GE12 12W AC-DC Interchangeable Industrial Adaptor series ■ Features : Interchangeable AC plugs (plug kit sold separately) Universal AC input / Full range No load power consumption< 0.075W Energy efficiency Level Ⅵ Comply with EISA 2007/DoE and EU ErP Class II power (without earth pin) Protections: Short circuit / Overload / Over voltage Pass LPS Fully enclosed plastic case LED indicator for power on 2 years warranty Interchangeable AC plug specifically for GE series TYPE ORDER NO. Australian type U.K type European type US type Mix four type AC plug-AU AC plug-UK AC plug-EU AC plug-US AC plug-MIX DC VOLTAGE OUTPUT Note.2 5V GE12 I 09-P1J GE12 I 12-P1J I I GE12 I 15-P1J I I GE12 I 18-P1J I I GE12 I 24-P1J GE12 I 07 GE12 I 09 I I GE12 I 12 I I GE12 I 15 I I GE12 I 18 GE12 I 24 7.5V 9V 12V 15V 18V 24V RATED CURRENT 2.0A 1.33A 1.33A 1.0A 0.8A 0.83A 0.625A CURRENT RANGE 0 ~ 2.0A 0 ~ 1.33A 0 ~ 1.33A 0 ~ 1.0A 0 ~ 0.8A 0 ~ 0.83A 0 ~ 0.625A RATED POWER 10W 10W 12W 12W 12W 15W 15W RIPPLE & NOISE (max.) Note.3 50mVp-p 75mVp-p 100mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±3.0% LINE REGULATION Note.5 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% LOAD REGULATION Note.6 ±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±3.0% 85% 85.5% SETUP, RISE, HOLD UP TIME 4000ms, 100ms, 30ms / 230VAC Note.7 90 ~ 264VAC VOLTAGE RANGE 135 ~ 370VDC FREQUENCY RANGE INPUT I I GE12 I 07-P1J I I I I GE12 I 05 I I I I SAFETY MODEL NO. I I I I POWER SUPPLY MAIN BODY ORDER NO. GE12 I 05-P1J I I SPECIFICATION 4000ms, 100ms, 10ms / 115VAC at full load 47 ~ 63Hz EFFICIENCY (Typ.) 80% 82% AC CURRENT 0.4A / 100VAC 0.25A / 230VAC INRUSH CURRENT (max.) COLD START 40A / 100VAC LEAKAGE CURRENT (max.) 0.25mA / 240VAC 110% ~ 200% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 115% ~ 135% rated output voltage OVERLOAD PROTECTION OVER VOLTAGE 84% 84% 85% 80A / 230VAC Protection type : Clamp by zener diode WORKING TEMP. -10 ~ +50℃ (Refer to "Derating Curve") WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85℃, 10 ~ 95% RH TEMP. COEFFICIENT ±0.03% / ℃ (0 ~ 30℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE (Note. 8) EMC EMISSION EMC IMMUNITY LIFE OTHERS MIL-HDBK-217F (25℃) MTBF 100Khrs min. DIMENSION PACKING 70.7*40*38.8mm (L*W*H) 97g ; 50pcs / 6.3kg / CARTON DC OUTPUT PLUG CONNECTOR CABLE NOTE UL60950-1, CSA C22.2, TUV EN60950 -1, AS/NZS 60950.1, CCC GB4943 approved I/P-O/P:4242VDC I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254, GB17625.1 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 2 years : 100% load 30℃, 8 hours / day See page 2 ; Other type available by customer requested See page 2 ; Other type available by customer requested 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 10% to 100% rated load 7.Derating may be needed under low input voltage. Please check the derating curve for more details. 8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 9.Main body unit and AC inlet plug should be ordered separately ; it needs to be used along with any of the AC inlet plug. File Name:GE12-SPEC 2015-09-15 GE12 12W AC-DC Interchangeable Industrial Adaptor Mechanical Specification series 29.8 38.8 Unit:mm AWM2468 16AWG 1000±50mm for 5~12V AWM2468 18AWG 1500±100mm for 15~48V 40 C"+" 11±0.5mm ID 2.1 x OD 5.5 Outside 70.7 Inside Plug Assignment Standard plug: P1J P1J Derating Curve P/N OUTPUT CENTER + Static Characteristics 100 90 80 LOAD (%) LOAD (%) 100 75 50 70 60 50 40 -10 10 20 30 40 AMBIENT TEMPERATURE (℃) 50 90 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:GE12-SPEC 2015-09-15