 internal memory, consisting of four blocks (instruction cache, data cache, instruction
RAM, and data RAM). The V830 allows any of these internal memory blocks to be accessed in one cycle.
Figure 7-1. Built-In Cache Configuration
Instruction bus
V830 CPU
core
Instruction cache
Decoder
Instruction RAM
External memory
Execution unit
Data cache
Data RAM
Data bus
Cautions 1. Data can not be written into the instruction cache or instruction RAM.
2. A instruction can not be written into the data cache or data RAM.
20
µPD705100
8. REGISTER SETS
8.1 Program Register Set
The V830 has two types of register sets: general-purpose register sets which can be used by programmers, and
system register sets which control the state of the V830. The width of all registers is 32 bits.
8.1.1 General-purpose register set
(1) General-purpose registers
The V830 has 32 general-purpose registers, r0-r31, which can be used either as data registers or address
registers. Note, however, that r0, r30, and r31 contain values that are fixed by hardware or which are used implicitly
by instructions.
(a) Hardware-dependent registers
Hardware-dependent registers contain values that are fixed by hardware or which are used implicitly by
instructions.
r0
: Zero register
Always contains 0.
r30 : Register reserved for operation
Serves as an auxiliary register which stores the result of a multiplication or division instruction.
r31 : Link pointer
The JAL instruction stores the return address in this register.
(b) Software-reserved registers
These registers are used by assemblers and compilers. To use them as registers for variables, first save
their contents to guard against data loss or damage. When their use is no longer required restore the saved
contents.
r1
: Assembler-reserved register
Serves as a working register for creating 32 bits of immediate data. It is used implicitly when
the assembler calculates an effective address.
r2
: Handler stack pointer
r3
: Stack pointer
r4
: Global pointer
r5
: Text pointer
Reserved as the stack pointer for a handler.
Reserved for stack frame creation when a function is called.
Used when accessing a global variable in a data area.
Points to the beginning of a text area.
21
µPD705100
8.1.2 Program counter (PC)
The program counter (PC) is a register which holds the first address of the instruction being executed. Bit 0 of
the program counter is fixed to 0, but is forcibly masked to 0 upon a branch to a point other than a halfword boundary
(bit 0 of the address is 0).
Upon reset, the program counter is initialized to FFFFFFF0H.
Figure 8-1. Program Registers
r0 : Zero register
r1 : Assembler-reserved register
r2 : Handler stack pointer
r3 : Stack pointer
r4 : Global pointer
r5 : Text pointer
r6
r29
r30: Register reserved for operation
r31: Link pointer
PC
22
µPD705100
8.2 System Register Set
System registers are used to control the processor state, save exception/interruption information, and manage
tasks. The V830 has eleven 32-bit system registers. These registers can be accessed using special instructions (LDSR
and STSR instructions).
Figure 8-2. System Registers
#0
EIPC
#1
EIPSW
#2
FEPC
#3
FEPSW
#4
ECR
#5
PSW
#6
PIR
#7
TKCW
#16
DPC
#17
DPSW
#31
HCCW
Remark The system register number is preceded by #.
23
µPD705100
9. DATA SETS
9.1 Data Types
The V830 supports three data types: byte (8 bits), halfword (16 bits), and word (32 bits). Data of these types must
be aligned with byte, halfword, or word boundaries, respectively. Addressing is based on little endian.
(1) Byte data
One byte of data consists of eight consecutive bits, each of which is named. Bit 0 is the LSB (Least Significant
Bit) while bit 7 is the MSB (Most Significant Bit). This data can be placed at any address.
7
0
MSB
LSB
A
Address
(2) Halfword data
One halfword of data consists of 16 consecutive bits, each of which is named. Bit 0 is the LSB, while bit 15 is
the MSB. Halfword data must be aligned with halfword boundaries (in address areas such that bit 0 of the address
of the segment containing bit 0 is 0).
15
0
8 7
A+1
Address
A
A = 2n (where n is a positive integer)
(3) Word data
One word of data consists of 32 consecutive bits, each of which is named. Bit 0 is the LSB and bit 31 is the MSB.
Word data must be aligned with word boundaries (in address areas such that bits 0 and 1 of the address of the
segment containing bit 0 are 0).
16 15
31
Address
A+3
A+2
0
A+1
A
A = 4n (where n is a positive integer)
24
µPD705100
9.1.1 Integers
In the V830, integers are represented by twos complements. They are expressed by bytes, halfwords, or words.
Digit ordering for integers is as follows: Bit 0 is handled as the least significant bit, regardless of the data length.
Larger bit numbers correspond to higher orders.
Data length
Range (in decimal notation)
Byte (8 bits)
–128 to +127
Halfword (16 bits)
–32 768 to +32 767
Word (32 bits)
–2 147 483 648 to +2 147 483 647
9.1.2 Unsigned integers
Unsigned integers are of a data type for which the most significant bit is not handled as a sign bit, but all bits represent
a positive integer. Data of this data type is represented by a binary number and has a size of a byte, halfword, or
word. Digit ordering for unsigned integers is as follows: Bit 0 is handled as the least significant bit, regardless of the
data length. Larger bit numbers correspond to higher orders.
Data length
Range (in decimal notation)
Byte (8 bits)
0 to 255
Halfword (16 bits)
0 to 65 535
Word (32 bits)
0 to 4 294 967 295
9.2 Data Alignment
The V830 requires that data be aligned with appropriate boundaries: word boundaries for word data, halfword
boundaries for halfword data, and byte boundaries for byte data. If a data alignment error is detected, the data address
is automatically changed to an accessible address. It is impossible to predict whether this address change will lead
to correct or incorrect data access. This change is made as follows:
Data size
Method
Byte data
—
Halfword data
Bit 0 is masked to 0.
Word data
Bits 0 and 1 are masked to 0.
25
µPD705100
10. ADDRESS SPACE
The V830 supports 4G-byte linear address spaces for both the memory space and I/O space. It assigns 32-bit
addresses to the memory space. The maximum address is 232 – 1. It also assigns 32-bit addresses to the I/O space.
Byte data aligned with each address is defined such that bits 0 and 7 are the LSB and MSB, respectively. If data
consists of multiple bytes, it is defined such that the byte data at the low-order address contains the LSB and that
at the high-order address contains the MSB (little-endian ordering), unless specified otherwise.
According to V830 terminology, data arranged in two-byte format is called halfword data, while that arranged in
four-byte format is called word data. For data consisting of multiple bytes, the low-order address on the right and the
high-order address on the left, as indicated below.
7
0
Data
Address
Byte at address A
A
15
8
7
0
Data
Address
Halfword at address A
A+1
31
24 23
16 15
A
8
7
0
Data
Address
Word at address A
A+3
26
A+2
A+1
A
µPD705100
10.1 Addressing Mode
The V830 generates two types of addresses, as follows:
• Instruction addresses (used by instructions involving branching)
• Operand addresses (used by instructions which access data)
10.1.1 Instruction addresses
The instruction address is determined by the contents of the program counter (PC). Each time an instruction is
executed, it is automatically incremented by 2 or 4, depending on the number of bytes constituting the instruction being
fetched. When a branch instruction is executed, the branch address is set in the PC by the following addressing mode:
(1) Relative addressing (to PC)
The signed 9 or 26 bits (displacement, or disp) of data contained in the operation code are added to the program
counter (PC). For this addition, the displacement is handled as twos complement data. Bit 8 or 25 is the sign
bit, respectively.
The JR, JAL, Bcond, and ABcond instructions use this addressing.
Addressing for JR and JAL instructions
0
31
31
26 25
Sign extension
PC
0
+
0
S
disp 26
0
31
0
0
PC
Addressing for Bcond and ABcond instructions
31
0
0
PC
+
31
Sign extension
9 8
S
0
disp 9
0
0
31
PC
0
27
µPD705100
(2) Register addressing (via register)
The contents of the general-purpose register (r0-r31) designated in the instruction are transferred to the program
counter (PC).
The JMP instruction uses this addressing.
31
0
31
0
Register m
0
PC
10.1.2 Operand addresses
(1) Register addressing
In this addressing mode, the general-purpose register designated in the general-purpose register designation field
is accessed as an operand. This addressing is used by instructions whose operand format is reg1 or reg2.
(2) Immediate addressing
In this addressing mode, the 5 or 16 bits of data constituting the operation code are handled as an operand. This
addressing is used by those instructions whose operand format is imm5 or imm16.
(3) Based addressing
In this addressing mode, when the memory area containing the operand is accessed, its address is determined
from the sum of the contents of the general-purpose register designated by the address designation code and
the 16-bit displacement in the instruction. This addressing is used by those instructions having an operand format
of disp16[reg1].
