Filename: TFS482.doc Version 2.0 Vectron International 07.05.2014 Filter specification TFS 482 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: Input: Output: 23 0 °C dBm 50 50 Ω Ω Characteristics Remark: The maximum attenuation within passband 1 is defined as the insertion loss ae. The nominal frequency fN is fixed at 482 MHz without any tolerance or limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data typ. value fN 482 MHz PB1 fN ± 12.0 MHz Nominal frequency Passband 1 tolerance / limit ae Insertion loss within PB1 2.3 dB PB2 Passband 2 max. 3.0 fN ± 13.4 dB MHz Insertion loss within PB2 2.6 dB max. 4.0 dB Passband variation within PB2 1.0 dB max. 2.0 dB aabs Absolute attenuation fN ± 80 MHz … fN ± 149 MHz 51 dB min. 33.5 dB fN + 149 MHz … fN + 300 MHz 48 dB min. 45.0 dB 200 MHz 61 dB min. 50.0 dB 149 MHz 67 dB min. 55.0 dB 12 ns max. 0.2 µs 1 200 MHz … MHz … fN - Group delay ripple within PB1 p-p IIP3 * Input power level Operating temperature range OTR Storage temperature range Temperature coefficient of frequency TCf ** - min. 36 dBm - max. 10 dBm - - 10 °C ... + 75 °C - - 40 °C ... + 85 °C -76 ppm/K *) fin1 = fC - 14 MHz; fin2 = fC – 14.4 MHz; Pin = 0 dBm; fmeasurement1 = fC - 13.6 MHz; fmeasurement2 = fC - 14.8 MHz. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. **) ∆f(Hz) =TCf (ppm/K) x (T-T0) x fTo (MHz) Generated: Checked / Approved: Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS482.doc Version 2.0 Vectron International 07.05.2014 Filter specification TFS 482 2/5 0 0.5 -1 0.45 -20 -2 0.4 -30 -3 0.35 -40 -4 0.3 -5 0.25 -6 0.2 -70 -7 0.15 -80 -8 0.1 -90 -9 0.05 -50 -60 -100 100 200 300 400 500 600 frequency in MHz 700 800 900 -10 1000 460 465 470 475 480 485 frequency in MHz 490 495 500 505 delay in µs 0 -10 magnitude in dB magnitude in dB Filter characteristic 0 Construction and pin connection (All dimensions in mm) 7 482 ● E19 1 SQ 3,81 +0,2/-0,1 5 3 7 5 0,1 12 0% 0,6 % d 3 1,78 2,54 1 Ground Input Ground Ground Ground Output Ground Ground Date code: E F G ... Year + week 2014 2015 2016 1,2 Max. Date code 1 2 3 4 5 6 7 8 1,78 50 Ω Test circuit L1 2 6 L2 SAW 1, 3, 4, 5, 7, 8 Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS482.doc Version 2.0 Vectron International 07.05.2014 Filter specification TFS 482 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0.35 mm or g respectively, 1 octave per min, 10 cycles per plane, 3 planes; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 15 min. each / 100 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: three times max.; for temperature conditions, see page 4: "Air reflow temperature conditions" This filter is RoHS compliant (2011/65/EU) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 12,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 5,50 ± 0,05 G(min) : 0,75 P2 : 2,00 ± 0,05 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 4,30 ± 0,1 Bo : 4,30 ± 0,1 Ct : 9,2 ± 0,1 P1 t PIN Marker Po P2 W G Ct Bo F G E Do Ko Date Code Typ D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2 C A N W 1 The minimum bending radius is 45 mm. Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS482.doc Version 2.0 Vectron International 07.05.2014 Filter specification TFS 482 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: TFS482.doc Vectron International Version 2.0 Filter specification 07.05.2014 TFS 482 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification Roizengaft 09.12.2003 1.1 - Change of relative attenuation - Change of insertion loss - Add of network matching Roizengaft 12.02.2004 1.2 - Add attenuation at fN – 338 MHz … fN – 362 MHz Dr. Wall 16.02.2004 1.3 - Change of absolute attenuation fN + 149 … 300 MHz - Change insertion loss Strehl 20.01.2005 1.4 - Change stability characteristics - Add typical values and filter characteristic - Generation of filter specification Strehl 09.05.2005 1.5 - Add IIP3 and change stability characteristics Strehl 11.07.2006 1.6 - Correct absolute attenuation Channaa 25.06.2008 2.0 - Additional passband with larger bandwidth specified - Orientation of tape and reel updated - Typos corrected Molke 07.05.2014 Vectron International GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.