VECTRON TFS211-1

Filename: tfs 211-1.doc
Version 1.8
VI TELEFILTER
03.08.2004
Filter specification
TFS 211-1
1/5
Measurement condition
Ambient temperature:
23 C
Input power level:
10 dBm
Terminating impedance:
Input:
280 II -3,7 pF
Output:
280 II -3,7 pF
External coil:
127 nH
The filter supports bursted GMSK and EDGE modulation.
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 211-1 is the filter attenuation at 211 MHz. The filter attenuation at 211 MHz is called insertion
loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion
loss ae. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre
frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the
centre frequency fc.
Data
typ. value
Insertion loss
(Reference level)
a e = amin
Centre frequency
fc
Nominal frequency
fN
kHz
kHz
kHz
kHz
MHz
...
...
...
...
fN
fN
fN
fN
±
±
±
±
400
600
800
100
6,5
dB
211,0 MHz ± 25 kHz
kHz
min
215
-
max
max
max
kHz
kHz
kHz
MHz
-
min
min
min
min
3
25
35
40
dB
dB
dB
dB
max
5
s
max
1,0
s
GD
Group delay ripple
fN ± 50 kHz
Out of band intermodulation
Input signals at 211,8 and 212,6 MHz at +10 dBm
Input signals at 210,2 and 209,4 MHz at +10 dBm
Input power level
for less than 1 hour over life time
fN ± 800
kHz ... fN ±
3
MHz
fN ± 3
MHz ... fN ± 100
MHz
3,4
s
–71
–71
dBm
dBm
-
fN ± 100 kHz
Operating temperature range
Frequency inversion temperature
dB
dB
dB
max
max
max
max
15
25
22
25
dBm
dBm
dBm
dBm
min
10
dB
- 5 C ... + 80 C
- 40 C … + 85 C
Storage temperature range
Temperature coefficient of frequency
1,5
2
3
kHz
kHz
kHz
kHz
Group delay at fN
Return loss (S11/S22)
max
211,0 MHz
270
Relative attenuation
a rel
fN
... fN ± 50
fN ± 50
kHz ... fN ± 80
fN ± 80
kHz ... fN ± 100
± 200
± 400
± 600
± 800
dB
211,0
3dB Bandwidth
fN
fN
fN
fN
4,5
tolerance / limit
ca. - 0,036
+ 20
ppm/K
C
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 211-1.doc
Version 1.8
VI TELEFILTER
03.08.2004
Filter specification
Construction, pin connection and 50
TFS 211-1
2/5
- matching network
1
2
3
4
5
S211/1
N07
Output
Ground
External Coil
Ground
Ground
6 Input
7 Ground
8 Ground
9 Ground
10 Ground
Date Code
Date Code:
L
M
N
...
1
2
3
10
4
9
5
8
7
Year + week
1999
2000
2001
6
50 Ohm matching networks
C1
C2
1
6
3
L3
L1
L2
2,4,5,7,8,9,10
L4
1
6
3
C3
L5
L3
C4
2,4,5,7,8,9,10
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 211-1.doc
Version 1.8
VI TELEFILTER
03.08.2004
Filter specification
TFS 211-1
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
5. ESD
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
MIL-STD-883E using coupling network of ISO 10605 and EN 6100-4-2
HBM:250V; MM:200V;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,10
F
: 7,50 ± 0,10
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
: 1,50 +0,1/-0
Ao
: 7,60 ± 0,10
Bo
: 9,60 ± 0,10
Ct
: 13,5
t
Ko
P1
Date Code
Do
Typ
Po
PIN Marker
P2
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4
W2(max) : 22,4
N(min)
: 50
C
: 13,0
C
A
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 211-1.doc
Version 1.8
VI TELEFILTER
03.08.2004
Filter specification
TFS 211-1
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / s ec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 211-1.doc
VI TELEFILTER
Version 1.8
Filter specification
03.08.2004
TFS 211-1
5/5
History
Version
Reason of Changes
Name
Date
1.3
Change date code to weekly date code.
Change filter labelling.
Correct tape and reel information.
Dr. Wall
13.07.2000
1.4
Change stop band attenuation and operating temperature range according
to customer’s request.
Dr. Wall
20.12.2000
1.5
Change stop band attenuation in frequency range fN ± 600 kHz ... fN ± 800 kHz
according to customer requests.
Add maximum input power.
Add support of bursted GMSK and EDGE modulation.
Dr. Wall
22.01.2001
1.6
Change power handling, intermodulation and operating temperature
range according to customer’s request.
Dr. Wall
15.02.2001
1.7
Change input power level for final test from 0 dBm to 10 dBm
Dr. Wall
27.02.2001
1.8.
ESD limits added
Strehl
03.09.2004
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.