31
0
reg 1
Sign extension
28
0
16 15
31
disp 16
µPD705100
11. INSTRUCTIONS
11.1 Instruction Format
The V830 uses two instruction formats: 16-bit and 32-bit. The 16-bit instructions include binary operation, control,
and conditional branch instructions, while the 32-bit instructions include load/store and I/O operation instructions,
instructions for handling 16 bits of immediate data, and jump-and-link instructions.
Some instructions contain unused fields, which must be fixed to 0, which are provided for future use. When an
instruction is actually loaded into memory, its configuration is as follows:
• Low-order part of each instruction format (including bit 0) → Low-order address
• High-order part of each instruction format (including bit 15 or 31) → High-order address
(1) reg-reg instruction format [FORMAT I]
This instruction format has a six-bit operation code field and two general-purpose register designation fields for
operand specification, giving a total length of 16 bits.
15
10 9
5 4
reg 2
opcode
0
reg 1
(2) imm-reg instruction format [FORMAT II]
This instruction format has a six-bit operation code field, a five-bit immediate data field, and a general-purpose
register designation field, giving a total length of 16 bits.
15
5 4
10 9
opcode
reg 2
0
imm 5
(3) Conditional branch instruction format [FORMAT III]
This instruction format has a three-bit operation code field, a four-bit condition code field, a nine-bit branch
displacement field (bit 0 is handled as 0 and need not be specified), and a one-bit sub-operation code, giving a
total length of 16 bits.
15
9 8
13 12
opcode
cond
1 0
disp 9
s
s = 0 : Bcond
s = 1 : ABcond
s : sub-opcode
29
µPD705100
(4) Medium-distance jump instruction format [FORMAT IV]
This instruction format has a six-bit operation code field and a 26-bit displacement field (the lowest-order bit must
be 0), giving a total length of 32 bits.
15
10 9
16
0 31
opcode
0
disp 26
(5) Three-operand instruction format [FORMAT V]
This instruction format has a six-bit operation code field, two general-purpose register designation fields, and a
16-bit immediate data field, giving a total length of 32 bits.
15
5 4
10 9
opcode
reg 2
16
0 31
reg 1
imm 16
(6) Load/store instruction format [FORMAT VI]
This instruction format has a six-bit operation code field, two general-purpose register designation fields, and a
16-bit displacement field, giving a total length of 32 bits.
15
5 4
10 9
opcode
reg 2
16
0 31
reg 1
disp 16
(7) Extended instruction format [FORMAT VII]
This instruction format has a six-bit operation code field, two general-purpose register designation fields, and a
six-bit sub-operation code field, giving a total length of 32 bits.
15
5 4
10 9
opcode
reg 2
reg 1
16
26 25
0 31
sub-opcode
RFU
(8) Three-register operand instruction format [FORMAT VIII]
This instruction format has a six-bit operation code field, three general-purpose register designation fields, and
a six-bit sub-operation code field, giving a total length of 32 bits.
15
5 4
10 9
opcode
reg 2
reg 1
16
21 20
26 25
0 31
sub-opcode
RFU
reg 3
(9) No-operand instruction format [FORMAT IX]
This instruction format has a six-bit operation code field and a one-bit sub-operation code field, giving a total length
of 16 bits.
15
opcode
s : sub-opcode
30
1 0
10 9
RFU
s
µPD705100
11.2 Instructions (Listed Alphabetically)
The instructions are listed below in alphabetic order of their mnemonics.
Explanation of list format
Operand(s)
Instruction
ADD
Format CY OV
reg1, reg2
Instruction
mnemonic
I
*
*
Instruction
format
(See Section 11.1.)
S
Z
*
*
Function
Indicates how each flag changes.
- : Does not change.
* : Changes.
0 : Becomes 0.
1 : Becomes 1.
Abbreviations of operands
Meaning
Abbreviation
reg1
General-purpose register (used as a source register)
reg2
General-purpose register (used mainly as a destination register,
but in some instructions, used as a source register)
reg3
General-purpose register (used mainly as a destination register,
but in some instructions, used as a source register)
imm×
× bits of immediate data
disp×
×-bit displacement
regID
System register number
vector adr
Trap handler address corresponding to trap vector
31
µPD705100
Instruction
Operand(s)
Format
CY
OV
S
Z
Function
ABC
disp9
III
-
-
-
-
High-speed conditional branch (if Carry) relative
to PC.
ABE
disp9
III
-
-
-
-
High-speed conditional branch (if Equal) relative
to PC.
ABGE
disp9
III
-
-
-
-
High-speed conditional branch (if Greater than
or Equal) relative to PC.
ABGT
disp9
III
-
-
-
-
High-speed conditional branch (if Greater than)
relative to PC.
ABH
disp9
III
-
-
-
-
High-speed conditional branch (if Higher) relative
to PC.
ABL
disp9
III
-
-
-
-
High-speed conditional branch (if Lower) relative
to PC.
ABLE
disp9
III
-
-
-
-
High-speed conditional branch (if Less than
or Equal) relative to PC.
ABLT
disp9
III
-
-
-
-
High-speed conditional branch (if Less than)
relative to PC.
ABN
disp9
III
-
-
-
-
High-speed conditional branch (if Negative)
relative to PC.
ABNC
disp9
III
-
-
-
-
High-speed conditional branch (if Not Carry)
relative to PC.
ABNE
disp9
III
-
-
-
-
High-speed conditional branch (if Not Equal)
relative to PC.
ABNH
disp9
III
-
-
-
-
High-speed conditional branch (if Not Higher)
relative to PC.
ABNL
disp9
III
-
-
-
-
High-speed conditional branch (if Not Lower)
relative to PC.
ABNV
disp9
III
-
-
-
-
High-speed conditional branch (if Not Overflow)
relative to PC.
ABNZ
disp9
III
-
-
-
-
High-speed conditional branch (if Not Zero)
relative to PC.
ABP
disp9
III
-
-
-
-
High-speed conditional branch (if Positive)
relative to PC.
ABR
disp9
III
-
-
-
-
High-speed unconditional branch (Always)
relative to PC.
ABV
disp9
III
-
-
-
-
High-speed conditional branch (if Overflow)
relative to PC.
ABZ
disp9
III
-
-
-
-
High-speed conditional branch (if Zero) relative
to PC.
ADD
reg1, reg2
I
∗
∗
∗
∗
Addition. reg1 is added to reg2 and the sum is
written into reg2.
imm5, reg2
II
∗
∗
∗
∗
Addition. imm5, sign-extended to a word, is
added to reg2 and the sum is written into reg2.
imm16,
reg1, reg2
V
∗
∗
∗
∗
Addition. imm16, sign-extended to a word, is
added to reg1, and the sum is written into reg2.
ADDI
32
µPD705100
Instruction
Operand(s)
Format
CY
OV
S
Z
Function
AND
reg1, reg2
I
-
0
∗
∗
AND. reg2 and reg1 are ANDed and the result
is written into reg2.
ANDI
imm16,
reg1, reg2
V
-
0
0
∗
AND. reg1 is ANDed with imm16,
zero-extended to a word, and result is written
into reg2.
BC
disp9
III
-
-
-
-
Conditional branch (if Carry) relative to PC.
BDLD
[reg1], [reg2]
VII
-
-
-
-
Block transfer. 4 words of data are transferred
from external memory to built-in data RAM.
BDST
[reg2], [reg1]
VII
-
-
-
-
Block transfer. 4 words of data are transferred
from built-in data RAM to external memory.
BE
disp9
III
-
-
-
-
Conditional branch (if Equal) relative to PC.
BGE
disp9
III
-
-
-
-
Conditional branch (if Greater than or Equal)
relative to PC.
BGT
disp9
III
-
-
-
-
Conditional branch (if Greater than) relative to
PC.
BH
disp9
III
-
-
-
-
Conditional branch (if Higher) relative to PC.
BILD
[reg1], [reg2]
VII
-
-
-
-
Block transfer. 4 words of data are transferred
from external memory to built-in instruction RAM.
BIST
[reg2], [reg1]
VII
-
-
-
-
Block transfer. 4 words of data are transferred
from built-in instruction RAM to external memory.
BL
disp9
III
-
-
-
-
Conditional branch (if Lower) relative to PC.
BLE
disp9
III
-
-
-
-
Conditional branch (if Less than or Equal)
relative to PC.
BLT
disp9
III
-
-
-
-
Conditional branch (if Less than) relative to PC.
BN
disp9
III
-
-
-
-
Conditional branch (if Negative) relative to PC.
