( 5 : 1 ) 15K1A1112 D-SUB FEMALE 4STD37S M99A10X

F
E
Solder Instruction
D
C
B
A
b
1. Cable should be prepared for soldering. The cable/wires must be pretinned.
n1,16 (37x)
2. Insert cable/wire into solder cup.
b
(5:1)
3. Operate the soldering iron at 350°C, 50 Watt max. and use a pencil tip.
4. Put tip to wire in solder cup.
5. After 1 second bring in solder.
SEALING
COMPOUND
6. Heat for 3 seconds longer. Do not heat contact more than 4 seconds in total.
8. Wait until solder gets rigid again.
9. Do not solder adjacent contacts consecutively,
0,8
alternate position within the connector to minimize heat build up.
b
69,5 +- 0,2
0,56
63,5 `0,13
0,02
8 +- 0,23
54,94 +- 0,02
0,23
C
12,6 +- 0,33
0,43
C
D
9,5 `0,3
7. Remove soldering iron.
6,13 +- 0,17
0,08
D
1,2 `0,2
10°
b
4STD37SoM99A10X CONEC ABC
Ø3,1 `0,1
SEE NOTE 4
B
B
NOTES:
1. METALSHELLS: COPPER ALLOY; min.315µin TIN over 40-80µin NICKEL
2. INSULATORS: PBT GF UL 94 V-0; BLACK
b 3. CONTACTS: COPPER ALLOY; PLATING (SEE PART NO.):
o PLEASE ADD C for 30µin HARD GOLD over min. 50µin NICKEL
o PLEASE ADD B for 20µin HARD GOLD over min. 50µin NICKEL
o PLEASE ADD A for GOLD FLASH over NICKEL (PREFERRED TYPE)
SOLDER CUP ACCEPTS CABLE AWG 20
Directive 2002/95/EC RoHS compliant
F
E
DO NOT ALTER CAD DRAWING BY HAND
A
THIS DRAWING MAY NOT BE COPIED OR
REPRODUCED IN ANY WAY, AND MAY NOT
BE PASSED ON TO A THIRD PARTY WITHOUT
WRITTEN PERMISSION.
OWNERSHIP AND COPYRIGHT OF CONEC GmbH
4. CONNECTOR IS PART MARKED: 4STD37SoM99A10X CONEC ABC (see note 3)
scale:
material:
tolerance
2:1 (5:1)
SEE NOTES
dim. in mm
date
name
drawn 06.08.12
Henneboel
D-SUB FEMALE
appd. 06.08.12
Fischer
37pos. SOLDER CUP
for installation into water resistant hood
dwg no:
DIN-
norm
d-old
6xb
Ä4411
a
Original
rev. description
D
A
title:
18K1IB2A/18K2IB2A
06.08.2012 K.H.
15K1A1112
R
date
name
part no:
C
A3
sh: 1
b
4STD37SoM99A10X (see note 3)
B
A