XFGM-3,XFGM-6 Data sheet Pre-amplified/5V Excitation/Gauge Features . . . . . Applications . Industrial instrumentation . Pressure switch, Pneumatic device . Medical device Two accuracy ranks, 1.5 FS and 2.5 FS available Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Non-corrosive liquid measurable (XFGMC only) Part number for ordering XFGM C - 3 025KP G S R H Accuracy Rated pressure (Pa) Length of the pressure port 3 : 3mm 6 : 6mm Model XFGM Available pressure media No mark : Non-corrosive gas only C : Non-corrosive gas and liquid (Contact us about availability) No mark : H : 2.5 1.5 FS FS (Contact us about availability) Terminal leads direction(See Outline Diagram) R: Terminal leads configuration S : Surface mount package Pressure type G : Gauge (Positive pressure) GV : Gauge (Negative pressure) GW : Gauge (Bipolar pressure) Pressure type Gauge pressure XFGM-3 XFGM-6 Package configuration Surface mount package, 3mm pressure port Surface mount package, 6mm pressure port Measurable pressure range (kPa) 100 100 0 100 0 25 0 50 0 100 0 200 0 1000 XFGM-3100KPGWSR XFGM-3100KPGVSR XFGM-3025KPGSR XFGM-3050KPGSR XFGM-3100KPGSR XFGM-3200KPGSR XFGM-3001MPGSR Model Part number for ordering XFGM-6100KPGWSR XFGM-6100KPGVSR XFGM-6025KPGSR XFGM-6050KPGSR XFGM-6100KPGSR XFGM-6200KPGSR XFGM-6001MPGSR Specifications Model/Rated pressure 100KPGW 100KPGV 025KPG 050KPG 100KPG 200KPG Recommended operating conditions Pressure type Gauge pressure 100 100 25 50 100 200 Rated pressure 1.020 1.020 0.255 0.510 1.020 2.040 Measurable pressure range 100 100 0 100 0 25 0 50 0 100 0 200 Pressure media 1 XFGM : Non-corrosive gas only, XFGMC : Non-corrosive gas and liquid Excitation voltage 5.0 0.25 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation voltage 8 Operating temperature 40 125 Storage temperature 40 125 Operating humidity 30 80(No dew condensation) Electric performances/characteristics (Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25 ) Current consumption less than 10 Output impedance less than 10 Source current less than 0.2 Sink current less than 2 Mechanical response time 2 (For the reference) Full scale span voltage 4.5 Offset voltage 1.2 0.2 0.1125, 0.2 0.0675(H) Full scale span voltage 1.2 4.7 0.1125, 4.7 0.0675(H) Accuracy 1.2 2.5, 1.5(H) Note ; 1) Please consult us available when you choose the C models and the H models. 2) Excluding input voltage error. 1 001MPG Unit 1000 10.20 0 1000 kPa kg/cm2 kPa VDC 1.5times of rated pressure VDC RH mA mA mA msec V V V FS/0 85 XFGM-3,XFGM-6 Data sheet Pre-amplified/5V Excitation/Gauge Outline dimensions unit : mm XFGM-3 2.54 2.54 0.8 Pressure port 2 6 5 3 7 1 4 7 3 Vent hole 0.25 X. 15 0.8 6.5 3.5 0.15 3 Index MA Recommended footprint for PCB 10.3 5 4 Labelled faceplate 1.7 1 2.54 2.54 1.4 6 1 2 9.4 Land-pads 3 (unit : mm) unit : mm XFGM-6 2.54 2.54 0.8 Pressure port 2 6 5 3 7 1 4 7 Vent hole 3 10.3 6 5 4 2-R0.5 3.5 Recommended footprint for PCB 2- 1(Holes for projections) 1.4 1.7 1 Projections 1 2 3 Labelled faceplate Land-pads 6.0 Projections 2.54 2.54 MA 0.5 X. 15 0.8 0.25 9.5 6 Index 6.0 9.4 (unit : mm) 2 XFGM-3,XFGM-6 Data sheet Pre-amplified/5V Excitation/Gauge Connection diagram XFGM-3, FGM-6 Vcc(DC5V) Vcc Vout Vout GND C2 Remarks : 1) C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. GND 3) 4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or each other. C1 Transfer Function Vout=Vs (P + ) (Pressure Error Temperature Error Multiplier Vs) Vs=5.0volts Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage. P=Input Pressure(kPa) Model 025KPG(D) 050KPG(D) 100KPG(D) 100KPGV 100KPGW(DW) 200KPG(D) 001MPG(D) 115KPA pressure range 0 25kPa 0 50kPa 0 100kPa 0 100kPa 100 +100kPa 0 200kPa 0 1MPa 15 115kPa.abs 0.036 0.018 0.009 0.009 0.0045 0.0045 0.0009 0.009 Temperature Error Multiplier Temperature Error Multiplier 3.5 3 2.5 2 1.5 1 0.5 0 -40 -20 0 20 40 60 80 85 100 125 120 Temperature Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 3 E-mail : [email protected] 0.04 0.04 0.04 0.04 0.49 0.04 0.04 0.095 Pressure Error(kPa) 0.625 1.25 2.5 2.5 5.0 5.0 25 2.5