BNC
disp9
III
-
-
-
-
Conditional branch (if Not Carry) relative to PC.
BNE
disp9
III
-
-
-
-
Conditional branch (if Not Equal) relative to PC.
BNH
disp9
III
-
-
-
-
Conditional branch (if Not Higher) relative to PC.
BNL
disp9
III
-
-
-
-
Conditional branch (if Not Lower) relative to PC.
BNV
disp9
III
-
-
-
-
Conditional branch (if Not Overflow) relative to
PC.
BNZ
disp9
III
-
-
-
-
Conditional branch (if Not Zero) relative to PC.
BP
disp9
III
-
-
-
-
Conditional branch (if Positive) relative to PC.
BR
disp9
III
-
-
-
-
Unconditional branch (Always) relative to PC.
IX
-
-
-
-
Return from fatal exception handling.
BRKRET
BV
disp9
III
-
-
-
-
Conditional branch (if Overflow) relative to PC.
BZ
disp9
III
-
-
-
-
Conditional branch (if Zero) relative to PC.
CAXI
disp16[reg1],
reg2
VI
∗
∗
∗
∗
Inter-processor synchronization in multiprocessor system.
33
µPD705100
Instruction
CMP
Operand(s)
CY
OV
S
Z
Function
reg1, reg2
I
∗
∗
∗
∗
Comparison. reg2 is compared with reg1
sign-extended to a word and the condition flag
is set according to the result.
The comparison involves subtracting reg1 from
reg2.
imm5, rag2
II
∗
∗
∗
∗
Comparison. reg2 is compared with imm5
sign-extended to a word and the condition flag
is set according to the result.
The comparison involves subtracting imm5,
sign-extended to a word, from reg2.
II
-
-
-
-
Disable interrupt. Maskable interrupts are
disabled. DI instruction cannot disable
nonmaskable interrupts.
I
-
∗
∗
∗
Division of signed operands. reg2 is divided by
reg1 (signed operands).
DI
DIV
Format
reg1, reg2
The quotient is stored in reg2 and the remainder
in r30. The division is performed so that the
sign of the remainder will match that of the
dividend.
I
-
0
∗
∗
Division of unsigned operands. reg2 is divided
by reg1 (unsigned operands). The quotient is
stored in reg2 and the remainder in r30. The
division is performed so that the sign of the
remainder will match that of the dividend.
EI
II
-
-
-
-
Enable interrupt. Maskable interrupts are
enabled. The EI instruction cannot enable
nonmaskable interrupts.
HALT
IX
-
-
-
-
Processor halt. The processor is placed in
sleep mode.
DIVU
reg1, reg2
IN.B
disp16[reg1],
reg2
VI
-
-
-
-
Port input. disp16, sign-extended to a word,
is added to reg1 to produce an unsigned 32-bit
port address. A byte of data is read from the
resulting port address, zero-extended to a word,
then stored in reg2.
IN.H
disp16[reg1],
reg2
VI
-
-
-
-
Port input. disp16, sign-extended to a word,
is added to reg1 to produce an unsigned 32-bit
port address. A halfword of data is read from
the produced port address, zero-extended to a
word, and stored in reg2. Bit 0 of the unsigned
32-bit port address is masked to 0.
IN.W
disp16[reg1],
reg2
VI
-
-
-
-
Port input. disp16, sign-extended to a word,
is added to reg1 to produce an unsigned 32-bit
port address. A word of data is read from the
resulting port address, then written into reg2.
Bits 0 and 1 of the unsigned 32-bit port address
are masked to 0.
34
µPD705100
Instruction
Operand(s)
Format
CY
OV
S
Z
Function
JAL
disp26
IV
-
-
-
-
Jump and link. The sum of the current PC
and 4 is written into r31. disp26, sign-extended
to a word, is added to the PC and the sum is
set to the PC for control transfer. Bit 0 of
disp26 is masked.
JMP
[reg1]
I
-
-
-
-
Indirect unconditional branch via register.
Control is passed to the address designated by
reg1. Bit 0 of the address is masked to 0.
JR
disp26
IV
-
-
-
-
Unconditional branch. disp26, sign-extended to
a word, is added to the current PC and control
is passed to the address specified by that sum.
Bit 0 of disp26 is masked to 0.
LD.B
disp16[reg1],
reg2
VI
-
-
-
-
Byte load. disp16, sign-extended to a word,
is added to reg1 to produce an unsigned 32-bit
address. A byte of data is read from the
produced address, sign-extended to a word,
then written into reg2.
LD.H
disp16[reg1],
reg2
VI
-
-
-
-
Halfword load. disp16, sign-extended to a word,
is added to reg1 to produce an unsigned 32-bit
address. A halfword of data is read from the
produced address, sign-extended to a word,
then written into reg2. Bit 0 of the unsigned
32-bit address is masked to 0.
LD.W
disp16[reg1],
reg2
VI
-
-
-
-
Word load. disp16, sign-extended to a word,
is added to reg1 to produce an unsigned 32-bit
address. A word of data is read from the
produced address, then written into reg2. Bits 0
and 1 of the unsigned 32-bit address are
masked to 0.
LDSR
reg2, regID
II
∗
∗
∗
∗
Load into system register. The contents of
reg2 are set in the system register identified by
the system register number (regID).
MAC3
reg1, reg2,
reg3
VIII
-
-
-
-
Saturatable operation on signed 32-bit operands.
reg1 and reg2 are multiplied together as signed
integers and the product is added to reg3.
[If no overflow has occurred:]
The result is stored in reg3.
[If an overflow has occurred:]
The SAT bit is set. If the result is positive,
the positive maximum is written into reg3; if
the result is negative, the negative maximum
is written into reg3.
35
µPD705100
Instruction
MACI
Operand(s)
imm16,
reg1, reg2
Format
V
CY
OV
S
Z
-
-
-
-
Function
Sum-of-products operation on signed 32-bit
operands. reg1 and imm16, sign-extended to
32 bits, are multiplied together as signed
integers and the product is added to reg2 as a
signed integer.
[If no overflow has occurred:]
The result is written into reg2.
[If an overflow has occurred:]
The SAT bit is set. If the result is positive,
the positive maximum is written into reg2; if
the result is negative, the negative maximum
is written into reg2.
MACT3
reg1, reg2,
reg3
VIII
-
-
-
-
Saturatable operation on signed 32-bit
operands. reg1 and reg2 are multiplied together
as signed integers and the high-order 32 bits of
the product are added to reg3 as signed integers.
[If no overflow has occurred:]
The result is written into reg3.
[If an overflow has occurred:]
The SAT bit is set. If the result is positive,
the positive maximum is written into reg3; if
the result is negative, the negative maximum
is written into reg3.
MAX3
reg1, reg2,
reg3
VIII
-
-
-
-
Maximum. reg2 and reg1 are compared as
signed integers. The larger value is written
into reg3.
MIN3
reg1, reg2,
reg3
VIII
-
-
-
-
Minimum. reg2 and reg1 are compared as
signed integers. The smaller value is written
into reg3.
MOV
reg1, reg2,
I
-
-
-
-
Data transfer. reg1 is copied to reg2 for
data transfer.
imm5, reg2
II
-
-
-
-
Data transfer. imm5, sign-extended to a word,
is copied into reg2 for data transfer.
MOVEA
imm16,
reg1, reg2
V
-
-
-
-
Addition. The high-order 16 bits (imm16),
sign-extended to a word, are added to reg1 and
the sum is written into reg2.
MOVHI
imm16,
reg1, reg2
V
-
-
-
-
Addition. A word consisting of the high-order
16 bits (imm16) and low-order 16 bits (0) is
added to reg1 and the sum is written into reg2.
MUL
reg1, reg2
I
-
∗
∗
∗
Multiplication of signed operands. reg2 and reg1
are multiplied together as signed values. The
high-order 32 bits of the product (double word)
are written into r30 and low-order 32 bits are
written into reg2.
MUL3
reg1, reg2,
reg3
VIII
-
-
-
-
Multiplication of signed 32-bit operands.
reg2 and reg1 are multiplied together as signed
integers. The high-order 32 bits of the product
are written into reg3.
36
µPD705100
Instruction
MULI
Operand(s)
imm16,
reg1, reg2
Format
V
CY
OV
S
Z
-
-
-
-
Function
Saturatable multiplication of signed 32-bit
operands. reg1 and imm16, sign-extended to
32 bits, are multiplied together as signed
integers.
[If no overflow has occurred:]
The result is written into reg2.
