Filename: tfs 140as.doc Version 1.6 VI TELEFILTER 30.09.2009 Filter specification TFS 140AS 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 25 0 °C dBm 230 Ω || -12 pF 170 Ω || -15 pF Characteristics Remark: The reference level for the relative attenuation arel of the TFS 140AS is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 140,0 MHz without any tolerance. The shift of the filter band width in the operating temperature range (OTR) is included in the production tolerance scheme. Data typ. value Insertion loss (reference level) ae Nominal frequency fN - Centre frequency fC 140,0 PB 12,1 dB tolerance / limit max. MHz - fC 13,5 dB 140,0 MHz ± 0,4 MHz ± 10 MHz Pass band ripple 0,3 dB max. 1 dB Pass band variation 1 dB max. 1,5 dB 23,8 24,4 MHz MHz min. min. 19,12 20 MHz MHz 0,3 0,4 45 43 dB dB dB dB max. max. min. min. 1 1,5 42 40 dB dB dB dB 55 ns max. 70 ns 600 ns max 825 ns deg max. 10 deg 10 dBm Passband BW Bandwidth 1 dB 1,5 dB Relative attenuation fC fC fC fC ± + 9,56 130,0 17,2 … MHz ... MHz ... MHz ... fC fC fC fC ± ± + Group delay ripple within PB 9,56 10 17,2 360,0 arel MHz MHz MHz MHz p-p Absolute group delay within PB Phase linearity within PB p-p 7 Input power level - max. Operable temperature range - - 40 °C ... + 85°C Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf ** - +25 °C - - 45 °C ... + 85°C -94 ppm/K *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz) Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 140as.doc Version 1.6 VI TELEFILTER 30.09.2009 Filter specification TFS 140AS 2/5 0 1.11 -0.6 1.05 -12 -1.2 0.99 -18 -1.8 0.93 -24 -2.4 0.87 -3 0.81 -3.6 0.75 -42 -4.2 0.69 -48 -4.8 0.63 -54 -5.4 0.57 -30 -36 -60 70 84 98 112 126 140 154 frequency in MHz 168 182 196 210 -6 126 128.8 131.6 134.4 137.2 140 142.8 frequency in MHz 145.6 148.4 151.2 delay in µs 0 -6 magnitude in dB magnitude in dB Filter characteristic 0.51 154 Construction and pin connection (All dimensions in mm) TFS 140AS U51 ● 6,8Max. 13,6Max. 2,54 ±0,15 1,5 2,54 ±0,15 1 2 3 4 2,0Max. 1 12 5 11 6 Date code 10 9 8 7 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Ground Ground Output Output RF Return Ground Ground Ground Ground Input Input RF Return Date code: U V W ... Year + week 2006 2007 2008 0,1 0,8 50 Ohm Test circuit L1 C1 5 11 12 SAW 6 L2 C2 1,2,3,4,7,8,9,10 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 140as.doc Version 1.6 VI TELEFILTER 30.09.2009 Filter specification TFS 140AS 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 1700 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction P1 Tape (all dimensions in mm) W : 24,00 +0,30/-0,10 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,10 F : 11,50 ± 0,10 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 Ao : 7,10 ± 0,10 Bo : 13,90 ± 0,10 Ct : 21,5 ± 0,1 Date Code Po Do P2 W G Ct Bo F G E t Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 24,4 +2/-0 W2(max) : 30,4 N(min) : 60 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 140as.doc Version 1.6 VI TELEFILTER 30.09.2009 Filter specification TFS 140AS 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 140as.doc VI TELEFILTER Version 1.6 Filter specification 30.09.2009 TFS 140AS 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Strehl 17.05.2006 1.1 - changed insertion loss Chilla - changed pass band - changed relative attenuation - changed group delay ripple - introduced absolute group delay - changed phase linearity - changed input power level 26.06.2006 1.2 - stopband attenuation updated Chilla 29.06.2006 1.3 - passband extended Chilla 06.07.2006 1.4 - changed relative attenuation temporary - changed group delay ripple - changed characteristics and passband Strehl 18.10.2006 1.5 - Created filter specification - Added terminating impedances - Added typical values - Added filter characteristic - Changed construction - Added test circuit - Changed packing Chilla 21.12.2006 1.6 - Test circuit corrected Chilla 30.09.2009 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.