[If an overflow has occurred:]
The SAT bit is set. If the result is positive,
the positive maximum is written into reg2; if
the result is negative, the negative maximum
is written into reg2.
MULT3
reg1, reg2,
reg3
VIII
-
-
-
-
Saturatable multiplication of signed 32-bit
operands. reg1 and reg2 are multiplied
together as signed integers. The high-order
32 bits of the product are written into reg3.
MULU
reg1, reg2
I
-
∗
∗
∗
Multiplication of unsigned operands. reg1 and
reg2 are multiplied together as unsigned values.
The high-order 32 bits of the product (double
word) are written into r30 and the low-order
32 bits are written into reg2.
III
-
-
-
-
No operation.
NOP
NOT
reg1, reg2
I
-
0
∗
∗
NOT. The NOT (ones complement) of reg1 is
taken and written into reg2.
OR
reg1, reg2
I
-
0
∗
∗
OR. The OR of reg2 and reg1 is taken and
written into reg2.
ORI
imm16,
reg1, reg2
V
-
0
∗
∗
OR. The OR of reg1 and imm16, zeroextended to a word, is taken and written into
reg2.
OUT.B
reg2,
disp16[reg1]
VI
-
-
-
-
Port output. disp16, sign-extended to a word,
is added to reg1 to produce an unsigned 32-bit
port address. The low-order one byte of the
data in reg2 is output to the resulting port
address.
OUT.H
reg2,
disp16[reg1]
VI
-
-
-
-
Port output. disp16, sign-extended to a word,
is added to reg1 to produce an unsigned 32-bit
port address. The low-order two bytes of the
data in reg2 are output to the resulting port
address. Bit 0 of the unsigned 32-bit port
address is masked to 0.
OUT.W
reg2,
disp16[reg1]
VI
-
-
-
-
Port output. disp16, sign-extended to a word,
is added to reg1 to produce an unsigned 32-bit
port address. The word of data in reg2 is output
to the produced port address. Bits 0 and 1 of the
unsigned 32-bit port address are masked to 0.
IX
∗
∗
∗
∗
Return from trap/interrupt handling routine.
The return PC and PSW are read from the
system registers so that program execution will
return from the trap or interrupt handling routine.
RETI
37
µPD705100
Instruction
SAR
SATADD3
Operand(s)
Format
CY
OV
S
Z
Function
reg1 ,reg2
I
∗
0
∗
∗
Arithmetic right shift. reg2 is arithmetically
shifted to the right by the displacement
specified by the low-order five bits of reg1
(MSB value is copied to the MSB in sequence).
The result is written into reg2.
imm5, reg2
II
∗
0
∗
∗
Arithmetic right shift. reg2 is arithmetically
shifted to the right by the displacement specified
by imm5, zero-extended to a word. The result is
written into reg2.
reg1, reg2,
reg3
VIII
∗
∗
∗
∗
Saturatable addition. reg1 and reg2 are added
together as signed integers.
[If no overflow has occurred:]
The result is written into reg3.
[If an overflow has occurred:]
The SAT bit is set. If the result is positive,
the positive maximum is written into reg3; if
the result is negative, the negative maximum
is written into reg3.
SATSUB3
reg1, reg2,
reg3
VIII
∗
∗
∗
∗
Saturatable subtraction. reg1 is subtracted from
reg2 as signed integers.
[If no overflow has occurred:]
The result is written into reg3.
[If an overflow has occurred:]
The SAT bit is set. If the result is positive,
the positive maximum is written into reg3; if
the result is negative, the negative maximum
is written into reg3.
SETF
imm5, reg2
II
-
-
-
-
Set flag condition. reg2 is set to 1 if the
condition specified by the low-order four bits of
imm5 matches the condition flag; otherwise it is
set to 0.
SHL
reg1, reg2
I
∗
0
∗
∗
Logical left shift. reg2 is logically shifted to the
left (0 is put on the LSB) by the displacement
specified by the low-order five bits of reg1. The
result is written into reg2.
imm5, reg2
II
∗
0
∗
∗
Logical left shift. reg2 is logically shifted to the
left by the displacement specified by imm5,
zero-extended to a word. The result is written
into reg2.
reg1, reg2,
reg3
VIII
-
-
-
-
Left shift of concatenation. The 64 bits
consisting of reg3 (high order) and reg2
(low order) are logically shifted to the left by the
displacement specified by the low-order five bits
of reg1. The high-order 32 bits of the result are
written into reg3.
SHLD3
38
µPD705100
Instruction
Operand(s)
Format
CY
OV
S
Z
Function
reg1, reg2
I
∗
0
∗
∗
Logical right shift. reg2 is logically shifted to
the right by the displacement specified by the
low-order five bits of reg1 (0 is put on the MSB).
The result is written into reg2.
imm5, reg2
II
∗
0
∗
∗
Logical right shift. reg2 is logically shifted to
the right by the displacement specified by imm5,
zero-extended to a word. The result is written
into reg2.
SHRD3
reg1, reg2,
reg3
VIII
-
-
-
-
Right shift of concatenation. The 64 bits
consisting of reg3 (high order) and reg2
(low order) are logically shifted to the right by
the displacement specified by the low-order five
bits of reg1. The low-order 32 bits of the result
are written into reg3.
ST.B
reg2,
VI
-
-
-
-
Byte store. disp16, sign-extended to a word,
SHR
disp16[reg1]
is added to reg1 to produce an unsigned 32-bit
address. The low-order one byte of data in reg2
is stored at the resulting address.
ST.H
reg2,
disp16[reg1]
VI
-
-
-
-
Halfword store. disp16, sign-extended to a
word, is added to reg1 to produce an unsigned
32-bit address. The low-order two bytes of the
data in reg2 are stored at the resulting address.
Bit 0 of the unsigned 32-bit address is masked
to 0.
ST.W
reg2,
disp16[reg1]
VI
-
-
-
-
Word store. disp16, sign-extended to a word,
is added to reg1 to produce an unsigned 32-bit
address. The word of data in reg2 is stored at
the resulting address. Bits 0 and 1 of the
unsigned 32-bit address are masked to 0.
IX
-
-
-
-
Processor stop. The processor is placed in
stop mode.
STBY
STSR
regID,reg2
II
-
-
-
-
System register store. The contents of the
system register identified by the system
register number (regID) are set in reg2.
SUB
reg1,reg2
I
∗
∗
∗
∗
Subtraction. reg1 is subtracted from reg2.
The difference is written into reg2.
TRAP
vector
II
-
-
-
-
Software trap. The return PC and PSW are
saved in the system registers:
PSW.EP = 1 → Save in FEPC, FEPSW
PSW.EP = 0 → Save in EIPC, EIPSW
The exception code is set in the ECR:
PSW.EP = 1 → Set in FECC
PSW.EP = 0 → Set in EICC
PSW flags are set:
PSW.EP = 1 → Set NP and ID
PSW.EP = 0 → Set EP and ID
Program execution jumps to the trap handler
address corresponding to the trap vector (0-31)
specified by vector and begins exception
handling.
39
µPD705100
Instruction
Operand(s)
Format
CY
OV
S
Z
Function
XOR
reg1,reg2
I
-
0
∗
∗
Exclusive OR. The exclusive OR of reg2 and
reg1 is taken and written into reg2.
XORI
imm16,
reg1,reg2
V
-
0
∗
∗
Exclusive OR. The exclusive OR of reg1 and
imm16, zero-extended to a word, is taken and
written into reg2.
40
µPD705100
12. INTERRUPTS AND EXCEPTIONS
Interrupts are events which occur independently of program execution. They are classified into maskable and
nonmaskable interrupts. In contrast, exceptions are events which are directly related to program execution. Interrupts
and exceptions do not differ greatly in their control flow, but interrupts are assigned higher handling priorities than
exceptions. Fatal exceptions, however, are assigned higher priorities than interrupts.
Under the V830 architecture, the following interrupts and exceptions may occur. When an exception, maskable
interrupt, or nonmaskable interrupt occurs, control is passed to a handler at an address which is predetermined a given
cause. The cause of an exception can be identified by means of the exception code stored in the ECR (Exception
Cause Register). The pertinent handler analyzes the contents of the ECR so that it can handle the exception or interrupt
appropriately.
Table 12-1. Exception/Interrupt Source Codes
Exception/interrupt
Category
Reset
Interrupt
Fatal exception
Exception
NMI
Exception code
ECR Note 1
Handler
address Note1
Return PC
FFF0H
FFFFFFF0H
Indefinite
-
FFFFFFE0H
current PC
Interrupt
FFD0H
FFFFFFD0H
next PC
Double exception
Exception
Note 2
FFFFFFD0H
current PC
TRAP instruction (parameter 0×1n)
Exception
FFBnH
FFFFFFB0H
next PC
TRAP instruction (parameter 0×0n)
Exception
FFAnH
FFFFFFA0H
next PC
Invalid operation code
Exception
FF90H
FFFFFF90H
current PC
Division by zero
Exception
FF80H
FFFFFF80H
current PC
Interrupt
FEn0H
FFFFFEn0H
next PC
Interrupt level n (n = 0-15)
HWCC.IHA = 0
HWCC.IHA = 1
FE0000n0H
Notes 1. Level n is represented by a hexadecimal number (n = 0-F).
2. Exception code of the exception which caused the double exception
41
µPD705100
13. ELECTRICAL SPECIFICATIONS
ABSOLUTE MAXIMUM RATINGS (TA = 25˚C)
Parameter
Symbol
Conditions
Rating
Unit
Power supply voltage
VDD
–0.5 to +4.5
V
Input voltage
VI
–0.5 to +5.5
V
Clock input voltage
VK
VDD = 3.0 to 3.6 V
–0.5 to VDD + 0.3
V
Output voltage
VO
VDD = 3.0 to 3.6 V
–0.5 to +5.5
V
Operating ambient temperature
VA
–10 to +85
˚C
Storage temperature
Tstg
–65 to +150
˚C
Cautions 1. Do not connect an output (or input/output) pin of an IC device directly to any other output (or
input/output) pin of the same device, with the exception of the open-drain and open-collector
pins. Also, do not connect the VDD or VCC pin of an IC device directly to its GND pin or a ground.
Note, however, that these restrictions do not apply to the high-impedance pins of an external
circuit, whose timing has been specifically designed to avoid output collision.
2. Absolute maximum ratings are rated values, beyond which physical damage may be caused
to the product; if the rated value of any of the parameters in the above table is exceeded even
momentarily, the quality of the product may deteriorate. Always use the product within its rated
values, therefore. For IC products, normal operation and quality are guaranteed only when
the ratings and conditions described under the DC and AC characteristics are satisfied.
DC CHARACTERISTICS (TA = –10 to +85˚C, VDD = 3.0 to 3.6 V)
Parameter
Symbol
Conditions
MIN.
TYP.
MAX.
Unit
Low-level clock input voltage
VKL
–0.5
+0.2VDD
V
High-level clock input voltage
VKH
0.8VDD
VDD + 0.3
V
Low-level input voltage
VIL
–0.5
+0.6
V
High-level input voltage
VIH
2.0
5.5
V
Low-level output voltage
VOL
IOL = 3.2 mA
0.4
V
High-level output voltage
VOH
IOH = –400 µA
Low-level input leakage current
ILIL
VI = 0 V
–5
µA
High-level input leakage current
ILIH
VI = VDD
5
µA
VI = 5.5 V
25
µA
0.85VDD
V
Low-level output leakage current
ILOL
VO = 0 V
–5
µA
High-level output leakage current
ILOH
VO = VDD
5
µA
IDD
During operation
120
170
mA
During HALT mode
12
18
mA
During STOP mode
30
150
µA
MAX.
Unit
15
pF
15
pF
Supply
currentNote
Note The supply current (TYP.) is as measured at 3.3 V with the output pin open.
The supply current (MAX.) is as measured at 3.6 V with the output pin open.
Remark f is the input frequency to the BCLK pin.
CAPACITANCE (TA = –10 to +85˚C, VDD = 3.0 to 3.6 V)
Parameter
Symbol
Input capacitance
CI
I/O capacitance
CIO
42
Conditions
fC = 1 MHz
MIN.
µPD705100
AC CHARACTERISTICS (TA = –10 to +85˚C, VDD = 3.0 to 3.6 V)
AC test input waveform (except BCLK)
VDD
0.5VDD
2.0 V
2.0 V
0.6 V
0.6 V
Test point
0V
4 ns
AC test input waveform (BCLK)
VDD
0.5VDD
0.8VDD
0.8VDD
0.2VDD
0.2VDD
Test points
0V
4 ns
AC test output waveform (except BCLK)
0.85VDD
0.5VDD
Test points
0.4 V
Test load
V830 output pin
CL = 50 pF
43
µPD705100
(1) Clock timing
(a) When the internal operating frequency is 75 to 100 MHz
Parameter
Symbol
Conditions
When φ = 3f
When φ = 2f
MIN.
MAX.
MIN.
MAX.
40
20
26.7
Unit
Clock period
1
tCYK
30
ns
Clock pulse high level width
2
tKKH
3
3
ns
Clock pulse low level width
3
tKKL
3
3
ns
Clock pulse rise time
4
tKR
6
5
ns
Clock pulse fall time
5
tKF
6
5
ns
When φ = 3f
When φ = 2f
(b) When the internal operating frequency is 48 to 100 MHz
Parameter
Symbol
Conditions
MIN.
MAX.
MIN.
MAX.
62.5
20
41.6
Unit
Clock period
1
tCYK
30
Clock pulse high level width
2
tKKH
3
3
ns
Clock pulse low level width
3
tKKL
3
3
ns
Clock pulse rise time
4
tKR
6
5
ns
Clock pulse fall time
5
tKF
6
5
ns
1
5
2
4
BCLK (input)
3
Cautions 1. For clock input timings during a reset, see (2), “Reset timing.”
2. The BCLK input must settle within 0.1% of tCYK (
3. The operation is not guaranteed if tKR (
44
4
1
) or tKF (
).
5
) exceeds the maximum value.
ns
µPD705100
(2) Reset timing
(a) When the internal operating frequency is 75 to 100 MHz
Parameter
Symbol
Conditions
When φ = 3f
When φ = 2f
MIN.
MAX.
MIN.
MAX.
Unit
6
tHVR
0
2
0
2
µs
Clock period (when reset)
7
tCYKR
30
40
20
26.7
ns
Clock high level width (when reset)
8
tKKHR
8
5
ns
Clock low level width (when reset)
9
tKKLR
8
5
ns
RESET set time
10
tSRKF
10
8
ns
11
tSRKR
10
8
ns
RESET hold time (relative to BCLK↑)
12
tHKR
0
0
ns
RESET pulse low level width
13
tWRL
Note 1
10
10
ms
Note 2
20
20
tCYKR
RESET hold time
(relative to VDD VALID)
(relative to BCLK↑, active)
RESET set time
(relative to BCLK↑, inactive)
Notes 1. At power-on or return from stop mode
2. Other than the conditions stated in Note 1.
Remarks 1. The reset signal need not satisfy tSRKF (
2. tWRL (
13
10
) or tSRKR (
11
), provided it is within tHVR (
6
).
) is the number of clock cycles (tCYKR) counted after the BCLK signal has settled.
(b) When the internal operating frequency is 48 to 100 MHz
Parameter
Symbol
Conditions
When φ = 3f
When φ = 2f
MIN.
MAX.
MIN.
MAX.
Unit
6
tHVR
0
2
0
2
µs
Clock period (when reset)
7
tCYKR
30
62.5
20
41.6
ns
Clock high level width (when reset)
8
tKKHR
8
5
ns
Clock low level width (when reset)
9
tKKLR
8
5
ns
RESET set time
10
tSRKF
10
8
ns
11
tSRKR
10
8
ns
RESET hold time (relative to BCLK↑)
12
tHKR
0
0
ns
RESET pulse low level width
13
tWRL
Note 1
10
10
ms
Note 2
20
20
tCYKR
RESET hold time
(relative to VDD VALID)
(relative to BCLK↑, active)
RESET set time
(relative to BCLK↑, inactive)
Notes 1. At power-on or return from stop mode
2. Other than the conditions stated in Note 1.
Remarks 1. The reset signal need not satisfy tSRKF (
2. tWRL (
10
) or tSRKR (
11
), provided it is within tHVR (
6
).
13 ) is the number of clock cycles (tCYKR) counted after the BCLK signal has settled.
45
µPD705100
VDD
0.9VDD
6
7
8
BCLK (input)
10
12
9
RESET (input)
13
46
11
µPD705100
(3) Memory and I/O access timing (single transfer) (1/2)
(a) When the internal operating frequency is 75 to 100 MHz
Parameter
Address output delay
Symbol
Conditions
When φ = 3f
When φ = 2f
MIN.
MAX.
MIN.
MAX.
Unit
14
tDKA
2
13
2
13
ns
15
tHKA
2
13
2
13
ns
CSn output delay (relative to BCLK↑) 16
tDKCS
2
13
2
13
ns
CSn output hold time
17
tHKCS
2
13
2
13
ns
18
tDKBC
2
13
2
13
ns
19
tHKBC
2
13
2
13
ns
READY set time (relative to BCLK↑)
20
tSRYK
10
9
ns
READY hold time (relative to BCLK↑)
21
tHKRY
0
0
ns
Data set time (relative to BCLK↑)
22
tSDK
6
6
ns
Data hold time (relative to BCLK↑)
23
tHKD
2
1
ns
Data output delay
24
tDKDT
2
13
2
13
ns
25
tHKDT
2
13
2
13
ns
26
tLZKDT
2
13
2
13
ns
27
tHZKDT
3
20
3
20
ns
(relative to BCLK↑)
Address output hold time
(relative to BCLK↑)
(relative to BCLK↑)
BCYST output delay
(relative to BCLK↑)
BCYST output hold time
(relative to BCLK↑)
(from active, relative to BCLK↑)
Data output hold time
(to active, relative to BCLK↑)
Data output delay
(from float, relative to BCLK↑)
Data output hold time
(to float, relative to BCLK↑)
47
µPD705100
(b) When the internal operating frequency is 48 to 100 MHz
Parameter
Address output delay
Symbol
Conditions
When φ = 3f
When φ = 2f
MIN.
MAX.
MIN.
MAX.
Unit
14
tDKA
1
13
1
13
ns
15
tHKA
1
13
1
13
ns
CSn output delay (relative to BCLK↑) 16
tDKCS
1
13
1
13
ns
CSn output hold time
17
tHKCS
1
13
1
13
ns
18
tDKBC
1
13
1
13
ns
19
tHKBC
1
13
1
13
ns
READY set time (relative to BCLK↑)
20
tSRYK
10
10
ns
READY hold time (relative to BCLK↑)
21
tHKRY
0
0
ns
Data set time (relative to BCLK↑)
22
tSDK
7
7
ns
Data hold time (relative to BCLK↑)
23
tHKD
2
1
ns
Data output delay
24
tDKDT
1
13
1
13
ns
25
tHKDT
1
13
1
13
ns
26
tLZKDT
1
13
1
13
ns
27
tHZKDT
3
20
3
20
ns
(relative to BCLK↑)
Address output hold time
(relative to BCLK↑)
(relative to BCLK↑)
BCYST output delay
(relative to BCLK↑)
BCYST output hold time
(relative to BCLK↑)
(from active, relative to BCLK↑)
Data output hold time
(to active, relative to BCLK↑)
Data output delay
(from float, relative to BCLK↑)
Data output hold time
(to float, relative to BCLK↑)
48
µPD705100
(3) Memory and I/O access timing (single transfer) (2/2)
Ta
Ts
Ts
Ti
BCLK (input)
14
15
Note 1
14
15
16
17
ST0-ST3 (output)
16
CS0-CS3 (output)Note 2
18
19
BCYST (output)
20
21
20
21
READY (input)
22
23
D0-D31 (input/output)
(read)
26
27
24
25
D0-D31 (input/output)
(write)
D0-D31 (input/output)
(write)
Notes 1. A2-A27 (output), BE0-BE3 (output), R/W (output)
2. A28-A31 are output at CS0-CS3 when the chip select function is not used.
Remark Dotted lines indicate the high-impedance state.
49
µPD705100
(4) Memory access timing (burst transfer) (1/3)
(a) When the internal operating frequency is 75 to 100 MHz
Parameter
Address output delay
Symbol
Conditions
When φ = 3f
When φ = 2f
MIN.
MAX.
MIN.
MAX.
Unit
14
tDKA
2
13
2
13
ns
15
tHKA
2
13
2
13
ns
CSn output delay (relative to BCLK↑) 16
tDKCS
2
13
2
13
ns
CSn output hold time
17
tHKCS
2
13
2
13
ns
18
tDKBC
2
13
2
13
ns
19
tHKBC
2
13
2
13
ns
READY set time (relative to BCLK↑)
20
tSRYK
10
9
ns
READY hold time (relative to BCLK↑)
21
tHKRY
0
0
ns
Data set time (relative to BCLK↑)
22
tSDK
6
6
ns
Data hold time (relative to BCLK↑)
23
tHKD
2
1
ns
Data output delay
24
tDKDT
2
13
2
13
ns
25
tHKDT
2
13
2
13
ns
26
tLZKDT
2
13
2
13
ns
27
tHZKDT
3
20
3
20
ns
(relative to BCLK↑)
Address output hold time
(relative to BCLK↑)
(relative to BCLK↑)
BCYST output delay
(relative to BCLK↑)
BCYST output hold time
(relative to BCLK↑)
(from active, relative to BCLK↑)
Data output hold time
(to active, relative to BCLK↑)
Data output delay
(from float, relative to BCLK↑)
Data output hold time
(to float, relative to BCLK↑)
50
µPD705100
(b) When the internal operating frequency is 48 to 100 MHz
Parameter
Address output delay
Symbol
Conditions
When φ = 3f
When φ = 2f
MIN.
MAX.
MIN.
MAX.
Unit
14
tDKA
1
13
1
13
ns
15
tHKA
1
13
1
13
ns
CSn output delay (relative to BCLK↑) 16
tDKCS
1
13
1
13
ns
CSn output hold time
17
tHKCS
1
13
1
13
ns
18
tDKBC
1
13
1
13
ns
19
tHKBC
1
13
1
13
ns
READY set time (relative to BCLK↑)
20
tSRYK
10
10
ns
READY hold time (relative to BCLK↑)
21
tHKRY
0
0
ns
Data set time (relative to BCLK↑)
22
tSDK
7
7
ns
Data hold time (relative to BCLK↑)
23
tHKD
2
1
ns
Data output delay
24
tDKDT
1
13
1
13
ns
25
tHKDT
1
13
1
13
ns
26
tLZKDT
1
13
1
13
ns
27
tHZKDT
3
20
3
20
ns
(relative to BCLK↑)
Address output hold time
(relative to BCLK↑)
(relative to BCLK↑)
BCYST output delay
(relative to BCLK↑)
BCYST output hold time
(relative to BCLK↑)
(from active, relative to BCLK↑)
Data output hold time
(to active, relative to BCLK↑)
Data output delay
(from float, relative to BCLK↑)
Data output hold time
(to float, relative to BCLK↑)
51
µPD705100
(4) Memory access timing (burst transfer) (2/3)
(c) 32-bit bus mode
Ta
Tb1
Tb1
Tb2
Tb2
Tb3
Tb3
Tb4
Tb4
BCLK (input)
14
15
16
17
Note 1
CS0-CS3 (output)Note 2
14
15
15
A3 (output)
14
15
15
A2 (output)
18
19
BCYST (output)
20
21
20
21
22
23
READY (input)
D0-D31 (input/output)
(read)
26
27
D0-D31 (input/output)
(write)
24
D0-D31 (input/output)
(write)
Notes 1. A4-A27 (output), BE0-BE3 (output), ST0-ST3 (output), R/W (output)
2. A28-A31 are output at CS0-CS3 when the chip select function is not used.
Remark Dotted lines indicate the high-impedance state.
52
25
µPD705100
(4) Memory access timing (burst transfer) (3/3)
(d) 16-bit bus mode
Ta
Tb1
Tb2
Tb3
Tb4
Tb5
Tb6
Tb7
Tb8
Ti
BCLK (input)
14
15
A4-A27 (output),
BE0-BE3 (output),
R/W (output)
14
15
ST0-ST3 (output)
16
17
CS0-CS3 (output)Note
14
15
15
A3 (output)
14
15
15
A2 (output)
14
15
15
A1 (output)
14
15
BH (output)
18
19
BCYST (output)
20 21
READY (input)
22
D0-D15 (input/output)
(read)
23
Hi-Z
Hi-Z
26
D0-D15 (input/output)
(write)
Hi-Z
27
Hi-Z
24
25
D0-D15 (input/output)
(write)
Note A28-A31 are output at CS0-CS3 when the chip select function is not used.
53
µPD705100
(5) Interrupt timing
(a) When the internal operating frequency is 75 to 100 MHz
Parameter
Symbol
Conditions
When φ = 3f
MIN.
MAX.
When φ = 2f
MIN.
Unit
MAX.
NMI set time (relative to BCLK↑)
28
tSNK
6
6
ns
NMI hold time (relative to BCLK↑)
29
tHKN
2
1
ns
INT set time (relative to BCLK↑)
30
tSIK
6
6
ns
INT hold time (relative to BCLK↑)
31
tHKI
2
1
ns
(b) When the internal operating frequency is 48 to 100 MHz
Parameter
Symbol
Conditions
When φ = 3f
MIN.
MAX.
When φ = 2f
MIN.
Unit
MAX.
NMI set time (relative to BCLK↑)
28
tSNK
7
7
ns
NMI hold time (relative to BCLK↑)
29
tHKN
2
1
ns
INT set time (relative to BCLK↑)
30
tSIK
7
7
ns
INT hold time (relative to BCLK↑)
31
tHKI
2
1
ns
BCLK (input)
30
31
28
29
INT (input),
INTV0-INTV3 (input)
NMI (input)
54
µPD705100
(6) Bus hold timing (1/2)
(a) When the internal operating frequency is 75 to 100 MHz
Parameter
Symbol
Conditions
When φ = 3f
When φ = 2f
MIN.
MAX.
MIN.
MAX.
Unit
CSn output delay (relative to BCLK↑)
16
tDKCS
2
13
2
13
ns
CSn output hold time
17
tHKCS
2
13
2
13
ns
READY set time (relative to BCLK↑)
20
tSRYK
10
9
ns
READY hold time (relative to BCLK↑)
21
tHKRY
0
0
ns
HLDRQ set time (relative to BCLK↑)
32
tSHQK
6
6
ns
HLDRQ hold time (relative to BCLK↑) 33
tHKHQ
2
1
ns
HLDAK output delay
34
tDKHA
2
13
2
13
ns
35
tHKHA
2
13
2
13
ns
36
tHZKA
3
20
3
20
ns
37
tLZKA
2
13
2
10
ns
38
tHZKD
3
20
3
20
ns
39
tLZKD
2
13
2
10
ns
40
tHZKBC
3
20
3
20
ns
41
tLZKBC
2
13
2
10
ns
(relative to BCLK↑)
(relative to BCLK↑)
HLDAK output hold time
(relative to BCLK↑)
Address delay
(from active, relative to BCLK↑)
Address delay
(from float, relative to BCLK↑)
Data delay
(from active, relative to BCLK↑)
Data delay
(from float, relative to BCLK↑)
BCYST delay
(from active, relative to BCLK↑)
BCYST delay
(from float, relative to BCLK↑)
55
µPD705100
(b) When the internal operating frequency is 48 to 100 MHz
Parameter
Symbol
Conditions
When φ = 3f
When φ = 2f
MIN.
MAX.
MIN.
MAX.
Unit
CSn output delay (relative to BCLK↑)
16
tDKCS
1
13
1
13
ns
CSn output hold time
17
tHKCS
1
13
1
13
ns
READY set time (relative to BCLK↑)
20
tSRYK
10
10
ns
READY hold time (relative to BCLK↑)
21
tHKRY
0
0
ns
HLDRQ set time (relative to BCLK↑)
32
tSHQK
7
7
ns
HLDRQ hold time (relative to BCLK↑) 33
tHKHQ
2
1
ns
HLDAK output delay
34
tDKHA
1
13
1
13
ns
35
tHKHA
1
13
1
13
ns
36
tHZKA
3
20
3
20
ns
37
tLZKA
2
13
2
10
ns
38
tHZKD
3
20
3
20
ns
39
tLZKD
2
13
2
10
ns
40
tHZKBC
3
20
3
20
ns
41
tLZKBC
2
13
2
10
ns
(relative to BCLK↑)
(relative to BCLK↑)
HLDAK output hold time
(relative to BCLK↑)
Address delay
(from active, relative to BCLK↑)
Address delay
(from float, relative to BCLK↑)
Data delay
(from active, relative to BCLK↑)
Data delay
(from float, relative to BCLK↑)
BCYST delay
(from active, relative to BCLK↑)
BCYST delay
(from float, relative to BCLK↑)
56
µPD705100
(6) Bus hold timing (2/2)
Ta
Ts
Ti
Th
Th
Th
Ti
Ta
BCLK (input)
33
32
32
HLDRQ (input)
34
35
HLDAK (output)
36
37
Note 1
16
17
CS0-CS3 (output)Note 2
38
39
40
41
D0-D31 (input/output)
(write)
BCYST (output)
20
21
READY (input)
Notes 1. A2-A27 (output), BE0-BE3 (output), ST0-ST3 (output), R/W (output)
2. A28-A31 are output at CS0-CS3 when the chip select function is not used.
The timings of these signals are the same as stated in Note 1.
Remark Dotted lines indicate the high-impedance state.
57
µPD705100
(7) Halt acknowledge cycle (1/2)
(a) When the internal operating frequency is 75 to 100 MHz
Parameter
Address output delay
Symbol
Conditions
When φ = 3f
When φ = 2f
MIN.
MAX.
MIN.
MAX.
Unit
14
tDKA
2
13
2
13
ns
15
tHKA
2
13
2
13
ns
CSn output delay (relative to BCLK↑)
16
tDKCS
2
13
2
13
ns
CSn output hold time
17
tHKCS
2
13
2
13
ns
18
tDKBC
2
13
2
13
ns
19
tHKBC
2
13
2
13
ns
READY set time (relative to BCLK↑)
20
tSRYK
10
9
ns
READY hold time (relative to BCLK↑)
21
tHKRY
0
0
ns
Data set time (relative to BCLK↑)
22
tSDK
6
6
ns
Data hold time (relative to BCLK↑)
23
tHKD
2
1
ns
Data output delay
24
tDKDT
2
13
2
13
ns
25
tHKDT
2
13
2
13
ns
26
tLZKDT
2
13
2
13
ns
27
tHZKDT
3
20
3
20
ns
Stn output delay (relative to BCLK↑)
42
tDKST
2
13
2
13
ns
Stn output hold time (relative to
43
tHKST
2
13
2
13
ns
(relative to BCLK↑)
Address output hold time
(relative to BCLK↑)
(relative to BCLK↑)
BCYST output delay
(relative to BCLK↑)
BCYST output hold time
(relative to BCLK↑)
(from active, relative to BCLK↑)
Data output hold time
(to active, relative to BCLK↑)
Data output delay
(from float, relative to BCLK↑)
Data output hold time
(to float, relative to BCLK↑)
BCLK↑)
58
µPD705100
(b) When the internal operating frequency is 48 to 100 MHz
Parameter
Address output delay
Symbol
Conditions
When φ = 3f
When φ = 2f
MIN.
MAX.
MIN.
MAX.
Unit
14
tDKA
1
13
1
10
ns
15
tHKA
1
13
1
10
ns
CSn output delay (relative to BCLK↑)
16
tDKCS
1
13
1
10
ns
CSn output hold time
17
tHKCS
1
13
1
10
ns
18
tDKBC
1
13
1
13
ns
19
tHKBC
1
13
1
13
ns
READY set time (relative to BCLK↑)
20
tSRYK
10
10
ns
READY hold time (relative to BCLK↑)
21
tHKRY
0
0
ns
Data set time (relative to BCLK↑)
22
tSDK
7
7
ns
Data hold time (relative to BCLK↑)
23
tHKD
2
1
ns
Data output delay
24
tDKDT
1
13
1
13
ns
25
tHKDT
1
13
1
13
ns
26
tLZKDT
1
13
1
13
ns
27
tHZKDT
3
20
3
20
ns
Stn output delay (relative to BCLK↑)
42
tDKST
1
13
1
13
ns
Stn output hold time (relative to
43
tHKST
1
13
1
13
ns
(relative to BCLK↑)
Address output hold time
(relative to BCLK↑)
(relative to BCLK↑)
BCYST output delay
(relative to BCLK↑)
BCYST output hold time
(relative to BCLK↑)
(from active, relative to BCLK↑)
Data output hold time
(to active, relative to BCLK↑)
Data output delay
(from float, relative to BCLK↑)
Data output hold time
(to float, relative to BCLK↑)
BCLK↑)
59
µPD705100
(7) Halt acknowledge cycle (2/2)
Ta
Tb
Ti
Ti
Ti
Ti
Ta
BCLK (input)
14
15
Note 1
16
19
BCYST (output)
16
17
CS0-CS3 (output)Note 2
42
ST0-ST3 (output)
43
Halt acknowledge
20
21
22
23
READY (input)
D0-D31 (input/output)
(read)
26
27
24
25
D0-D31 (input/output)
(write)
D0-D31 (input/output)
(write)
Notes 1. A2-A27 (output), BE0-BE3 (output), R/W (output)
2. A28-A31 are output at CS0-CS3 when the chip select function is not being used.
The timings of these signals are the same as stated in Note 1.
Remark Dotted lines indicate the high-impedance state.
60
Tb
µPD705100
14. PACKAGE DRAWING
144 PIN PLASTIC LQFP (FINE PITCH) (20 20)
A
B
108
109
73
72
detail of lead end
C
D
S
R
Q
144
1
37
36
F
G
H
I
M
J
K
P
M
N
NOTE
Each lead centerline is located within 0.10 mm (0.004 inch) of
its true position (T.P.) at maximum material condition.
L
ITEM
A
MILLIMETERS
22.0±0.2
INCHES
0.866±0.008
B
20.0±0.2
0.787 +0.009
–0.008
C
20.0±0.2
0.787 +0.009
–0.008
D
22.0±0.2
0.866±0.008
F
1.25
0.049
G
1.25
0.049
H
0.22 +0.05
–0.04
0.009±0.002
I
0.10
0.004
J
0.5 (T.P.)
0.020 (T.P.)
K
1.0±0.2
0.039 +0.009
–0.008
L
0.5±0.2
0.020 +0.008
–0.009
M
0.145 +0.055
–0.045
0.006±0.002
N
0.10
0.004
P
1.4±0.1
0.055±0.004
Q
0.125±0.075
0.005±0.003
R
3° +7°
–3°
3° +7°
–3°
S
1.7 MAX.
0.067 MAX.
S144GJ-50-8EU-2
61
µPD705100
15. RECOMMENDED SOLDERING CONDITIONS
The conditions listed below shall be met when soldering the µPD705100.
For details of the recommended soldering conditions, refer to our document Semiconductor Device Mounting
Technology Manual (C10535E).
Please consult with our sales offices in case any other soldering process is used, or in case soldering is done under
different conditions.
Table 15-1. Soldering Conditions for Surface-Mount Devices
Soldering process
Soldering conditions
Symbol
Infrared ray reflow
Peak package’s surface temperature: 235 °C
Reflow time: 30 seconds or less (210 °C or more)
Maximum allowable number of reflow processes: 2
Exposure limit: 3 daysNote (10 hours of pre-baking is required at 125 °C
afterward)
<Caution>
Non-heat-resistant trays, such as magazine and taping trays, cannot be
baked before unpacking.
IR35-103-2
VPS
Peak package’s surface temperature: 215 °C
VP15-103-2
Reflow time: 40 seconds or less (200 °C or more)
Maximum allowable number of reflow processes: 2
Exposure limit: 3 daysNote (10 hours of pre-baking is required at 125 °C
afterward)
<Caution>
Non-heat-resistant trays, such as magazine and taping trays, cannot be
baked before unpacking.
Partial heating method
Terminal temperature: 300 °C or less
Heat time: 3 seconds or less (for one side of a device)
-
Note Maximum number of days during which the product can be stored at a temperature of 25 °C and a relative
humidity of 65 % or less after dry-pack package is opened.
Caution Do not apply two or more different soldering methods to one chip (except for partial heating
method for terminal sections).
62
µPD705100
NOTES FOR CMOS DEVICES
1 PRECAUTION AGAINST ESD FOR SEMICONDUCTORS
Note: Strong electric field, when exposed to a MOS device, can cause destruction
of the gate oxide and ultimately degrade the device operation. Steps must
be taken to stop generation of static electricity as much as possible, and
quickly dissipate it once, when it has occurred. Environmental control must
be adequate. When it is dry, humidifier should be used. It is recommended
to avoid using insulators that easily build static electricity. Semiconductor
devices must be stored and transported in an anti-static container, static
shielding bag or conductive material.
All test and measurement tools
including work bench and floor should be grounded. The operator should
be grounded using wrist strap. Semiconductor devices must not be touched
with bare hands. Similar precautions need to be taken for PW boards with
semiconductor devices on it.
2 HANDLING OF UNUSED INPUT PINS FOR CMOS
Note: No connection for CMOS device inputs can be cause of malfunction. If no
connection is provided to the input pins, it is possible that an internal input
level may be generated due to noise, etc., hence causing malfunction. CMOS
device behave differently than Bipolar or NMOS devices. Input levels of
CMOS devices must be fixed high or low by using a pull-up or pull-down
circuitry.
Each unused pin should be connected to VDD or GND with a
resistor, if it is considered to have a possibility of being an output pin. All
handling related to the unused pins must be judged device by device and
related specifications governing the devices.
3 STATUS BEFORE INITIALIZATION OF MOS DEVICES
Note: Power-on does not necessarily define initial status of MOS device. Production process of MOS does not define the initial operation status of the device.
Immediately after the power source is turned ON, the devices with reset
function have not yet been initialized. Hence, power-on does not guarantee
out-pin levels, I/O settings or contents of registers. Device is not initialized
until the reset signal is received. Reset operation must be executed immediately after power-on for devices having reset function.
63
µPD705100
Regional Information
Some information contained in this document may vary from country to country. Before using any NEC
product in your application, please contact the NEC office in your country to obtain a list of authorized
representatives and distributors. They will verify:
• Device availability
• Ordering information
• Product release schedule
• Availability of related technical literature
• Development environment specifications (for example, specifications for third-party tools and
components, host computers, power plugs, AC supply voltages, and so forth)
• Network requirements
In addition, trademarks, registered trademarks, export restrictions, and other legal issues may also vary
from country to country.
NEC Electronics Inc. (U.S.)
NEC Electronics (Germany) GmbH
NEC Electronics Hong Kong Ltd.
Santa Clara, California
Tel: 408-588-6000
800-366-9782
Fax: 408-588-6130
800-729-9288
Benelux Office
Eindhoven, The Netherlands
Tel: 040-2445845
Fax: 040-2444580
Hong Kong
Tel: 2886-9318
Fax: 2886-9022/9044
NEC Electronics Hong Kong Ltd.
Velizy-Villacoublay, France
Tel: 01-30-67 58 00
Fax: 01-30-67 58 99
Seoul Branch
Seoul, Korea
Tel: 02-528-0303
Fax: 02-528-4411
NEC Electronics (France) S.A.
NEC Electronics Singapore Pte. Ltd.
Milton Keynes, UK
Tel: 01908-691-133
Fax: 01908-670-290
Spain Office
Madrid, Spain
Tel: 01-504-2787
Fax: 01-504-2860
United Square, Singapore 1130
Tel: 253-8311
Fax: 250-3583
NEC Electronics Italiana s.r.1.
NEC Electronics (Germany) GmbH
Milano, Italy
Tel: 02-66 75 41
Fax: 02-66 75 42 99
Scandinavia Office
Taeby, Sweden
Tel: 08-63 80 820
Fax: 08-63 80 388
NEC Electronics (France) S.A.
NEC Electronics (Germany) GmbH
Duesseldorf, Germany
Tel: 0211-65 03 02
Fax: 0211-65 03 490
NEC Electronics (UK) Ltd.
NEC Electronics Taiwan Ltd.
Taipei, Taiwan
Tel: 02-719-2377
Fax: 02-719-5951
NEC do Brasil S.A.
Cumbica-Guarulhos-SP, Brasil
Tel: 011-6465-6810
Fax: 011-6465-6829
J97. 8
64
µPD705100
[MEMO]
65
µPD705100
Reference: Electrical Characteristics for Microcomputer (IEI-601)
Note that "preliminary" is not indicated in this document, even though the related documents may be preliminary
versions.
V800 series, V830, and V830 family are trademarks of NEC Corporation.
No part of this document may be copied or reproduced in any form or by any means without the prior written
consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in this
document.
NEC Corporation does not assume any liability for infringement of patents, copyrights or other intellectual
property rights of third parties by or arising from use of a device described herein or any other liability arising
from use of such device. No license, either express, implied or otherwise, is granted under any patents,
copyrights or other intellectual property rights of NEC Corporation or others.
While NEC Corporation has been making continuous effort to enhance the reliability of its semiconductor devices,
the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or
property arising from a defect in an NEC semiconductor device, customers must incorporate sufficient safety
measures in its design, such as redundancy, fire-containment, and anti-failure features.
NEC devices are classified into the following three quality grades:
"Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on
a customer designated "quality assurance program" for a specific application. The recommended applications
of a device depend on its quality grade, as indicated below. Customers must check the quality grade of each
device before using it in a particular application.
Standard: Computers, office equipment, communications equipment, test and measurement equipment,
audio and visual equipment, home electronic appliances, machine tools, personal electronic
equipment and industrial robots
Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
systems, anti-crime systems, safety equipment and medical equipment (not specifically designed
for life support)
Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life
support systems or medical equipment for life support, etc.
The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books.
If customers intend to use NEC devices for applications other than those specified for Standard quality grade,
they should contact an NEC sales representative in advance.
Anti-radioactive design is not implemented in this product.